• Title/Summary/Keyword: cartridge heater

Search Result 24, Processing Time 0.027 seconds

Thermal Conductivity Analysis of Heating Rollers for Cable Low Dust POD Production (저분진 케이블 POD 생산을 위한 히팅 롤러의 열전도 분석)

  • Song, Young-Jun;Lim, Jong-Hak;Byun, Young-il;Hong, Seong-Min;Jeong, Young-Hwan;Park, Jang-Yong;Song, Chul Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.1
    • /
    • pp.28-33
    • /
    • 2022
  • The heating roller of an actual pulse output device (POD) production facility is composed of a steel roller and a rubber roller. The time to reach a specific temperature and the temperature distribution on the roller surface were analyzed and compared according to the change in the number of cartridge heaters inside the heating roller. In this analysis, a steady-state thermal analysis of a steel roller was performed for the cases of a 5-cartridge heater and 9-cartridge heater. Finite element analysis was applied with reference to the surface temperature data of the heating roller during operation and the calorific value of the cartridge heater. Using the 9-cartridge heater, faster target temperature achievement and more uniform temperature distribution were confirmed than for the 5-cartridge heater.

Simultaneous Temperature and Velocity Fields Measurements near the Boiling Point

  • Doh, Deog-Hee;Hwang, Tae-Gyu;Koo, Bon-Young;Kim, Seok-Ro
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.531-542
    • /
    • 2007
  • Simultaneous measurement technique for temperature and velocity fields near a heated solid body has been constructed. The measurement system consists of a 3-late CCD color camera, a color image grabber, a 1ighting system, a host computer and a software for the whole quantification process. Thermo Chromic Liquid Crystals (TCLC) was used as temperature sensors. A neural network was used to get a calibration curve between the temperature and the color change of the TCLC in order to enhance the dynamic range of temperature measurement. The velocity field measurement was attained by the use of the fray-level images taken for the flow field, and by introducing the cross-correlation technique. The temperature and the velocity fields of the forced and the natural convective flows neat the surface of a cartridge heater were measured simultaneously with the constructed measurement system.

Optimum design of injection mold heater for uniform curing of LSR seal for waterproof connector (방수 커넥터용 LSR Seal의 균일 경화를 위한 사출 금형 히터의 최적 설계)

  • Song, Min-Jae;Cha, Baeg-Soon;Hong, Seok-Kwan;Ko, Young-Bae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.310-315
    • /
    • 2017
  • Automotive waterproof connectors are highly functional parts that must be air-tight in a complex environment. In the LSR multi-cavity injection molding process for manufacturing waterproof connectors, it is important to maintain a uniform curing temperature between the cavities in order to obtain a quality product. For this purpose, we designed the capacity of the cartridge heater differently for each position, and then linked the heat transfer analysis and optimization module to obtain the optimal cartridge heater capacity. As a result of the optimization analysis, the temperature deviation between cavities was decreased from $13.1^{\circ}C$ to $8.1^{\circ}C$ compared with the case in which constant heater capacity was applied, so that the design criterion could be satisfied within a temperature deviation of $10^{\circ}C$ for uniform curing. This study suggests that this method can be applied efficiently to the design of a large area multi-cavity LSR mold heater.

Development of the Novel Dry and Wet Deposition Collector (새로운 건성 및 습성 침착 채취기의 개발)

  • 이병규;이채복
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.6
    • /
    • pp.675-684
    • /
    • 2000
  • A novel dry and wet deposition collector, which can overcome the several problems such as water evaporation cartridge cracks and high costs founded in the previous collector systems, has been constructed. ENVI-18 SPE adsorption cartridge has been used to measure atmospheric deposition of polycylic aromatic hydrocarbons (PAHs). A surrogate surface, consisted of water and methanol, was filled in the dry deposition funnel to simulate dry deposition onto water surface. A water supply system in order to compensat evaporation of the surrogate surface was used and it was consisted of a piston pump, a tubing pump, a overflow tube and a chamber system. A novel water vaporizing system to supply water onto the wet SPE cartridge system with a constant flow rate was developed. The novel water vaporizing system, consisted of a vacuum pump, a water supply reserviour and tube and a mini space heater, could prevent the PAHs adsorption cartridge cracks occurred in the previous collector and effectively adsorb PAHs. The novel dry and wet deposition collector showed a good adsorption, desorption, and recovery rates of PAHs. By reducing the number of pumps used and employing polypyopylene (PP) instead of teflon as a material of collection funnel, the total construction costs were much reduced as compared with the previous dry and wet deposition collectors.

  • PDF

Freezing and Melting Phenomena of Urea-water Solution for Diesel Vehicle SCR System (디젤차량 SCR 시스템용 요소수용액의 동결과 해동 현상)

  • Choi, B.C.;Seo, C.K.;Myong, K.J.
    • Journal of Power System Engineering
    • /
    • v.13 no.4
    • /
    • pp.5-10
    • /
    • 2009
  • Urea-SCR system, the selective catalytic reduction using urea as reducing agent, is a powerful technique to reduce nitrogen oxides(NOx) emitted from diesel engines. However, a tank of urea(32.5 wt%)-water solution can be frozen in low ambient temperature levels of below $-11^{\circ}C$. The purpose of this study is to understand freezing and melting phenomena of the urea-water solution, and its can be applied to get the urea-water solution from frozen it within 5 minutes after cold start. Factors considered were the type of heater and the urea tank shape. From the results, it was found that melting volume of cartridge heater B during 5 minutes of heating period was 83ml when supplying electric power of 150W. Horizontal heater B, which was put in the narrow bottom space of the tank T1, had fast melting characteristics.

