• Title/Summary/Keyword: carotid artery stent

Search Result 53, Processing Time 0.025 seconds

Usefulness of Silent MRA for Evaluation of Aneurysm after Stent-Assisted Coil Embolization

  • You Na Kim;Jin Wook Choi;Yong Cheol Lim;Jihye Song;Ji Hyun Park;Woo Sang Jung
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.246-255
    • /
    • 2022
  • Objective: To determine the usefulness of Silent MR angiography (MRA) for evaluating intracranial aneurysms treated with stent-assisted coil embolization. Materials and Methods: Ninety-nine patients (101 aneurysms) treated with stent-assisted coil embolization (Neuroform atlas, 71 cases; Enterprise, 17; LVIS Jr, 9; and Solitaire AB, 4 cases) underwent time-of-flight (TOF) MRA and Silent MRA in the same session using a 3T MRI system within 24 hours of embolization. Two radiologists independently interpreted both MRA images retrospectively and rated the image quality using a 5-point Likert scale. The image quality and diagnostic accuracy of the two modalities in the detection of aneurysm occlusion were further compared based on the stent design and the site of aneurysm. Results: The average image quality scores of the Silent MRA and TOF MRA were 4.38 ± 0.83 and 2.78 ± 1.04, respectively (p < 0.001), with an almost perfect interobserver agreement. Silent MRA had a significantly higher image quality score than TOF MRA at the distal internal carotid artery (n = 57, 4.25 ± 0.91 vs. 3.05 ± 1.16, p < 0.001), middle cerebral artery (n = 21, 4.57 ± 0.75 vs. 2.19 ± 0.68, p < 0.001), anterior cerebral artery (n = 13, 4.54 ± 0.66 vs. 2.46 ± 0.66, p < 0.001), and posterior circulation artery (n = 10, 4.50 ± 0.71 vs. 2.90 ± 0.74, p = 0.013). Silent MRA had superior image quality score to TOF MRA in the stented arteries when using Neuroform atlas (4.66 ± 0.53 vs. 3.21 ± 0.84, p < 0.001), Enterprise (3.29 ± 1.59 vs. 1.59 ± 0.51, p = 0.003), LVIS Jr (4.33 ± 1.89 vs. 1.89 ± 0.78, p = 0.033), and Solitaire AB stents (4.00 ± 2.25 vs. 2.25 ± 0.96, p = 0.356). The interpretation of the status of aneurysm occlusion exhibited significantly higher sensitivity with Silent MRA than with TOF MRA when using the Neuroform Atlas stent (96.4% vs. 14.3%, respectively, p < 0.001) and LVIS Jr stent (100% vs. 20%, respectively, p = 0.046). Conclusion: Silent MRA can be useful to evaluate aneurysms treated with stent-assisted coil embolization, regardless of the aneurysm location and type of stent used.

Long-Term Outcomes of Stenting on Non-Acute Phase Extracranial Supra-Aortic Dissections

