• Title/Summary/Keyword: ceiling

Search Result 983, Processing Time 0.027 seconds

Field Survey on the Structure and Manure Treatment of Two-Storey and Sawdust Pig Houses in Korea (국내 2층 돈사와 톱밥돈사의 구조 및 분뇨처리 실태조사)

  • Jeong J. W.;Yoo Y. H.;Song J. I.;Kim T. I.;Jeon B. S.;Yang C. B.
    • Journal of Animal Environmental Science
    • /
    • v.11 no.3
    • /
    • pp.169-176
    • /
    • 2005
  • The farm house structure, ventilation system and manure treatment of two-storey buildings and sawdust pig houses were surveyed and analyzed. Based on the data for ten selected farms in five provinces during eight months, the goal is to eventually establish a standard two-storey pig house. Manure treatments were composting, slurry and activated sludge in two-storey pig houses, while fermentation method was done in sawdust pig house. The depth of sawdust as a litter material were 10 to 60cm, with a duration of 1/2, 1, 3 and 6 months, respectively. The ventilation systems were the mechanical type in two-storey pig houses and natural system in the sawdust pig house. Side wall in the two-storey pig house was enclosed with insulation materials such as block, colored metal sheet and sandwich panels. The minimum ceiling height in the first floor of the two-storey pig house was 2.0m and the maximum was 3.0m. On the second floor, ceiling height ranged from 2.0 to 2.7m. The construction cost in the two-storey systems were $700\~140$, and sidewall curtain systems were $30\~40$ thousand Won/pyung.

  • PDF

A Study on the Standard Drawings of Seoul Middle School Architecture in 1975 (1975년 서울시 중학교 표준설계도에 관한 연구)

  • Lee, Jeong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2497-2504
    • /
    • 2013
  • This study aims to analyze the 'Standard Drawings for School Facilities' issued by Seoul Education Committee in 1975 because it is the early example for middle school architecture. The results of this study are summarized as follows 1) In general trend of single-corridor type block plan, there are also changes in floor plan like no-corridor type block plan, $9.9{\times}6.6m$ classroom unit for the better daylight condition, built-in storage for students. 2) As for elevation design, it is characterized as daylight-oriented, functional exterior for without making full use of design elements. 3) Standardized dimensions are used as a rule in the height of story, ceiling, window sill and etc. Transitional characteristics of the early RC school architecture are found in exposed ceiling, incomplete insulation structure and mixed use of wood framed floor of earlier type. 4) Contrast to main school building, gymnasium shows the intend to express the symbolism of school architecture with diverse elevation design elements and the plasticity of building mass. 5) Separated plan of toilet and night-duty building also show the transitional characteristics. As conclusion, though showing the stereotyped school architecture, on the other hand, 'Standard Drawings for School Facilities' (1975) makes it possible to see the way of coping with the demands for school architecture in that time and the transition of school architecture. This is the main value of it as the material for the studies related to the history of educational facilities.

A Study on the Accelerated Life Test of BLDC Motor in Ceiling Mounted Digital Signage Rotating System (천정 거치형 디지털 사이니지 회전 시스템의 BLDC모터 가속수명시험에 관한 연구)

