• Title/Summary/Keyword: caudal

Search Result 847, Processing Time 0.027 seconds

Regulation of Matrix Metalloproteinase-1 Expression by the Homeodomain Transcription Factor Caudal in Drosophila Intestine (초파리 장조직에서 Caudal 전사조절인자에 의한 matrix metalloproteinase-1 발현 조절)

  • Lee, Shin-Hae;Hwang, Mi-Sun;Choi, Yoon-Jeong;Kim, Young-Shin;Yoo, Mi-Ae
    • Journal of Life Science
    • /
    • v.22 no.12
    • /
    • pp.1600-1607
    • /
    • 2012
  • The matrix metalloproteinase (MMP) family plays essential roles in physiological processes such as embryonic development, angiogenesis, wound healing, and tissue homeostasis as a consequence of MMPr capacity for breaking down many types of extracellular matrix proteins. Imbalanced regulation of MMP expression can also lead to pathological conditions such as tumor progression. We recently reported that the Drosophila Mmp1 gene is highly expressed in the digestive tract and is required for the maintenance of intestinal homeostasis such as by restriction of uncontrolled intestinal stem cell proliferation. However, the regulatory mechanisms of MMP gene expression in the intestine remain unclear. In this study, we determined that the expression of Mmp1 is regulated by the homeodomain transcription factor Caudal. Experiments using the targeted expression of Caudal under the regulation of Gal4-UAS system indicated that endogenous Caudal is required for the Mmp1 gene expression in the adult Drosophila intestine and that exogenous Caudal induces Mmp1 expression. Transient transfection experiments indicated that Caudal can activate the promoter activity of Mmp1 and that several putative Caudal binding sites in the 5'-flanking region of the Mmp1 gene may be critical to the upregulation by Caudal. Our data suggest that Mmp1 is one of the target genes of Caudal in physiological normal condition and in tumorigenesis.

Effect of Artificial Caudal Fin on Performance of a Biomimetic Fish Robot Actuated by Piezoelectric Actuators (인조 꼬리지느러미가 압전작동기 구동형 생체모사 물고기 로봇의 성능에 미치는 영향)

  • Heo, Seok;Park, Hoon-Cheol;Tedy, Wiguna;Goo, Nam-Seo
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.429-434
    • /
    • 2007
  • This paper presents an experimental and parametric study of a biomimetic fish robot actuated by the Lightweight Piezo-composite Actuator(LIPCA). The biomimetic aspects in this work are the oscillating tail beat motion and shape of caudal fin. Caudal fins that resemble fins of BCF(Body and Caudal fin) mode fish were made in order to perform parametric study concerning the effect of caudal fin characteristics on thrust production at an operating frequency range. The observed caudal fin characteristics are the shape, area, and aspect ratio. It was found that a high aspect ratio caudal fin contributes to high swimming speed. The fish robot was propelled by artificial caudal fins shaped after thunniform-fish and mackerel caudal fins, which have relatively high aspect ratio, produced swimming speed as high as 2.364 cm/s and 2.519 cm/s, respectively, for 300 Vpp input voltage excited at 0.9 Hz. Thrust performance of the biomimetic fish robot was examined by Strouhal number, Froude number, Reynolds number, and Net forward force.

  • PDF

A Comparison of Two Techniques for Ultrasound-guided Caudal Injection: The Influence of the Depth of the Inserted Needle on Caudal Block

  • Doo, A Ram;Kim, Jin Wan;Lee, Ji Hye;Han, Young Jin;Son, Ji Seon
    • The Korean Journal of Pain
    • /
    • v.28 no.2
    • /
    • pp.122-128
    • /
    • 2015
  • Background: Caudal epidural injections have been commonly performed in patients with low back pain and radiculopathy. Although caudal injection has generally been accepted as a safe procedure, serious complications such as inadvertent intravascular injection and dural puncture can occur. The present prospective study was designed to investigate the influence of the depth of the inserted needle on the success rate of caudal epidural blocks. Methods: A total of 49 adults scheduled to receive caudal epidural injections were randomly divided into 2 groups: Group 1 to receive the caudal injection through a conventional method, i.e., caudal injection after advancement of the needle 1 cm into the sacral canal (n = 25), and Group 2 to receive the injection through a new method, i.e., injection right after penetrating the sacrococcygeal ligament (n = 24). Ultrasound was used to identify the sacral hiatus and to achieve accurate needle placement according to the allocated groups. Contrast dyed fluoroscopy was obtained to evaluate the epidural spread of injected materials and to monitor the possible complications. Results: The success rates of the caudal injections were 68.0% in Group 1 and 95.8% in Group 2 (P = 0.023). The incidences of intravascular injections were 24.0% in Group 1 and 0% in Group 2 (P = 0.022). No intrathecal injection was found in either of the two groups. Conclusions: The new caudal epidural injection technique tested in this study is a reliable alternative, with a higher success rate and lower risk of accidental intravascular injection than the conventional technique.