  • Jiang, Yeqing;Di, Ruoyu;Lu, Gang;Huang, Lei;Wan, Hailin;Ge, Liang;Zhang, Xiaolong
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.3
    • /
    • pp.422-429
    • /
    • 2022
  • Objective : Extracranial supra-aortic dissections (ESADs) with severe stenosis, occlusion and/or pseudoaneurysm presents potential risk of stroke. Endovascular stenting to reconstruct non acute phase ESADs (NAP-ESADs) is an alternative to anticoagulant or antiplatelet therapy. However, its feasibility, safety and efficacy of stenting in NAP-ESADs is unclear. This study aims to investigate the long-term outcomes of the feasibility, safety and efficacy of stenting in NAP-ESADs. Methods : Seventy-four patients with 91 NAP-ESAD vessels with severe stenosis, occlusion and/or pseudoaneurysm presents potential risk of stroke who underwent stent remodeling were enrolled into this respective study from December 2008 to March 2020. Technical success rate, complications, clinical and angiographic results were harvested and analyzed. Results : Success rate of stent deployment was 99% (90/91) with no procedural mortality or morbidity. Transient ischemic attack occurred in three patients during operation (4.1%, 3/74). Asymptomatic embolisms of distal intracranial vessels were found in two patients (2.7%, 2/74). One hundred and forty-two stents deployed at 85 carotid (135 stents) and six vertebral (seven stents) vessels. Six stent types (Wingspan, 28/135, 20.7%; Solitaire, 10/135, 7.4%; Neuroform, 8/135, 5.9%; LVIS, 2/135, 1.5%; Precise, 75/135, 55.6%; Acculink, 12/135, 8.9%) were deployed at carotid arterial dissection while two types (Wingspan, 5/7, 71.4%; Solitaire 2/7, 28.6%) at vertebral arterial dissection. Digital subtracted angiography (56%, 51/91), computational tomography angiography (41.8%, 38/91) and high resolution magnetic resonance imaging (2.2%, 2/91) were adopted for follow up, with a mean time of 17.2±15.4 months (5-77). All patient modified Rankin Scale scores showed no increase at discharge or follow-up. Angiographically, dissections in 86 vessels in 69 patients (94.5%, 86/91) were completely reconstructed with only minor remnant dissections in four vessels in four patients (4.4%, 4/91). Severe re-stenosis in the stented segment required re-stenting in one patient (1.1%, 1/91). Conclusion : Stent remodeling technique provides feasible, safe and efficacious treatment of ESADs patients with severe stenosis, occlusion and/or pseudoaneurysm.

Risk Factors for Developing Large Emboli Following Carotid Artery Stenting

  • Kwon, Sae Min;Cheong, Jin Hwan;Lee, Sang Kook;Park, Dong Woo;Kim, Jae Min;Kim, Choong Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.3
    • /
    • pp.155-160
    • /
    • 2013
  • Objective : The introduction and development of the embolic protecting device (EPD) has resulted in a decreased rate of stroke after carotid artery stenting (CAS). The authors performed a retrospective study to investigate the risk factors for developing large emboli after CAS which can lead to ischemic events. Methods : A total of 35 consecutive patients who underwent CAS between January 2009 and March 2012 were included in this study. Patients were divided into two groups including those with small emboli (group A; grade 1, 2) and those with large emboli (group B; grade 3, 4). The size and number of emboli were assigned one of four grades (1=no clots, 2=1 or 2 small clots, 3=more than 3 small clots, 4=large clots) by microscopic observation of the EPD after CAS. We compared demographic characteristics, medical history, and angiographic findings of each group. Results : Thirty-five patients underwent CAS, and technical success was achieved in all cases. Twenty-three patients were included in group A and 12 patients in group B. Our results demonstrated that advanced age [odds ratio (OR) 1.24; 95% confidence interval (CI) 1.01-1.52; p=0.044] and smoking (OR 42.06; CI 2.828-625.65, p=0.006) were independent risk factors for developing large emboli after CAS. Conclusion : In patients with carotid artery stenosis treated with CAS, advanced age and smoking increased the number and size of emboli. Although use of an EPD is controversial, it may be useful in CAS in patients with risk factors for large emboli in order to reduce the risk of ischemic events.

Covered Stenting Is an Effective Option for Traumatic Carotid Pseudoaneurysm with Promising Long-Term Outcome

