• Title/Summary/Keyword: ceiling

Search Result 983, Processing Time 0.033 seconds

Numerical Simulation of Ventilation Performance in a Dry Room (극저습 공조실의 환기성능에 대한 수치적 모사)

  • Choe, Seok-Ho;Lee, Gwan-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.4
    • /
    • pp.594-603
    • /
    • 2002
  • The characteristics of moisture ventilation in a dry room were studied numerically The effect of three important parameters: position of outlets, aspect ratio($\beta$) of horizontal plane and air exchange rate(N), was analyzed by using the scales of ventilation efficiency. The ventilation performance was evaluated by varying the aspect ratio and air exchange rate in the four types of outlet position. It was shown that the ventilation performance was improved by decreasing the aspect ratio in the longitudinal arrangement of outlet. The highest ventilation performance was determined when $\beta$ was 4 in the transverse arrangement of outlet. Regardless of the aspect ratio, the ceiling arrangement of outlet played more dominant effect on the ventilation efficiency than the floor arrangement. In every type and aspect ratio, the increase of air exchange rate to improve ventilation performance was appropriate up to N=60 /h.

A Study on the Improvement of Rules of Origin in the Korea Foreign Trade Act in the Global Trade Circumstances (국제무역환경 변화에 따른 대외무역법 원산지제도의 개선방안에 관한 연구)

  • Park, Kwang-So;Lee, Byung-Mun;Oh, Won-Suk
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.41
    • /
    • pp.267-292
    • /
    • 2009
  • It is a right time to improve the Korea Foreign Trade Act(KFTA) as a fundamental law on Rules of Origin(RoO) in the global trade circumstances which are summarized FTA and WTO. The KFTA's RoO constitutes the labelling system of the Country of Origin, the criterion of it, the issuing of certificate of origin and the punishing offender mainly around the importing goods. This study has focused on the problems of KFTA's RoO at the macro and practical level, and proposed the programs to improve the KFTA's RoO about importing, exporting and domestic production goods. KFTA need to create a purpose clause to protect consumers and industries also, and has to be located a general and top position in the RoO of Korea. In the concrete, the labelling system of the Country of Origin has to set limited in the point of minimum necessity view. The criterion of the Country of Origin also has to improve the wholly obtained criterion, the changing in tariff classification criterion, value added criterion and processing operation criterion to harmonize WTO Rules of Origin and FTA Rules of Origin. The punishment ceiling against offender has to raise to guarantee the effectiveness of RoO.

  • PDF

An Experimental Study of Smoke Movement in Tunnel Fire with Natural and Forced Ventilations (자연 및 강제 배기시의 터널 내 연기거동에 관한 실험적 연구)

  • Hwang Cheol-Hong;Yoo Byung-Hun;Kum Sung-Min;Kim Jung-Yup;Shin Hyun-Joon;Lee Chang-Eon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.6 s.237
    • /
    • pp.711-721
    • /
    • 2005
  • In order to design of emergency ventilation systems, the smoke movements in tunnel fire with natural and forced ventilation were investigated. Reduced-scale experiments were carried out under the Froude scaling with novel fire source consisting many wicks. Temperature profiles were measured under the ceiling and vertical direction along the center of the tunnel and poisonous gases were measured at emergency exit point in the natural ventilation case. In forced ventilation, temperature profiles were measured with various flow rate to obtain critical velocity. The results showed that the interval of emergency exit having 225m was estimated reasonably through the measurements of temperature variation and poisonous gas in the natural ventilation. In the case of forced ventilation, the temperature distribution near fire source is remarkably different from that of natural ventilation. Also, the critical velocity to prevent upstream smoke flow has the range of 0.57m/s between 0.64m/s. Finally, it was also identified that although the increase of flow rate can suppress the backward flow of smoke to upstream direction, brings about the increase of flame intensity near stoichiometric fuel/air ratio.

