• 제목/요약/키워드: cascade impactor

검색결과 104건 처리시간 0.027초

서울시 지하상가 공기중 다환방향족 탄화수소의 농도조사에 관한 연구 (Measurements of Polycyclic Aromatic Hydrocarbons(PAHs) Concentration in Air of the Seoul Underground Shopping Stores)

  • 전준민;김윤신
    • 한국대기환경학회지
    • /
    • 제9권1호
    • /
    • pp.81-92
    • /
    • 1993
  • A purpose of this study was carried out to investigate the concentrations of four elements of PAHs(Polycyclic Aromatic Hydrocarbons) in suspended particulate matters of underground shopping stores in Seoul city. The particulate matters were collected at five underground shopping stores(Yongdungpo, Myongdong, Ulchiro, Express Terminal, Chamshil) in the Seoul area during February-October, 1992. Samples were collected using cascade impactor of low volumn air sampler and were analysed using High Performance Liquid Chromatography(HPLC) with fluorescence detector. Calibration on HPLC analyse is nearly accord with retention time between the standard solution and the samples. Analysed results obtained favorable analysing recovery rate of 97.3% and coefficient of variation of 1.60%. Mean concentrations of suspended particulate matters in five underground shopping stores wre 216.3 g/$m^3$ and observed higher at fine particles(117.2 g/$m^3$) which is respirable particulates than coarse particles(99.2 g/$m^3$). Concentrations of four species PAH were determined with anthracene of 16.8ng/$m^3$, fluoranthene of 72.3ng/$m^3$, benzo(a)pyrene of 0.54ng/$m^3$, and benzo(k)fluoranthene of 0.29ng/$m^3$, respectively. Fluoranthene levels were significantly higher than those levels in other components. PAHs concen-tration at shopping areas showed 21.3ng/$m^3$ in Yongdungpo, 35.1ng/$m^3$ in Myongdong, 23.4ng/$m^3$ in Ulchiro, 11.1ng/$m^3$ in Express Terminal, and 21.4ng/$m^3$ in Chamshil, respectively. Particularly, benzo(a)pyrene and benzo(k)-fluoranthene were detected over 83 percentage in fine particles, while fluoranthene wre highly detected in coarse particles. Also, higher concentrations of benzo(a)pyrene, benzo(k)fluoranthene were found in winter while levels of anthracene and fluoranthene were found higher in summer than other seasons.

  • PDF

다중이용시설 내부에 분포하는 부유 진균의 입경별 농도 특성 (Size Distribution and Concentration of Airborne Fungi in the Public Facilities)

  • 박재범;김기연;장규엽;김치년;이경종
    • 한국환경보건학회지
    • /
    • 제32권1호
    • /
    • pp.36-45
    • /
    • 2006
  • The aim of this study is to examine size-based concentration and genera of airborne fungi distributed in public facilities such as hospital, kindergarten, day-care center and postpartum nurse center and to provide fundamental data in order to prevent respiratory diseases caused by exposure to airborne fungi. Culturable total and respirable concentrations of airborne fungi averaged to $382\;cfu/m^3\;and\;292\;cfu/m^3$ in hospital, $536\;cfu/m^3\;and\;347\;cfu/m^3$ in kindergarten, $334\;cfu/m^3\;and\;266\;cfu/m^3$ in day-care center, and $371\;cfu/m^3\;and\;289\;cfu/m^3$ in postpartum nurse center, respectively. The ratio of respirable to total concentration of airborne fungi in the investigated public facilities was ranged from $55\%\;to\;70\%$ but there was no significant difference among them (p>0.05). The mean I/O ratio of culturable total and respirable concentrations were 0.56 and 0.64 in hospital, 0.72 and 0.91 in kindergarten, 0.33 and 0.45 in day-care center, and 0.63 and 0.73 in postpartum nurse center, respectively. Indoor concentration of airborne fungi did not correlated significantly with indoor temperature and relative humidity (p>0.05) but had a significant positive correlation with $CO_2$ concentration (p<0.01) and surrounding condition (p<0.05). Penicillium spp., Cladosporium spp., and Aspergillus spp. were estimated to over $95\%$ of total airborne fungi identified in the investigated public facilities.