  • Wang, Kai;Peng, Xiao-xin;Liu, Ao-fei;Zhang, Ying-ying;Lv, Jin;Xiang, Li;Liu, Yun-e;Jiang, Wei-jian
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.5
    • /
    • pp.590-597
    • /
    • 2020
  • Objective : Covered stenting is an optional strategy for traumatic carotid pseudoaneurysm, especially in malignant conditions of potential rupture, but the long-term outcomes are not clear. Our aim was to determine if covered stenting is an effective option for traumatic carotid pseudoaneurysm with promising long-term outcomes. Methods : Self-expanding Viabahn and balloon-expandable Willis covered stents were separately implanted for extra- and intracranial traumatic carotid pseudoaneurysm. The covered stent was placed across the distal and proximal pseudoaneurysm leakage under roadmap guidance. Procedural success was defined as technical success (complete exclusion of the pseudoaneurysm and patency of the parent artery) without a primary end point (any stroke or death within 30 days after the procedure). Long-term outcomes were evaluated as ischemic stroke in the territory of the qualifying artery by clinical follow-up through outpatient or telephone consultation and as the exclusion of the pseudoaneurysm and patency of the parent artery by imaging follow-up through angiography. Results : Five patients with traumatic carotid pseudoaneurysm who underwent covered stenting were enrolled. The procedural success rate was 100%. No ischemic stroke in the territory of the qualifying artery was recorded in any of the five patients during a mean clinical follow-up of 44±16 months. Complete exclusion of the pseudoaneurysm and patency of the parent artery were maintained in all five patients during a mean imaging follow-up of 39±16 months. Conclusion : Satisfactory procedural and long-term outcomes were obtained, suggesting that covered stenting is an effective option for traumatic carotid pseudoaneurysm.

Sole Stenting Technique for Treatment of Complex Aneurysms

  • Kim, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.6
    • /
    • pp.545-551
    • /
    • 2009
  • Objective : Complex aneurysms such as fusiform and very small aneurysms (< 3 mm) are challenging in neurovascular and endovascular surgery. Author reports follow-up results of 9 cases treated by sole stent technique with pertinent literature review. Methods : A retrospective study was made of 9 patients who were treated by sole stenting technique for cerebral aneurysm between January 2003 and January 2009. Two of them had fusiform aneurysm, 5 had very small aneurysm, and 2 had small saccular aneurysm. Five patients had ruptured aneurysms and four had unruptured aneurysms. Seven aneurysms were located in the internal carotid artery (ICA), 1 in the middle cerebral artery (MCA) and 1 in the basilar artery. Follow-up cerebral angiography was performed at post-procedure 3 months, 6 months, and 12 months. Mean follow-up period is 30 months (ranged from 3 days to 30 months). Results : Aneurysm size was decreased in 6 of 9 cases on follow-up images and was not changed in 3 cases. Although total occlusion was not seen, patients had stable neurological condition and angiographic result. The procedural complication occurred in 2 cases. One was coil migration and the other was suboptimal deployment of stent, and both were asymptomatic. Re-bleeding and thromboembolic complication had not been occurred. Conclusion : Sole stenting technique is relatively effective and safe as an alternative treatment for fusiform and very small aneurysms.

Treatment for Giant Fusiform Aneurysm Located in the Cavernous Segment of the Internal Carotid Artery Using the Pipeline Embolization Device

  • Oh, Se-Yang;Kim, Myeong Jin;Kim, Bum-Soo;Shin, Yong Sam
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.1
    • /
    • pp.32-35
    • /
    • 2014
  • The pipeline embolization device (PED) is a new endovascular device for treatment of complex, fusiform and wide-neck intracranial aneurysms. The main mechanism of this stent is to divert the flow in the parent artery with reduction of inflow in the aneurysm leading to thrombosis. We treated a 40-year-old woman who had left facial pain and orbit discomfort. Angiography showed a giant fusiform aneurysm located in the cavernous segment of the left internal carotid artery. A PED was successfully deployed across the aneurysm. The procedure and post-procedural course were uneventful. After 3 months, angiography showed complete obliteration of the aneurysm with good patency of the branching vessels originating from the deployed segment. The patient's symptoms improved completely without complications.

