• Title/Summary/Keyword: ceiling

Search Result 983, Processing Time 0.028 seconds

Fire Suppression Performance of a New Automatic Fire Extinguisher with Fusible Metal Detectors (이융성금속 응용 자동감지형소화기의 소화성능 특성에 관한 연구)

  • 박용환
    • Fire Science and Engineering
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • In general, small buildings and residence housings rely on manual fire extinguishers instead of automatic fire suppression systems, which causes bigger disasters during the absence of human-beings or in the presence of children or the olders. For this reason, simple structured and low-cost automatic fire extinguisher using fusible metal detector was newly developed and patented. In this paper, some field tests were carried out to investigate its fire suppression performance. As a result, reaction time of the detection parts varied from 2 min 19s to 7 min 20s depending upon the room size and installation position. It was suggested that to reduce reaction time within 3 minutes, fusible metals with lower melting point should be adopted and the installation location should be moved to near ceiling instead of below 1.5 m.

A Study on the Performance of a Sprinkler System with Direct-Coupled Waterworks by Full-Scale Fire Test (실화재실험을 통한 상수도 직결형 스프링클러시스템의 성능에 관한 연구)

  • Jung, Jong-Jin;Nam, Dong-Gun;Lim, Woo-Sub
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.39-43
    • /
    • 2011
  • In this research, full-scale fire test was performed on a real house for the evaluation of the performance of waterworks direct-coupled sprinkler system. The fire was set to occur as spontaneous combustion as the cooking oil overheats. The size of house is $56m^2$ and it consists of a living room, a kitchen, and a room. In order to verify the performance of waterworks direct-coupled sprinkler system, it was installed in the kitchen. The result of the test showed that the fire started from the kitchen enlarged up to its ceiling but it was soon exhausted as the sprinkler started to work. The pressure of the waterworks was 0.28 MPa when the sprinkler operated, by which it verified that fire could go out even by waterworks pressure of the general residence.

FDS Simulation and Validation on the Under-Ventilated Compartment Fires (환기부족 구획화재에 대한 FDS 해석 및 검증)

  • Ko, Gwon-Hyun;Kim, Sung-Chan;Hamins, A.;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.103-109
    • /
    • 2009
  • In this study, fire simulations on the under-ventilated compartment fires have been conducted using the Fire Dynamics Simulator (FDS Ver. 5.2) and its prediction performance on the thermal and combustion chemical characteristics has been discussed. The temperature and chemical species concentrations in the upper layer of methane, heptane, and toluene fires located in a 2/5 scale compartment based on the ISO-9705 standard room are predicted and compared with the previously published experimental data. The results showed that the FDS simulations reproduced well the temperature of the ceiling and the mixture fraction in the upper layer under the well-ventilation conditions. For the under-ventilated fires, which were taken place due to the insufficient oxygen entrainment, the prediction by the FDS significantly under-estimated the production of carbon monoxide and soot compared to the experimental data.

Analysis of the Causes of Multiple Casualties in an Electronics Factory Fire (전자공장 화재의 다수 사상자 발생원인 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.130-139
    • /
    • 2019
  • The electronics factory fire, that occurred at 15:40 on August 21, 2018, killed nine people and injured six. This study analyzes the causes of many of the casualties from the fire, and is based on fire investigation results and so on. The findings suggest that major causes included failure of the automatic alarm system to function, failure of the emergency broadcasting system to function, the fire suddenly spreading due to polyurethane foam in a ceiling on the 4thfloor, a power outage immediately after the fire started, a sprinkler system that was not working, a delay in reporting the fire, and improper management of fire facilities by a fire safety management company.

Dual Capacity Price Mechanism to Provide Stable Remuneration for Generation Capacity (전력도매시장에서의 안정적 발전용량 보상을 위한 이원적 용량가격 제도 도입 방안)

  • Kim, Yung San
    • Environmental and Resource Economics Review
    • /
    • v.25 no.1
    • /
    • pp.113-140
    • /
    • 2016
  • Achieving the two goals of providing stable remuneration and promoting market based incentive for generation capacity with only one kind of capacity price is a difficult proposition. This paper suggests a market design in which two different kinds of capacity prices are used to achieve these goals. It maintains the current capacity price that is determined administratively based on the fixed cost of the gas-turbine generator. A second capacity price is added that covers generators with higher fixed costs and lower fuel costs such as combined-cycle gas turbine, coal-powered, and nuclear generators. This second capacity price is conditional on a lower energy price ceiling and determined by the interaction of the market supply and a demand schedule derived from the optimal fuel mixed principle.

