• Title/Summary/Keyword: cause of defects

Search Result 622, Processing Time 0.026 seconds

Analysis of Damage Cases of Reinforced Earth Retaining Walls for Expressways at the Time of Introduction 30 Years (도입 30년 시점에서 고속도로 보강토옹벽의 손상사례 분석)

  • Do, Jongnam;Kim, Nagyoung;Kim, Myoungil;Park, Doohee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.12
    • /
    • pp.29-34
    • /
    • 2020
  • Reinforced earth retaining walls were developed in France in the 1970s and began to be applied in earnest to Korea in the 1990s. And now, about 1,300 reinforced soil retaining walls support the embankment of highways and bridge connections. The reinforced earth retaining wall construction technology has evolved day by day, and in recent years the reinforced earth retaining wall itself has been developed and introduced as a demonstration. However, various damages are constantly occurring in the reinforced earth retaining walls constructed throughout the highway. The cause of this was analyzed as minor defects in the design, construction, and maintenance stages. The solution for this is a change in perception of the importance of each individual process, but this does not form overnight. In this study, 30 years have passed since the introduction of the reinforced soil retaining wall on the highway, the damage cases were analyzed and categorized that have occurred in the reinforced soil retaining wall so far, and attempted to present a confrontation. As a result, the damage occurring on the reinforced soil retaining wall was divided into 10 types, and the causes and countermeasures in the design, construction, and maintenance stages for each were derived.

Analysis of a Weak Zone in Embankment Close to a Drainage using Resistivity Monitoring Data (전기비저항 모니터링을 이용한 저수지 제체 취수시설 취약성 해석)

  • Lim, Sung Keun
    • Geophysics and Geophysical Exploration
    • /
    • v.21 no.1
    • /
    • pp.8-14
    • /
    • 2018
  • For the purpose of maintenance and prevention of earth fill dams against damage from natural hazards, automatic monitoring through various measuring instruments and resistivity survey has been carried out. Reservoirs and embankments have the structural vulnerability on the agricultural usages since most of them were built more than thirty years ago. The main aim to use monitoring method is to verify the safety and integrity of the dam. Resistivity survey can detect potential weaknesses, such as defective zones, anomalous seepages or internal erosion processes. Permanent resistivity monitoring systems were installed at a reservoir, which daily measurements have been taken every 6 hour. Using monitoring data for one year, anomalous seepage and structural defects were clarified for dam safety. Annual water level fluctuations are around 10 m. During their operation, reservoir dams are subject to a never-ending hydraulic load from the reservoir, which over the years may cause changes in the properties of the inner parts of the dam construction. Detailed analysis of the monitoring results was performed and showed that resistivities at most locations have been very stable over the full monitoring period excluding the effects of water fluctuation and seasons. To investigate the detectability of weak zone using the DC resistivity monitoring, numerical modeling with a simplified model for the drainage at a reservoir dam was also performed. The results showed that the seepage zone near drainage in a reservoir dam could be detected by resistivity response change.

Characteristic of Local Behavior in Orthotropic Steel Deck Bridge with Open Ribs according to Running Vehicle (주행차량에 따른 개단면 강바닥판 교량의 국부거동 특성)

  • Lee, Sung-Jin;Kyung, Kab-Soo;Park, Jin-Eun;Lee, Hee-Hyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.1
    • /
    • pp.101-108
    • /
    • 2012
  • The orthotropic steel deck bridge made by using relatively thin steel plate, and structural members such as transverse and longitudinal ribs, cross beam, etc. in the bridge are fabricated with complex shape by welding. Therefore, the possibility occurring deformation and defects by welding is very high, and stress states in the welded connection parts are very complex. Also, the fatigue cracks in orthotropic steel deck bridge are happening fromthe welded connection parts of secondary member than main member. However, stress evaluation for main members is mainly carried out in the design process of the bridge, detailed stress evaluation and characteristic analysis is not almost reviewed in the structural details which fatigue crack occurred. For the orthotropic steel deck bridge with open ribs which has been serviced for 29 years, in this study, the cause of fatigue crack is investigated and the fatigue safety of the bridge is examined based on fieldmeasurement by the loading test and real traffic condition. Also, structural analyses using gridmodel and detailed analysis model were carried out for the welded connection parts of longitudinal rib and diaphramthat fatigue crack occurred. Additionally, the behavior characteristics due to running vehicles were investigated by using influence area analysis for these structural details, and the occurrence causes of fatigue crack in the target bridge were clarified.