서울시 일부 지역의 대기 중 부유 진균의 분포 특성 (Distribution Characteristics of Airborne Fungi in a Partial Area of Seoul City)

  • 김기연;김대근
    • 한국환경보건학회지
    • /
    • 제38권5호
    • /
    • pp.407-414
    • /
    • 2012
  • Objectives: This study was performed to assess based on field investigation the distribution characteristics of airborne fungi in an area of Seongdong-gu, Seoul. Methods: Three sites, a living area, forest and traffic site, were selected for evaluation of monthly level of outdoor airborne fungi. An on-site survey was executed between January 2009 and December 2009. During the experimental period, air sampling was performed every month in the afternoon (2:00 pm-5:00 pm) using a cascade impactor. Results: Outdoor airborne fungi measured in Seoul, Korea over one year showed a concentration range from 850CFU $m^{-3}$ to 15,200CFU $m^{-3}$. The mean respirable fraction of outdoor airborne fungi was 67% compared to total concentration. Regardless of measurement site, there was no significant concentration difference in outdoor airborne fungi between periods of yellow dust and non-yellow dust (p>0.05). There was no significant correlation relationship between outdoor airborne fungi and atmospheric factors such as temperature and relative humidity. The predominant genera of airborne fungi identified were Aspergillus, Cladosporium, Paecilomyces and Penicillium. Conclusion: Monthly levels of outdoor airborne fungi were highest in April and November and lowest in August. In seasonal concentration distribution, the autumn showed the highest level of outdoor airborne fungi, followed by spring, summer and winter. In regional concentration distribution, the highest level of outdoor airborne fungi was generally found in the forest, followed by the living area and traffic site.

호흡성분진중의 중금속 오염도에 관한 조사연구 (A Study of Heavy Metal Pollutants in the Respirable Dust in Seoul Area)

  • 임영욱;정용
    • 한국대기환경학회지
    • /
    • 제5권1호
    • /
    • pp.68-78
    • /
    • 1989
  • The heavy metal of suspended particulates with human health has long been studied in environmental interest concerned. This study was intended to identify harmful heavy metals of the ambient air borne dusts which were related with the respirable sizes in the aerodynamics. Two sampling sites were selected comparatively; one was in the Shinchon area, which is the commercial district with heavy traffic and the other site was in the Bulgwang area which is residential area. The supended particulates were sampled by high volume air sample with 6 cascade impactor stages. The heavy metals in terms of As, Cd, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Se, V and Zn were determined by stomic absorption spectrometry or inductively coupled plasma emission spectrometry. The samples weretaken bimothly for seven consecutive days from May 1987 to March 1988. The annual average concentration of the respirable suspended dust of which diameter is less than 10$\mum$ was 152.59 $\mug/m^3$ of the Shinchon air samples; the respirable dust was equivalent to approximately 85% of the total suspended particulates. The annual average concentration of the respirable suspended dust of the Bulgwang air samples was 112.56 $\mug/m^3$; that was approximately 86% of the total suspended particulates. The concentration of heavy metals was investigated in relation to the particle size. The concentration of Cr, Fe, Mn and V were tended to be much more in the coarse particles than in the fine particles. Cd and Pb in the fine particles were more than in the coarse particles. In the partial correlation coefficients; in the Shinchon area, high correlations among Fe, Se and Mn were determined; it is assumed that those sources would be originated from coal, gasolineand diesel. In Bulgwang area, would be high correlation among Fe, Se, Hg and Mn considered to be originated from coal, Bunker-C and heavy oil as well. From the above results, the hazardous heavy merals in air should be measured and controlled in originally their sources.