The Depth and Angle during Caudal Epidural Approach in Adult (성인에서 미추부 경막외강의 깊이와 각도)

  • Jo, Dae-Hyun;Kim, Myoung-Hee;Choy, Yoon-Keun
    • The Korean Journal of Pain
    • /
    • v.14 no.2
    • /
    • pp.207-210
    • /
    • 2001
  • Backgroud: Caudal blocks have been used for pain management in outpatient clinics. It is important to estimate the proper depth and angle in order to increase the success rate of the procedure. Methods: Data was collected from 60 patients who visited our pain clinic. We measured the depth of the needle's penetration and the angle of the needle at the insertion point when a caudal approach was confirmed by air flow method. We recorded age, sex, body weight and height, and calculated the ponderal index. Results: The depth from the skin to the caudal epidural space was a mean 2-4 cm ($3{\pm}0.4\;cm$). The angle at the needle insertion point was a mean 15-50 degree ($34.9{\pm}6.8$ degree). Conclusions: If we use the mean depth and angle as a guide, complications during the caudal epidural procedure can be avoided.

  • PDF

Improving the Performance of a Robotic Dolphin with a Compliant Caudal Fin (꼬리 지느러미의 유연성을 이용한 로봇 돌고래의 성능 향상)

  • Park, Yong-Jai;Cho, Kyu-Jin
    • The Journal of Korea Robotics Society
    • /
    • v.9 no.4
    • /
    • pp.225-231
    • /
    • 2014
  • Fish generates thrust with a compliant fin which is known to increase the efficiency. In this paper, the performance of a robotic dolphin, the velocity and the stability, was improved using an optimal compliant caudal fin under certain oscillating frequency. Optimal compliance of the caudal fin exists that maximizes the thrust at a certain oscillating frequency. Four different compliant fins were used to find the optimal compliance of the caudal fin at a certain frequency using the half-pi phase delay condition. The swimming results show that the optimal compliant fin increases the velocity of the robotic fish. The compliance of the caudal fin was also shown to improve the stability of the robotic fish. A reactive motion at the head of the robotic dolphin causes fluctuation of the caudal fin. This phenomenon increases with the oscillating frequency. However, compliant fin reduced this fluctuation and increased the stability.

Experimental Parameter Identification and Performance Analysis of a Fish Robot with Ostraciiform Swimming Mode using Rigid Caudal Fins (고체형 꼬리 지느러미로 오스트라키폼 유영을 하는 물고기 로봇의 패러미터 식별 및 성능 분석)

  • Chan, Wai Leung;Lee, Gi-Gun;Kim, Byung-Ha;Choi, Jung-Min;Kang, Tae-Sam
    • The Journal of Korea Robotics Society
    • /
    • v.5 no.3
    • /
    • pp.197-208
    • /
    • 2010
  • The ostraciiform swimming mode allows the simplest mechanical design and control for underwater vehicle swimming. Propulsion is achieved via the flapping of caudal fin without the body undulatory motion. In this research, the propulsion of underwater vehicles by ostraciiform swimming mode is explored experimentally using an ostraciiform fish robot and some rigid caudal fins. The effects of caudal fin flapping frequency and amplitude on the cruising performance are studied in particular. A theoretical model of propulsion using rigid caudal fin is proposed and identified with the experimental data. An experimental method to obtain the drag coefficient and the added mass of the fish robot is also proposed.

Accelerated L5-S1 Segment Degeneration after Spinal Fusion on and above L4-5 : Minimum 4-Year Follow-Up Results

  • Park, Jeong-Yoon;Chin, Dong-Kyu;Cho, Yong-Eun
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.2
    • /
    • pp.81-84
    • /
    • 2009
  • Objective : Many biomechanical and clinical studies on adjacent segment degeneration (ASD) have addressed cranial segment. No study has been conducted on caudal segment degeneration after upper segment multiple lumbar fusions. This is a retrospective investigation of the L5-S1 segment after spinal fusion at and above L4-5, which was undertaken to analyze the rate of caudal ASD at L5-S1 after spinal fusion on and above L4-5 and to determine that factors that might have influenced it. Methods : The authors included 67 patients with L4-5, L3-5, or L2-5 posterior fusions. Among these patients, 28 underwent L4-5 fusion, 23 L3-5, and 16 L2-5 fusions. Pre- and postoperative radiographs were analyzed to assess degenerative changes at L5-S1. Also, clinical results after fusion surgery were analyzed. Results : Among the 67 patients, 3 had pseudoarthrosis, and 35 had no evidence of ASD, cranially and caudally. Thirteen patients (19.4%) showed caudal ASD, 23 (34.3%) cranial ASD, and 4 (6.0%) both cranial and caudal ASD. Correlation analysis for caudal ASD at L5-S1 showed that pre-existing L5-S1 degeneration was most strongly correlated. In addition, numbers of fusion segments and age were also found to be correlated. Clinical outcome was not correlated with caudal ASD at L5-S1. Conclusion : If caudal and cranial ASD are considered, the overall occurrence rate of ASD increases to 50%. The incidence rate of caudal ASD at L5-S1 was significantly lower than that of cranial ASD. Furthermore, the occurrence of caudal ASD was found to be significantly correlated with pre-existing disc degeneration.

