• Title/Summary/Keyword: ceiling

Search Result 983, Processing Time 0.031 seconds

Effects of the benefit extension policy on the burdening of health care expenditure for households with patients of chronic or serious case (보장성 강화정책이 만성질환자 및 중증질환자 보유가구의 과부담 의료비 발생에 미친 영향)

  • Choi, Jung-Kyu;Jeong, Hyoung-Sun;Shin, Jeong-Woo;Yeo, Ji-Young
    • Health Policy and Management
    • /
    • v.21 no.2
    • /
    • pp.159-178
    • /
    • 2011
  • Korea ranks high among the OECD member countries with a high out-of-pocket share. In 2006, the government implemented in full scale the policy of extending the health insurance benefit coverage. Included in the policy are lowering the out-of-pocket share of patients of serious case and expanding the medical bill ceiling system to mention just a few. This study proposes to confirm effectiveness of the benefit extension policy by identifying changes in 'out-of-pocket expenditure as a share of the ability to pay' and 'incidence rate of catastrophic health care expenditure' of each individual household as manifested before and after the benefit extension policy was implemented. The 1st and 3rd year data from the Korea Welfare Panel Study (KoWePS), conducted by the Korea Institute for Health and Social Affairs (KIHASA), were used for the analysis, where low-income households and ordinary households are sampled separately. While the absolute amount of 'out-of-pocket expenditure' occurred to the average household increased for the period 2005-2007, the 'out-of-pocket expenditure as a share of the ability to pay' decreased. At the same time, the share decreased in the case of low-income households and households with patients of chronic or serious case as contrasted with ordinary households. 'Incidence rates of catastrophic health care expenditure' of ordinary households for 2007 stood at 14.6%, 5.9% and 2.8% at the threshold of 10%, 20% and 30%, respectively. The rates decreased overall between 2005 and 2007, while those of low-income households with patients of serious case statistically significantly increased. An analysis of this study indicates that it is related with the medical bill ceiling system regardless of incomes introduced in 2007.

Analysis of the Causes of Casualties of Jecheon Sports Center Fire - Focus on an Initial Response and Management - (제천 스포츠센터 화재의 다수 사상자 발생원인 분석 -초기대응과 관리적인 측면을 중심으로-)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.57-66
    • /
    • 2018
  • A sports center fire in Jecheon that caused 29 deaths and 40 injuries was analyzed based on initial response and management in order to investigate the causes of the casualties. The aspects of initial response included delay of reporting 119, not being guided to the exit for the body scrubber on the $2^{nd}$ floor for escape, opening the fire doors of the exits on the $1^{st}$ floor and $3^{rd}$ floor, not closing the fire door of the main stairs on the $3^{rd}$ floor, and not doing an emergency broadcast. The management aspects included closing the alarm valve of the sprinkler system on the $1^{st}$ floor, starting-stop of the fire pump controller, neglecting leakage of water and electricity between the false ceiling and ceiling in the parking lot, hiding the exit light in the ladies bathroom lounge on the $2^{nd}$ floor and piling up things in the exit, neglecting the button of an automatic door on the $2^{nd}$ floor, conventional fire safety management, insufficient inspection of fire equipment, and not working fire shutters and smoke exhaust windows.

Glass ceiling in video games: Unequal gender status in Pokémon Series (게임에서의 유리천장: 포켓몬 시리즈의 불평등 성 지위)

  • Han, Sukhee
    • Journal of Korea Game Society
    • /
    • v.17 no.6
    • /
    • pp.173-188
    • /
    • 2017
  • This study explores the gender status of $Pok{\acute{e}}mon$ Series by analyzing the aspects of male/male-dominated $Pok{\acute{e}}mons$ and female/female-dominated $Pok{\acute{e}}mons$. Counting from the First Generation to the Seventh Generation $Pok{\acute{e}}mon$, there are 802 characters. Each $Pok{\acute{e}}mon$ has different gender ratio; the one $Pok{\acute{e}}mon$ could have more "possibility" to become male, female, equal, or genderless when he/she is born. This study examines those $Pok{\acute{e}}mons$ in three criteria: 1) Frequency 2) Stats 3) Diversification of Type, and it compares them based on their gender. $Pok{\acute{e}}mon$ Series is different than other video games as it provides many characters ($Pok{\acute{e}}mons$). Thus, it helps the audience to view the gender status of video game characters more closely and meaningfully.

