• Title/Summary/Keyword: ceiling

Search Result 983, Processing Time 0.03 seconds

A Study on the Process Optimization of Microcellular Foaming Injection Molded Ceiling Air-Conditioner 4-Way Panel (초미세발포 사출성형을 이용한 천정형 에어컨 4-way 판넬의 공정 최적화에 관한 연구)

  • Kim, Joo-Kwon;Lee, Jung-Hee;Kim, Jong-Sun;Lee, Jun-Han;Kwak, Jae-Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.98-104
    • /
    • 2018
  • Deflected 4-way panels of ceiling air conditioners produced by injection molding process have caused dew condensation at the edge of products. In order to prevent this drawback with reducing weight and deformation, this study proposed renovated process adopting microcellular foaming. According to results from 2-sample t-test and analysis of variance(ANOVA), the critical factors affecting weight were melt temperature and injection speed. In addition, the vital effects on deformation were structure at the edge, mold temperature and cooling time. Optimal conditions of these parameters were derived by regressive analysis with CAE and response surface method(RSM), and then applied to an actual design and process stage to analyze performance. As a results, it clearly showed that new process improved process capability as well as reduced both weight and deformation by 18.8% and 71.9% respectively compared to the conventional method.

Evaluation of the clean air delivery rate performance of a ceiling air circulator with filters (필터 적용 천정형 공기순환기의 공기청정화능력 평가)

  • Joe, Yun-Haeng;Shin, Dongho;Park, Hyun-Seol;Heo, Jieun;Shim, Joonmok
    • Particle and aerosol research
    • /
    • v.17 no.2
    • /
    • pp.29-36
    • /
    • 2021
  • In this study, the clean air delivery rate (CADR) of ceiling air circulator (CAA) was determined under indoor environmental simulation conditions. An air filter was used to provide air cleaning ability to the CAA. The CADR of filter adapted CAA was evaluated and compared with the value of commercial air purifier. The installation of mesh-shaped filter on the CAA showed particle reduction effect on the particles over 0.4 ㎛ in diameter, but the CADR was up to 0.25 m3/min. When the filter having 99.9% in collection efficiency was installed on the CAA, its CADR was 1.52 m3/min, while the CADR of commercial air purifier was 3.19 m3/min.

Assessment of structural behavior of reinforced concrete slab ceiling under full load test in a residential complex project

  • Jaffar A. Kadim;Oday A. Abdulrazzaq;Abdulamir A. Karim;Aqeel H. Chkheiwer
    • Structural Engineering and Mechanics
    • /
    • v.89 no.6
    • /
    • pp.627-634
    • /
    • 2024
  • This research deals with the process of conducting a reinforced concrete slab loading test of a Residential Complex Project at the Shatt Al Arab District which is located in southern Iraq. The purpose of the test which represents a destructive test is to evaluate the structural behavior of the slab condition state during and after the examination of the test process in order to ascertain the ability of the slab ceiling to withstand the loads generated during the use of the building. The test was carried out accordant to ACI 437.2-13 code. The reason for this test is the postponed 8 years of building project construction. Concrete blocks were used to simulate and conduct a loading test of 30-tons for 3 days. The central point has been installed to measure the slab deflection that occurred during the test. The results showed that both the total deflection and residual deflections were lesser than the permissible values according to the ACI 437.2-13, the RC slab behavior was mainly linear structural behave, and that the purpose of the examination was achieved. Finally, a new method was introduced to the assessment of the slab condition at the support which is found in good condition.

Fire Simulation for Vent Flow and Temperature in Engine Room of Small Ship: Effects of Ceiling Duct Location and Side Vent Size (소형선박 기관실의 개구부 유동 및 온도에 대한 화재시뮬레이션: 천장 통풍통 위치 및 측면 개구부 크기 영향)

  • Jeong, Lee-Gyu;Lee, Chi Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.5
    • /
    • pp.454-465
    • /
    • 2020
  • Fire simulations were performed using the Fire Dynamics Simulator (FDS) software to examine the vent flow and temperature in the engine room of a small ship. A diesel fire with a heat release rate of 10 kW was targeted, and the effects of the ceiling duct location, side vent existence and nonexistence, and side vent size were investigated. The existence or nonexistence of the side vent and its size considerably affected the smoke behavior, mass flow rate through the vent, and temperature. When the side vent was not installed or was small, the smoke layer reached the floor in the engine room. In addition, as the side vent size increased, the mass flow rate through the vent increased with decreasing temperature value. However, the effects of the ceiling duct location on the smoke behavior, mass flow rate through the vent, and temperature seemed to be relatively minor compared to those of the side vent size. Therefore, to improve the fire safety of the engine room in a small ship, the side vent size is considered to be a more important design factor than the ceiling duct location.