A Study on Reinforced Concrete Beams with Perforation (철근콘크리트 유공보에 관한 연구)

  • Park, Kyong-Ho
    • Journal of Industrial Technology
    • /
    • v.21 no.A
    • /
    • pp.7-14
    • /
    • 2001
  • In building structure, the story height can be minimized by providing openings in beams which serves for the utility equipments passing through. The dead space in false ceiling thus put to economical use in the form of a substantial reduction in materials and construction cost. In the case of steel structure, there is no critical risk in the structural strength because of reinforcing methods of stiffness and steel plate but in the case of reinforced concrete structure, proper provision should be made in designing these openings, otherwise there is a risk that these opening will possibly weaken the structural strength of the building frame to a critical degree. In this paper, for the numerical analysis of the reinforced concrete beams with circular opening in the web, expecting stress concentration of the circular opening, reinforcing methods were studied. Twenty test pieces with each different reinforcing methods were tested and their resisting forces were defined. From the numerical analysis and test results, the followings were founded;(1)high shear stress distributed around the openings reduce the shearing strength, (2)from the numerical analysis, the maximum tensile stress occurred at opening nodes 1,7, these phenomena were agreed with the test results, (3)reinforcing method around openings have to carried out for stopping diagonal cracks, and (4)both, by steel plate, and wire mesh, are effective reinforcing methods.

  • PDF

Construction History of the Old House "IMCHEONGGAK" in Andong and Estimation of its Original Structure -Focused on the 'Inner chamber' and the 'Sarang section'- (안동 "임청각(臨淸閣)"의 건축 이력과 원형 가구(架構) 추정 -사랑채와 안채를 중심으로-)

  • Lee, Jong-Seo
    • Journal of architectural history
    • /
    • v.25 no.2
    • /
    • pp.31-44
    • /
    • 2016
  • Imcheong-gak[臨淸閣] was a familial residence constructed in the early half of the Joseon dynasty period. It was partially destroyed by a fire during the 1590s war[壬辰倭亂] with the Japanese, and another fire that was caused between 1631 and 1634. The inner chamber[An-chae] and the Sarang section[Sarang-chae] today is the result of a partial reconstruction that took place back in 1626 and again around 1634. The residence also went through some changes because the new Ondol[溫突] heating system had to be applied to the structure. Based upon sections that remain in their original forms, we can presume that the Imcheong-gak residence originally had an inner chamber which was composed of the following elements: A main structure which was built upon a foundation featuring a Matbae[맞배] roof, two "Ik'rang[翼廊, flank]" sections on the East and West sides of the inner chamber, and a "Haeng'rang[行廊, passage]" structure on the opposite side of the main structure. Unlike the main structure, other portions of the inner chamber were all built directly upon the ground, and showed multiple stories, with Matbae roofs of their own. We can also assume that the Sarang section in the south would have been a pre-Ondol[溫突] bedroom, with a Board platform[板房] and a Gomi-ceiling[Gomi-banza] fashion.

A Study on the Space Determinants of the Medieval Plaza (중세광장의 공간결정요소에 관한 연구)

  • Nam, Ho-Hyeon;Min, Sang-Choong
    • Journal of architectural history
    • /
    • v.17 no.4
    • /
    • pp.83-95
    • /
    • 2008
  • This study was firstly to reflect upon the background of the generation and the urban spatial value and significance of the medieval plaza. The main aim of this study was to extract the spatial determinants which give the great influence on the formation of the medieval plaza and in addition the endogenous rules and aesthetical grounds regarding the respective elements. Especially they could be applied to the design guideline. They are dimension(volume and scale), shape, elevation as the morphological elements and enclosure, proportion, grade difference, spatial sequence and plaza group as the spatial determinants and visual sequence, visual or spatial boundary, approaching axis and perspective effect as the aesthetic and visual elements and function(use), human behaviour as the social-behavioral elements and otherwise, for instance, plaza furniture, ground decoration and vegetation. This study was intended to analyze each elements based on the classical historical literatures and to suggest the planning conditions for composing the ideal plaza referring to the cases and literature review on the medieval plaza and finally is expected to contribute to the plaza design methodology.

