• Title/Summary/Keyword: ceiling

Search Result 983, Processing Time 0.023 seconds

A Field Survey of Rack-Type Warehouse for Commodity Classification System in Korea (국내 랙크식 창고 수용물품 등급분류를 위한 현장조사)

  • Kim, Woon-Hyung;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.98-105
    • /
    • 2016
  • A fire risk assessment in rack-type warehouse is typically determined based on the following factors: 1. flammability and fire loads for storage of goods, packing materials, and pallet, 2. a ceiling height of warehouse indoor spaces, and 3. height, arrangement, and spacing for storage racks. For appropriately extinguishing and protecting the fire in warehouses, therefore, it is necessary to classify combustibles considering the previously mentioned factors and to develop design Standards for sprinkler system. As the first step to apply automatic sprinkler system to domestic warehouses, this study investigated characteristics for commodity distribution and warehouse configuration using 28 warehouses in five distribution complexes located in Gyeonggi-do, South Korea. In addition, this study analyzed Standards for commodity distribution adopted in USA, Europe, and Japan. Using the field survey analysis, this study was aimed to provide baseline data to prepare for Commodity Classification Standard for warehouses in South Korea.

Assessment of Indoor Air Quality in Commercial Office Buildings (업무용 빌딩 내 사무실의 실내공기질 평가)

  • Jeong, Jee Yeon;Lee, Byung Kyu;Phee, Young Gyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.1
    • /
    • pp.31-42
    • /
    • 2007
  • Recently, concerns regarding indoor air quality in offices have continued to increase. Thirty offices in five metropolitan commercial buildings were surveyed from February to April 2004. Sampling was performed during normal business hours. Thermal comfort factors such as temperature and relative humidity, carbon dioxide ($CO_2$), carbon monoxide (CO), formaldehyde (HCHO), respirable dust, $PM_{10}$ were sampled and analyzed to determine the mean, standard deviation, range, and correlation for each of those parameters. The data was then compared to office as standard of Ministry of Labor, and guideline applicable to the indoor environment. The results represented that the temperature was slightly higher than the standard of American Society of Refrigerating and Air-Conditioning Engineers (ASHRAE), the relative humidity was lower that the standard of ASHRAE. The range of the 8-TWA concentration of $CO_2$ was 639 ~ 786 ppm, but 33.3% of the total thirty offices exceeded the 1000 ppm as ceiling concentration. The concentration of CO was less than 3 ppm, which was similar to that of offices in Japanese. The mean concentration of formaldehyde was 0.032 ppm, and only 2 % of total samples (193) exceeded the 0.1 ppm, standard of formaldehyde in office air. The concentration of respirable dust and $PM_{10}$ was not exceeded the standard of those parameters, $150{\mu}g/m^3$. The concentration of those parameters in the office air was statistically correlated.

A Study on the Degree of Preference to the Psychological Environment of Supporting Facilities in Department Stores - Focused on the Privacy and Sociality about Office Space and Rest Space - (백화점 지원시설의 심리적 환경에 관한 선호도 연구 - 업무공간과 휴게공간에 대한 독립성과 사회성을 중심으로 -)

  • Park, Eui-Jeong;Seo, Ji-Eun;Seo, Hee-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.4
    • /
    • pp.66-73
    • /
    • 2010
  • The purpose of this study is to develop the basis data for methods of the plan to make the office space of the psychological environment by survey of preference to users in Department Store. The results are as follows : First, we could know that the space plan has to be considered the privacy and sociality for the psychological environment in office space. Second, we could know that there are efficient methods of space plan to use the cutoff division by partitions, the psychological division by furniture and the sensitive division by material for privacy in office and resting space. For sociality, there are efficient arrangement methods to plan by division type in office space and by opening type in resting space. And it is good method to use by color that is one in esthetical elements. Third, if we considered users, it is good method to use partitions to cutoff from the floor to the ceiling for privacy in office space and to use movable furnitures to cutoff for privacy in resting space. Forth, we could know that there is the difference in methods of space plan to be preferred by user's variables for privacy and sociality in office and resting spaces. Thus, i think that we have to study considering user's variables and types of department store.

Study of Optimal Light Scattering Pattern Design for Flat Lighting Device using Glass Light Guide (유리도광체를 이용한 평판조명용 광확산패턴의 최적설계 연구)

  • Han, Jeong-Min;Kim, Won-Bae
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.242-246
    • /
    • 2017
  • In this study, it was investigated about optical simulation in high brightness and high uniformity general lighting using glass light guide plate. And we adopt edge-light emission type light plate. Edge-light type lighting has been used LCD application, especially note PC or smart phone backlight unit. Because it had the good properties such as slim shape and light weight. We thought this type was suitable for general lighting application such as wall attached type or ceiling mount type. But many of edge-light type lighting had problems. It called slanted output light rays. That was main key parameter how could control the direction of output light rays. We investigated the solution of this problems, using ray tracing method, we recognized the major fact of the solution relied on the geometric structure of diffusing dot shape. We set the conditions of aspect ratio in diffusing dot shape such as 0.5 to 1. And, at first, we designed diffusing dots shape based on the results of optical simulation and made specimen. as above condition, and acquired good result in confirming dots shape such as the value of the output rays's peak angle was around 75 degrees. And good light distribution characteristics were measured by slated spectro-radiometer. It was shown that the effective ways of designing light distribution characteristics using optical simulation such as ray tracing linear method for making general lighting using glass light guide plate.

