• Title/Summary/Keyword: ceiling

Search Result 983, Processing Time 0.028 seconds

Analysis of Airflow Characteristics in an Enclosed Nursery Pig House (무창자돈사의 공기유동 특성 분석)

  • Song, Jun-Ik;Choi, H.L.;Yang, C.B.;Kim, H.T.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.1
    • /
    • pp.107-114
    • /
    • 2005
  • Experiments were carried out to evaluate the air speed distribution of an enclosed nursery pig bay in summer and winter. The data taken by experiments were compared to validate with the calculated air speeds by a commercial CFD code, FLUENT. Air basically enters into the bay through perforated circular ducts overhanged on the ceiling, leaves through a exhaust fan attached on the end-wall of the bay. Air speeds were measured as 2 ${\sim}$ 2.5 mls at the perforated holes in the duct in winter and 7 mls in summer. The validation showed that a CFD simulaton is one of feasible methods to predict airspeed distribution in the nursery pig bay.

A Study on the Characteristics of the Interior Design of the Apartments in Busan - Focused on the living rooms of apartment units in modelhouse - (부산지역 아파트의 실내디자인 특성에 관한 연구 - 모델하우스의 거실공간을 중심으로 -)

  • 윤지영
    • Korean Institute of Interior Design Journal
    • /
    • no.32
    • /
    • pp.47-54
    • /
    • 2002
  • This study attempts to analyze the characteristics of interior design of the apartments in Busan that people will reside since 2001 and to find out the effects of minimalism in the interior space. The companies which are in construction of the apartments of more than 50 Pyung were selected, and the design of the living rooms of their model houses were analyzed in terms of the floor plans, architectural elements, furniture and lightings. The results reveals that the living rooms of the newly-distributed apartments in Busan show similar design characteristics without distinctive differences among the companies. The new trends provide a flexible wall which makes it possible to manipulate the number of rooms according to the family preference, art-wall design in one-side of the walls and a coffered ceiling design, which can be interpreted to be closely related to the concept of minimalism with expression of simple horizontal and vertical lines, exclusive use of decorative forms, colors and materials, and use of natural materials

An Improvement of Welding Method for the Corrugated Stainless Steel Tubing(CSST) (가스용 금속 플렉시블 호스의 용접방법 개선에 관한 연구)

  • Kim, Wan-Jin;Yi, Yeong-Seop;Choi, Jin-Lim
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.79-83
    • /
    • 2008
  • The corrugated stainless steel tubing(CSST) for the fuel gas piping system can be installed easily and quickly. It is often constructed under the ceiling and the wall which has a good flexibility and installation in comparison with iron pipe. However, the quality of the CSST is determined to depend upon the welding skill of stainless steel tubing. In this study, it is tested by controlling jet point of Ar as inert and cooling gas, and also compared with the bead state of welding point and the performance. As a result, it has the best condition when the jet point of Ar is located behind $5{\sim}10mm$ of the welding point.

Flexion and Extension of Cervical Spine (목뼈의 굽힘과 폄)

  • Shin, Seong-Yoon;Lee, Hyun-Chang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.121-122
    • /
    • 2017
  • In this paper, the angles of flexion of bending the neck to touch the chest and extension of lifting the neck backwards to take the posture of looking up at the ceiling are measured. The basic angle of flexion is in the range of $45{\sim}50^{\circ}$ while the maximum range of angle of movement of flexion is $80{\sim}90^{\circ}$. Similarly, the basic angle of extension is in the range of $40^{\circ}{\sim}50^{\circ}$ and the limit of the normal angle of extension is $70^{\circ}$.

  • PDF

Development of Cabin Noise Prediction Program Induced by HVAC System (공조시스템 유기 격실 소음 예측 프로그램 개발)

  • Kim, Byung-Hee;Kwon, Jong-Hyun;Cho, Dae-Seung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.554-558
    • /
    • 2004
  • In this paper, we introduce noise prediction program of HVAC system to assist low-noisy design of ship's cabin. The developed program calculates sound power levels at HVAC components considering primary and secondary noise generated by fan and duct element, duct element noise attenuation, and duct break-in noise based on the authentic empirical method suggested by NEBB and acoustic power balancing method. Sound pressure level at cabin with or without ceiling system is evaluated by the diffuse-field theory considering diffuser and duct break-out sound powers. Moreover, the program provides intuitive pre- and post-processors using modem GUI functions to help efficient modeling and evaluation of cabin and HVAC component noise. To validate the accuracy and convenience of the program, noise prediction for a HVAC system is demonstrated.