A Study on The Performance of Ventilation and Thermal Environment for a Combined Type Diffuser in a Residential Space (거주공간에 대한 급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구)

  • Lim, Seok-Young;Chang, Hyun-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • In this study, the combined-type diffuser developed by the Authors, in a previous study, was applied to a residential space. The performance of a ventilation and thermal environment, created by the use of a combined-type diffuser was compared to the pan-type diffuser widely used in apartment houses. In cooling conditions, because of the relatively high air flow rate of ceiling cassette-type air conditioners, the characteristics of airflow distribution in a room were governed by the air conditioner's airflow. In heating conditions, because of the low air flow rate of the diffuser, the characteristics of airflow distribution were governed by the buoyancy effect created by cold external walls and a hot floor. In terms of the Air Diffusion Performance Index (ADPI), which is a thermal environmental index, the result of a combined-type diffuser was greater than a pan-type diffuser in both of cooling and heating conditions. Consequently, the combined-type diffuser showed equal or superior ventilation and thermal environment performance compared to a pan-type diffuser.

Development of Precise Localization System for Autonomous Mobile Robots using Multiple Ultrasonic Transmitters and Receivers in Indoor Environments (다수의 초음파 송수신기를 이용한 이동 로봇의 정밀 실내 위치인식 시스템의 개발)

  • Kim, Yong-Hwi;Song, Ui-Kyu;Kim, Byung-Kook
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.4
    • /
    • pp.353-361
    • /
    • 2011
  • A precise embedded ultrasonic localization system is developed for autonomous mobile robots in indoor environments, which is essential for autonomous navigation of mobile robots with various tasks. Although ultrasonic sensors are more cost-effective than other sensors such as LRF (Laser Range Finder) and vision, they suffer inaccuracy and directional ambiguity. First, we apply the matched filter to measure the distance precisely. For resolving the computational complexity of the matched filter for embedded systems, we propose a new matched filter algorithm with fast computation in three points of view. Second, we propose an accurate ultrasonic localization system which consists of three ultrasonic receivers on the mobile robot and two or more transmitters on the ceiling. Last, we add an extended Kalman filter to estimate position and orientation. Various simulations and experimental results show the effectiveness of the proposed system.

Differential Item Functioning of the Oswestry Low Back Pain Questionnaire Between Participants With and Without Low Back Pain

  • Choi, Bong-Sam
    • Physical Therapy Korea
    • /
    • v.21 no.4
    • /
    • pp.40-48
    • /
    • 2014
  • Differential item functioning (DIF) based on Rasch model can be used to examine whether the items function similarly across different groups and identify items that appear to be too easy or difficult after controlling for the ability levels of the compared groups. The Oswestry low back pain disability (Oswestry) has traditionally been proved as an effective instrument measuring disability resulting from low back pain (LBP). In this study, DIF method was used to explore whether items on the Oswestry perform similarly across two different groups (participants with LBP and no LBP). A series of Rasch analyses on the 10 items of the Oswestry were performed using Winsteps$^{(R)}$ software. Forty-two participants with back pain were recruited from 3 rehabilitation hospitals in Gainesville, Florida. Another 42 participants with no LBP were recruited from several public places in the rehabilitation hospitals. Based on the DIF analysis across the two groups, several items were found to have an uniform DIF. Participants with no LBP had more difficulty on lifting and personal care items and participants with LBP had more difficulty on sleeping and social life items. For non-LBP group, a high ceiling effects (83% of participants with non-LBP) was detected, which was not be able to be effectively measured with the Oswestry items. Although 4 items of the Oswestry function differently across the two groups, all items of the Oswestry were well targeted the LBP group.

Design and Control of an Omni-directional Cleaning Robot Based on Landmarks (랜드마크 기반의 전방향 청소로봇 설계 및 제어)

  • Kim, Dong Won;Igor, Yugay;Kang, Eun Seok;Jung, Seul
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.2
    • /
    • pp.100-106
    • /
    • 2013
  • This paper presents design and control of an 'Omni-directional Cleaning Robot (OdCR)' which employs omni-wheels at three edges of its triangular configuration. Those omni-wheels enable the OdCR to move in any directions so that lateral movement is possible. For OdCR to be localized, a StarGazer sensor is used to provide accurate position and heading angle based on landmarks on the ceiling. In addition to that, ultrasonic sensors are installed to detect obstacles around OdCR's way. Experimental studies are conducted to test the functionality of the system.

Luminous Environment and Light Pollution in Gas Stations with Non-cutoff Luminaires (Non-cutoff 조명기구가 설치된 주유소의 조명환경 및 빛공해 평가)

  • Kong, Hyo-Joo;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.7-16
    • /
    • 2008
  • Lighting for gas station should be carefully designed with safety and visually attraction. Recent studies have shown that non-cutoff luminaires should not be used for gas station. duo to light pollution and energy waste. This paper aims to evaluate the luminous environment in gas station with non-cutoff luminaires. The CS-100 and Radiant Imaging Prometric-1400 were used to measure the luminance of building surface, canopy, ceiling and ground surface. The result shows that the whole luminance of various combination elements in gas station increases by rising the total luminaires of the canopy. All of the gas stations with non-cutoff luminaries produce light pollution. Some guidelines for outdoor lighting in gas station is necessary.