A study on Improvement and Invigoration of Cooperation Charge on Conservation Ecosystem Fund (생태계보전협력금 제도 활성화를 위한 부과금 개선 방안 연구)

  • Kim, Gyung-Ho;Lee, Sang-Houck
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.14 no.6
    • /
    • pp.97-109
    • /
    • 2011
  • Korea introduced the cooperation charge on conservation of ecosystem for minimizing damage of ecosystem due to development projects and their effects and for preparing resources for natural environment conservation projects. Advanced countries have made efforts by expanding investment in natural environment conservation and restoring projects to promote prevention of global warming and improvement of biological diversity, are establishing nationwide strategies and plans. To examine the reality of projects by returns of the cooperation charge on conservation of ecosystem, microsite projects in schools and public facilities take the largest share while their project budgets are only about 100~300 KRW, relatively small, which might be attributable to budget restrictions in accordance with the calculating method of levying cooperation charge on conservation of ecosystem and problems of project proceeding in the system of returning fund for projects in general. The conclusion which this study suggests on invigoration of cooperation charge on conservation of ecosystem and its operation are as followings. First, although the cooperation charge on conservation of ecosystem has been introduced in 2001, the amount of imposition per unit area remains unchanged. It is desirable to increase the amount into $1,400KRW/m^2$ as of August, 2011 as the price index has been continuously rising for the past 10 years and the upward adjustment of imposition per unit area should be notified by the decree of the Ministry of Environment every January. Second, the ceiling amount of the cooperation charge on conservation of ecosystem should be abolished. Now the ceiling amount is defined as 1 billion KRW but it was found that there was not any ceiling amount specified according to the comparative analysis of similar systems with the Korean environmental improvement fund. The ceiling should be abolished so that medium level businesses are carried out and ecosystem recovering projects in the true sense of the word can be made smoothly. Third, weight should be introduced in calculating amounts in accordance with ecologic and economic values. Harmony between development and environment can be achieved by applying differentiated weights of constant regional coefficient by use zone and ecologic and economic values. Continuous efforts of improving cooperation charge on conservation of ecosystem should be made more than anything else so that projects by returns of cooperation charge on conservation of ecosystem get effectiveness.

Optimal Scheduling for Efficient Waste Management in Isolated Regions from the Perspective of Waste Reduction Incentives (폐기물 저감 인센티브를 고려한 고립지역의 효율적 폐기물 관리 스케줄)

  • Hwang, Seok-Joon;Hwang, Uk;Kim, Hyun-Cheol
    • Environmental and Resource Economics Review
    • /
    • v.26 no.3
    • /
    • pp.399-416
    • /
    • 2017
  • This study examines the problem of efficient scheduling of waste collection in isolated regions like islands when the waste accumulated amount surpasses the standard ceiling by effectively tracking the accumulating trends based on the optimum checking model of Keller (1974). To grasp whether the waste accumulated amount in isolated regions exceeds the standard ceiling, the relevant authorities can tightly check during a set period, but this entails higher monitoring costs. On the other hand, if the accumulated waste over the ceiling is not immediately checked and collected, and continues for a set period of time, innovative efforts for waste management may be highly demanded. As such, the tradeoffs are considered to draw the optimal checking schedule. This study shows that the authorities get to check less frequently the waste accumulation trends if the monitoring costs increase or when the failure rate of waste management systems drops. On the other hand, they get to check more frequently if the accumulated waste amount in isolated regions exceeds the standard ceiling and welfare loss grows as a result. It also shows that frequent checking is the optimal choice if the social marginal benefits enjoyed from innovative efforts made to keep accumulated waste below the standard ceiling, are not significant.

Shaking table tests of prestressed damping-isolation units using a spring and rubbers

  • Yang, Keun-Hyeok;Mun, Ju-Hyun;Im, Chae-Rim;Won, Eun-Bee
    • Earthquakes and Structures
    • /
    • v.23 no.4
    • /
    • pp.373-384
    • /
    • 2022
  • To improve the seismic performance of suspended ceiling structures, various vibration-damping devices have been developed. However, the devices made of metals have a limit in that they cause large deformation and seriously damages the exterior of the suspended ceiling structure from the wall. As a results, their strengthening effect of the suspended ceiling structure was minimal. Thus, this study employed a spring and vibration-proof rubber effectively controlled vibrations without increasing horizontal seismic loads on the ceiling to enhance the seismic resistance of suspended ceiling structures. The objective of the study is to examine the dynamic properties of a seismic damping-isolation unit (SDI) with various details developed. The developed SDI was composed of a spring, embossed rubbers, and prestressed bolts, which were the main factors enhancing the damping effect. The shaking table tests were performed on eight SDI specimens produced with the number of layers of embossed rubber (ns), presence or absence of a spring, prestressed force magnitude introduced in bolts (fps), and mass weight (Wm) as the main parameters. To identify the enhancement effect of the SDI, the dynamic properties of the control specimen with a conventional hanger bolt were compared to those of the SDI specimens. The SDI specimens were effective in reducing the maximum acceleration (Ac max), acceleration amplification factor (αp), relative displacement (δR), and increasing the damping ratio (ξ) when compared to the control specimen. The Ac max, αp, and δR of the SDI specimens with two rubbers, spring, and fps of 0.1fby, where fby is the yielding strength of the screw bolt were 57.8%, 58.0%, and 61.9% lower than those of the conventional hanger bolt specimens, respectively, resulting in the highest ξ (=0.127). In addition, the αp of the SDI specimens was 50.8% lower than those specified in ASCE 7 and FEMA 356. Consequently, to accurately estimate the αp of the SDI specimens, a simple model was proposed based on the functions of fps, stiffness constant of the spring (K), Wm, and ns.