• 제목/요약/키워드: cavity core

검색결과 120건 처리시간 0.025초

A rare histopathological variant of Schwannoma with rosette-like arrangements and epithelioid cells: a case report from a histopathologist's perspective

  • Monica Mehendiratta;Vikas Kumar Sant;Manisha Lakhanpal;Keerti Chauhan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제49권4호
    • /
    • pp.233-238
    • /
    • 2023
  • Schwannomas exhibit histopathological variation that leads to diagnostic dilemmas, although less frequent in the oral cavity. We describe a case with unique histopathology and no relevant clinical history that adds to the breadth of literature on the diversity presented by Schwannoma. A 60-year-old female patient presented with a small dome-shaped, asymptomatic swelling on the alveolar ridge 6 years in duration. Histopathologically, it showed rich cellular pathology with a unique arrangement of tumor cells forming irregular rosettes. Each rosette presented with a central core of fibrin-collagenous material and the tumor cells were arranged on the periphery, exhibiting epithelioid change with evidence of mild cellular and nuclear pleomorphism. On immunohistochemical evaluation, the cells were strongly and diffusely positive for S-100 and negative for Ki-67. A diagnosis of benign Schwannoma with a rosette-like arrangement with epithelioid change was made. The case report emphasizes the risk of misdiagnosis and the importance of awareness regarding rare histopathological variants of Schwannoma.

토양 코아 분석을 통한 화산 골프장의 조성된 그린에 대한 평가 (The Evaluation on the exiting greens of Hwasan Country Club by undisturbed Soil Core Analysis)

  • 이상재;허근영;심경구
    • 한국조경학회지
    • /
    • 제26권2호
    • /
    • pp.54-61
    • /
    • 1998
  • The subsurface environment of the root zone area can set the stae for "do or die" of the turfgrass plant. The good condition of the greens is verified by their physical properties. Therefore, this study was carried to evaluate on the existing green of Hwasan C.C. by undisturbed soil Core Anaysis. We completed the ISTRC SYSTEM BenchMarking of the undisturbed core samples taken from Green #1, Green #5, Green #9-"Best" area, and Green #9-"Stressed" area for the Hwasan C.C.. It was also our understanding that the greens were in "good" to "very good" conditioni. THe exception might be Green #9-"Stress" area, which was the stressed area. The stressed area was confined to a ridge across Green #9. The organic content test results comfirmed the development of organic layering in depth 0-2.5cm. For the amount of compaction in the upper root zones and te development of the green's respective organic layers, the infiltration rates were high in Green #1, Green #5, and Green #9 "Stressed" area. The depicted aerificaton hole might be the probable cause of the relatively high infiltraton rate. Green #9-"Best" area had a tested infiltration rate of 18.75cm/hr. Either this area had not been aerified, or the undisturbed sample did not contain a aerification cavity. The water retention capacity of the undisturbed samples was good. When the greens were first constructed, the original root zone mix had been relatively low water retention properties. And the bulk density and the porosity of the undisturbed samples were good. In the result, all the greens were similar except for the infiltration. Thus, we supposed that Green #9-"Stressed" area might be ainly influenced by the amount of irrigation water and the configuration of the green's surface. There had been a reduction in the amount of irrigation water as the water retention capacity in the greens was promoted. Especially, it had gradually become more of a problem as the green had matured in Green #9-"Stressed" area. Because Green #9-"Stressed" area was a ridge area. The reduction in the amount of irrigation water might be the probable cause of the stress in Green #9-"Stressed" area. Our final observation related to the soil texture and the particle size distribution of the sand. Though and sand contant of all the tested greens were good, the gravel content of them exceeded ISTRC Guidelines. In particle size distribution of the sand, the very coarse and the coarse content of all the tested greens exceeded, but the rest was insufficient. The stability is a function of the material retained on the 0.25mm mesh screen. But, the content of all the tested greens was very insufficient. Though all the greens was serviceable, the coarse root zone sands, such as the sand in the tested greens, tended to be "unstable". Thus, we recommend using a topdressing/aerification sand which should be more in line with ISTRC/USGA Guidelines.;unstable". Thus, we recommend using a topdressing/aerification sand which should be more in line with ISTRC/USGA Guidelines.ines.

