• Title/Summary/Keyword: ceiling

Search Result 983, Processing Time 0.024 seconds

System Development of Removing Dust and Odor from Manufacturing Process of FRP Products (FRP제품 가공시 발생하는 분진 및 악취 제거 시스템 개발)

  • Yun, Huy Kwan;Kim, Jae Yong
    • Applied Chemistry for Engineering
    • /
    • v.20 no.5
    • /
    • pp.547-552
    • /
    • 2009
  • When fiber reinforced plastics (FRP) products are manufactured, dust and odor materials are inevitably generated in a workplace. To improve the bad condition of the workshop, we developed the Hybrid Bag Filter attached activated carbon fiber (ACF) and installed the system at two companies producing FRP goods. In order to raise the efficiency of dust collection, we set the ducts both on the ceiling and at the bottom of the wall and according to the circumstances of the workshop's space, moving dust collector also adopted as a different type of flexible duct. Pulse Jet Type Bag Filter is also equipped to operate the system more effectively, for the improved fine environment because of high dust removal efficiency. Finally, we investigated the removal tendency of the dust and odor when operating the System of Hybrid Bag Filter.

A Study on the Improvement for Sensitivity Test of Flame Detectors (불꽃화재감지기의 시험기준 개선에 관한 연구)

  • Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.58-61
    • /
    • 2014
  • Flame detectors has been used more than heat & smoke detector, because this is more effective to catch fire and ceiling height in spite of high price. For upgrade to flame detector, Compare to national or abroad standard about performance test, sensitivity test, sectioning indoor or outdoor, after service and management. As a result, Europe and America have only sensitivity test, no have not operation test and sectioning indoor & outdoor. In performance test, action is put to focus to credit and durability, Not operation test is to be able to tune the sensitivity to match the environment of the site. Also, we need code about aftercare, quality assurance responsibility and implement special detector institution by Certificate Authority implement.

Smoke Density and Operation of Fire Detector Influenced by Air Stream (기류순환이 연기농도와 감지기 작동에 미치는 영향)

  • 이복영;이병곤
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.28-32
    • /
    • 2002
  • The performance based design in fire detection system, the effect of high airflow and dilution of smoke produced in any fire situation serve to increase the response time of point-type smoke detectors. This study investigated the smoke density of ceiling, under the air stream and in normal status when fire type is smoldering fires. The result of study, smoke generated in the fire was swept away from nearby spot type smoke detector which failed to actuate because dispersed in diluted form around the room. The concept of performance based design in fire detection system of protected area influenced by high airflow provided the need of active fire detection system such as air sampling smoke detection system.

Full-Scale Test of Smoke-Control Performance of a Subway Tunnel (지하철 본선터널 제연성능 실물 실험)

  • Park, Won-Hee;Lee, Duck-Hee;Jung, Woo-Sung
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.94-102
    • /
    • 2011
  • Hot smoke test is done in a subway tunnel. Alcohol trays of 1.0 MW and smoke generators are used for generating hot smoke. The fans equipped with the tunnel are successively run 9 min after smoke generation. It is verified how hot smoke is controlled by fans. Velocity and direction of flow, temperature and smoke density are measured and analyzed for smoke control performance of the tunnel with fans and analyzed from the fire-safety-point of view. Velocity of smoke flow is obtained by using measured velocity and temperature at the ceiling of the tunnel. The time when smoke-control flow is builded up is different for the different positions. Velocity distributions at various positions will be used for the boundaries and the comparison data in numerical simulations for evaluation on smoke-control facilities of subway tunnel.

Experimental Study of being vehicle cockpit module BSR Noise considering the deterioration condition of the module unit (모듈 단위 열화조건을 고려한 자동차용 칵핏 모듈 이음(BSR Noise)에 대한 시험적 고찰)

  • Yi, Chulhyun;Yang, Jeongmin;Cho, Jinho;Lee, Wonku;Woo, Changsu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.791-795
    • /
    • 2014
  • In this paper, in order to impart the aging condition of the parts, by configuring the cycle of temperature from low temperature was performed by applying the aging conditions for vehicle cockpit module. The reason for the selected modules of the cockpit vehicle parts, because the joint occurrence typical components of the room component is a first module and ceiling cockpit module. After setting the excitation profile using the BSR exciter only that this is for the module degradation after the initial and grasp the change in the dynamic characteristics of the modules based on the before and after deterioration may be made in the module, grasp the noise generating position I measured the noise and proximity. Was also visualized on the position of the joint is generated using a sound camera to objective results occurring where the joint is selected through subjective evaluation.

