• Title/Summary/Keyword: cell arrangement

검색결과 252건 처리시간 0.028초

다중압출 공정을 이용한 마이크로 채널 다중 원통형 고체산화물 연료전지의 in-situ 제조 (In-Situ Fabrication of Micro-channeled Multi Tubular Solid Oxide Fuel Cell using Multi-pass Extrusion Process)

  • 변기천;;김종희;이병택
    • 한국재료학회지
    • /
    • 제17권6호
    • /
    • pp.313-317
    • /
    • 2007
  • In-situ micro-channeled multi tubular solid oxide fuel cell(SOFC) was fabricated using multi-pass extrusion process with out side diameter of 2.7 mm and active length of 5 mm that contained 61 individual cells. Cell materials used in this work were NiO-YSZ (50 : 50 vol.%), 8 mol% yttria-stabilized zirconia(8YSZ), $La_{0.8}Sr_{0.2}MnO_3(LSM)$ as anode, electrolyte, and cathode, respectively. The arrangement of each electrode and electrolyte layer in green bodies showed uniformity and integrity after extrusion and sintering. The XRD analysis confirmed that no reaction phases appeared and the microstructure of the electrolyte was fairly dense (relative density > 96%) after sintering.

First report of blooms of Gonyaulax poly-gramma (Gonyaulacales, Dinophyceae) in the Yeosu waters of the South Sea of Korea

  • Cho, Eun-Seob
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2005년도 봄 학술발표회지 제14권(제1호)
    • /
    • pp.241-244
    • /
    • 2005
  • The aim of this study was to determine the first outbreaks of nontoxic Gonyaulax polygramma Stein in Yeosu waters in place of harmful Cochlodinium polykrikoides Margalef, which has occurred annually in the same coastal region since 1995. The observation of cellular arrangement and structure by electron microscopy showed that G. polygramma isolated from Yeosu waters had a few spines connecting with mem-branes and prominent longitudinal ridges on the cell surface, with a cingular dis-placement 1.5 times their cell width. Furthermore, the location of the nucleus wasposterior of large oval formation according to electron microscopy. On 6 August, 2004,the first bloom of G. pozygramma occurred, the date of own its disappearance was with a maximum cell density of 8,000 cells ml$^{-1}$ on 21 August, 2004. During the period of this study, the horizontal distribution of sea water temperature and salinity showed a strong coastal front, whereas the front of DIN (Dissolved Inoganic Nitrogen) was significantly different between the occurrence and disappearance of G. polygramma blooms. These results suggested that the process of the breakdown of stratification by wind and a low level of inorganic nitrogen play important roles in the rapid growth of G. polygrmma, which is associated with a greater robustness in growth against DIN than that of C.polykrikoides in nature.

  • PDF

요로상피병변의 요세포학적 소견 (Urinary Cytologic Findings of Urothelial Lesions)

  • 최윤정;이광길
    • 대한세포병리학회지
    • /
    • 제5권2호
    • /
    • pp.130-136
    • /
    • 1994
  • Urinary cytology is increasingly accepted as a diagnostic tool in the detection and follow-up of patients with bladder cancer. However, its value is reduced by several limitations, especially by the lack of cytologic criteria specifically reflecting the morphology of low-grade urothelial neoplasm. We reviewed histologically proven 50 cases of urine cytology with emphasis on cytologic findings of benign atypia and differential findings of urothelial neoplasm according to the grade. The diagnoses included 17 benign lesions(including 5 cases of urine calculi) and 33 malignant lesions (including 28 transitional cell carcinomas, 3 squamous cell carcinomas, 1 adenocarcinoma and 1 prostate adenocarcinoma), Diagnostic accuracy was 92%. Important cytodiagnostic criteria for benign atypia and low grade malignancy were cellularity, number of cell clusters, and morphology and arrangement of urothelial cells. The cytologic findings of urothelial neoplasms according to histologic grade were relatively well correlated with the histologic findings. However, the cytologic criteria were not sufficient to readily distinguish grade I from grade II. In view of this, we think that cytologic nomenclature "low-grade" and "high-grade" is a more reliable criterion. Recognition of subtle cellular morphologic features specific for urothelial lesions(including benign or malignancy) and proper fixation, processing and staining of specimen can expand the role of urinary cytology In detection and follow-up of patients.