A Study on Resisting Force of H-Shaped Beam Using Glass Web Plate (유리 웨브를 사용한 H형 합성보의 내력에 관한 연구)

  • Son, Ki-Sang;Jeon, Chang-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.3 s.75
    • /
    • pp.73-80
    • /
    • 2006
  • Generally beam design depends on the yielding and maximum strength of each member varying with its section shape. Web plate of H-shape beam has not been substituted with glass plate, because it is known that its strength and heat properties are different and it is limited to substitute the existing steel web with glass element. Ceiling height of each room should be decreased with more than 60-80cm due to the beam. Differently from this condition, glass web beam has a good point to see through it and sunshine can be penetrate into the other size especially when it is installed as of outside wall. And also, it can be safer due to controlling room inside easier, if the strength is applicate. This study is to show some applicability after finding out the properties using the test. The test members with a size of $1,600{\times}200{\times}300{\times}9mm$ being SS41 rolled steel having THK 9mm flange while having 8,10mm and reinforced glass 12mm thickness is bonded with epoxy bond under the condition of temperature $28^{\circ}C$, humidity 50%, bonding power 24Mpa. It is show reinforced glass has 5 times of fracture stress more than the common glass but $50{\sim}150%$ difference between these 2 kinds of glass was shown. Reinforce glass did not support the original upper flange after fracture but the common glass did the upper flange after unloading. Generally reinforced glass is stronger than the common one but the common glass having a part of crack on it, compared with reinforced glass having the overall fracture could be more useful in case of needing ductility.

COMPUTATIONAL SIMULATION OF FIRE SUPPRESSION SYSTEM FOR CABINS OF SHIPBOARD ENCLOSURE (선박 거주구역용 소화시스템의 전산 시뮬레이션)

  • Jung, I.S.;Chung, H.T.;Han, Y.S.
    • Journal of computational fluids engineering
    • /
    • v.21 no.4
    • /
    • pp.40-45
    • /
    • 2016
  • The numerical simulation has been performed to predict the performance of the fire suppression system for cabin of shipboard enclosure. The present study aims ultimately at finding the optimal parametric conditions of the mist-injecting nozzles using the CFD methods. The open numerical code was used for the present simulation named as FDS (Fire Dynamics Simulator). Application has been done to predict the interaction between water mist and fire plume. In this study, the passenger cabin was chosen as simulation space. The computational domains for simulation in the passenger cabin were determined following the fire scenario of IMO rules. The full scale of the flow field is $W{\times}L{\times}H=4{\times}3{\times}2.4m^3$ with a dead zone of $W{\times}L{\times}H=1.22{\times}1.1{\times}2.4m^3$. The water mist nozzle is installed in ceiling center of 2.3 m height from the floor, and there are six mattresses and four cushions in the simulation space. The combination patterns of orifices to the main nozzle and the position to install nozzles were chosen as the simulation parameters for design applications. From the present numerical results, the centered-located nozzles having evenly combined orifices were shown as the best performance of fire suppression.

A Case Study on the Interior Color Characteristics for Common Spaces in Elderly Housing - Special Reference to Elderly Housing In Contra Costa County, California, U.S.A - (노인주거시설 공용공간의 실내색채 사례연구 - 미국 캘리포니아 콘트라 코스타군의 노인주거시설을 중심으로 -)

  • 오혜경;박민진;이지현
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.1
    • /
    • pp.70-80
    • /
    • 2004
  • The purpose of this study is to analyze the interior color characteristics of elderly housing facilities in U. S. A. For this purpose, a field survey was conducted between July 23 and July 31, 2003, visiting 10 elderly housing facilities in Contra Costa County, California. A three step analysis of the facilities involved. First, floor, walls, ceilings, base boards and doors in common spaces were examined for the color scheme using the "Pantone for Fashion and Home Color Guide" for each room. Measured Pantone numbers were converted to RGB color using "Chooser 3.0 of Pantone, Inc." Finally, the conversions were recorded as Munsell numbers. The results are as follows: First, the colors chosen for American elderly housing are high value and low chromatic colors. In many facilities, analogue colors such as BG, B, BP and Y, YR R, RP are used. Second, the colors of ceiling and wall are mainly very bright and low chromatic colors. The colors of floor are undertaking an Important role by generating major atmosphere in the America elderly housing. Third, the colors used for elderly housing are found inter-related. For example, the main color in the lobby is also used from corridor to stair and used again from lounge to dinning room as a secondary color. Fourth, it is found that accent colors are used at the beginning and end of stair and corridor outskirts in consideration of physical condition of elderly people. Fifth, there is no difference in color selection between elderly housing with low and high rental value. Preferably, more versatile colors are being chosen for elderly housing with the low rental value.he low rental value.