  • PDF

Evaluation of Endocrine Disrupting Chemicals-Complex Mixture in Diesel Exhaust Respirable Particulate Matter

  • Ryu, Byung-Tak;Jang, Hyoung-Seok;Kim, Yun-Hee;Kim, Soung-Ho;Lee, Do-Han;Han, Kyu-Tae;Oh, Seung-Min;Chung, Kyu-Hyuck
    • 한국환경독성학회:학술대회논문집
    • /
    • 한국환경독성학회 2003년도 춘계학술대회
    • /
    • pp.195-195
    • /
    • 2003
  • It is well known that diesel exhaust particulate matter contains mutagenic PAHs, such as benzo[${\alpha}$]pyrene, benz[${\alpha}$]anthracene, chrysene, etc. Therefore it is suspected that these chemicals act on estrogen receptor and reveal endocrine-disrupting effects. Recent attention has focused on causative chemicals of endocrine-disrupting effects. We examined the estrogenic activity of respirable diesel exhaust particulate matter derived from diesel powered vehicle. PM2.5 diesel exhaust of vehicle was collected using a high volume sampler equipped with a cascade impactor. Diesel exhaust samples were fractionated according to EPA methods. The presence of estrogenic and antiestrogenic chemicals in PM 2.5 diesel exhaust was determined using E-screen assay. To quantitatively assess the estrogenic and antiestrogenic activities in diesel exhaust particulate matter, estradiol equivalent concentration (bio-EEQ) was calculated by comparing the concentration response curve of the sample with those of the estrogen calibration curve. Weak estrogenic activities and strong antiestrogenic activities were detected in the crude extract and moderately polar fractions. Higher antiestrogenic potency was observed with higher EROD activities in aliphatic and aromatic compounds fraction. In conclusion, estrogenic/antiestrogenic-like activities were present in diesel exhaust particulate matter. However, the health consequences of this observation was unknown, the presence of these activities may contribute to and exacerbate adverse health effect evoked by diesel exhaust particulate matter.

  • PDF

Evaluation of Environmental Mutagens-Complex Mixture in Diesel Exhaust Respirable Particulate Matter

  • Kim, Soung-Ho;Ryu, Byung-Tak;Jang, Hyoung-Seok;Kim, Yun-Hee;Lee, Do-Han;Han, Kyu-Tae;Oh, Seung-Min;Chung, Kyu-Hyuck
    • 한국환경독성학회:학술대회논문집
    • /
    • 한국환경독성학회 2003년도 춘계학술대회
    • /
    • pp.194-194
    • /
    • 2003
  • The International Agency for Research on Cancer (IARC, 1989) has classified whole diesel exhaust as probably carcinogenic to humans. Diesel exhaust particulate matter (DPM) adsorbs different chemical substances including PAHs and nitroarenes. DPM is emphasized because it is a major component of diesel exhaust, it is suspected of contributing to a health hazard. Diesel exhaust is a complex mixture of carbon particles and associated organics and inorganics, and it is not known what fraction or combination of fractions cause the health effects [cancer effects, noncancer effects (respiratory tract irritation/inflammation and changes in lung function)] that have been observed with exposure to diesel exhaust. In order to identify which chemical classes are responsible for the majority of the observed biological activities, we performed a particular biological/chemical analysis. Respirable particulate matter (PM2.5: <2.5mm) was collected from diesel engine exhaust using a high-volume sampler equipped with a cascade impactor. Particulate oganic matter was extracted by the dichloromethane/sonication method and the crude extract was fractionated according to EPA recommended procedure into seven fractions by acid-base partitioning and silica gel column chromatography. We examined genotoxic potentials of diesel exhaust particulate matter using novel genotoxicity tests, which are rapid, simple and sensitive methods for assessing DNA-damage at the DNA and chromosomal level (comet assay, in vitro MN test and Ames test). Higher genotoxic potency was observed in non polar fractions and several PAHs were detected by GC-MS, such as 1,2,5,6 dibenzanthracene, chrysene, 1,2-benzanthracene, phenanthrene and fluoranthene.

