• 제목/요약/키워드: cathode ray tube

검색결과 101건 처리시간 0.025초

인듐안티모나이드 포토 센서를 이용한 CRT 섀도우 마스크의 비접촉 온도 측정에 관한 연구 (A study on the non-contact measurement for the temperature of shadow mask of Cathode Ray Tube using InSb photo sensor)

  • 강대진;박정우;송창섭
    • 한국정밀공학회지
    • /
    • 제14권3호
    • /
    • pp.15-20
    • /
    • 1997
  • This paper presents the experimental study of the non-contact temperature measurement for the shadow mask of cathode ray tube using InSb sensor. At present, High resolution of CRT(Cathode Ray Tube) is needed broadly; therefore, the measurement of temperature distribution of shadow mask in CRT during operation is important to analyze the thermal deformation of shadow mask. Most of the studies could not measure the temperature distribution of shadow mask precisely. We studied the temperature dis- tribution of shadow mask using InSb photo sensor for 17" cathode ray tube (CRT). Experiments using ther- mocouple are performed to validate the results of non-contact measurement. The results agree well with those results of non-contact method using InSb sensor.nsor.

  • PDF

X-선관 각도 변경에 따른 Anode Heel Effect (The Anode Heel Effect caused by changing the Angle of X-Ray Tube)

  • 신성규;이효영
    • 한국방사선학회논문지
    • /
    • 제10권6호
    • /
    • pp.435-442
    • /
    • 2016
  • 본 연구는 X-선관 각도 변경에 따른 경사효과(Anode Heel Effect)의 변화를 알아보고자 실시하였다. 실험조건은 70 kV, 30 mAs, 초점-검출기간의 거리 100 cm, 조사야는 $35{\times}43cm^2$, 측정점은 조사야의 정중앙점에서 좌우 3.5 cm 간격으로 나누어 양극쪽으로 A1, A2, A3, A4, A5, A6 점을 설정하고 음극쪽으로 C1, C2, C3, C4, C5, C6 점으로 설정하였다. X-선관을 수직으로 하여 측정점인 A6에서 C6까지 각각 입사표면선량을 측정하였다. 다음에 X-선관을 양극쪽으로 15도 30도로 변경 하면서 각각 측정하고 같은 방법으로 음극쪽으로 15도 30도로 변화시켜 측정하였다. 결과로 X-선관이 수직인 경우 A5보다 C5점이 3배정도 입사표면선량이 높게 나타나 수직 촬영 시 방사선감수성이 높은 장기가 위치해 있는 쪽으로 양극을 위치시키면 피폭을 줄일 수 있었다. X-선관의 각도를 주고 촬영할 경우에는 음극측으로 각도를 주는 것이 양극과 음극측의 입사표면선량 차이를 줄일 수 있으며 상, 하 두께 차이가 있는 부위를 촬영할 경우에는 음극측이 두꺼운 부위를 향하게 각도를 주는 것이 입사표면선량의 차이를 줄여 좀 더 균일한 영상을 만들 수 있었다.

탄소 나노 튜브의 음극선관용 전자총 응용 (Application of Carbon Naotube to the Electron Gun of the Cathode Ray Tube)

  • 주병권;장윤택;이윤희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권3호
    • /
    • pp.121-124
    • /
    • 2002
  • CNTs(Carbon Nano Tube) were employed as an electron source in electron-gun of CRT(Cathode-Ray Tube). The CNTs were grown on the Si substrates and the electron gun by LP-CVD(Low Pressure-Chemical Vapor Deposition). Their physical and field emission property satisfied the requirements of the electron gun of CRT. The fabricated electron gun was inserted into 19 inch-sifted CRT and its operating properly was evaluated for practical usage.

전자기 유한요소법 전자빔 시뮬레이션을 이용한 정전기장 제거용 연한 X-선관 설계 특성 연구 (Design of Soft X-ray Tube and Simulation of Electron Beam by Using an Electromagnetic Finite Element Method for Elimination of Static Electric Field)

  • 박태영;이상석;박래준
    • 한국자기학회지
    • /
    • 제24권2호
    • /
    • pp.66-69
    • /
    • 2014
  • 유한요소법으로 분할 표시한 연한 X-선 퍼짐관을 설계하였다. 연한 X-선관의 모양설계 및 구체적인 좌표를 설정하고 전자빔 궤적을 OPERA-3D SW 프로그램을 이용하여 시뮬레이션하였다. 음극과 양극인 텅스텐 필라멘트와 타겟에 인가한 전압, 온도, 열전자 일함수 등을 고정하였다. 필라멘트 십자형 모양을 구비한 퍼짐관의 구조에 따른 전자빔의 분포와 초점변화를 분석하여 반도체 공정상의 정전기장 제거용 연한 X-선 퍼짐관 설계를 최적화하였다.

Irradiation of Intense Characteristic X-rays from Weakly Ionized Linear Plasma

  • Sato, Eiichi;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Takayama, Kazuyoshi;Ido, Hideaki
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.396-399
    • /
    • 2002
  • Intense quasi-monochromatic x-ray irradiation from the linear plasma target is described. The plasma x-ray generator employs a high-voltage power supply, a low-impedance coaxial transmission line, a high-voltage condenser with a capacity of about 200 nF, a turbo-molecular pump, a thyristor pulse generator as a trigger device, and a flash x-ray tube. The high-voltage main condenser is charged up to 55 kV by the power supply, and the electric charges in the condenser are discharged to the tube after triggering the cathode electrode. The x-ray tube is of a demountable triode that is connected to the turbo molecular pump with a pressure of approximately 1 mPa. As electron flows from the cathode electrode are roughly converged to the molybdenum target by the electric field in the tube, the weakly ionized plasma, which consists of metal ions and electrons, forms by the target evaporating. In the present work, the peak tube voltage was almost equal to the initial charging voltage of the main condenser, and the peak current was about 20 kA with a charging voltage of 55 kV. When the charging voltage was increased, the linear plasma x-ray source grew, and the characteristic x-ray intensities of K-series lines increased. The quite sharp lines such as hard x-ray lasers were clearly observed. The quasi-monochromatic radiography was performed by a new film-less computed radiography system.