  • PDF

The Effect of Quercetin in Corneal Opacity Induced by Mitomycin-C

  • Lee, Yoon Jeong
    • Applied Microscopy
    • /
    • 제44권3호
    • /
    • pp.88-95
    • /
    • 2014
  • This study examined the effects of quercetin on corneal opacity caused by corneal edema by suppressing the damage on corneal endothelial cell, which was induced by mitomycin-C (MMC). In the MMC-treated group, the number of keratocytes was noticeably fewer compared to that of other groups. Although this group showed normal amount of fiber in the corneal stroma, the thickness was shown to be very thick and the alignment of the corneal endothelial cells that worked as the barrier against aqueous humor was irregular. According to such results, it was known that corneal opacity induced by MMC is not caused by proliferation of keratocytes, but by corneal edema triggered by the infiltration of aqueous humor. In the MMC+quercetin and quercetin+MMC-treated groups, the number of keratocytes was higher and polymorphonuclear leukocytes infilteration was lower significantly compared to that of the MMC-treated group. Although the amounts of fiber and endothelioid cell arrangement were normal, there was more space observed in the corneal stroma. Nonetheless, these groups showed significantly lower stromal thickness compared to that of the MMC group. In conclusion, quercetin has the effect on the reduction of corneal opacity caused by corneal edema that work MMC-induced damage to the corneal endothelial cells.

First report on Gonyaulax polygramma (Gonyaulacales, Dinophyceae) blooms in the Yeosu waters of the South Sea of Korea

  • Cho Eun-Seob
    • 한국환경과학회지
    • /
    • 제14권7호
    • /
    • pp.639-647
    • /
    • 2005
  • The aim of this study is to determine the outbreaks of nontoxic Gonyaulax polygramma Stein in Yeosu waters in place of harmful Cochlodinium polykrikoides Margalef, which has occurred annually in the same region since 1995. The observation of cellular arrangement and structure by electron microscopy showed that G. polygramma isolated from Yeosu waters had a few spines connecting with membranes and prominent longitudinal ridges on the cell surface, with a cingular displacement 1.5 times their cell width. Furthermore, the location of the nucleus was posterior of large oval formation according to electron microscopy. On 6 August, 2004, the first bloom of G. polygramma occurred, the date of its disappearance was with a maximum cell density of 8,000 cells $ml^{-1}$ on 21 August, 2004. During the period of this study, the horizontal distribution of sea water temperature and salinity showed a strong coastal front, whereas the front of DIN (Dissolved Inorganic Nitrogen) was significantly different between the occurrence and disappearance of G. polygramma blooms. These results suggested that the process of the breakdown of stratification by wind and a low level of inorganic nitrogen play important roles in the rapid growth of G. polygramma, which is associated with a greater robustness in growth against DIN than that of C. polykrikoides in nature.

조사후시험시설에서의 핫셀 배기포집시스템의 성능평가 (Performance of the Exhaust Filtration System of Hot Cell at PIEF)

  • 황용화
    • 설비공학논문집
    • /
    • 제23권12호
    • /
    • pp.799-804
    • /
    • 2011
  • Radioactivity of high concentrations have existed in the handling nuclear materials in hot cell of PIEF(Post Irradiation Examination Facility). The exhaust filtration system was enabled to process cylindrical filters by using a manipulator in the hot cell. By establishing a double filtration system with two filters, backup protection against leakage or failure of the first is provided by the second filter. Additionally, this a arrangement is arrange intended to increase the total filtration efficiency. The result of the pressure drop changing in the air flow of the cylindrical and HEPA filters is observed by a curved line. A filtering efficiency of more than 99.99% to $0.3{\mu}m$ particle appears in the upstream and downstream during the efficiency test on the HEPA filters. The V-pleats type had a lower pressure drop than the separator type. There was no damage during usage and was found to be suitable with high capacity of air volume. Therefore, by carrying out performance tests of the exhaust filtration system, efficiency and safety can be achieved.

악하부에 발생한 여포성 수지상세포 육종 1예 (A Case of Follicular Dendritic Cell Sarcoma in Submandibular Region)

  • 유재호;이동원;김정규
    • 대한두경부종양학회지
    • /
    • 제39권2호
    • /
    • pp.41-44
    • /
    • 2023
  • Follicular dendritic cell sarcoma (FDCS) is rare lymphoid sarcoma occurs anywhere in body, mostly in lymph nodes. Sixty-two-year-old man presented left submandibular gland region mass for 5 months. Mass excision with submandibular gland resection was performed. Histopathology showed proliferation of spindle and ovoid cells with storiform arrangement which were positive for CD21, CD23, Vimentin, Ki-67, suggested FDCS in submandibular gland region lymph node. Tumor size was 3cm with no involvement of resection margin, nor cellular atypia and necrosis, so regular follow up was performed. After 4 years, new enhancing mass in left submandibular area was found. Wide excision of mass with neck dissection on left level I-III was performed. Histopathology confirmed recurrence of FDCS. The patient underwent radiation therapy from left mandible to hyoid area. After 2 years, new nodule was found in left lung upper lobe, and wedge resection confirmed metastasis of FDCS. The patient is on adjuvant chemotherapy.