  • Kim, Ki-Hong;Kwon, Soon-Hong;Kwon, Soon-Gu;Park, Jong-Min;Kim, Jong-Soon;Jung, Sung-Won;Choi, Won-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.3
    • /
    • pp.141-147
    • /
    • 2018
  • In a time when product development cycles are getting shorter and shorter, many companies are making efforts to develop products with high reliability in a short period of time, accelerated life test is widely used as a method to quickly evaluate reliability. Accelerated life test reduces the test life or the life of the product from the observed data by shortening the lifetime of the product or abruptly lowering the performance under the worse condition than the actual condition in order to shorten the test cost or the test time. In this paper, BL3640A-06P+RB35, DC12V model, which is used in the support device of an automatic rotation type digital signage, which display various information such as textures and images on a display screen in a public place or a commercial space, BLDC motors were subjected to a constant stress test and at the rotational speed of 1rpm, $180^{\circ}$ rotation and reverse rotation under actual use conditions, the stress was imposed on the rotating speed of 2rpm and the weight of the actual installed product from 22.2kgf to 10kgf were installed. The lifetime of the actual use environment condition is 23,545 hours and the rotation speed is accelerated. The life time of the acceleration condition with the additional weight is 1,380 hours. The acceleration factor is calculated as 17.06, the one year guarantee test day is 235 days to 14 days, of the period from 470 days to 28 days, and the third year from 704 days to 42 days. The test date of the BLDC motor was tested on the shortened test date, and the rotational speed and the current value were measured. It is found that there is no defect even if it operates as the test date corresponding to the specified one year warranty period and the 3 year accelerated life test which is experimented. Using the statistical technique of the regression analysis the expected time for the motor to defect to #4 samples was 20 years.

Study on the Manufacturing Technology of Mural Tomb in Goa-dong of Daegaya Period (대가야 고아동 고분벽화 제작기술에 관한 연구)

  • Lee, Hwa Soo;Lee, Han Hyeong;Lee, Kyeong Min;Han, Kyeong Soon
    • Journal of Conservation Science
    • /
    • v.30 no.4
    • /
    • pp.457-466
    • /
    • 2014
  • Rigorous analysis was performed to identify the structure and materials of the murals to study techniques used on mural tombs of ancient Daegaya era(6th century). The murals were painted by applying mortar on the walls and the ceiling after building a stone chamber and creating ground layers on mortar layers. Mud was applied on most of the mortar layers on four sides of the walls except the ceiling. Sand was not used in mortar but was made of materials with pure calcium substances. In addition, shells in irregular sizes with incomplete calcination were mixed; and the mortar's white powder was inferred as lime obtained by calcination of oyster shells. Kaolinite($Al_2Si_2O_5(OH)_4$) was used in the ground layer, Cinnabar(HgS) was used for red pigment, Malachite($Cu_2CO_3(OH)_2$) for green and Lead white($PbCO_3{\cdot}Pb(OH)_2$) for white. Mud plaster was applied on the mortar and was composed thinly and densely using clayey of particle size smaller than that of medium sand. It was assumed that the finishing was for repair after long time had passed since the mortar layer came off. Using lime made with oyster shells as mortar is unprecedented in ancient Korean mural tombs and its durability was very poor, suggesting that Gaya's mortar production technique was relatively behind compared to that of Koguryo's in the same era.

A Study on Stabilizing Container Terminal Market in Busan Port (부산항 항만하역시장 안정화 방안에 관한 연구)

  • Ryoo, Dong-Keun;Choi, Jin-Yi;Kim, Tae-Goun
    • Journal of Navigation and Port Research
    • /
    • v.36 no.10
    • /
    • pp.895-904
    • /
    • 2012
  • Today, the competition for hub-port is getting fierce and the shipping liners have enjoyed the increased bargaining power over the terminal operators through the mergers & acquisitions (M&A) and strategic alliances. This result leads the competition among terminal operators to attract liner companies and cargoes in their terminals. In demand side, however, there is a limited container cargo volume to handle because of a steady growth of cargo traffic. While, in supply side, continuous development of port terminals increased more competition among ports or terminals for cargoes. In particular the terminal operating market of Busan port is distorted because of the cargo competition between Busan North-port and Newport. The main purpose of this study is to suggest the stabilization measures of container terminal operating market in Busan port through analysis of the terminal operation market structures and market survey analysis method. For stabilizing the container terminal market, this study suggests the improvement of the legal and institutional system such as improvement in determining and reporting system of stevedoring tariff, establishment of fair competition rules etc., the introduction of port pooling system and adoption of volume-linked terminal lease system with cargo volume ceiling system for each terminal operator.