  • PDF

평면 음극선관의 재생률 향상을 위한 유리재료의 열적 특성에 관한 연구 (A Study on the Thermal Properties of Glass for Effective Salvage Process of Flat Cathode-ray Tube)

  • 박상후;이부윤;김원진;허보석
    • 대한기계학회논문집A
    • /
    • 제25권12호
    • /
    • pp.1988-1994
    • /
    • 2001
  • The CRT(Cathode-ray Tube) of salvage is a process of separating the panel and funnel to recycle a cathode-ray tube. In this paper, the thermal properties of glass for CRT were studied to improve its recycling ratio. In the salvage process, several patterns of breakage, as called 'comer pull', were easily generated on the sealing surface of panel or funnel glass due to the residual tensile stress, which had correlations with some parameters of the manufacturing process of CRT and the initial material properties of glass. Finite element analyses and experimental approaches on the flit sealing process were carried out to obtain the major characteristic of glass related to the residual stress. From this study, it was identified that the thermal expansion coefficient of glass had much influence on the residual stress of panel glass after frit sealing process. Therefore, the optimal conditions of thermal properties for CRT glass were proposed to achieve an effective salvage process. By using these optimal conditions, the size of comer pull on the panel and funnel glass was reduced to 10% level compared with the original size, and the recycling ratio of CRT was increased in the salvage process.

Structural Design of a Cathode-ray Tube (CRT) to Improve its Mechanical Shockproof Character

  • Park, Sang-Hu;Kim, Won-Jin
    • Journal of Mechanical Science and Technology
    • /
    • 제20권9호
    • /
    • pp.1361-1370
    • /
    • 2006
  • An electronic beam mis-landing phenomenon on the RGB (red/green/blue) -fluorescent surface has been considered as one of serious problems to be solved in cathode-ray tube (CRT), which is generally caused by mechanical shock and vibration. In this work, structural design concepts on the major parts of the CRT, such as a frame, a shadow mask, and a spring, are studied to improve the mechanical shockproof character of a CRT by FEM-analyses and experimental approaches ; a frame is newly designed to have strength employing the double-corner-beads which reduces considerably the distortion of the frame and the shadow mask : the edge-bead of a shadow-mask is redesigned to maintain the wide curved surface of a shadow-mask after mechanical shock : finally, a spring supporting the frame and the shadow-mask is designed to have enough flexibility along drop-direction. As an example, a conventional type of a 15inch CRT was utilized to demonstrate the feasibility and usefulness of this work. Overall, some favorable information on the structural design of the CRT is achieved, and the mechanical shockproof character of a 15-inch CRT is improved in the degree of 3G $(1G=9.81m/s^2)$ as an average-value.

유한요소법을 이용한 X-선관 양극각도에 의존하는 전자빔 초점 특성 연구 (Property of Focal Spot of Electron Beam Depending on the Anode Angle of X-ray Tube Using a Finite Element Method)

  • 박태영;노영일;이상석;박래준;김기선
    • 한국자기학회지
    • /
    • 제25권2호
    • /
    • pp.52-57
    • /
    • 2015
  • 텅스텐 타겟인 양극의 각도에 의존하는 X-선관 집속관의 전자빔 초점 크기를 오페라-3차원/스칼라(OPERA-3D/SCALAR) 프로그램을 이용하여 구하였다. 시뮬레이션 분석은 X-선관을 음극과 양극 그리고 4영역을 나누어 유한요소법을 적용하였다. X-선 집속관의 필라멘트로부터 방출되는 열전자 궤적은 전자밀도 분포함수에 따라 양극에 도달할 때 실초점으로 집속되고 양극에 부딪쳐서 유효 초점 크기로 X-선을 발생하게 된다. 전자빔 실초점 크기는 X-선 집속관 모양을 결정짓는 폭, 길이, 높이를 조절하여 줄일 수 있었고, 양극각도의 크기에 따라 미세하게 변하였다. 양극각도가 $10^{\circ}{\sim}17^{\circ}$에서는 전자빔 실초점 크기를 $70{\mu}m$ 이내로 유지하였고, 가장 최소 초점크기는 $15^{\circ}$에서 실초점 크기가 $40{\mu}m$로 나타났다. 최적화된 X-선 집속관의 변수들로 시뮬레이션하는 열전자의 방출 궤적을 분석하여 얻은 마이크로 크기인 실초점을 활용하는 새로운 의료 영상진단기기 개발이 가능할 것으로 보여진다.

FTM 튜브의 판넬과 마스크의 일치방법 개발 (Development of Registration Method of Panel and Mask for FTM Tube)

  • 윤종순;정종윤
    • 산업공학
    • /
    • 제11권2호
    • /
    • pp.107-117
    • /
    • 1998
  • This paper presents a useful method of registration in manufacturing of shadow color mask for cathode ray tubes of the FTM (Flat Tension Mask) type, wherein the shadow mask and front panel are interchangeable when mask-panels are assembled, which is called ICM system. Theoretical analysis and alignment process are presented. The pattern of mask aperture is registered with a screen pattern of corresponding geometry of the panel in flat tension mask tube. Registration accuracy of panel and mask affects the purity of color cathode ray tube concerned with mislanding. It tries to minimize the misregistration caused by variances, which are mechanical error, mask stretching position error, restrictive number of fiducial point, etc.

  • PDF