• Title/Summary/Keyword: ceiling

Search Result 983, Processing Time 0.032 seconds

Morphological Measurements of Anatomic Landmarks in Human Mandibular Molar Pulp Chambers - An in vivo Study

  • Lokade, Joyti;Rawlani, Shivlal;Baheti, Rakhi (Chandak);Roy, Shelly;Chandak, Manoj;Lohe, Vidya
    • Journal of Korean Dental Science
    • /
    • v.4 no.1
    • /
    • pp.1-5
    • /
    • 2011
  • Purpose: Exact knowledge of the location and dimension of the pulp chamber help to maintain the pulp healthy during operative procedure and also reduces the risk of perforation of pulp chamber during root canal treatment. This in-vivo study was carried out to measure critical morphology of pulp chamber of mandibular molar using intra-oral periapical radiograph. Materials and Methods: Mandibular molar teeth of 56 patients were evaluated. The mandibular molar teeth whose pulp chamber was not violated by caries, restoration, fracture crown and those having closed apex were included in the study. The intraoral periapical radiographs were taken with paralleling angle technique using radio-opaque grid with 1 mm space. This grid was placed directly on the film. Results: In 94% of the mandibular first molars specimens the pulp chamber ceiling was at the level of the cemento-enamel junction. The measurements showing the lowest percentage variance were buccal cusp to furcation (approximately 11%) and buccal cusp to pulp chamber ceiling (approximately 15%). The distance from the cusp tip to pulp chamber ceiling height was approximately 6.0 mm, the distance from the pulpal floor to the furcation was approximately 3.0 mm, and the average height of a pulp chamber was 1.5 to 2.0 mm. Conclusion: The exact knowledge of distances of pulp chamber from various anatomical landmarks helps in proper assessment of root canals and ultimately avoids the failure of root canal treatment.

A Study on Experimental Characteristics in Fire Investigation Techniques of Flammable Liquids (유류화재의 감식기법의 실험적 특성에 관한 연구)

  • Hwang, Taeyeon;Choi, Donmook
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.7-14
    • /
    • 2012
  • This paper is to develop analytical techniques of flammable liquids which have been used for accelerating fire in accidental fires and arsons. We tested the temperature distribution of ceiling, fire patterns on the floor, and existence of flammable liquids and a check with GC/MS about flammable liquids comparing with papers, newspapers, and clothing. Research findings are as follows. The temperature of ceiling is influenced by flame. So gasoline and thinner was observed that combustible materials would be burned by flame. The fire patten on the floor was observed that flammable liquids had specialized pattern comparing combustible materials. When combustible materials on the PVC (Polyvinyl chloride) floor was burned, they didn't react to the gas detector. But flammable liquids had opposite results. After 7 days, we identified components of fire residues with the GC/MS (Gas Chromatography/Mass Spectrometry) about existence of flammable liquids and got components of flammable liquids. Fire investigation is a complicated processes. But we understand characteristics of materials, need detail investigations, and use the GC/MS to analyse flammable materials.

A Study on the Flame Pattern and the Electrical Properties of Electric Outlet Fired at Standby Mode (Standby Mode에서 출화된 콘센트의 화염 패턴 및 전기적 특성에 관한 연구)

  • 최충석;송길목;김형래;김향곤;김동욱;김동우
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.39-44
    • /
    • 2002
  • In this paper, we analysed the flame patterns and the electrical characteristics of the electric outlet which was fired at standby mode. The carbonized patterns indicated that the flame had spread about 50 cm to 70 cm. After the combustibles on wall started to burn, the temperature went up to about $300^{\circ}c$ in 150 sec. The flame formed ceiling jet and spread quickly. The tracking was generated at the shortest distance between two electrodes and the resistance was about 100$\Omega$ to 300$\Omega$ As the result of analysis using metallurgical microscope, the normal part of a blade holder showed amorphous structure, but the melted part of a blade holder damaged by tracking showed dendrite structure and void evenly. When the blade holder of damaged outlet was analyzed by SEM and EDX, we found that the structure and components of the normal part were different from those of melted part.