Disorders of Secondary Neurulation : Mainly Focused on Pathoembryogenesis

  • Yang, Jeyul;Lee, Ji Yeoun;Kim, Kyung Hyun;Wang, Kyu-Chang
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.3
    • /
    • pp.386-405
    • /
    • 2021
  • Recent advancements in basic research on the process of secondary neurulation and increased clinical experience with caudal spinal anomalies with associated abnormalities in the surrounding and distal structures shed light on further understanding of the pathoembryogenesis of the lesions and led to the new classification of these dysraphic entities. We summarized the changing concepts of lesions developed from the disordered secondary neurulation shown during the last decade. In addition, we suggested our new pathoembryogenetic explanations for a few entities based on the literature and the data from our previous animal research. Disordered secondary neurulation at each phase of development may cause corresponding lesions, such as failed junction with the primary neural tube (junctional neural tube defect and segmental spinal dysgenesis), dysgenesis or duplication of the caudal cell mass associated with disturbed activity of caudal mesenchymal tissue (caudal agenesis and caudal duplication syndrome), failed ingression of the primitive streak to the caudal cell mass (myelomeningocele), focal limited dorsal neuro-cutaneous nondisjunction (limited dorsal myeloschisis and congenital dermal sinus), neuro-mesenchymal adhesion (lumbosacral lipomatous malformation), and regression failure spectrum of the medullary cord (thickened filum and filar cyst, low-lying conus, retained medullary cord, terminal myelocele and terminal myelocystocele). It seems that almost every anomalous entity of the primary neural tube may occur in the area of secondary neurulation. Furthermore, the close association with the activity of caudal mesenchymal tissue in secondary neurulation involves a wider range of surrounding structures than in primary neurulation. Although the majority of the data are from animals, not from humans and many theories are still conjectural, these changing concepts of normal and disordered secondary neurulation will provoke further advancements in our management strategies as well as in the pathoembryogenetic understanding of anomalous lesions in this area.

Analysis on the Propulsion Force of an Ostraciiform Fish Robot with Elastically Jointed Double Caudal Fins and Effect of Joint Position on the Propulsion Force (탄성 조인트로 연결된 이중 꼬리 지느러미 오스트라키폼 물고기 로봇의 추진력 해석 및 조인트 위치가 추력에 미치는 영향)

  • Kang, I-Saac
    • The Journal of Korea Robotics Society
    • /
    • v.6 no.3
    • /
    • pp.274-283
    • /
    • 2011
  • A simplified linearized dynamic equation for the propulsion force generation of an Ostraciiform fish robot with elastically jointed double caudal fins is derived in this paper. The caudal fin is divided into two segments and connected using an elastic joint. The second part of the caudal fin is actuated passively via the elastic joint connection by the actuation of the first part of it. It is demonstrated that the derived equation can be utilized for the design of effective caudal fins because the equation is given as an explicit form with several physical parameters. A simple Ostraciiform fish robot was designed and fabricated using a microprocessor, a servo motor, and acrylic plastics. Through the experiment with the fish robot, it is demonstrated that the propulsion force generated in the experiment matches well with the proposed equation, and the propulsion speed can be greatly improved using the elastically jointed double fins, improving the average speed more than 80%. Through numerical simulation and frequency domain analysis of the derived dynamic equations, it is concluded that the main reason of the performance improvement is resonance between two parts of the caudal fins.

Caudal Agenesis : Understanding the Base of the Wide Clinical Spectrum

  • Lee, Ji Yeoun;Shim, Youngbo;Wang, Kyu-Chang
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.3
    • /
    • pp.380-385
    • /
    • 2021
  • Caudal agenesis refers to the congenital malformation with the essential feature of the agenesis of the sacrococcygeal bone. It is associated with various types of spinal cord anomaly as well as with complex anomalies of genitourinary or gastrointestinal system. The wide spectrum of the disease can be attributed to its pathoembryological origin, the secondary neurulation. This review presents the definition, etiology, classification, and clinical features of the disease.