4-레벨 인버터를 위한 저변조지수 영역의 DC-링크 전압 제어기법 (A DC-Link Voltage Control Scheme for 4-Level Inverter at Low Modulation Index)

  • 송종환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.325-329
    • /
    • 2000
  • An effective Carrier-Based PWM scheme that enables the instantaneous quality of each branch point voltage of a diode clamped 4-level inverter to be reduced at a low modulation index is described. This scheme presents a computed zero sequence voltage of PWM by the feedback of both DC-link voltages and load currents. The proposed PWM scheme enables to increase the controllable region of DC-link voltage and makes it possible to operate with small DC-link capacitors. The validity of the proposed PWM scheme is verified by simulation results.

  • PDF

Reduction of Common Mode Voltage in Asymmetrical Dual Inverter Configuration Using Discontinuous Modulating Signal Based PWM Technique

  • Reddy, M. Harsha Vardhan;Reddy, T. Bramhananda;Reddy, B. Ravindranath;Suryakalavathi, M.
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1524-1532
    • /
    • 2015
  • Conventional space vector pulse width modulation based asymmetrical dual inverter configuration produces high common mode voltage (CMV) variations. This CMV causes the flow of common mode current, which adversely affects the motor bearings and electromagnetic interference of nearby electronic systems. In this study, a simple and generalized carrier based pulse width modulation (PWM) technique is proposed for dual inverter configuration. This simple approach generates various continuous and discontinuous modulating signals based PWM algorithms. With the application of the discontinuous modulating signal based PWM algorithm to the asymmetrical dual inverter configuration, the CMV can be reduced with a slightly improved quality of output voltage. The performance of the continuous and discontinuous modulating signals based PWM algorithms is explored through both theoretical and experimental studies. Results show that the discontinuous modulating signal based PWM algorithm efficiently reduces the CMV and switching losses.

2상 유도전동기 구동 2상 인버터를 위한 새로운 PWM제어방식 I - 2-레그 타입 및 4-레그 타입의 경우 - (Novel PWM Methods for Two-Leg and Four-leg Two-Phase Inverter Fed Two-Phase Induction Motor)

  • 장도현
    • 전력전자학회논문지
    • /
    • 제10권4호
    • /
    • pp.331-338
    • /
    • 2005
  • 본 논문에서는 2상 유도전동기의 가변속장치인 2-레그 및 4-레그 2상 인버터의 PWM 방식을 제안하였다. 기존의 SVPWM방식을 2-레그 인버터에 적용하기가 복잡하나, 본 논문에서는 캐리어 삼각파 PWM방식으로 단순화시켰다. 4-레그 인버터의 경우 전압벡터가 16개가 되어 전형적인 공간전압벡터이론을 적용하기가 복잡하다. 따라서, 본 논문에서는 이를 대신하여 2-레그 인버터형 삼각파 PWM방식을 기본으로 하여 4-레그 인버터에 적용할 수 있는 삼각파 PWM파형으로 단순화하였다. 제안된 2상 PWM방식에 대한 타당성을 확인하기 위해 모의 실험과 실험이 실행되었다.

Cascaded 멀티레벨 인버터의 고장 허용 제어를 위한 Level-Shifted PWM 기반의 새로운 변조 기법 (A Novel Modulation Strategy Based on Level-Shifted PWM for Fault Tolerant Control of Cascaded Multilevel Inverters)

  • 김석민;이준석;이교범
    • 전기학회논문지
    • /
    • 제64권5호
    • /
    • pp.718-725
    • /
    • 2015
  • This paper proposes a novel level-shifted PWM (LS-PWM) strategy for fault tolerant cascaded multilevel inverter. Most proposed fault-tolerant operation methods in many of studies are based on a phase-shifted PWM (PS-PWM) method. To apply these methods to multilevel inverter systems using LS-PWM, two additional steps will be implemented. During the occurrence of a single-inverter-cell fault, the carrier bands scheme is reconfigured and modulation levels of inverter cells are reassigned in this proposed fault-tolerant operation. The proposed strategy performs balanced three-phase line-to-line voltages and line currents when a switching device fault occurs in a cascaded multilevel inverter using LS-PWM. Simulation and experimental results are included in the paper to verify the proposed method.

A Simplified Carrier-Based Pulse-Width Modulation Strategy for Two-level Voltage Source Inverters in the Over-modulation Region

  • Jing, Feng;He, Feng-You
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1480-1489
    • /
    • 2017
  • In this study, a carrier-based pulse-width modulation (PWM) method for two-level voltage source inverters in the over-modulation region is proposed. Based on the superposition principle, the reference voltage vectors outside the linear modulation boundary are adjusted to relocate to the vector hexagon, while their fundamental magnitudes are retained. In accordance with the adjusted reference vector, the corresponding modulated waves are respectively deduced in over-modulation mode I and II to generate the gate signals of the power switches, guaranteeing the linearity of the fundamental output phase voltage in the over-modulation region. Moreover, due to the linear relationship between the voltage vector and the duty ratios, the complicated sector identification and holding angle calculation found in previous methods are avoided in the modulated wave synthesis, which provides great simplicity for the proposed carrier-based over-modulation strategy. Experimental results demonstrate the effectiveness and validity of the proposed method.