Asbestos Content in Friable Sprayed-on Surface Material and Airborne Fiber Concentrations in Commercial Buildings (대형건물내 비고형 석면함유 건축자재에 의한 기중 석면오염 및 관리실태)

  • Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.137-146
    • /
    • 1995
  • Twenty(20) large commercial buildings located in Seoul with friable sprayed-on surface insulation material on ceilings were investigated for asbestos content in bulk material by polarized light microscopy and for airborne fiber concentrations in buildings by phase contrast microscopy. In addition, such building-related variables as building age, numbers of traffic, airflow, surface conditions of the ceiling, temperature, and humidity were studied for any correlation with airborne fiber concentrations. The results were as follows: 1. Chrysotile asbestos was found in two bulk samples with 3-5% content and with <1%in one sample out of total 20 bulk samples collected. Glass fiber and mineral wool were the two major constituents of the bulk samples. 2. The ceiling surfaces were very friable in 16 buildings and were relatively hard in 4 buildings. The friability of the surface material was dependent upon the type and the amount of binder that had been mixed with the sprayed-on surface material. 3. Airborne fiber concentrations were log-normally distributed and the geometric mean(geometric standard deviation) fiber concentrations in the underground parking lots, inside buildings, and outdoor ambient air were 0.0063(1.97)f/cc, 0.0068(2.29)f/cc, and 0.0033(2.36)f/cc, respectively. 4. No significant relationship of airborne fiber concentrations and all building-related variables studied except humidity was found. The results of this study suggest that the sprayed-on surface insulation material found in some commercial buildings may possibly be contaminated with asbestos. Since most of the ceiling surfaces surveyed were very friable and poorly maintained and the airborne fiber concentrations were relatively high, there is a possibility of asbestos fiber contamination in these buildings, particularly at those buildings with asbestos-contaminated surface material. Since poorly maintained surface conditions were thought to be a source of high airborne fiber concentrations, there is a urgent need of a systematic operation and maintenance program. Further study of non-occupational asbestos exposure in general population utilizing advanced analytical technique such as transmission electron microscopy is highly recommended.

  • PDF

A Numerical Study of Smoke Movement in Atrium Fires with Ceiling Hea Flux (천장에 열 유속을 갖는 대형 공간에서 화재 발생시 연기거동에 대한 수치해석적 연구)

  • 정진용;유홍선;김성찬;김충익
    • Fire Science and Engineering
    • /
    • v.13 no.4
    • /
    • pp.20-29
    • /
    • 1999
  • This paper describes the smoke filling process of a fire field model based on a self-developed SMEP(Smoke Movement Estimating Program) code to the simulation of fire induced flows in the two types of atrium space containing a ceiling heat flux. The SMEP using PISO algorithm solves conservation equations for mass, momentum, energy and species, together with those for the modified k- epsilon turbulence model with buoyancy term. Compressibility is assumed and the perfect gas law is used. The results of the calculated upper-layer average temperature and smoke layer interface height has shown reasonable agreement compared with the zone models. The zone models used are the CFAST developed at the Building and Fire Research Laboratory NIST U.S.A. and the NBTC one-room of FIRECALC developed at CSIRO, Australia. The smoke layer interface heights that are important in fire safety were not as sensitive as the smoke layer temperature to the nature of ceiling heat flux condition.

