• Title/Summary/Keyword: ceiling

Search Result 983, Processing Time 0.026 seconds

Daylight Assessment of Venetian Blind by Shading Heights and Slat Angles (베네시안 블라인드의 높이와 슬랫각도 조절에 따른 계절별 실내주광분포 분석)

  • Shin, Hwa-Young;Kim, Gon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.11 no.2
    • /
    • pp.105-111
    • /
    • 2011
  • Aims of this study is to investigate the daylighting control strategy of venetian blind system was performed as a function of ratio of shading height to window and slat angles in the preliminary stage of the parametric study. Floor-to-ceiling window walls of living spaces are used widely in apartment buildings since the Korean government has legally allowed elimination of the balcony area. Enlarging living area by balcony elimination, the larger glass area of window is exposed to the direct sunlight. As a common sunlight controlling device, blind system can be used in all orientations and all latitudes and it may obstruct, absorb, reflect and transmit solar radiation to building by proper adjusting. However, blind system can produce discomfort in occupant and less energy efficiency, if it has not been controlled optimally. The simulation model was based on the unit module of typical living space with balcony elimination. The room dimension was $6.0m(w){\times}6.9m(d){\times}2.7m(h)$ with floor to ceiling height of 2.5m. The blind system was simulated at five slat angles (horizontal, $30^{\circ}$, $45^{\circ}$ upward and downward tilted) and the four ratio of shading height to window (fully closed, partly opened, no-blind) using the Desktop RADIANCE 2.0 program. The series of simulation results indicates that the advantages of available daylight and outside of view can be improved by proper adjusting blind system.

Plan Composition Expressed in the Architecture of Art Gallery Designed by Louis I. Kahn - Focus on the Yale University Art Gallery Extension - (Louis I. Kahn의 미술관 건축에 나타난 평면구성에 관한 연구 - Yale University Art Gallery Extension을 중심으로 -)

  • Kim, Hong-Bae
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.3
    • /
    • pp.128-135
    • /
    • 2012
  • The purpose of this study is to investigate and analyze the compositional elements of plan of art museums by selecting architectural works, which have strong symbolic meaning when evaluating value, from architectural works by Louis Kahn. First, the centrality of artworks, which are being displayed at the Yale Art Gallery, is complex. It includes three patterns of Void (spatial) Centrality+Symbolic Centrality+Functional Centrality among the five patterns suggested in this study. Second, the ratio system of interior space, which is expressed in the extension of the Yale Art Gallery, can be classified into the floor and walls. The floor used the square 1:1 ratio system. The ceiling used the grid patterns of equilateral triangles (regular tetrahedrons). It was applying a geometric ratio system when creating forms by using one side as a beam and the other sides as decorations of the ceiling. Third, the contours of interior space, which were expressed in Kahn's works, used the method of forming separate space according to the contouring rule (structural unit) defined by columns, and they were used in constructing the entire space through the integration of separate spaces. Fourth, according to the characteristics that were expressed by artworks displayed within the Yale Art Gallery Extension, the concept of accessibility was not as clear as that of residential buildings, because an approach of respecting existing architecture and context was used, rather than the starting point of interior space, or differentiated circulation, which has the function of a determined position.

  • PDF

Wide Coverage Microphone System for Lecture Using Ceiling-Mounted Array Structure (천정형 배열 마이크를 이용한 강의용 광역 마이크 시스템)

  • Oh, Woojin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.4
    • /
    • pp.624-633
    • /
    • 2018
  • While the multimedia lecture system has been getting smart using immerging technology, the microphone still relies on the classical approach such as holding in hand or attaching on the body. In this paper, we propose a ceiling mounted array microphone system that allows a wide reception coverage and instructors to move freely without attaching microphone. The proposed system adopts cell and handover of mobile communication instead of a complicated beamforming method and implements a wide range microphone over several cells with low cost. Since the characteristics of unvoiced speech is similar to Pseudo Noise it is shown that soft handover are possible with 3 microphones connected to delay-sum multipath receiver. The proposed system is tested in $6.3{\times}1.5m$ area. For real-time processing the correlation range can be reduced by 82% or more, and the output latency delay can be improved by using the delay adaptive filter.