Subjective Evaluation of Loudspeaker Layouts for a Large Dome (대공간 스피커 배치 방식의 주관적 평가 연구)

  • Jeong, Dae-Up;Choi, Young-Ji;Kim, Jeong-Su
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.3
    • /
    • pp.75-80
    • /
    • 2010
  • The present study tried to provide useful data for the acoustic design of sound amplification system with measuring and analyzing subjective preference and intelligibility by varying the number of speakers and their directivity. The results suggest that the room absorption plays a key role in subjective responses of listeners and the large sound absorption of ceiling contributes to the increase of intelligibility. Also, larger number of speakers with narrow directivity improves perceived intelligibility when speakers were installed at the lower height. However, the highest degree of intelligibility and preference were obtained when speakers were installed close enough to the sound absorptive ceiling. The highest intelligibility and preference were observed when 8 to 10 speakers with the directivity of 60 degree were used.

  • PDF

Analysis of Peak Wind Pressure Coefficients of Penetration Type and End Type Pilotis (관통형과 단부형 필로티 천장부의 피크풍압계수 특성 분석)

  • You, Jang-Youl;Kim, Geun-Ho;Chae, Myung-Jin;Kim, Young-Moon;You, Ki-Pyo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.2
    • /
    • pp.59-67
    • /
    • 2018
  • Various pilotis are installed in the lower part of high rise buildings. Strong winds can generate sudden airflow around the pilotis, which can cause unexpected internal airflow changes and may cause damage to the exterior of the piloti ceiling. The present study investigates the characteristics of peak wind pressure coefficient for the design of piloti ceiling exteriors by conducting wind pressure tests on high rise buildings equipped with penetration-type and end-type pilotis in urban and suburban areas. The minimum peak wind pressure coefficient for penetration-type piloti ceilings ranges from -2.0 to -3.3. Minimum peak wind pressure coefficient in urban areas was 30% larger than in suburban areas. In end-type piloti ceilings, maximum peak wind-pressure coefficient ranges from 0.5 to 1.9, and minimum peak wind-pressure coefficient ranges from -1.3 to -3.6. With changes in building height, peak wind pressure coefficient decreases as the aspect ratio increases. Peak wind-pressure coefficient increases with taller pilotis. On the other hand, when piloti height decreases, the absolute value of the minimum peak wind pressure coefficient increases.

The Relationship Between Activities of Daily Living and Health-Related Quality of Life in Ambulatory Stroke Patients (보행 가능한 뇌졸중 환자의 일상생활 수행능력과 건강관련 삶의 질과의 관계)

  • Won, Jong-Im
    • Physical Therapy Korea
    • /
    • v.15 no.1
    • /
    • pp.12-19
    • /
    • 2008
  • The purpose of this study was to determine the relationship between activities of daily living and health-related quality of life in ambulatory stroke patients. This was a cross-sectional survey study of 60 patients who had survived one year or more after a stroke in community. Activities of daily living were assessed using the Functional Independence Measure (FlM) and health-related quality of life using the Stroke Impact Scale (SIS). The association between FIM and SIS was examined using Pearson' s correlation. The FIM score was higher than the SIS score. Most domains of FIM exhibited a high rate (45-85%) of ceiling effects. However, only the communication and memory domain of SIS exhibited of ceiling effects. The correlation coefficients were .835 (p<.01) for FIM-motor vs. SIS-ADL, .257 (p<,05) for FIM-motor vs. SIS-communication, .596 (p<.01) for FIM-motor vs. SIS-social participation, .635 (p<.01) for FIM-cognition vs. SIS-memory, .369 (p<.01) for FIM-cognition vs. SIS-ADL, and .289 (p<.05) for FlM-cognition vs. SIS-social participation. In conclusion, the correlation between FIM-motor and SIS-social participation was higher than that of FlM-cognition and SIS-social participation. The domains of emotion and hand function of SIS showed no correlation coefficients with FIM-total. To examine the activities of daily living and the quality of life in ambulatory stroke patients in community, it is necessary to use both the FIM and SIS.

  • PDF

Effects of Daylight and Solar Radiation on Indoor Thermal Environment According to Space Structures in Multi-Complex Cultural Center (복합문화시설내 공간 구조에 따른 일조와 일사가 실내 온열환경에 미치는 영향)

  • Choi, Byungbo;Jeon, Hyun Sik;Yoon, Seokil;Kim, Sughwan;Lee, Sang-Jin;Kim, Sumin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.11
    • /
    • pp.751-758
    • /
    • 2012
  • Recently, people are paying attention to new forms of construction. For example, deviated from an enclosed type space, people have been interested in an atrium type and an arcade type spaces. In this study, we had hypothesis 'Indoor thermal environment will be influenced by the inflow rate of natural lights with temperature and humidity.' We selected a multi-complex cultural center and conducted this study. This place is consisted of atrium, arcade, and enclosed types. The three spaces were classified according to the type of spaces that have own features along with their forms. The atrium type space has ceiling and the side windows, and the arcade type space has ceiling windows. On the other hand, there are no windows or open parts in the enclosed type space. Three measurement points at each space were selected because of their huge space. Intensity of illumination, temperature and humidity were confirmed by the average value of three measurement points. In addition, surveys were conducted regarding indoor comfort elements in each space.