  • PDF

고리 1호기 소형파단 냉각제 상실사고에 의해 개시된 가상 노심용융 사고 해석 (Severe Accident Sequence Analysis - Part 1: Analysis of Postulated Core Meltdown Accident Initiated by Small Break LOCA in Kori-1 PWR Dry Containment)

  • Jong In Lee;Seung Hyuk Lee;Jin Soo Kim;Byung Hun Lee
    • Nuclear Engineering and Technology
    • /
    • 제16권3호
    • /
    • pp.141-154
    • /
    • 1984
  • 고리 1호기의 소형파단냉각재 상실사고에 의해 개시된 중대사고 유형과 그 현상에 대할 분석이 제시되었다. 본 해석에서는 KAERI에서 기존 전산코드의 수정.보완된 MARCH 전산코드가 사용되었다. 특히 고리 1호기의 소형파단 LOCA 해석시 수소 거동과 중기과압에 대한 평가 및 그 응답성에 중점을 두고 검토되었으며, 2-loop 발전소 데이타 분석 및 debris-Water 상호작용 모델에 대한 비교 분석이 수행되었다. 제 1부 중대 사고유형 분석결과, 저농도에서 H$_2$ burning이 이루어지는 경우 계속적인 수소 생성으로 인해 반복 수소 spike가 야기 되나, 격납용기 설계압력치 보다낮게 예측되었다. 또한 debris/water 상호작용시 core debris의 입자크기는 첨두압력의 크기에 미치는 영향은 미세하나 첨두압력의 발생시점은 dryout모델사용에 의해서 상당히 지연시키게 되었다. 완전한 노심용융 사고시 수소연소와 증기과압으로부터 예측된 격납용기 최대압력은 격납용기 건전성에 심각한 위협을 초래하지 않는 것으로 나타났다.

  • PDF

비접촉식 광 점퍼 코드 개발 및 광 전송 성능 평가 (Development of Non-Contact Fiber Jumper Cord and Evaluation of Light Transmission Performance)

  • 김헌영;강동훈
    • 비파괴검사학회지
    • /
    • 제36권5호
    • /
    • pp.399-405
    • /
    • 2016
  • 최근 많은 장점으로 기존 전기식 센서를 대체하여 그 적용 영역을 빠르게 넓혀가고 있는 광섬유 센서는 센서부에서 계측기 사이의 신호 전달을 위해 광 어댑터와 광 점퍼 코드와 같은 광소자를 사용하게 된다. 광 어댑터를 이용하여 신호 전달을 하는 경우 단면이 서로 맞닿게 되어 이물질에 의해 코어 부분에 손상이 발생할 수 있으며, 이는 광 손실 및 광 접속 불능을 유발할 수 있다. 따라서, 본 연구에서는 지속적인 유지보수를 필요로 하는 문제들을 근원적으로 해결할 수 있는 대안으로 비접촉식 광섬유 점퍼 코드를 개발하였으며 그 전송 성능을 평가하였다. 시험 결과, 기존의 접촉식 광 점퍼 코드는 2 mm의 간극에서 광 신호 전송이 불가능한데 반해 비접촉식 광 점퍼 코드의 경우 초기 광 손실은 상대적으로 크지만 간극이 증가하더라도 약 7 mm 정도까지 안정적으로 신호 전송이 가능하였다. 따라서, 패치 코드가 광센서 간 신호 전송을 위한 케이블임을 고려할 때 외부의 환경적 요인에 대해 더 우수한 신호 안정성을 가진 비접촉식 패치 코드가 접촉식 패치 코드에 비해 현장 적용성이 더 뛰어남을 확인하였다.