Integrated Concurrency Control Protocol for Hard and Soft Real-Time Transactions (하드와 소프트 실시간 트랜잭션을 위한 통합된 동시성제어 기법)

  • Hong, Seok-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.2
    • /
    • pp.57-66
    • /
    • 2008
  • Most concurrency control protocols have been devised for resolving data conflicts among real-time transactions of a single type. Recent real-time database systems should support various types of real-time transactions due to needs of many different types of applications and steady improvement of hardware. In this paper, we propose integrated concurrency control protocol to resolve data conflicts among hard and soft real-time transactions. Our proposed protocol, based on PCP(Priority Ceiling Protocol) for a hard real-time transactions and MVPR(Multiversion with Precedence Relationship), guarantees that hard real-time transactions meet their deadline, and decreases the deadline miss ratio of soft real-time transactions. We also proved that the proposed protocol guarantees serializable schedules and no deadlocks. The performance of the proposed protocol has been compared with other real-time concurrency protocols.

Analysis of Indoor Air & thermal environment with Hybrid Ventilation system during summer (하계 공동주택 하이브리드 환기시스템 적용에 따른 실내공기 및 열 환경 평가)

  • Kim, Sang-Jin;Kim, Eun-Soo;Kim, Tae-Yeon;Leigh, Seung-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.387-392
    • /
    • 2006
  • The recent on indoor air problem has led to many studies on the methods and effects of ventilation for better indoor air quality. Although natural ventilation is the most effective and energy-saving method in residental housings, the small size of openable window has been a problem in high-rise residential buildings to ventilate only through natural ventilation. Consequently, the installation of mechanical ventilation system has been a requirement in residential buildings, and has caused other problems such as increase of energy consumption and SBS. Hybrid ventilation which uses forces of both natural and mechanical power has been introduced to solve the problem of increase in energy consumption with natural ventilation. In this paper, two types of hybrid ventilation systems in residential building were introduced. One type was with natural ventilation through vent grille in the window, and another type was with natural ventilation through ceiling duct while both types used mechanical ventilation system with the outlets. The indoor temperature distribution and pollution density distribution in summer while operating the ceiling air conditioner were analyzed through CFD simulation. In this paper, the optimal location of diffusers to achieve thermal comfort would be proposed.

  • PDF

Analysis of Design Elements and Barriers to Link the Emission Trading Systems between the Republic of Korea and China (한·중 배출권거래제 연계를 위한 설계요소 및 장애요인 분석)

  • Park, Su Gyeong;Park, Soon chul;Song, Cholho;Lim, Chul-Hee;Lee, Soo Jeong;Lee, Woo-Kyun
    • Journal of Climate Change Research
    • /
    • v.9 no.4
    • /
    • pp.471-485
    • /
    • 2018
  • The Republic of Korea (ROK) has made many efforts to reduce greenhouse gases through a legal framework, making obligations to reach domestic and overseas targets via the Paris Convention in 2015. China recently launched a nation-wide emission trading system (ETS) and has considered extending this ETS to include the ROK. This study examines the possibility of linking the ETS between ROK and China by considering the institutional design elements of the ETS. Additionally, this study provides policy implications to reach Korea's overseas reduction target. For the research methodology, the design elements of both the ROK and China policies were analyzed by categorizing their standard design elements based on the International Carbon Action Partnership. This paper focuses on four main barriers (cap type, borrowing, offset and price ceiling) based on their environmental benefits and analyzes the challenges to combining the design elements between the ROK and China systems. The two ETS commonly share the same cap types, and there is similar institutional progress regarding the offset and price ceiling. In addition to this, note that China has a borrowing system that is opposite to the borrowing system in ROK. According to these findings, there are major challenges to linking the ROK and China systems due to differences in the major design elements. Thus, it is necessary to modify the Korean domestic borrowing system and understand the Chinese institutional processes related to environmental negotiation to achieve further cooperation.