  • PDF

Development of Dome-Type Cold Storage Facility Using 3-D CFD Simulation (3차원 CFD 시뮬레이션을 이용한 돔형 저온저장고 개발)

  • 양길모;고학균;홍지향
    • Journal of Biosystems Engineering
    • /
    • v.28 no.1
    • /
    • pp.35-44
    • /
    • 2003
  • This study was conducted to develop proper model for cold storage facility that could of for uniform heat movement and air movement f3r green grocery and improve improper design of the existing container-type cold storage facility. For that reason, new model(dome-type) cold storage facility was developed using 3-D CFD(computational fluid dynamics) simulation. The size was 6m${\times}$6m${\times}$5m. Its size and configuration were same to simulation model. Unit cooler was designed to send cold air in 4 side ways. A dome-type cold storage facility showed uniform distributions of air temperature and velocity because cold air was forced to move down along the ceiling and the wall and then circulated to the unit cooler from the central part of the floor. Dome-type cold storage facility also showed by low wind velocity, below 1 m/s that could minimized cold damage and quality deterioration.

A Study on the Korean traditional interior space and major elements in contemporary apartment (아파트 내부에 나타난 한국전통 실내 공간의 특성 및 구성 요소에 관한 연구)

  • 오혜경
    • Archives of design research
    • /
    • v.11
    • /
    • pp.72-81
    • /
    • 1995
  • The purpose of this study was investigate the consistency of Korean traditional space in apartment. Fifty-two apartments and its dwellers were selected for field survey research and questionnaire. The major findings were summarized as follows: First, the space layout which has its origin in Korean traditional house was found in contemporary apartment and favored than that of western apartment. Second, among the Korean traditional space characteristics, the openness and closeness were found between the living room and room, living room and dining room, dining room and kitchen. Third, the heating system has been being changed from radiator to on-dol. Also favored finishing materials were revealed on-dol wood flooring and picture window for the living room, jang-pan flooring and Korean lattice window for the master room, wall covering for every wall and ceiling.

  • PDF

Evaluate Changes in Soil Chemical Properties Following FGD-Gypsum Application

  • Lee, Yong-Bok;Bigham, Jerry M.;Kim, Pil-Joo
    • Korean Journal of Environmental Agriculture
    • /
    • v.26 no.4
    • /
    • pp.294-299
    • /
    • 2007
  • Natural gypsum has been used as a soil amendment in the United States. However, flue gas desulfurization (FGD)-gypsum has not traditionally been used for agricultural purpose although it has potential benefit as a soil amendment. To expand use of FGD-gypsum for agricultural purpose, the effect of FGD-gypsum on soil chemical properties was investigated in the field scales. Application rates for this study were 0 (control), 1.1, and 2.2 Mg ha-1 of FGD-gypsum. After two year application, the soil samples were taken to 110 cm depth and sub-sampled at 10 cm intervals. The heavy metal contents in FGD-gypsum were lower than ceiling levels allowed by regulations for land-applied biosolids. Soil pH was not largely affected by FGD-gypsum application. Although degree of calcium (Ca) saturation in surface horizons increases only slightly with respect to the control, there is a clear decrease in exchangeable aluminum (Al). FGD-gypsum clearly increases the soil electrical conductivity (EC) with increasing application rate. Water-soluble Ca and sulfate is increased with FGD-gypsum application and these ions moved to a depth of at least 80 cm after only 2 years. We conclude that surface application of FGD-gypsum can mitigate toxicity of Al and deficiency of Ca in subsoil of acid soil.

Determining the Harest Time for Maximum Yield and Qualty of Ochardgrass Swards (Orchardgress 단파초지의 최고생산과 질적향상을 위한 취확적기의 결정)

  • Chang, Nam-Kee;Lee, Sung-Kyu;Kim, Sung-Ha
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.3 no.2
    • /
    • pp.86-91
    • /
    • 1983
  • The harvest schedule for maximum total yield and quality of orchardgrass sward was studied on the basis of theoretical analysis due to Chang's total yield equation. Harvesting at the 10% bloom stage of morphological development of orchardgrass swards was selected as a criterion which provided highest dry matter (DM) yield in conjunction with high and consistent levels of in vitro dry matter digestibility (IVD) and crude protein contents (CP) from harvest to harvest. However, since orchardrass after the 1st cutting do not bloom, the harvest time for the maximum yield and quality of orchardgrass swards is replaced by the three should time of the ceiling leaf area index (LAI).

  • PDF

Smoke Movement by a Fire in an Enclosure (밀폐 공간내에서의 화재에 의한 연기의 유동)

  • 노재성;유홍선;김충익;윤명오
    • Fire Science and Engineering
    • /
    • v.10 no.3
    • /
    • pp.10-18
    • /
    • 1996
  • In foreign country such as USA and Japan, considerable research has been done regarding the spread of smoke in room of fire involvement by using computer. but, in our country it has not been, so, this paper presents a detailed qualitative description of phenomena which occure during typical fire scenarios through numberical analysis. The governing equations are solved by using FVM method with non-staggered grid. The SIMPLE method for pressure-velocity couple and power-law scheme for convention terms are used. It shows that a plume is formed, hot plume gases impinge on the ceiling and they spread across it. then, it eventually reaches the bounding walls of the enclosure. It takes 20s for smoke to fill the enclosure.

  • PDF