Trapezoidal PWM 전류원 인버터에서 최소 Speed Ripple을 위한 펄스 수 및 변조도의 결정 (Selection of pulse number and modulation index for minimum speed ripple in trapezoidal CSI-PWM)

  • 권우현;구본호;이치환;이창화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.127-129
    • /
    • 1988
  • Square-wave current source inverter drives suffer from torque pulsation and speed variation at low speed. Attempts to minimize these problems, CSI PWM strategies have been reported. It is shown that these PWM strategies are based on unnecessarily restrictive modulation laws. In this paper, trapezoidal PWM strategy for CSI is investigated theoratically by double fourier series and we proposed Harmonic Speed ripple Factor(HSF) that is independent of motor parameters and load conditions. Speed ripple are considered in T-PWM and square wave inverter by HSF. We obtain modulation index(M) and carrier ratio (CR) for minimum speed ripple.

  • PDF

TMS320F240을 이용한 PWM 인버터 유도전동기 구동 시스템의 전도노이즈 저감을 위한 스위칭 기법 (A Switching Technique for Common Mode Voltage Reduction of PWM-Inverter Induction Motor Drive System Using TMS320F240)

  • 박규현;김이훈;원충연;김규식;최세완;함년근
    • 전력전자학회논문지
    • /
    • 제8권1호
    • /
    • pp.89-97
    • /
    • 2003
  • PWM 인버터에 의해 구동리근 유도전동기에 발생되는 고주파 커먼 모드 전압은 전도성 EMI, 전통기 접지전류, 베어링 전류 및 다른 원치 않는 결과의 주원인이 된다. 인버터 제어의 무효벡터 스위칭 상태는 나머지 유효벡터 스위칭 상태에 비교하여 큰 커먼 모드 전압을 일으킨다. 그러므로 이 논문은 커먼 모드 전압을 완화하는 스위칭기법을 다룬다. 즉 정현파 PWM 기법을 기본으로 한 커먼 모드 전압 제거방법을 제안하였다. PWM 신호는 각자의 정현과 기준신호와 120$^{\circ}$위상차가 나는 3개의 캐리어 파형과 비교하여 발생된다. 시뮬레이션과 실험적 결과는 제안된 PWM 기법에서 커먼 모드 전압이 종래의 PWM 기법보다 약 66% 더 저감됨을 보였다.

3-level inverter를 위한 새로운 Carrier-Based DPWM 기법 (The Novel Carrier-Based DPWM Method for 3-level Inverter)

  • 강대욱
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.347-350
    • /
    • 2000
  • This paper deals with the novel DPWM(discontinuous PWM) for 3-level inverter. Although DPWM methods generate higher harmonics than SVPWM they are of special interest because of their lower switching losses. And in the high modulation region the harmonic characteristics of DPWM is superior to the that of CPWM. However when DPWM applies to the 3-level inverter there is the problem that the output state is varied suddenly in the low modulation region($\textrm{m}_{I}$=0~0.5) The novel DPWM that this problem improves will be introduced.

  • PDF

New Generalized PWM Schemes for Multilevel Inverters Providing Zero Common-Mode Voltage and Low Current Distortion

  • Nguyen, Nho-Van;Nguyen, Tam-Khanh Tu
    • Journal of Power Electronics
    • /
    • 제19권4호
    • /
    • pp.907-921
    • /
    • 2019
  • This paper presents two advanced hybrid pulse-width modulation (PWM) strategies for multilevel inverters (MLIs) that provide both common-mode voltage (CMV) elimination and current ripple reduction. The first PWM utilizes sequences that apply one switching state at the double ends of a half-carrier cycle. The second PWM combines the advantages of the former and an existing four-state PWM. Analyses of the harmonic characteristics of the two groups of switching sequences based on a general switching voltage model are carried out, and algorithms to optimize the current ripple are proposed. These methods are simple and can be implemented online for general n-level inverters. Using a three-level NPC inverter and a five-level CHB inverter, good performances in terms of the root mean square current ripple are obtained with the proposed PWM schemes as indicated through improved harmonic distortion factors when compared to existing schemes in almost the entire region of the modulation index. This also leads to a significant reduction in the current total harmonic distortion. Simulation and experimental results are provided to verify the effectiveness of the proposed PWM methods.

Study on Hybrid PWM Method under Low Switching Frequency

  • Kekang, Wei;Zheng, Trillion Q.;Wang, Ran;Wang, Chenchen
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권2호
    • /
    • pp.64-69
    • /
    • 2012
  • This paper presents a hybrid pulse width modulation (PWM) method under low switching frequency conditions based on space vector PWM (SVPWM) and selective harmonic eliminated PWM (SHEPWM), which use asynchronous carrier modulation SVPWM at low frequency, and SHEPWM at high frequency, a square wave after rated conditions. A transitive strategy is proposed to realize a smooth transition of individual modes including SVPWM, SHEPWM and square waves. Experimental results confirm this hybrid modulation method and their transition are reasonable and proper.