  • PDF

고자장, 저온 환경의 UHV surface magneto-optical Kerr effect 장비 구축 및 Fe/Cr(001)계의 자성특성 연구

  • Park, Yong-Seong;O, Yong-Rok;Hong, Ji-Sang;Kim, Won-Dong;Hwang, Chan-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.400-400
    • /
    • 2010
  • 우리는 기본 진공 $10^{-11}\;Torr$의 UHV surface magneto-optical Kerr effect (SMOKE) 시스템을 quarter-wave plate를 사용하였던 기존의 방식에서 PEM (photo elastic modulator)를 사용하는 방식으로 장비의 기능을 향상시켰다. 기존 quarter-wave plate를 사용하는 방식의 경우 Kerr signal을 구하기 위해 편광자와 검광자를 수직으로 두어 광량을 0으로 만들어야 한다. 그러나 금속의 경우 대부분 가시광선 영역에서 큰 반사율 때문에 측정되는 광량이 편광자와 검광자를 거치면서 넓은 각도 범위에서 최소값을 갖기 때문에 정확한 영점을 잡는 데 한계가 있다. 이러한 단점을 해결하기 위하여 우리는 PEM을 이용한 위상변조방식을 사용하였다. 위상변조 방식은 Kerr signal과 관계된 양을 PEM을 이용하여 50 kH ($1{\omega}$)와 100 kH ($2{\omega}$)의 진동 주파수에 공조시키고 이를 Lock-in-amplifier를 사용하여 탐지하기 때문에 좋은 sensitivity를 얻을 수 있을 뿐 아니라 Kerr ellipticity와 Kerr rotation을 동시에 측정할 수 있다. 자화에 필요한 전자석은 순철로 된 코어를 제작하여 챔버에 부착하였고 10 A에서 최대 7 kOe의 고자장을 얻을 수 있어 포화자화가 큰 물질에 대해서도 필요한 자성영역까지 측정이 가능하게 하였다. 또 저온 측정을 위해 SMOKE 샘플 홀더를 개조하여 액체 질소를 이용하여 100 K 근방의 영역에서 온도를 제어할 수 있도록 저온 장치를 구성하였다. 여기에서 샘플 근처에 위차한 e-beam heater가 장착된 고온 부분과 액체 질소 냉각, 온도감지를 위한 센서, cartridge heater가 장착된 저온 부분을 sapphire plate로 분리하여 저온용 cartridge heater의 파손을 최소화하였다. 이러한 SMOKE 시스템을 구성한 후에 우리는 Fe/Cr(001)시스템의 자성특성에 대해 연구하였다. Fe/Cr 시스템은 Fe/Cr/Fe의 exchange coupling이나 bulk Cr의 복잡한 자성 특성 때문에 주목을 받아왔다. 이 연구에서 우리는 저온 및 상온에서 Cr(001) 단결정 위에 증착된 Fe 박막의 자성 특성을 보고한다.

  • PDF

Experiment of Natural Circulation Loop Using a Cryocooler (극저온냉동기를 이용한 자연순환 루프의 실험)

  • Kim, M.J.;Chang, H.M.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2194-2199
    • /
    • 2007
  • An experimental study is performed to investigate the thermal and flow characteristics of subcooled liquid nitrogen in a natural circulation loop. Experimental apparatus is designed and constructed such that a closed loop is cooled at the top by a cryocooler and heated nearly at the bottom by cartridge heaters. Steady state is obtained by controlling the heating power to the cartridge heaters and a thin-film heater to reduce the cooling power of the cryocooler. Temperature is measured at several locations of the loop and the mass flow rate through the loop is estimated from the energy balance in terms of the measured temperatures. Experiment is repeated for various values of the vertical height between the cooling and heating parts. The results show that the heat transfer capability of the loop has a maximum at a certain value of height. The optimal height to maximize the heat transfer is in a good agreement with analytical prediction to take into account the buoyancy and viscous forces in the loop.

  • PDF

An Experimental visualization of the Pool Boiling Heat Transfer on the Inclined square surface (경사진 가열면에서의 수조비등에 대한 가시화 연구)

  • Kim, J.K.;Song, J.H.;Kim, S.B.;Kim, H.D.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.63-68
    • /
    • 2001
  • An experimental study was carried out to identify the various regimes of natural convective boiling and to determine the Critical Heat Flux(CHF) on a 70mm square surface which is inclined at $180^{\circ}$(upward), $90^{\circ}, \;45^{\circ}$. The heater block made of copper with cartridge heaters is submerged in a water tank with windows for visualization. As the heat flux increases from $100kW/m^2$ to $1.1MW/m^2$, the heat transfer regime migrates from the nucleate boiling to film boiling and results in a rapid heat up of the heater block. An explosive vapor generation on the heated surface, whose size and frequency are characterized by the heat flux, is visualized by using a digital camcorder with $512{\times}512$ pixel size at 30fps.

  • PDF

Measurement Technique for Single Phase Local Heat Transfer Coefficients of Subchannels in a Rod Bundle using a Copper Sensor (봉다발 부수로의 단상 국부열전달 계수 측정기법에 관한 연구)

  • Seo, Jeong-Sik;Choi, Young-Don;Bea, Kyong-Kuen;An, Jeong-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.191-196
    • /
    • 2007
  • This paper presents the measuring technique for local heat transfer coefficients using a copper sensor in a rod bundle with mixing vanes. A copper sensor consists of a cartridge heater and four pieces of thermocouple. The Heater is located at the center of the copper sensor and thermocouples measure the surface temperature of the copper sensor. Unheated copper sensor and heated copper sensor are able to measure the local heat transfer coefficient at the position where the heated copper sensor is installed. However the entire region of a rod bundle is actually not heated, the decay of local heat transfer coefficients measured represents overestimated value rather than an actual value. The calibration curve for local heat transfer coefficients is presented using the correction factor calculated by CFD.

  • PDF