  • PDF

X-선 형광분광법을 이용한 대기부유분진중 중금속의 농도분포에 관한 연구 (Studies on the Distribution of Heavy Metal Concentrations in Ambient Suspended Particulate Matters Using the X-ray Fluorescence Spectroscopy)

  • 이태정;김동술
    • 한국대기환경학회지
    • /
    • 제8권1호
    • /
    • pp.20-28
    • /
    • 1992
  • The x-ray fluorescence(XRF) is one of the most convenient and widely used techniques for analyzing trace elements in ambient particulate matters. The objects of the study were to estimate the optimum exposure time using the XRF, to investigate the distributions of heavy metal levels in particulate matters, and finally to study seasonal variation for the concentrations of total suspended particulate matters(TSP) and size fractionated particulate matters. The suspended particulate matters had been collected by a cascade impactor having 9 size fragnated stages for 3 years(Dec. 1988 to Nov. 1991) in Kyung Hee University-Suwon Campus. The particulate matters were then collected on each stage by membrane filters. The weight concentrations were determined by the XRF system. Thus, seasonal variations and relationship between concentration and particle size could be investigated. Resulting distribution was bimodal with the coarse and the fine particle groups minimum occurring around 2.1 to 3.3 $\mu$m as an aerodynamic diameter. To determine optimum exposure time of the XRF for various trace inorganic elements, membrane filters and the NIST standard filters were extensively studied. Using a statistical technique, optimum exposure time was estimated for each trace element and overall elements. The time was then determined as 20 seconds for the XRF system. The concentration of TSP was 123.9$\mum/m^3$ on an arithmatic average. The levels of each inorganic metal were Si 2420.0ng/$m^3$, Fe 977.1ng/$m^3$, and so on. The Pb. Zn, and Cu abounded in the fine mode group, while Ca, Fe, Si, Al, and K in the coarse group. Marked seasonal variation of TSP and metal concentrations was observed. The concentration of heavy metals in the fine mode was highest in winter : on the other hand, that in the coarse mode was highest in spring.

  • PDF

대기 부유분진중 다환방향족 탄화수오류의 계절적 입경농도 분포 변이 (Seasonal Variation of Size Distributions of Polycyclic Aromatic Hydrocarbons in Air Particulates)

  • 정용;박성은;황만식
    • 한국대기환경학회지
    • /
    • 제14권6호
    • /
    • pp.577-588
    • /
    • 1998
  • Polycyclic aromatic hydrocarbons (PAHs) are products of incomplete combustion and, in urban area atmosphere, are mainly traffic or heating in origin. Size-segregated aerosol samples were collected on the Eixth story of Shinchon on the Yonsei campus, using a high-volume cascade impactor, between August 1994 and September 1995. Ten PAHs were analyzed by GC/MSD. The size distribution of PAH-containing particulates followed approximately a log-normal relationship with the majority of PAH content associated with particles below 3.0mm. PAHs concentration in submicron particles increased during the winter months. The Mass Median Diameter (MMD) value of annual particulates in the heavy traffic area of Shinchon shows about 1.6 pm. The MMD values of air particulate in winter were the lowest values and similar to that in summer, while MMD values of seasonal PAHs were generally lower than 1.0 pm. Among the PAHs, MMD values of PAHs with the more than 5 benzen ring were averagely lower than those with 4 benzin rings. Especially MMD's of dibenzo (a, h) anthracene in winter was clearly lower than in summer. This reason may be caused by fuels used for heating. In this area, 50∼80% PAHs mass was particles smaller than 1.0mm aerodynamic diameter in size range, and the MMD values of PAHs lower than those of other country's area.