A Study on Non-Destructive Safety Evaluation Platform of Internal Defects of the Composite Hydrogen Tank using Finite Element Analysis (유한요소해석을 이용한 수소압력용기 비파괴 시험 평가 플랫폼의 안전성 기준 개발 연구)

  • Yongwoo Lee
    • Journal of Platform Technology
    • /
    • v.10 no.4
    • /
    • pp.3-10
    • /
    • 2022
  • In this study, damage resulting from internal flaws was investigated by finite element analysis for the safety evaluation of a non-destructive testing platform for hydrogen pressure vessels. A specimen was modeled and calculated using finite element analysis to determine material properties in accordance with the parameters of the composite material in order to assess the safety of the Type 4 hydrogen pressure vessel. Through this, flaws in the hydrogen pressure vessel were modeled, and test conditions were provided in accordance with rules to look into whether there was safety. Delamination, foreign object, and vertical cracks were modeled for internal flaws, and damage was examined in accordance with failure criteria. As the delamination defect approached the interior of the hydrogen pressure tank, it became more likely to cause damage. Additionally, as the crack depth grew in the case of vertical cracks, the likelihood of crack propagation rose. On the other hand, it was anticipated that the foreign item defect would suffer more damage from the outside in. A non-destructive testing platform will be used to assess the safety of fuel cell vehicles that are already in operation in future research.

A Study on Quality Improvement for the Prevention of Water Infiltration and Corrosion of Helicopter MRA Control-Rod (회전익 항공기 MRA 조종로드 방수 및 부식 방지에 관한 연구)

  • Lim, Hyun-Gyu;Choi, Jae-hyung;Kim, Dae-Han;Jang, Min-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.9
    • /
    • pp.92-100
    • /
    • 2017
  • The Helicopter MRA Control Rod System has the important function of controlling the speed, height, and direction of helicoptersby adjusting the main rotor disc. However, the ingress of water into the inner control rod can cause ice damage in the rod during winter operation and also corrosion;these defects need to be rectified. The water flowed into the control rod through the upper side space, and the rod was cracked during icing expansion occurring at low temperature. The corrosion occurred due to the lack of coating process during the manufacturing process. To resolve these problems, the upper rod was sealed to prevent water inflow and a coating process was added to prevent corrosion. These solutions were verified by awaterproof test and a salt fog test. The phenomena, causes and measures were reviewed and the methods of improvement were established and proven. This proposed technology to prevent water infiltration and corrosion will contribute to the safety of rotary wing aircraft.

Classification of cold regions and analysis of the freeze-thaw repetition cycle based on heat transfer quantity by freezing test (실내동결시험을 통한 열류량 분석에 따른 동결-융해 조건 분석 및 한랭지역의 분류)

  • An, Jai-Wook;Seo, Jeong-Eun;Jung, Min-Hyung;Seong, Joo-Hyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.957-972
    • /
    • 2018
  • Tunnels constructed in cold regions can cause serious defects such as cracks and leaks due to external temperature changes in the portals and vents. In order to prevent the freezing damage of the tunnel, appropriate measures should be applied to the section where the freeze damage is concerned. However, the specific criteria and contents for judging whether or not the anti-freeze measures are applied are not presented. In this study, the laboratory freezing tests on the temperature changes of the concrete specimens under freezing conditions were carried out. And the freeze-thaw repetition cycle (F), which can judge the possibility of freezing damage, were presented based on the heat transfer quantity (W) by experimental results of case studies. Also, we propose a classification of cold regions considering the climatic characteristics of Korea for using it to efficient design and maintenance.

The Incidence and the Patterns of Associated Injuries of Anterior Cruciate Ligament Tear (전방십자인대 파열 시 동반 손상의 빈도 및 양상)

  • Lee, Jung-Hwan;Yoon, Kyoung-Ho;Bae, Dae-Kyung;Eo, Jae-Hyoung;Kim, Jeong-Weon;Park, Soo-Yeon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.24-31
    • /
    • 2008
  • Purpose: We purposed to analyze the incidence and the patterns of the injuries associated with anterior cruciate ligament(ACL) tears. Materials and Methods: We retrospectively reviewed 547 knees that had undergone ACL reconstructions and compared the associated injuries according to the time of injury(acute vs. chronic), the cause of injury(sports vs. non-sports) and the type of sports. Results: Medial collateral ligament(MCL) injury and bone contusion were more in acute injury group less than 3 months after trauma(p=0.001, 0.019) and the injuries of medial or lateral meniscus were more in chronic injury group more than 3 months after trauma(p=0.014, 0.029). The trochlea in acute injury group(p=0.027) and the medial femoral condyle in chronic injury group(p=0.011) had higher incidence of chondral injury. Grade I, II chondral injury was frequent in acute injury group(p=0.016) and grade III, IV chondral injury was frequent in chronic injury group(p=0.017). Lateral meniscus injury was frequent in sports injury group(P=0.035). Medial collateral ligament injury was frequent in ski(P=0.005), and chondral injury was in gymnastics(P=0.017). Conclusions: The incidences of medial and lateral meniscus tears and grade III, IV chondral defects were high in chronic injury group. According to the causes of the tears and the types of sports, some differences in the incidence and pattern of associated injuries were found.