피조개, Scapharca broughtonii 외투막 상피층의 미세구조 (Ultrastructure of the Mantle Epidermis in the Ark Shell, Scapharca broughtonii (Bivalvia: Acridae))

  • 이정식
    • Applied Microscopy
    • /
    • 제32권3호
    • /
    • pp.213-222
    • /
    • 2002
  • 피조개의 외투막은 바깥 상피층, 결합조직층 그리고 안쪽 상피층으로 구성되어 있다. 상피층은 단층으로 지지세포, 섬모세포 및 분비세포들로 구성되며, 결합조직층은 주로 교원섬유와 근섬유로 이루어져 있다. 안쪽 상피층의 지지세포들은 원주형으로 자유면은 미세융모로 덮여있다. 섬모세포들은 자유면에 섬모와 미세융모를 가지며, 이들 세포의 세포질 상부에서는 다수의 관상 미토콘드리아들이 관찰된다. 분비세포들은 주로 바깥 상피층에서 관찰되며, 분비과립의 형태학적 특징에 따라 A, B, C, D 네 종류로 구분할 수 있다. A형 분비세포들은 점액세포들로서 가장자리와 중앙부의 외투막에서 주로 관찰되며, 이들 세포의 분비과립은 전자밀도가 낮고 막을 가지지 않는다. B형 분비세포들은 발달된 다수의 조면소포체와 골지체 그리고 전자밀도가 높고 막을 가진 분비과립들을 함유한다. C형 분비세포들의 분비과립은 섬유성분의 중심부와 균질성의 주변부로 구분된다. D형 분비세포들은 주로 중앙부와 각정부 외투막의 바깥 상피층에서 관찰되며, 이들 세포의 분비과립은 균질성의 중심부와 과립상의 주변부로 구분된다. 이와 같은 결과들은 피조개 외투막의 바깥 상피층은 패각형성에 관여하며, 안쪽 상피층은 외투강 정화에 관여함을 의미한다.

꼬막(Tegillarca granosa) 외투막의 미세구조 (Mantle Ultrastructure of the Granular Ark, Tegillarca granosa (Bivalvia: Acridae))

  • 마경화;이정식
    • 한국수산과학회지
    • /
    • 제36권3호
    • /
    • pp.270-275
    • /
    • 2003
  • Histochemical characteristic and ultrastructure of the mantle of the granular ark, Tegillarca granosa are described using light and electron microscopy. The mantle of the clam is composed of outer epidermis, connective tissue and inner epidermis. The simple epidermis consists of supporting cells, ciliated cells of the two types and secretory cells of three types. Connective tissue is composed of matrix, collagen fibers, muscular fibers and hemolymph sinus. The columnar supporting cell is covered with microvilli on the free surface. Ciliated cells are distributed in the inner epidermis with numerous cilia, microvilli and tubular mitochondria. Secretory cells could be classified into three types (A, B and C) with morphological features of the secretory granules. Type A secretory cells contains secretory granules with fibrous materials of high electron density Type B secretory cells are more abundant than the other cells, and contains secretory granules of membrane-bounded and high electron density. Secretory granules of the type C cells are divided into fibrous core layer and homogeneous peripheral layer. Type B secretory cells are abundant in the both epidermis of marginal mantle, while large number of type A and C secretory cells are evident in the outer epidermis of the central and umbonal mantle. This result showed that the outer and the inner epidermis of the mantle are related with shell formation and cleaning of the mantle cavity, respectively.

레이저에 의해 손상된 치아경조직 및 치수조직의 치유과정에 대한 연구 (HEALING PROCESS OF DENTAL HARD TISSUES AND PULP TISSUE AFTER LASER IRRADIATION)

  • 김철순;민병순;최호영;박상진;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.20-42
    • /
    • 1998
  • The present study was designed to understand the basic principles of the laser system and to assess the optimal coditions of the Nd:YAG laser irradiation system in order to expand the use of the laser system in the dental field. The laser system used in this study was a pulsed-wave output type and the power level is 9 watts. The incisors of developing rats were irradiated with the laser system explained above for 0.5, 1, and 2 seconds giving energy density 71, 167, and 215 J/$cm^2$ respectively. The rats were sacrificed just after irradiation or 10 minutes and 10 days after irradiation. The specimens were examined with the stereoscope, light microscope and transmission electron microscope. The results are as follows: 1. The tissue removal efficiency (depth of the cavity formed) is increased with the energy density after Nd:YAG laser irradiation. 2. The carbonized area is increased with the energy density. Cracks and melted appearance are seen in all kinds of the energy densities. 3. The lacunae in the damaged alveolar bone by the laser irradiation were empty, while those in the newly formed bone were occupied with the osteocytes. The damaged alveolar bone was repaired by the osteoblasts and macrophages on the periphery of the bone matrix. 4. The damaged enamel was replaced by the loose connective tissues showing many kinds of cells. The ameloblasts were differntiated on the replaced loose connective tissue. 5. The damaged dentin was repaired by the irregular dentin formed by the odontoblasts differentiated from the mesenchymal cells migrated from the pulp core.