  • PDF

Submicron 부유분진의 화학적 조성 및 분포에 관한 연구 (Studies on the Chemical Compositions and Distributions of Ambient Sumicron Aerosols)

  • 황인조;김동술
    • 한국대기환경학회지
    • /
    • 제14권1호
    • /
    • pp.11-23
    • /
    • 1998
  • The purpose of this study was to survey chemical distribution of inorganic elements and ions in the submicron particles, to characterize qualitatively emitting sources by factor analysis, and finally to reveal existing patterns in terms of chemical compounds by a stepwise multiple regression analysis. Total of 141 samples were collected by a cascade impactor from 1989 to1996. Fifteen chemical species (Al, Ba, Cd, K, Pb, Cu, Fe, Ni, $Cl^-, NO_3^-, SO_4^{2-}, K^+, Mg^{2+}, Ca^{2+}, and Na^+$) were characterized by AAS and IC. The study showed that average seasonal levels of submicron particulate matters $(d_p<0.43 \mum)$ were 18.7 $\mug/m^3$ in spring, 15.5 $\mug/m^3$ in summer, 15.7 $\mug/m^3$ in fall, and 24.5 $\mug/m^3$ in winter, respectively. All of the anion concentrations in the particle were highest in the winter season. By applying a factor analysis, 5 source patterns were qualitatively obtained, such as sulfate related source, nitrate related source, oil burning source, calcium related source, and coal combustion source. Finally, when applying a stepwise multiple regression analysis, the results clearly showed that $Na^+ and Ca^{2+}, K^+ and Ca^{2+}, NO_3^-$ and relative humidity, $Cl^-$ and ambient temperature, $Ca^{2+} and Cl^-, Mg^{2+} and SO_4^{2-}, Na^+ and NO_3^-, and Ca^{2+} and NO_3^-$, respectively, are negatively contributed to each other. As a result of those statistical analysis, we could suggest that some chemical compounds in the submicron particles such as$NaNO_3, MgSO_4, Ca(NO_3)_2, and CaCl_2$ may not exist on the filter as final composing products; however, other compounds may possibly exist in the form of $Mg(NO_3)_2, CaSO_4, Na_2SO_4, K_2SO_4, MgCl_2, NaCl, and KCl$. Thus, it must be necessary to identify differences between the results of above statistical analysis and of the real world by laboratory experiments.

  • PDF

공기 중 바이러스 포집 장비의 효율성 평가 (Assessment of Instrument Efficiency in Detecting Airborne Virus)

  • 하태환;이인복;권경석;이성복;송상현;;윤순식
    • 한국농공학회논문집
    • /
    • 제54권1호
    • /
    • pp.63-72
    • /
    • 2012
  • In livestock industry, damage caused by the epidemic diseases such as Foot-and-Mouth Disease (FMD), Highly-Pathogenic-Avian-Influenza (HPAI) and Porcine-Reproductive-and-Respiratory-Syndrome (PRRS) was very serious. The financial loss incurred from FMD alone which occurred on Nov. 2011 in Korea was estimated at 3 billion won, 23 % of annual livestock industry production. The livestock industry in Korea has greater risk of disease infection because of high density production, etc. Investigating the spread of livestock diseases should consider both direct and indirect contact as well as other various factors including airborne. Airborne infection of livestock disease was first hypothesised in the early 1900s, however, field experimental studies are still limited. Furthermore, no protocol is available in detecting airborne viruses in the field. In this study, effective virus samplers were investigated by comparative analysis of the type of samplers used detect to airborne virus. Laboratory experiments were conducted to compare virus samplers such as Bio-sampler, Dust-sampler, Compact-Cascade-Impactor (CCI) and Microflow in detecting PRRSV. Samples were analyzed by Reverse-Transcription PCR to assess the efficiency of the instrument in detecting the airborne virus. First, samples were classified into five levels according to light intensity of gel images and then the classified results were normalized. In every case, Bio-sampler and Dust-sampler were comparable with each other and have shown to be more effective than CCI and Microflow samplers.