Simulation Study on the Performance Evaluation of Light-shelf According to Geometric Shape of Ceiling (천장의 기하학적 형태에 따른 광선반 성능평가 시뮬레이션 연구)

  • Lee, Henagwoo;Kim, Yongseong;Seo, Janghoo;Kim, Duk-Su
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.4
    • /
    • pp.181-192
    • /
    • 2014
  • Light-shelf is one of the most efficient natural lighting systems due to the improved function of the inflow level of the outdoor natural light. However, the existing research on the light shelf limits to the rectangular parallelepiped space, so do not provide sufficient data for various shapes of spaces. Thus, this study aims at deriving proper plan and relationship of the light shelf through its performance assessment depending on the indoor space shapes and utilizing them as basic data of light shelf design. The conclusions are as follows : 1) for 6m space depth, standard intensity of illumination satisfaction depth has shown 8.3%~26.3% improvement through the adjustment of the angle and width when installing light shelf compared to no light shelf installation; 2) $-30^{\circ}$, $-20^{\circ}$ and $-10^{\circ}$ light shelves set by this study play only as a blind regardless of the shape of ceiling on the summer solstice, and it is unsuitable; and 3) this study has derived proper plan of light shelf upon space shapes based on energy reduction and indoor evenness. The study results provide expanded data of the performance assessment of the light shelves according to the different space shapes and light shelf factors, which serves as a basis of the light shelves designing.

A Study on the Image-based Automatic Flight Control of Mini Drone (미니드론의 영상기반 자동 비행 제어에 관한 연구)

  • Sun, Eun-Hey;Luat, Tran Huu;Kim, Dongyeon;Kim, Yong-Tae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.6
    • /
    • pp.536-541
    • /
    • 2015
  • In this paper, we propose a the image-based automatic flight control system for the mini drone. Automatic flight system with a camera on the ceiling and markers on the floor and landing position is designed in an indoor environment. Images from the ceiling camera is used not only to recognize the makers and landing position but also to track the drone motion. PC sever identifies the location of the drone and sends control commands to the mini drone. Flight controller of the mini drone is designed using state-machine algorithm, PID control and way-point position control method. From the, The proposed automatic flight control system is verified through the experiments of the mini drone. We see that known makers in environment are recognized and the drone can follows the trajectories with the specific ㄱ, ㄷ and ㅁ shapes. Also, experimental results show that the drone can approach and correctly land on the target positions which are set at different height.

The Planning of Temporary Housing for Post Application of Mega Sports Facilities - Focused on the 2018 Winter Olympics - (메가스포츠시설의 사후 활용을 위한 임시주거 계획 - 2018평창동계올림픽을 중심으로 -)

  • Lee, Jong-Chan;Kang, Youn-Do;Kim, Byung-Sean
    • KIEAE Journal
    • /
    • v.16 no.4
    • /
    • pp.41-46
    • /
    • 2016
  • Purpose: This is a study on the planning of temporary housing for post application of Mega Sports facilities. The subject of the study is 2018 Pyeongchang Winter Olympics, which is to suggest building an alternative temporary housing using shipping containers(high cube), which solve the lack of accommodations and recycle temporary housing after Olympics, save money and be eco-friendly in Olympics. Method: This study includes this ; research on the a fact-finding survey about Mega sports facilities post application and demand survey on 2018 Pyeongchang Winter Olympics accomodations and an analysis about temporary housing plan. Furthermore we decided temporary housing building plan by analyzing residents' needs and traits of the housing etc. Through this, we made a schematic design for household units. Result: As a result, this study is a plan of making space, forms, and structure. The planned size is $38.4m^2$(L:12m, W:3.2m) except balcony, and indoor height is 2.5m. The space consists of entrance, bathroom, bedroom and living room with folding furniture system. Also there's a detailed floor plan of the ceiling, wall, and floor we drew up. The ceiling and wall consist of dampproof film, noncombustible board, fire proof urethane form, and color-designed sheet. The floor is composed of floor tile, cement mortar, light concrete(with heat coil), insulation, and dampproof film. Additionally, this study is a plan of interior dry wall with detail using modular construction method for work efficiency and quality improvement.