  • PDF

Research on Durability Assessment of Asbestos Stabilizer for Asbestos-containing Ceiling Materials (석면 함유 천장재에 대한 석면 안정화제 내구성 평가 연구)

  • Ha, Joo-Yeon;Shin, Hyun-Gyoo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.1
    • /
    • pp.18-27
    • /
    • 2020
  • Objectives: For testing asbestos stabilizer products which are used for the maintenance and management of asbestos-containing materials, durability assessment should accompany the evaluation of basic properties and performance. Therefore, in this study we designed a testing method and constructed a database of durability performance, thereby providing basic data for reliability studies of asbestos stabilizer. Methods: Since the ceiling materials targeted in this study are interior materials, test conditions of 95% relative humidity and 60℃ temperature were designed in consideration of the effect of high relative humidity in summer and seasonal indoor temperatures. Plate-shaped specimens treated with asbestos stabilizers were maintained in a thermo-hygrostat for 5, 10, and 20 days, and then the asbestos scattering prevention rate was measured by air erosion testing. Results: The scattering concentration tended to increase with time under the single humidity condition, and exceeded the indoor air quality standard of 0.01 f/cc, during the 20 days of maintenance. On the other hand, there was little change according to the temperature condition. In the case of a complex condition with temperature and humidity, the results were similar to the humidity test, but the scattering concentration increased more sharply at 20 days. Conclusions: The main deterioration factor that affects the durability of asbestos stabilizer is humidity, and the deterioration is caused by a mechanism in which the stabilizer coated on the surface is re-dissolved by moisture and evaporates or the coating layer is peeled off, which is accelerated by high temperatures.

Structural Safety Analysis on Car Body at Overturn (전복시 차체에 대한 구조 안전 해석)

  • Cho, Jae-Ung;Kim, Key-Sun;Lee, Eun-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.32-37
    • /
    • 2011
  • In this study, the changes of displacement and stress are investigated by structural analysis according to the thickness of car body in case of overturn. In case of 5 mm thickness, the maximum displacement of 7.5024 mm at its right ceiling and the maximum equivalent stress of 113.69 MPa at the left lower part are occurred on the elapsed time of 2 second. In case of 10 mm thickness, the maximum displacement of 1.2557 mm at its right ceiling and the maximum equivalent stress of 15.134 MPa at the left lower part are occurred on the elapsed time of 2 second. In case of 15 mm thickness, the maximum displacement of 0.426067 mm at its right ceiling and the maximum equivalent stress of 4.4842 MPa at the left lower part are occurred on the elapsed time of 2 second. As stress and displacement are uniformly distributed according to time in this case, the design of car body can be stabilized.

A Study on the comparison of Infill Technology between Korea long life Apartment Mock up House and Japan KSI experimental House (국내 장수명 공동주택 Mock-up House와 일본 KSI 실험주택 인필 요소기술 비교 연구)

  • Choi, Young Ho;Kim, Shin;Kim, Sung Wan
    • KIEAE Journal
    • /
    • v.8 no.4
    • /
    • pp.63-69
    • /
    • 2008
  • The thesis is a comparative analysis of Infill Technologies between Korea's long-life Mock-up House, a study driven by 'Durability and Flexibility of Long-life Housing Technology Development' of R&D, and Japan's KSI experimental house, the major example of Japan's long-llfe housing. In terms of the domestic Mock-up House, a system of building the floor first was applied. The floor material of each housing unit required a development of dry heating component that is partially substitutable in order to avoid conflict with the finishing. Also, a development of a floor system that can counteract against the construction inaccuracy was required. In the Case of an outer wall, need to make the wall with the chassis. In the case of ceiling, need to develop the double ceiling system which is good for sound insulation. Also, in comparison to KSI experimental house in Japan, it would require to develop a wiring system of the ceiling which can react to the movement of the wall. Especially, to assure the flexible nature of an internal wall, it would desperately require the research and development of the products related to components and flexible system of mechanical/electrical/communication parts as well as supporting institutionalized system for this development. Furthermore, for KSI experimental house in Japan, it would be necessary to formulate a construction manual as well as a systematic and practical planning guide to invent a new interface rule which will secure simplicity of assembling, dismantling, installation and replacement of architectural components for which research development is quite insignificant at the moment. This effort will have to continue to give a solid direction for better application of such reference manual during construction and development of long life span apartment by public sector as well as private corporations.