  • PDF

생체골의 열전도성 및 열처리된 골의 염전력 변화에 대한 실험적 연구 (Experimental Studies on Heat Conductivity of Human Bone and Torsional Strength of Pasteurized Porcine Tibia)

  • 박일형;김신근;신동규;인주철
    • 대한골관절종양학회지
    • /
    • 제1권1호
    • /
    • pp.7-16
    • /
    • 1995
  • 인체골 4 시편(specimen)과 돼지 경골 25쌍을 이용하여, 생체골의 열전도성 측정과 열처리후 열처리온도와 시간에 따른 골의 염전력을 실험한 결과를 요약하면 다음과 같다. 인체골에 있어서 골수강을 제거하지 않고 $60^{\circ}C$의 항온식염수에서 열처리하면, 골심부의 온도가 $20^{\circ}C$에서 $58^{\circ}C$에 도달하는데 소요된 시간은 경골근위부가 32분 50초, 대퇴골 원위부가 30.분, $80^{\circ}C$ 항온조에서는 경골근위부가 12분 50초, 대퇴골 원위부가 11분 10초 소요되었다. 돼지 경골간부의 피질골내부(endosteum)에 열전대를 부착하고 뼈 양끝을 밀봉하여 같은 실험을 행한 결과 $50^{\circ}C$까지는 시간에 비례해서 일정한 비율로 온도상승이 이루어 졌으며, $20^{\circ}C$에서 $58^{\circ}C$에 이르는 시간이 $60^{\circ}C$ 항온조에서는 7분, $70^{\circ}C$에서는 3분 30초, $80^{\circ}C$에서는 2분이었다. 따라서 임상에서 골수강을 제거 후 장골의 간부(shaft) 만을 항온조에 달굴때는 골구강내에도 데워진 심염수로 가득차게 되므로 상기 시간의 절반이 못되는 짧은 시간내에 피질골의 내부가 $58^{\circ}C$에 이르리라고 판단되었다. 골수강을 소파하지 않은 돼지 경골을 각각 4쌍씩 우측만을 $60^{\circ}C$ 35분, $80^{\circ}C$ 15분 열처리한 후 실험군의 최대염전력은 대조군과 비교할 때 +7.0%, -5.1%, -3.2%, -4.2%의 변화가 있었고, $80^{\circ}C$ 15분 열처리후는 -4.3%, -3.8%, -1.4%(1예는 실험 오류로 제외됨)의 변화가 있었다. 골수강을 완전 제거한 되재 경골을 각각 4쌍씩 우측만을 $60^{\circ}C$, $70^{\circ}C$, $80^{\circ}C$에서 15분 열처리 후 실험군의 최대염전력은 대조군과 비교할 때 -3.4%, -4.2%, -0.7%, +2.7%의 변화가 있었고, $70^{\circ}C$ 15분 열처리후는 -2.8%, -3.9%, -2.1%(1예는 실험 오류로 제외됨)의 변화가 있었으며, $80^{\circ}C$ 15분 열처리후는 +5.2%, -4.4%, -2.9%, -0.3%의 염전력 변화가 있었다. 그러므로 골수강을 제거하지 않고 $80^{\circ}C$ 35분, $60^{\circ}C$ 15분 열처리 하거나, 골수강을 완전소파 후 $60^{\circ}C$ 15분, $70^{\circ}C$ 15분, $80^{\circ}C$ 15분 열처리해서는 각군사이에 염전력의 유의한 차이는없었다. 이상의 결과로 돼지 경골의 경우 $60^{\circ}C$ 항온에서는 35분까지, $80^{\circ}C$이하의 항온에서는 15분까지 열처리하여도 골강도에는 거의 영향이 없는 것으로 나타났다.