An Experimental Study of Smoke Movement in Tunnel Fires with Natural Ventilation (터널 화재시 자연 배기에 의한 연기 거동에 관한 실험적 연구)

  • 이성룡;김충익;유홍선
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.1-6
    • /
    • 2001
  • In this study, reduced-scale experiments were conducted to understand smoke movements in tunnel fires with the natural ventilation. The 1/20 scale experiments were conducted under the Froude scaling since the smoke movement in tunnels is governed by buoyancy force. Three cases of experiments, in which a natural vent location varied from 1 m, 2 m and 3 m from the fire source symmetrically, were conducted in order to evaluate the effect of the position of ventilation systems on smoke movement. In case of a poo1 whose diameter is 4.36 cm, the temperature of smoke layer passed through the vent was maintained 7~$8^{\circ}c$ less than that of smoke layer without a vent. In case of a pool whose diameter is 5.23 cm, the average velocity passed through the vent was decreased when it was close to the fire source. And the maximum delay time was 3.86s. In CASE 1, the ceiling temperature was decreased by approximately 8$^{\circ}C$ and the vertical temperature was decreased by approximately $7^{\circ}c$. In CASE 2, both ceiling and vertical temperature wert decreased by $3^{\circ}c$ and in CASE 3, they were decreased by $2^{\circ}c$ each. It was confirmed that the thickness of smoke layer was maintained uniformly under the 25% height of tunnel through the visualized smoke flow by a laser sheet and the digital camcoder.

  • PDF

The Third Version of the Copenhagen Psychosocial Questionnaire

  • Burr, Hermann;Berthelsen, Hanne;Moncada, Salvador;Nubling, Matthias;Dupret, Emilie;Demiral, Yucel;Oudyk, John;Kristensen, Tage S.;Llorens, Clara;Navarro, Albert;Lincke, Hans-Joachim;Bocerean, Christine;Sahan, Ceyda;Smith, Peter;Pohrt, Anne
    • Safety and Health at Work
    • /
    • v.10 no.4
    • /
    • pp.482-503
    • /
    • 2019
  • Introduction: A new third version of the Copenhagen Psychosocial Questionnaire (COPSOQ III) has been developed in response to trends in working life, theoretical concepts, and international experience. A key component of the COPSOQ III is a defined set of mandatory core items to be included in national short, middle, and long versions of the questionnaire. The aim of the present article is to present and test the reliability of the new international middle version of the COPSOQ III. Methods: The questionnaire was tested among 23,361 employees during 2016-2017 in Canada, Spain, France, Germany, Sweden, and Turkey. A total of 26 dimensions (measured through scales or single items) of the middle version and two from the long version were tested. Psychometric properties of the dimensions were assessed regarding reliability (Cronbach α), ceiling and floor effects (fractions with extreme answers), and distinctiveness (correlations with other dimensions). Results: Most international middle dimensions had satisfactory reliability in most countries, though some ceiling and floor effects were present. Dimensions with missing values were rare. Most dimensions had low to medium intercorrelations. Conclusions: The COPSOQ III offers reliable and distinct measures of a wide range of psychosocial dimensions of modern working life in different countries; although a few measures could be improved. Future testing should focus on validation of the COPSOQ items and dimensions using both qualitative and quantitative approaches. Such investigations would enhance the basis for recommendations using the COPSOQ III.

Scientific Conservation Treatment of Artifacts Collected from the Lime-soil Mixture Barrier Tombs Excavated from the Site of a Public Residential Area in Godeung-dong, Seongnam (성남 고등 공공주택지구 출토 회격묘 과학적 보존처리)