Electrical Resistivity Imaging for Upper Layer of Shield TBM Tunnel Ceiling (쉴드 TBM터널 상부 지반 연약대 전기탐사)

  • Jung, Hyun-Key;Park, Chul-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.401-408
    • /
    • 2005
  • Recently shield TBM tunnellings are being applied to subway construction in Korean cities. Generally these kinds of tunnellings have the problems in the stability of ground such as subsidence because urban subway is constructed in the shallow depth. A sinkhole occurred on the road just above the tunnel during tunneling in Kwangju, so a survey for upper layer of the tunnel was needed. But conventional Ground Probing Radar can't be applicable due to the presence of steel-mesh screen in the shield segment, so no existent geophysical method is applicable in this site. Because the outer surface of each shield segment is electrically insulated, dipole-dipole resistivity method which is popular in engineering site investigation, was tried to this survey for the first time. Specially manufactured flexible ring-type electrodes were installed into the grouting holes at an interval of 2.4 m on the ceiling. The K-Ohm II system which has been developed by KIGAM and tested successfully in many sites, was used in this site. The system consists of 1000Volt-1Ampere constant-current transmitter, optically isolated 24 bit sigma-delta A/D conversion receiver - maximum 12 channel simultaneous measurements, and graphical automatic acquisition software for easy data quality check in real time. Borehole camera logging with circular white LED lighting was also done to investigate the state of the layer. Measured resistivity data lack of some stations due to failing opening lids of holes, shows general high-low trend well. The dipole-dipole resistivity inversion results discriminate (1) one approximately 4 meter diameter cavity (grouted but incompletely hardened, so low resistivity - less than $30{\Omega}m$), (2) weak zone (100-200${\Omega}m$), and (3) hard zone (high resistivity - more than 1000${\Omega}m$) very well for the distance of 320 meters. The 2-D inversion neglects slight absolute 3-D effect, but we can get satisfactory and useful information. Acquired resistivity section and video tapes by borehole camera logging will be reserved and reused if some problem occurs in this site in the future.

  • PDF

Comparative Study on Color of Environment Evaluation of General Classrooms at Elementary Schools - With elementary schools in Gwang-ju Metropolitan City Since the 7th Curriculum - (초등학교 일반교실의 색채 환경 평가에 관한 비교연구 - 제7차 교육과정 전.후의 광주광역시내 초등학교를 중심으로 -)

  • No, Young-Ran;Park, Sung-Jin;Lee, Cheong-Woong
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.5
    • /
    • pp.89-97
    • /
    • 2007
  • This study compares, analyzes and reevaluates color conditions and images before and after the execution of the 7th curriculum with elementary schools in Gwang-ju Metropolitan City based on the fact that color among physical environments of elementary classrooms has an important influence on children's emotion and draws problems and aims to accumulate the basic materials for preparing guidelines of improving color environment at general classrooms of elementary schools. Consequently, according to color conditions, major colors on ceiling and wall were high brightness/nigh chroma of Y and YR line regardless of division of grades and other color factors of classroom showed that wall and ceiling used similar colors, but brightness was higher after change than before it. In evaluation of color images, lower grades showed negative color images such as 'common,' 'rustic,' and 'strange' before change, but they showed positive color images after change such as 'clean,' 'unique,' and 'soft'. But, most of higher grades showed negative reactions before change such as 'common,' 'strange,' and 'rustic' and they showed positive reactions after change only in such items as 'clean,' 'warm,' and 'unique', but Indicated negative reactions in remaining items such as 'strange,' 'rustic,' 'stiff,' and 'artificial'. Accordingly, in using colors for lower grade classroom, arrangement of colors through adjustment of brightness and chroma between ceiling, wall and other components based on coloring of high brightness and low chroma of similar colors should be considered and for higher grade classroom, arrangement of colors of unique images of mid-brightness/mid-chroma among warm color lines of similar colors should be examined.