  • PDF

An Experimental Study on the Sound Insulation Performance Characteristics due to the Variation of Ceiling Structures - Focused on the Sound-absorbing and Insulation materials - (바닥슬래브 하부 구조의 개선을 통한차음특성 변화에 관한 실험적 연구 - 흡.차음재를 중심으로 -)

  • Kim, Jun-Yup;Ki, No-Gap;Jung, Il-Ho;Jung, Hwan-Wook;Song, Min-Jung;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.506-511
    • /
    • 2000
  • The aim of this study is to suggest a fundamental data to improve the sound insulation performance of floor. To achieve the aim of this study, 8 types of sound-absorbing and sound insulation materials were installed under the slab, and the floor systems were compared to the general floor system which was composed of slab, timber frame, gypsum board and wallpaper.

  • PDF

A Study on the Room Acoustic Characteristics according to the Layout System of Speakers in the School Gymnasium (학교체육관에서 스피커 배치방식에 따른 실내음향특성에 관한 연구)

  • Lee, Ju-Yeob;Kim, Jong-Bin;Park, Hyeon-Ku;Choi, Hyung-Wook;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.462-467
    • /
    • 2000
  • The aim of this study is to provide fundamental data for acoustic design by analyzing the room acoustic characteristics according to the PA system used in the school gymnasium. The measurements were carried out accordance with the ISO 3382. The sources used in this study were four types; omni-directional, centralized, distribution, the combination of centralized and distribution sound source system. Omni-directional system is recommended by ISO for the acoustic test and the others are installed on the wall, column and ceiling in the school gymnasium for sound reinforcement.

  • PDF

Sound Absorption Characteristics of Building Interior Decoration Materials (건축내장재의 흡음 특성)

  • Kang, Dae-Joon;Lee, J.W.;Gu, J.H.;Park, H.K.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.3 s.120
    • /
    • pp.201-206
    • /
    • 2007
  • It is important to consider the sound absorption characteristics of building interior decoration materials when we design a building and simulate acoustics in a room. The purpose of this study is to accumulate acoustic data on building interior decoration materials and give a basic data for improving the sound absorption performance by testing the sound absorption coefficients of 9 types of ceiling materials, 14 types of wall papers and 20 types of floor papers.

Control and Calibration for Robot Navigation based on Light's Panel Landmark (천장 전등패널 기반 로봇의 주행오차 보정과 제어)

  • Jin, Tae-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.20 no.2
    • /
    • pp.89-95
    • /
    • 2017
  • In this paper, we suggest the method for a mobile robot to move safely from an initial position to a goal position in the wide environment like a building. There is a problem using odometry encoder sensor to estimate the position of a mobile robot in the wide environment like a building. Because of the phenomenon of wheel's slipping, a encoder sensor has the accumulated error of a sensor measurement as time. Therefore the error must be compensated with using other sensor. A vision sensor is used to compensate the position of a mobile robot as using the regularly attached light's panel on a building's ceiling. The method to create global path planning for a mobile robot model a building's map as a graph data type. Consequently, we can apply floyd's shortest path algorithm to find the path planning. The effectiveness of the method is verified through simulations and experiments.

The tracking of a smoke front under a ceiling by a laser sheet and thermocouples (Laser와 열전대를 이용한 연기선단의 위치 추적 비교에 관한 연구)

  • 김명배;한용식;윤명오;김진곤
    • Fire Science and Engineering
    • /
    • v.12 no.3
    • /
    • pp.11-20
    • /
    • 1998
  • A new experimental technique using a laser sheet and thermocouples is introduced to evaluate an intuitive criterion for tracking of a smoke front using thermocouples. From synchronized photos of the smoke front along with temperature signals, the intuitive criterion is shown to be acceptable. Smoke visualization by a laser sheet proves to have several advantages over the conventional techniques such as the use of smoke generators.

  • PDF