  • PDF

컬러코어스캐너 기법에 의한 금광상 배태 현황 및 성인연구 (A Study of Gold Deposits and Genesis by Using Color-corescanner)

  • 현혜자;황덕환
    • 자원환경지질
    • /
    • 제39권6호
    • /
    • pp.663-674
    • /
    • 2006
  • 금광상에서 암석의 구조, 구조선에 따른 열수의 이동, 천열수 맥 구조, 광화작용상태 및 구성광물등을 정밀하게 분석하는 것은 광상의 배태현황, 천열수에 따른 열수광상의 성인을 확인하는 데 매우 중요하다. 따라서, 본 연구의 목적은 컬러코어스캐너 기법에 의해 구조선에 따른 열수의 이동 및 천열수 맥 구조 등에 대한 정밀한 정보를 통해 금광 배태상황과 성인을 연구하는 데 있다. 컬러코어스캐너 기법은 전남 해남지역 순신 금광산에서 천공된 3개 시추공의 시추코어 전체를 디지털 영상자료(digital image data)화하였다. 디지털 시추코어자료에서는 금이 배태하는 여러 형태의 천열수 맥 구조가 정밀하게 분석되었다. 즉, 빗살구조형, 정동구조형, 엽편상구조형, 각력구조형, 누대구조형 및 혼합구조형 등이다. 또한, 금광상 배태는 대부분 맥상체 형태의 구조들에 많이 배태하나 고품위의 금광은 각력상 형태의 구조내에 많이 배태하고 있음이 특징적이다. 금광상의 성인은 전형적인 천열수 금광상이다. 컬러코어스캐너 기법에 의한 디지털 시추코어 영상자료는 육안관찰에서 빠뜨린 부분을 다시 볼 수 있고, 반복해서 관찰 할 수 있기 때문에 암석내에 발달하는 구조상태 및 광상의 배태 현황 및 광상의 성인을 규명하는데 매우 유익하다고 판단된다.

아래로 향한 수평가열판이 있는 수조에서의 자연대류 (Natural Convection in a Water Tank with a Heated Horizontal Plate Facing Downward)

  • Yang, Sun-Kyu;Chung, Moon-Ki;Helmut Hoffmann
    • Nuclear Engineering and Technology
    • /
    • 제27권3호
    • /
    • pp.301-316
    • /
    • 1995
  • 아래를 향한 가열 수평 평판이 있는 수조에서의 자연대류 현상을 규명하기 위한 실험적, 해석적인 연구를 수행하였다. 이는 압력용기 하부에 용융물이 있을때 캐비티내에서의 열수력현상을 규명하기 위한 간단화된 모델에 관한 연구이다. 압력 용기는 하부에 가열평판이 부착된 직육면체 단열 상자로 모의하고 이 상자는 물이 차 있는 수조에 설치된다. 냉각기는 정상상태의 유동 조건을 만들기 위해 상자와 수조사이의 U자 형태의 유동 영역에 설치된다. 실제 압력용기 하부에서는 다상 유동이 발생할 확율이 크나본 연구는 복잡한 다상 유동의 열수력 현상을 규명하기 위한 첫 단계 시도로서 단상유체를 사용한 실험 및 해석 연구이다. 본 연구에서는 가열 평판 아래에서의 자연대류현상특성을 더욱 잘 이해하기 위해 LDV와 열전대를 사용하여 속도와 온도를 측정하였다. 또한 입자가 부상된 유동장을 사진 찍어 유동을 가시화 하였다. 실험결과는 다음과 같다. 유체는 가열판과 냉각기가 작동할 때 매우 효과적으로 전 유동장에 걸쳐 순환한다. 가열판 하부에서 유동이 정체된 영역이 있고 매우 얇은 열 경계층을 갖는 두드러진 온도의 성층현상이 관찰되었다. FLUTAN Code를 이용한 해석은 속도를 합리 적으로 예측할 수 있다는 결과를 보여 주었다.

  • PDF