  • PDF

Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition (융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발)

  • Cho, Yong Gwi;Pyo, Sung Jae;Kim, Bong Su;Shin, Chae Ho;Cho, Jin Woo;Kim, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.84-89
    • /
    • 2013
  • Purpose: Patients' movement during long image acquisition time for the fusion image of PET-CT (Positron Emission Tomography-Computed Tomography) results in unconformity, and greatly affects the quality of the image and diagnosis. The arm support fixtures provided by medical device companies are not manufactured considering the convenience and safety of the patients; the arm and head movements (horizontal and vertical) during PET/CT scan cause defects in the brain fundus images and often require retaking. Therefore, this study aims to develop patient-compensation device that would minimize the head and arm movements during PET/CT scan, providing comfort and safety, and to reduce retaking. Materials and Methods: From June to July 2012, 20 patients who had no movement-related problems and another 20 patients who had difficulties in raising arms due to shoulder pain were recruited among the ones who visited nuclear medicine department for PET Torso scan. By using Patient Holding System (PHS), different range of motion (ROM) in the arm ($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$) was applied to find the most comfortable angle and posture. The manufacturing company was investigated for the permeability of the support material, and the comfort level of applying bands (velcro type) to fix the patient's head and arms was evaluated. To find out the retake frequency due to movements, the amount of retake cases pre/post patient-compensation were analyzed using the PET Torso scan data collected between January to December 2012. Results: Among the patients without movement disorder, 18 answered that PHS and $29^{\circ}$ arm ROM were the most comfortable, and 2 answered $27^{\circ}$ and $31^{\circ}$, respectively. Among the patients with shoulder pain, 15 picked $31^{\circ}$ as the most comfortable angle, 2 picked $33^{\circ}$, and 3 picked $35^{\circ}$. For this study, the handle was manufactured to be adjustable for vertical movements. The material permeability of the patient-compensation device has been verified, and PHS and the compensation device were band-fixed (velcro type) to prevent device movements. A furrow was cut for head fixation to minimize the head and neck movements, fixing bands were attached for the head, wrist, forearm, and upper arm to limit movements. The retake frequency of PET Torso scan due to patient movements was 11.06% (191 cases/1,808 patients) before using the movement control device, and 2.65% (48 cases/1,732 patients) after using the device; 8.41% of the frequency was reduced. Conclusion: Recent change and innovation in the medical environment are making expensive medical image scans, and providing differentiated services for the customers is essential. To secure patient comfort and safety during PET/CT scans, ergonomic patient-compensation devices need to be provided. Therefore, this study manufactured a patientcompensation device with vertically adjustable ergonomic ROM according to the patient's body shape and condition during PET Torso scan. The defects in the basal ganglia images due to arm movements were reduced, and retaking was decreased.

  • PDF

SURFACE CHANCE OF EXTERNAL HEXAGON OF IMPLANT FIXTURE AND INTERNAL HEXAGON OF ABUTMENT AFTER REPEATED DELIVERY AND REMOVAL OF ABUTMENT (지대주의 반복적인 착탈에 따른 임플랜트 고정체의 external hexagon과 지대주 internal hexagon의 변화에 관한 연구)

  • Jung Seok-Won;Kim Hee-Jung;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.528-543
    • /
    • 2005
  • Statement of problem: Repeated delivery and removal of abutment cause some changes such as wear, scratch or defect of hexagonal structure. It may increase the value of rotational freedom(RF) between hexagonal structures. Purpose: The purpose of this study was to evaluate surface changes and rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment after repeated delivery and removal under SEM and toolmaker's microscope. Materials and methods: Implant systems used for this study were 3i and Avana. Seven pail's of implant fixture, abutment and abutment screws for each system were selected and all fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. Each one was embedded beneath the platform of fixture. Surfaces of hexagonal structure before repeated closing and opening of abutment were observed using SEM and rotational freedom was measured by using toolmaker's microscope. Each abutment was secured to the implant future by each abutment screw with recommended torque value using a digital torque controller and was repeatedly delivered and removed by 20 times respectively. After experiment, evaluation for the change of hexagonal structures and measurement of rotational freedom were performed. Result : The results were as follows; 1. Wear of contact area between implant fixture and abutment was considerable in both 3i and Avana system. Scratches and defects were frequently observed at the line-angle of hexagonal structures of implant fixture and abutment. 2. In the SEM view of the external hexagon of implant fixture, the point-angle areas at the corner edge of hexagon were severely worn out in both systems. It was more notable in the case of 3i systems than in that of Avana systems. 3. In the SEM view of the internal hexagon of abutment, Gingi-Hue abutment of 3i systems showed severe wear in micro-stop contacts that were machined into the corners to prevent rotation and cemented abutment of Avana systems showed wear in both surface area adjacent to the corner mating with external hexagon of implant fixture. 4 The mean values of rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment were 0.48$\pm$0.04$^{\circ}$ in pre-tested 3i systems and 1.18$\pm$0.25$^{\circ}$ after test, and 1.80$\pm$0.04$^{\circ}$ in pre-tested Avana systems and 2.61$\pm$0.16$^{\circ}$ after test. 5. Changes of rotational freedom after test shouted statistical)y a significant increase in both 3i and Avana systems(P<0.05, paired t-test). 6. Statistically, there was no significant difference between amount of increase in the rotational freedom of 3i systems and amount of increase in that of Avana ones(P>0.05, unpaired t-test). Conclusion: Conclusively, it was considered that repeated delivery and remove of abutment by 20 times would not have influence on screw joint stability. However, it caused statistically the significant change of rotational freedom in tested systems. Therefore, it is suggested that repeated delivery and remove of abutment should be minimal as possible as it could be and be done carefully Additionally, it is suggested that the means or treatment to prevent the wear of mating components should be devised.