Features of Attention Shown at Continuous Observation of Department-Store Space (백화점 공간의 연속 주시에 나타난 주의집중 특성)

  • Choi, Gae-Young
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.6
    • /
    • pp.128-136
    • /
    • 2015
  • This research, which has been planned to appreciate the features of continuous observation of space, has applied the procedure of acquiring continuous visual information when the act of watching takes place along the time to analyze the space characteristics through the scenes and time so that the features of attention shown in the process of acquiring visual information at the time of observing continuous scenes might be estimated. For analysis of the features of continuous observation was set up the premise that the features of observation and perception vary depending on gender, when the women shops in department stores were selected as research objects. The observation features found at the time of continuous observation of selling spaces in department stores were focused on two analysis methods in order to compare the differences and characteristics of the two. The followings are the findings. First, the area with predominant observation was found to be 87.1% in both methods. It was found that the analysis of observation features by "Analysis I" was useful for inter-sectional comparison of continuous images. Second, in case of extracting predominant sections, the ceiling or the structures which are the backgrounds rarely attracted any eyes. Depending on analysis method, there was the gap of 14.3%~25.0% between observed sections. Third, in case that the hall is curved, the eyes were found to be expanded from side to side and up and down. The review of observation numbers of predominant sections makes it possible to decide whether it should be regarded as (1) unstability or (2) expanding search, and when the images are enlarged from distant view to close-range view, the weakening vanishing point results in the increase of expanded search of surroundings. Accordingly, it was found that the characteristics of images has effects on the observation features when any space was continuously observed. Furthermore, the difference of analysis methods also was found to be likely to cause big differences in the results of analyzing observation features.

A Study on Accuracy of Meteorological Information for Low Altitude Aerospace around the Airport on the West Coast (서해안 인접공항의 저고도 항공기상 정확도 연구)

  • Cho, Young-Jin;Yoo, Kwang Eui
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.28 no.2
    • /
    • pp.53-62
    • /
    • 2020
  • This study is to evaluate the accuracy of the meteorological information provided for the aircraft operating at low altitude. At first, it is necessary to identify crucial elements of weather information closely related to flight safety during low altitude flights. The study conducted a survey of pilots of low altitude aircraft, divided into pre-flight and in-flight phases, and reached an opinion that wind direction, wind speed, cloud coverage and ceiling and visibility are important items. Related to these items, we compared and calculated the accuracy of TAFs and METARs from Taean Airfield, Seosan Airport and Gunsan Airport because of their high number of domestic low-altitude flights. Accuracy analysis evaluated the accuracy of two numerical variables, Mean Absolute Error(MAE) and Root Mean Square Error(RMSE), and the cloud coverage which is categorical variable was calculated and compared by accuracy. For numeric variables, one-way ANOVA, which is a parameter-test, was approached to identify differences between actual forecast values and observations based on absolute errors for each item derived from the results of MAE and RMSE accuracy analyses. To determine the satisfaction of both normality assumptions and equivalence variability assumptions, the Shapiro-Wilk test was performed to verify that they do not have a normality distribution for numerical variables, and for the non-parametric test, Kruscal-Wallis test was conducted to determine whether or not they are satisfied.

Study on Optimum Installation of Fan in Standard Hanwoo Loose Barn (한우사 내 송풍팬의 최적 설치에 관한 연구)

  • Lee, Seung-Joo;Chang, Dong-Il;Choi, Yoon-Hyuck;Yang, Jae-Woong;Min, Byeong-Joo;Gutierrez, Winson M.;Chang, Hong-Hee
    • Journal of Biosystems Engineering
    • /
    • v.35 no.5
    • /
    • pp.350-356
    • /
    • 2010
  • The fans installed in standard Hanwoo loose barns (room size : 10 m (width) $\times$ 5 m (length)) are frequently used to reduce Hanwoo's heat stress during hot weather and to dry the wet floor. However, the most effective method of installing fans has not been suggested yet. Therefore, this study was carried out to evaluate two methods of installing fans under the ceiling of Hanwoo loose barn by using CFD (Computational Fluid Dynamics) code, FLUENT and to recommend the optimum fan installing method. The fan installation options were fan tilting angles of $45^{\circ}$ and $0^{\circ}$ (horizontal). The fans of 1 m diameter were installed at 3 m above floor. A velocity scale on 10 cm and 110 cm above floor and air flow pattern were used as the parameters to evaluate the fan installing methods. The fans tilted at $45^{\circ}$ angle produced higher wind at 10 cm and 110 cm above floor and more uniform air flow pattern, compared with the fans installed horizontally. Based on these results, fans tilted at $45^{\circ}$ angle may help to reduce Hanwoo's heat stress and will dry the floor better than fans installed horizontally. Therefore, it is suggested that the fans of 1 m diameter in a standard Hanwoo loose barn should be installed at a $45^{\circ}$ tilt angle and 3 m above floor with spacing of 5 m at the center of a room column.