  • PDF

Localization for Mobile Robots using IRID(InfraRed IDentification) (IRID를 이용한 이동로봇의 위치 추정)

  • Bae, Jung-Yun;Song, Jae-Bok;Lee, Soo-Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.9
    • /
    • pp.903-909
    • /
    • 2007
  • Mobile Robots are increasingly being used to perform tasks in unknown environment. The potential of robots to undertake such tasks lies in their ability to intelligently and efficiently search in an environment. To achieve autonomous mobile robot navigation, efficient path planner and accurate localization technique are the fundamental issues that should be addressed. This paper presents mobile robot localization using IRID(InfraRed IDentification) as artificial landmarks. IRID has highly deterministic characteristics, different from RFID. By putting several IRID emitters on the ceiling, the floor is divided into many different sectors and each sector is set to have a unique identification. Dead-reckoning provides the estimated robot configuration but the error becomes accumulated as the robot travels. IRID information tells the sector the robot is in, but the size of the uncertainty is too large if only the IRID information is used. This paper presents an algorithm which combines both the encoder and the IRID information so that the size of the uncertainty becomes smaller. It also introduces a framework which can be used with other types of the artificial landmarks. The characteristics of the developed IRID and the proposed algorithm are verified from the simulation results and experiments.

A Study on the Binary Appearance in Pseudo limestone Cavern (이차원의 위종유동에 관한 동굴미지형학적 연구 -천연기염물 236호로 지정된 황금굴을 중심으로-)

  • 한국동굴학회
    • Journal of the Speleological Society of Korea
    • /
    • no.66
    • /
    • pp.45-57
    • /
    • 2005
  • This Paper is a study on the duality of speleothem that appeared in 'Hyeob Jae Cave' which is designated as the natural monumen. No.236. It is located at Hyeob Jae Ri, Hanrim Eub, Bug Je-ju Gun, Je-judo. The findings are as follows. 1. The distribution range of the shelly sand which has maximum thickness of $10m{\pm}$ and average of $3m{\pm}$ was $3.2m^2$. 2. The desert hollow acted to promote the speleothem deposits in the lava tunnel with lava mound formed by lavapilz and artificial breaksand wall. 3. The main component of the pseudo limestone cavern was carbonate Calcium from shelly sand. And the deposition of speleothem in the Cave was accelerated after the volcanic erupsion of Biyang island in 1002. A.D. 4. The secondary depositions of Calcite recognized as speleothem up to now it can be used for the pseudo karst in general. 5. It seems that the variety of the cave deposits is decided depending upon the geology, land form, climate, vegetations and the structural environmental factors. 6. It seems that the wondering development of accretionary deposits caused by encrusting has a close relation with intermittent seepage of ground water. 7. Finally, we can acknowledge the coexistent duality of speleothem by shelly sand along with the joint and the lava stalactites formed at the same time with the lava tunnel on the ceiling where there was no seepage.

The Proposal of a New Drainage System without Incline of Piping and Experiment on Drainage Flow Characteristics (구배가 없는 신배수시스템의 제안 및 배수유동 특성에 관한 실험적 연구)

  • Cha Young-Ho;Yee Jurng-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.452-458
    • /
    • 2005
  • In Korea, pumping pipe using gravity way by water is most popular method in drainage system. But, it is difficult to repair a drainpipe in this method because the drain pipe diameter is increased as using this method. In this research, we propose a new drainage system. The system aim for an adaptedness with buildings, freedom of plan, construction and renewal in water pipe equipments, etc. The new system is not need of incline of piping, and it uses drainage power that is changed potential energy by high velocity flow as making Siphonage at vertical pipe. Therefore, the diameter of piping can decreased than existing piping system established in the ceiling. Also because connecting position will be located at the lower part, it is changed the potential energy of drainage to the high velocity flow. In addition, drainage will be smooth because the fixture drain is linked by each drain pipes.

Study on Characteristics of Heat Release Rate in Compartment of Building for Scenario of Smoke Management (건축물 제배연시나리오 작성을 위한 구획실 발열특성 연구)

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.398-403
    • /
    • 2009
  • The theoretical bases on characteristics of heat release rate in compartment of building for scenario of smoke management are introduced and the numerical applications to simple compartment model are carried out. The growth stage which is important for smoke management design is modelled as t-squared fire curve including fire growth coefficient with related to growth rate. The conditions for the happening of flashover is presented such as $600^{\circ}C$ of temperature or $20kW/m^2$ of radiation heat flux. After the flashover happen, the fire in compartment changes to fully developed fire having the characteristics of ventilation-controlled fire. As the result of numerical analysis to simple compartment model, the time to reach 900K under ceiling for condition of medium growth is twice for condition of fast growth.

  • PDF