홀수스트링 PV모듈의 바이패스 다이오드 배치에 의한 전기적 특성 (Electrical Characteristics of PV Modules with Odd Strings by Arrangement on Bypass Diode)

  • 신우균;고석환;주영철;송형준;강기환
    • 한국태양에너지학회 논문집
    • /
    • 제37권4호
    • /
    • pp.1-11
    • /
    • 2017
  • Most PV modules are fabricated by 6 cell-strings with solar cells connected in series. Moreover, bypass diodes are generally installed every 2 cell-strings to prevent PV modules from a damage induced by current mismatch or partial shading. But, in the case of special purpose PV module, like as BIPV (Building Integrated Photovoltaic), the number of cell-strings per module varies according to its size. Differ from a module employing even cell-strings, the configuration of bypass diode should be optimized in the PV module with odd strings because of oppositely facing electrodes. Hence, in this study, electrical characteristics of special purposed PV module with odd string was empirically and theoretically studied depending on arrangement of bypass diode. Here, we assumed that PV module has 3 strings and the number of bypass diodes in the system varies from 2 to 6. In case of 2 bypass diodes, shading on a center string increases short circuit current of the module, because of a parallel circuit induced by 2 bypass diodes connected to center string. Also, the loss is larger, as the shading area in the center string is enlarged. Thus, maximum power of the PV module with 2 bypass diode decreases by up to 59 (%) when shading area varies from 50 to 90 (%). On the other hand, In case of 3 and 6 bypass diodes, the maximum power reduction was within about 3 (W), even the shading area changes from 50 to 90 (%). As a result, It is an alternative to arrange the bypass diode by each string or one bypass diode in the PV module in order to completely bypass current in case of shading, when PV module with odd string are fabricated.

Development of a Flow Analysis Code Using an Unstructured Grid with the Cell-Centered Method

  • Myong, Hyon-Kook;Kim, Jong-Tae
    • Journal of Mechanical Science and Technology
    • /
    • 제20권12호
    • /
    • pp.2218-2229
    • /
    • 2006
  • A conservative finite-volume numerical method for unstructured grids with the cell-centered method has been developed for computing flow and heat transfer by combining the attractive features of the existing pressure-based procedures with the advances made in unstructured grid techniques. This method uses an integral form of governing equations for arbitrary convex polyhedra. Care is taken in the discretization and solution procedure to avoid formulations that are cell-shape-specific. A collocated variable arrangement formulation is developed, i.e. all dependent variables such as pressure and velocity are stored at cell centers. For both convective and diffusive fluxes the forms superior to both accuracy and stability are particularly adopted and formulated through a systematic study on the existing approximation ones. Gradients required for the evaluation of diffusion fluxes and for second-order-accurate convective operators are computed by using a linear reconstruction based on the divergence theorem. Momentum interpolation is used to prevent the pressure checkerboarding and a segregated solution strategy is adopted to minimize the storage requirements with the pressure-velocity coupling by the SIMPLE algorithm. An algebraic solver using iterative preconditioned conjugate gradient method is used for the solution of linearized equations. The flow analysis code (PowerCFD) developed by the present method is evaluated for its application to several 2-D structured-mesh benchmark problems using a variety of unstructured quadrilateral and triangular meshes. The present flow analysis code by using unstructured grids with the cell-centered method clearly demonstrate the same accuracy and robustness as that for a typical structured mesh.

고온고습 시험을 통한 태양전지의 장기 신뢰성에 관한 연구 (Study on the Long-term Reliability of Solar Cell by High Temperature & Humidity Test)

  • 강민수;전유재;김도석;신영의
    • 에너지공학
    • /
    • 제21권3호
    • /
    • pp.243-248
    • /
    • 2012
  • 본 연구는 고온고습 시험을 통하여 Cell 레벨에서의 표면관찰 및 효율저하를 분석하였다. 고온고습 시험조건은 KS C IEC-61215에서 제시한 PV 모듈하의 조건을 이용하여 온도 $85^{\circ}C$, 습도 85%, 1000hr 동안 수행하였다. EL(Electroluminescence)촬영을 통하여 Cell 표면의 이상 유 무를 분석한 결과, 시간이 경과함에 따라, 부분적으로 표면이 손상되어 변색되는 것을 확인하였다. 고온고습 시험 전 단결정 Cell 및 다결정 Cell의 효율은 각각 17.7%, 15.5%였으며, 1000hr 수행 후 15.6%, 14.0%로 각각 11.9%와 9.3%의 감소율을 보였다. 또한, 경년 시 나타나는 전기적 특성을 분석하기 위하여 FF(Fill Factor)값을 분석한 결과, 고온고습 시험 후 단결정 Cell은 78.7%에서 75.0%로 4.7%, 다결정 Cell은 78.1%에서 76.7%로 1.8%의 감소율을 보였다. 태양전지 실리콘의 원자배열 및 순도에 따라 효율 변화에 영향을 받아 단결정 Cell이 다결정 Cell보다 효율저하가 크게 나타났다고 판단된다. 또한, FF감소율보다 효율 감소율이 크게 저하된 것을 확인할 수 있었으며, 이는 Cell의 외부환경적 요인에 의한 표면 손상이 p-n접합층 접촉저항과 경년 시 나타나는 FF 감소율보다 크게 영향을 준 것으로 판단된다.