  • Kim, Woungshin;Jeon, Juyeon;Kim, Beomjun;Han, Minsoo;Lee, Minhye
    • Conservation Science in Museum
    • /
    • v.22
    • /
    • pp.53-68
    • /
    • 2019
  • Two lime-soil mixture barrier tombs were excavated from the tomb complex of the Woo Family of the Danyang Wu clan dating to the Joseon dynasty in Godeung-dong, Seongnam-si, Gyeonggi-do. Relevant records offer information for more precisely dating these tombs and identifying their occupants. Tomb No. 4, in which a married couple was interred, has a corbeled square ceiling and inscriptions and paintings on its outer walls. The conservation treatment and an infrared inspection revealed that they were intended to express mourning. Tomb No. 6 has a corbeled rectangular ceiling and a single individual interred within. As the basic structure of the tomb was partially damaged in the process of disassembling it while moving the burial site, it was planned to exhibit the tomb outdoors after the remains and relics are collected. However, as the conservation treatment revealed the presence of funeral fans and pitch, and since the remaining structure clearly demonstrates the features of lime-soil mixture barrier tombs from the Joseon dynasty, the plan was changed following a meeting of an advisory council that decided in favor of presenting the tomb indoors. According to the analysis, the pitch is assumed to be resin of a rather low purity due to the immixture of foreign substances. The two tombs are expected to serve as important materials for related research, such as changes by period in the forms of Joseon-era tombs.

Conservation Environment for Mural Tomb in Goa-ri, Goryeong (고령 고아리 벽화고분의 보존환경 연구)

  • Jeong, Seon Hye;Lee, Hyun Ju;Lee, Min Young;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.33 no.3
    • /
    • pp.189-201
    • /
    • 2017
  • This study focused on the Gaya mural tomb located in Goa-ri, Goryeong-gun, North Gyeongsang Province, Republic of Korea. Environmental factors such as ambient temperature, relative humidity and surface temperature, and microbial distribution on mural tombs were monitored for one year to gather data on the conservation environment of the mural tombs. The average internal temperature difference with reference to the ambient outer temperature was observed to be $11.7^{\circ}C$ for the monitoring period and the internal temperature of the tomb was found to change periodically every one or two months in response to the outer temperature. The highest temperature was observed in September and the lowest in March. The relative humidity in the mural tomb remained constant at 100%. Between December and April, condensation occurred on the ceiling of the main room of the tomb, where the murals are located. On the ceiling of the aisle, the condensation occurred throughout the year. The inside and surface wall were isolated from microorganisms, which could grow when a suitable growth environment suitable is established. Based on microbial growth temperature conditions, risk periods of microbial hazards were established, where in the period from August to October was identified as the most dangerous.

Development of Image Quality Measurement Method of Coronary Angiography Using Image Analysis Program (영상 분석 프로그램을 이용한 관상동맥 혈관 조영상의 화질 측정 방법 고안)

  • Seo, Young-Hyun;Song, Jong-Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.111-120
    • /
    • 2020
  • Research should be actively conducted for the ability of X-ray equipment and Retrospective image analysis of X-ray equipment used in hospitals. Retrospective image analysis of X-ray machines, CT and MRI of radiology and medical equipment has been actively conducted. However, image quality measurement using angiography equipment of angiography room is mostly measured with phantom, and image quality measurement on image after being taken by actual patient is insufficient and researches on accurate image quality measurement method are remarkable. It is in short supply. Therefore, through this study, the researcher devised a method to measure the image quality of the acquired image after coronary angiography, and to provide a high quality image to the operator. The equipment and programs used were angiographic examination equipment (Axiom Artis Zee Ceiling) and Image J program. Subjects were images automatically saved in PACS program after coronary angiography.For image quality measurement, selected the AP Caudal 30° image that show the LCA vessel well and the LAO 30° image that show the RCA vessel well during the coronary angiography. In order to measure the background and ROI of the selected image by selecting an image, a criterion on how to find and measure a section where the overlap of the shadow, such as blood vessel, liver and lung is minimized, is presented. In conclusion, there is no exact standard for analyzing an image quality measurement method of angiography image. Therefore, in order to provide quality images to the practistioners, not only the technicians of the equipment but also the users who actually use them should become researchers and conduct research on image quality measurement in various ways. Thus, it is expected to provide excellent images to patients.