Mechanical evolution law and deformation characteristics of preliminary lining about newly-built subway tunnel closely undercrossing the existing station: A case study

  • Huijian Zhang;Gongning Liu;Weixiong Liu;Shuai Zhang;Zekun Chen
    • Geomechanics and Engineering
    • /
    • v.35 no.5
    • /
    • pp.525-538
    • /
    • 2023
  • The development of a city is closely linked to the construction and operation of its subway system. However, constructing a new subway tunnel under an existing station is an extremely complex task, and the deformation characteristics and mechanical behavior of the new subway tunnel during the excavation process can greatly impact the normal operation of the existing station. Although the previous studies about the case of underpass engineering have been carried out, there is limited research on the condition of a newly-built subway tunnel that closely undercrossing an existing station with zero distance between them. Therefore, this study analyzes the deformation law and mechanical behavior characteristics of the preliminary lining of the underpass tunnel during the excavation process based on the real engineering case of Chengdu Metro Line 8. This study also makes an in-depth comparison of the influence of different excavation methods on this issue. Finally, the accuracy of numerical simulation is verified by comparing it with on-site result. The results indicate that the maximum bending moment mainly occurs at the floor slab of the preliminary lining, while that of the ceiling is small. The stress state at the ceiling position is less affected by the construction process of the pilot tunnel. Compared to the all-in-one excavation method, although the process of partial excavation method is more complicated, the deformation of preliminary lining caused by it is basically less than the upper limit value of the standard, while that of the all-in-one excavation method is beyond standard requirements.

Real-time Analysis and Safety Assessment of Volatile Organic Compounds Emitted from Masks (마스크에서 방출되는 휘발성유기화합물의 실시간 분석 사례)

  • Hyekyung Seo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.3
    • /
    • pp.179-188
    • /
    • 2024
  • Objectives: The safety of distributed masks has been widely investigated following the coronavirus disease (COVID-19) pandemic. Although the unpleasant odor from masks is concerning, research on the toxicity of volatile organic compounds emitted from them is limited. Here, we aimed to quantify the VOCs emitted from masks and explore strategies for safe mask usage. Methods: The VOCs emitted from 15 masks in five categories were measured. Proton transfer reaction time-of-flight mass spectrometry (PTR-TOF-MS, IONICON, Austria), which can rapidly and sensitively detect complex mixtures, was conducted. The test chamber connected to the equipment was comprised of uninterrupted acrylic and glass. PTR-TOF-MS data were analyzed using Tofware (PTR-MS Viewer 3.3, IONICON, Austria). Statistical analyses were performed using SPSS ver. 20 to determine the highest, lowest, and average concentrations of the VOCs (IBM SPSS Inc., USA). Analysis of variance (ANOVA) was conducted to compare the VOCs emitted from different masks. Results: A total of 25 VOCs were detected among the 15 masks. The peak concentrations of formaldehyde, acrolein, isoprene, and benzene were higher than the exposure standards (Ceiling). The average concentrations of these compounds differed significantly among the mask samples (p < 0.05). The VOC concentration decreased gradually after approximately one hour. Conclusions: Higher concentrations of VOCs were emitted from healthy, printed, and surgical masks compared to industrial masks. Further research is required to determine the factors affecting VOCs, such as mask material, temperature, and humidity. For safety, masks must be ventilated for at least an hour before usage.

A Study on the Structural Characteristics and Estimation of Refrigerating. Load for the Fruit Storage (청과물저장고의 구조특성 및 냉각부하량 산정에 관한 연구)