Effects of Coculture on Development of Biopsied Mouse Embryos as a Preclinical Model for Preimplantation Genetic Diagnosis of Human Embryos (생쥐 모델을 이용한 배아의 할구 생검법과 할구가 생검된 배아의 배양시 공배양 효과에 관한 연구: 인간에서의 착상 전 유전진단 기술 개발을 위한 동물실험 모델의 개발)

  • Kim, S.H.;Ryu, B.Y.;Jee, B.C.;Choi, S.M.;Kim, H.S.;Pang, M.G.;Oh, S.K.;Suh, C.S.;Choi, Y.M.;Kim, J.G.;Moon, S.Y.;Lee, J.Y.;Chae, H.D.;Kim, C.H.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.26 no.1
    • /
    • pp.9-20
    • /
    • 1999
  • The genetic defects in human gametes and embryos can cause adverse effects on overall reproductive events. Biopsy of embryos for preimplantation genetic diagnosis (PGD) offers a new possibility of having children free of the genetic disease. In addition, advanced embryo culture method may enhance the effectiveness of embryo biopsy for the practical application of PGD. This experimental study was undertaken to evaluate the effects of coculture on the development in vitro of biopsied mouse embryos as a preclinical model for PGD of human embryos. Embryos were obtained after in vitro fertilization (IVF) from F1 hybrid mice (C57BLfemale/CBAmale). Using micromanipulation, 1, 2, 3 or 4 blastomeres of 8-cell stage embryos were aspirated through a hole made in the zona pellucida by zona drilling (ZD) with acidic Tyrode's solution (ATS). After biopsy of blastomeres, embryos were cultured in vitro for 110 hours in Ham's F-10 supplemented with 0.4% BSA or cocultured on the monolayer of Vero cells in the same medium. The frequence of blastocyst formation were recorded, and the embryos beyond blastocyst stage were stained with 10% Giemsa to count the total number of nuclei in each embryo. There was no significant difference in the blastocyst formation between the zona intact control group and the zona drilling (ZD) only, or biopsied groups. The hatching rate of all the treatment groups except 4/8 group was significantly higher than that of control group. In all the treatment groups, there was a significant reduction in the mean cell number of embryos beyond blastocyst stage ($50.2{\pm}14.0$ in control group vs. $41.2{\pm}7.9$ in ZD, $39.3{\pm}8.8$ in 7/8, $29.7{\pm}6.4$ in 6/8, $25.1{\pm}5.7$ in 5/8, and $22.1{\pm}4.3$ in 4/8 groups, p<0.05). When the same treatments were followed by coculture with Vero cells, a similar pattern was seen in the blastocyst formation and the hatching rate. However, in all the treatment groups, there was a significant increase in the mean cell number of embryos beyond blastocyst stage with coculture, compared with the parallel groups without coculture. In the cleavage rate of biopsied blastomeres cultured for 110 hours after IVF, there was no significant difference between coculture and non-coculture groups (87.2% vs. 78.7%). However, the mean cell number of embryos developed from the biopsied blastomeres was significantly higher in coculture group ($11.5{\pm}4.7\;vs.\;5.9{\pm}1.9$, p<0.05). In conclusion, biopsy of mouse embryos after ZD with ATS is a safe and highly efficient method for PGD, and coculture with Vero cells showed a positive effect on the development in vitro of biopsied mouse embryos and blastomeres as a preclinical model for PGD of human embryos.

  • PDF