• Title/Summary/Keyword: cavity detection

Search Result 185, Processing Time 0.019 seconds

Conceptual design and preliminary characterization of serial array system of high-resolution MEMS accelerometers with embedded optical detection

  • Perez, Maximilian;Shkel, Andrei
    • Smart Structures and Systems
    • /
    • v.1 no.1
    • /
    • pp.63-82
    • /
    • 2005
  • This paper introduces a technology for robust and low maintenance cost sensor network capable to detect accelerations below a micro-g in a wide frequency bandwidth (above 1,000 Hz). Sensor networks with such performance are critical for navigation, seismology, acoustic sensing, and for the health monitoring of civil structures. The approach is based on the fabrication of an array of high sensitivity accelerometers, each utilizing Fabry-Perot cavity with wavelength-dependent reflectivity to allow embedded optical detection and serialization. The unique feature of the approach is that no local power source is required for each individual sensor. Instead one global light source is used, providing an input optical signal which propagates through an optical fiber network from sensor-to-sensor. The information from each sensor is embedded onto the transmitted light as an intrinsic wavelength division multiplexed signal. This optical "rainbow" of data is then assessed providing real-time sensing information from each sensor node in the network. This paper introduces the Fabry-Perot based accelerometer and examines its critical features, including the effects of imperfections and resolution estimates. It then presents serialization techniques for the creation of systems of arrayed sensors and examines the effects of serialization on sensor response. Finally, a fabrication process is proposed to create test structures for the critical components of the device, which are dynamically characterized.

Air detector using the change of dielectric constant for medical applications (의료분야 응용을 위한 유전상수 변화를 이용한 공기감지 장치)

  • Kim, Kyung-Hwa;Shim, Joon-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.864-870
    • /
    • 2010
  • Air embolism can be a lethal complication of surgical procedures during which venous pressure at the site of surgery is sub-atmospheric or air is forced under pressure into a body cavity. To solve the problem, we developed the air detector using relative dielectric constant change, which is expected to be used broadly in industrial circles. We designed air detection system with air control equipment, detection circuit and LabVIEW system for air sensing. In experiments with a mock system, the proposed system showed a signal difference depending on the amount of air in the Tygon tube of the mock system.

Effects of Daihwangmudan-tang on Urate Lowering and Detection of Relevant Genes (대황목단탕(大黃牧丹湯)의 요산지표 개선효과와 관련 유전자 탐색)

  • Kim Joong-Bae;Chi Gyoo-Yong;Eom Hyun-Sup
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.6
    • /
    • pp.1534-1540
    • /
    • 2005
  • In order to testify the urate lowering effects of Daihwangmudan-tang(DMT), ICR mice were injected monosodium urate into the abdominal cavity and then DMT was administered on 2 and 4 days after Injection. Uric acid and triglyceride were measured as hematological indices of gout, and some genes related with this change were identified by ACP based GeneFishing PCR method and direct sequencing. From this experiment, DMT highly decreased the blood levels of uric acid and significantly suppressed and lowered the acute increment of triglyceride level. There were 11 differentially expressed genes(DEG) having relations with positive actions of DMT, and 4 major genes in the middle of DEGs were sequenced; Mfap 2, jagged 2, Hsd17b7, DkkI-1, These genes were supposed that several mechanisms through interleukin 1 and T-cell anergy, LDL cholesterol metabolism, wnt pathway would be related with the anti-inflammation effect against gout.

Development of High-Sensitivity Cantilever-Detected ESR Measurement Using a Fiber-Optic Interferometer

  • Tokuda, Yuki;Tsubokura, Daichi;Ohmichi, Eiji;Ohta, Hitoshi
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.173-177
    • /
    • 2013
  • Cantilever-detected high-frequency electron spin resonance (ESR) is a powerful method of sub-terahertz and terahertz ESR spectroscopy for a tiny magnetic sample at low temperature. In this technique, a small magnetization change associated with ESR transition is detected as deflection of a sample-mounted cantilever. So far, we have succeeded in ESR detection at 370 GHz using a commercial piezoresistive microcantilever. The spin sensitivity was estimated to ${\sim}10^{12}$ spins/gauss. In order to further increase the sensitivity, we adopt a fiber-optic-based detection system using a Fabry-Perot interferometer in place of piezoresistive system. Fabry-Perot cavity is formed between an optical-fiber end and microcantilever surface, and a change in the interference signal, corresponding to the cantilever deflection, is sensitively detected. This system is suitable for low-temperature and high-magnetic-field experiments because of its compact setup and less heat dissipation. In this study, performance of Fabry-Perot interferometer is evaluated, and its application to cantilever-detected ESR measurement is described.