  • 이석건;고재군
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.18 no.1
    • /
    • pp.4038-4051
    • /
    • 1976
  • This study was intended to provide the basic design creteria for the refrigerated storage, and to estimate the required optimum capacity of refrigerator for the different sizes and kinds of the existing fruit storage. The structural characteristics of the existing fruit storages in Pyungtaek-khun of Kyungki-do were surveyed. The average out-door air temperature during the expected storage life after harvesting, was obtained by analyzing the weather information. The heat transfer rates through the different models of storage walls were estimated. The refrigerating load required for different models of fruit storage was analyzed in the basis of out-door air temperature. The results obtained in this study are summarized as follows: 1. The fruit storages surveyed were constructed on-ground, under-ground and sub-ground type buildings. The majority of them being the on-ground buildings are mostly made of earth bricks with double walls. Rice hull was mostly used as the insulating materials for their walls and ceilings. About 42% of the buildings were with the horizontal ceiling, 22% with sloped ceiling, and about 36% without ceiling. About 60% of the storage buildings had floor without using insulated material. They were made of compacted earth. 2. There is no difference in heat transfer among six different types of double walls. The double wall, however, gives much less heat transfer than the single wall. Therefore, the double wall is recommended as the walls of the fruit storage on the point of heat transfer. Especially, in case of the single wall using concrete, the heat transfer is about five time of the double walls. It is evident that concrete is not proper wall material for the fruit storage without using special insulating material. 3. The heat transfer through the storage walls is in inverse proportion to the thickness of rice hull which is mostly used as the insulating material in the surveyed area. It is recommended that the thickness of rice hull used as the insulating material far storage wall is about 20cm in consideration of the decreasing rate of heat transfer and the available storage area. 4. The design refrigerating load for the on-ground storages having 20 pyung area is estimated in 4.07 to 4.16 ton refrigeration for double walls, and 5.23 to 6.97 ton refrigeration for single walls. During the long storage life, however, the average daily refrigerating load is ranged from 0.93 to 0.95 ton refrigeration for double walls, and from 1.15 to 1.47 ton refrigeration for single walls, respectively. 5. In case of single walls, 50.8 to 61.4 percent to total refrigerating load during the long storage life is caused by the heat transferred into the room space through walls, ceiling and floor. On the other hand, 39.1 to 40.7 percent is for the double walls. 6. The design and average daily refrigerating load increases in linear proportion to the size of storage area. As the size increases, the increasing rate of the refrigerating load is raised in proportion to the heat transfer rate of the wall. 7. The refrigerating load during the long storage life has close relationship to the out-door air temperature. The maximum refrigeration load is shown in later May, which is amounted to about 50 percent to the design refrigerating load. 8. It is noted that when the wall material having high heat transfer rate, such as the single wall made of concrete, is used, heating facilities are required for the period of later December to early February.

  • PDF

A Study on the Presence of Murals by Scientific Investigation on the Inner Walls of West Ancient Tomb No.1 and 2 Neungsan-ri, Buyeo (부여 능산리 서고분군 1·2호분 내벽의 과학적 조사를 통한 벽화 존재 유무 연구)

  • Lee, Hanhyoung;Kim, Dongwon;Lee, Hwasoo
    • Conservation Science in Museum
    • /
    • v.22
    • /
    • pp.41-52
    • /
    • 2019
  • Inner walls of the stone chamber of West Ancient Tomb No. 1 and 2 in Neungsan-ri, Buyeo-gun have been inspected for possible trace of murals. Tomb No.1 has a rough surface finish of the stone wall and no traces of murals was observed in any part of the stone walls except the ceiling part of the main chamber. On the ceiling surface, there is black colored area, which showed same visual characteristics for both the surface and interior upon slight scratch of the surface, suggesting that it may not be a painted layer. In addition, this black material is not artificial stuff like black ink but is confirmed as biotite from X-ray diffraction analysis that is one of the constituents of the stone wall. In case of tomb No. 2, white material, that is confirmed as lime(calcite, CaCO3) by X-ray diffraction analysis, was observed on the wall surface of the east, west and north, suggesting possible existence of murals. The lime layers, however, are located mostly on the entrance of east wall of main chamber and the place of passage whereas they are observed only in lower parts on the other walls. It may have been formed by the inflow of soil and lime from the outside as the form of the lime layer in the east wall corresponds to the traces of soil and lime deposited from the thief pit. Furthermore, the filling material found in the gap between the stone slabs of the four directions and the ceiling was confirmed as clay soil, which is different material from the lime present on the stone wall surface. If the lime layer had been artificially constructed for the purpose of creating murals, it would have been more reasonable to use lime as well in the gap between the stone slabs of the four directions and ceiling. In this regard, we conclude that there are no murals in the Tomb No. 2 in the Neungsan-ri.