Microgravity for Engineering and Environmental Applications (토목.환경 응용을 위한 고정밀 중력탐사)

  • Park, Yeong-Sue;Rim, Hyoung-Rae;Lim, Mu-Taek
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.12a
    • /
    • pp.15-25
    • /
    • 2007
  • Gravity method could be one of the most effective tool for evaluating the soundness of basement which is directly correlated with density and its variations. Moreover, Gravimeter is easy to handle and strong to electromagnetic noises. But, gravity anomaly due to the target structures in engineering and environmemtal applications are too small to detect, comparing to the external changes, such as, elevation, topography, and regional geological variations. Gravity method targeting these kinds of small anomaly sources with high precision usually called microgravity. Microgravimetry with precision and accuracy of few ${\mu}Gal$, can be achieved by the recent high-resolution gravimeter, careful field acquisition, and sophisticated processing, analysis, and interpretation routines. This paper describes the application of the microgravity, such as, density structure of a rock fill dam, detection of abandoned mine-shaft, detection and mapping of karstic cavities in limestone terrains, and time-lapse gravity for grout monitoring. The case studies show how the gravity anomalies detect the location of the targets and reveal the geologic structure by mapping density distributions and their variations.

  • PDF

An Experimental Study on the Detection of Loosened Areas in a Ground cavity Using a Micro Penetration Test (초소형 관입시험기를 이용한 지반공동 주변지반의 이완영역탐지를 위한 실험적 연구)

  • Kim, Ho-Youn;Kim, Young-Ho;Park, Yoon-Suk;You, Seung-Kyong;Han, Jung-Geun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.299-306
    • /
    • 2019
  • In this study, a model experiment that simulates the behaviour of the ground composed of several compacted layer was intended to measure the loosened area in the event of a ground cavity through a LAD (Loosened area detector). It was confirmed that the size of the cone diameter was affected by the ground composed of fine grain + granulated soil layered through the model soil. In order to select the appropriate cone type, a scale effect experiment was conducted. From the test results, a micro-cone was chosen for the most suitable indoor model experiment. In the case of applying LAD in this study, the loosening condition of the ground was determined by the rapid change in penetration resistance caused by the difference in the boundary surface and relative density due to the compaction of the ground for indoor model testing. The range of loosened area occurring in the cavity was estimated through the penetration resistance characteristics on the ground, and the failure area was identified through the reduction rate of penetration resistance in the loosening area.

GG Tauri A: gas properties and dynamics from the cavity to the outer disk

  • Nguyen, Thi Phuong;Dutrey, Anne;Pham, Ngoc Diep;Chapillon, Edwige;Guilloteau, Stephane;Lee, Chang Won;Di Folco, Emmanuel;Majumdar, Liton;Bary, Jeff;Beck, Tracy L.;Coutens, Audrey;Denis-Alpizar, Otoniel;Melisse, Jean-Paul;Pietu, Vincent;Stoecklin, Thierry;Tang, Yei-Wen
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.38.2-39
    • /
    • 2021
  • I will presents the analysis of the gas properties of the protoplanetary disk surrounding the young low-mass (about 1.2Msun) triple star, GG Tau A. This work makes use of ALMA observations of rotational lines of CO (12CO, 13CO and C18O) together NOEMA observations of a few dozens of other molecules. While the CO emission gives information on the molecular layer close to the disk atmosphere, its less abundant isotopologues 13CO and C18O bring information much deeper in the molecular layer. I will present the analysis of the morphology and kinematics of the gas disk using the CO isotopologues. A radiative transfer model of the ring in CO isotopologues will also be presented. The subtraction of this model from the original data reveals the weak emission of the molecular gas lying inside the cavity. Thus, I am able to evaluate the properties of the gas inside the cavity, such as the gas dynamics, excitation conditions, and the amount of mass in the cavity. High angular resolution observations of CO reveals sprials induced by embedded planet(s) located near the 3:2:1 mean-motion resonance that help to explain the special morphology of the circumbinary disk. I also discuss some chemical properties of the GG Tau A disk. I report the first detection of H2S and C2S in a protoplanetary disk. The molecule abundance relative to 13CO of about twenties other molecules will also be given. In GG Tau A, the detections of rare molecules such as H2S and C2S have been probably possible because the disk is more massive (a factor about 3-5) than other disks where the molecules was searched. Such a large disk mass makes the system suitable to detect rare molecules and to study cold-chemistry in protoplanetary disks.

  • PDF

Signal processing of interferometric fiber-optic sensor utilizing a digital homodyne detection (디지털 호모다인 검출방식을 이용한 간섭형 광섬유센서의 신호처리)

  • 예윤해
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.1
    • /
    • pp.62-69
    • /
    • 1995
  • 레이저 다이오드 구동 전류펄스기간의 발진주파수 변조와 간섭계 출력신호의 시간지연 샘플링을 이용하여 3x3 coupler등과 같은 특수 광부품을 사용하지 않고도 1개씩의 광원과 광검출기를 이용하여 측정신호의 변화방향과 함께 half fringe의 수를 count할 수 있으며 광연결선 주변환경의 변화에 의한 세기변화 에러도 피할 수 있는 간섭형 센서를 위한 새로운 신호처리방식을 제안하고 이 방식을 거울내장형 FP간섭계를 이용한 온도센서에 적용하였다. 온도센서소자로 cavity length가 1cm인 FP간섭계를 이용하여 실온에서 360.deg.C에 걸쳐 분해능 2.7.deg.C로 측정하였으며 이때 최대측정속도는 $ 1.378*10^{5}$.deg.C/sec로 계산되었다. 이 방식에서 분해능과 최대측정속도는 반비례 관계를 가지며 감지 광섬유의 길이에 비례하여 분해능을 높일 수 있다. 또한 6개까지의 센서소자를 한개의 광원과 광검출기로 모니터하는 다중화 센싱 또한 가능한 신호처리 방식으로써 불평형 간섭계를 이용한 모든 종류의 센서에 대해 적용이 가능하다.

  • PDF

Vibration Control of a Composite Plate with Attached FBG Sensor (FBG 센서를 부착한 복합재 평판의 진동 제어)

  • Kim, Do-Hyung;Chang, Young-Hwan;Han, Jae-Hung;Lee, In
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.04a
    • /
    • pp.14-17
    • /
    • 2003
  • Vibration control of a composite plate with a surface-bonded fiber Bragg grating (FBG) sensor and piezoceramic actuators has been performed using a neural network based adaptive predictive control algorithm. For the detection of Bragg wavelength changes, two cavity lengths in Fabry-Perot read-out interferometers are used in order to produce two quadrature phase shifted signals. The FBG sensor system and real-time neuro-adaptive control algorithm could be applicable to diverse dynamic systems.

  • PDF

Lip Region Extraction by Gaussian Classifier (가우스 분류기를 이용한 입술영역 추출)

  • Kim, Jeong Yeop
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.2
    • /
    • pp.108-114
    • /
    • 2017
  • Lip reading is a field of image processing to assist the process of sound recognition. In some environment, the capture of sound signal usually has significant noise and therefore, the recognition rate of sound signal decreases. Lip reading can be a good feature for the increase of recognition rates. Conventional lip extraction methods have been proposed widely. Maia et. al. proposed a method by the sum of Cr and Cb. However, there are two problems as follows: the point with maximum saturation is not always regarded as lips region and the inner part of lips such as oral cavity and teeth can be classified as lips. To solve these problems, this paper proposes a method which adopts the histogram-based classifier for the extraction of lips region. The proposed method consists of two stages, learning and test. The amount of computation is minimized because this method has no color conversion. The performance of proposed method gives 66.8% of detection rate compared to 28% of conventional ones.