Clinical Analysis Comparing Efficacy between a Distal Filter Protection Device and Proximal Balloon Occlusion Device during Carotid Artery Stenting

  • Lee, Jong Hyeok;Sohn, Hee Eon;Chung, Seung Young;Park, Moon Sun;Kim, Seong Min;Lee, Do Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.4
    • /
    • pp.316-320
    • /
    • 2015
  • Objective : The main concern during transfemoral carotid artery stenting (CAS) is preventing cerebral embolus dislodgement. We compared clinical outcomes and intraprocedural embolization rates of CAS using a distal filter protection device or proximal balloon occlusion device. Methods : From January 2011 to March 2015, a series of 58 patients with symptomatic or asymptomatic internal carotid artery stenosis ${\geq}70%$ were treated with CAS with embolic protection device in single center. All patients underwent post-CAS diffusion-weighted magnetic resonance imaging (DW-MRI) to detect new ischemic lesions. We compared clinical outcomes and postprocedural embolization rates. Results : CAS was performed in all 61 patients. Distal filter protection success rate was 96.6% (28/29), whose mean age was 70.9 years, and mean stenosis was 81%. Their preprocedural infarction rate was 39% (11/28). Subsequent DW-MRI revealed 96 new ischemic lesions in 71% (20/28) patients. In contrast, the proximal balloon occlusion device success rate was 93.8% (30/32), whose mean age was 68.8 years and mean stenosis was 86%. Preprocedure infarction rate was 47% (14/30). DW-MRI revealed 45 new ischemic lesions in 57% (17/30) patients. Compared with distal filter protection device, proximal balloon occlusion device resulted in fewer ischemic lesions per patient (p=0.028). In each group, type of stent during CAS had no significant effect on number of periprocedural embolisms. Only 2 neurologic events occurred in the successfully treated patients (one from each group). Conclusion : Transfemoral CAS with proximal balloon occlusion device achieves good results. Compared with distal filter protection, proximal balloon occlusion might be more effective in reducing cerebral embolism during CAS.

Aortic Arch Debranching and Antegrade Stent Graft Placement in an Expanding Distal Dissecting Aneurysm after Repair of an Acute Type I Aortic Dissection (Type I 급성 대동맥 박리 수술 후 진행하는 원위부 박리성 동맥류에 대한 대동맥궁 탈분지술과 전향적 대동맥궁 스텐트 그라프트의 설치)

  • Baek, Wan-Ki;Kim, Young-Sam;Lim, Hyun-Kyoung;Yoon, Yang-Han;Kim, Joung-Taek;Kim, Kwang-Ho
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.729-733
    • /
    • 2010
  • Endovascular treatment of the aortic aneurysm with a stent graft is rapidly evolving. We describe here a case of hybrid TEVAR (thoracic endovascular aortic repair) in which the stent grafts were placed in the aortic arch after debranching of the arch vessels. The patient had undergone ascending aorta replacement for acute type I aortic dissection 2.5 years earlier. The aneurysmal change of the distal dissection progressed with time. A provisional bypass surgery from the ascending aorta to the innominate artery and left carotid artery was performed and then stent grafts were inserted via an antegrade route that covered the whole aortic arch and proximal descending thoracic aorta.

Microguidewire Looping to Traverse Stented Parent Arteries of Intracranial Aneurysms

  • Cho, Young Dae;Rhim, Jong Kook;Yoo, Dong Hyun;Kang, Hyun-Seung;Kim, Jeong Eun;Han, Moon Hee
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.2
    • /
    • pp.262-268
    • /
    • 2017
  • Objective : Stents are widely used in coil embolization of intracranial aneurysms, but on occasion, a microcatheter must traverse a stented segment of artery (so-called trans-cell technique) to select an aneurysm, or double stenting may necessary. In such situations, microguidewire passage and microcatheter delivery through a tortuous stented parent artery may pose a technical challenge. Described herein is a microguidewire looping technique to facilitate endovascular navigation in these circumstances. Methods : To apply this technique, the microguidewire tip is looped before entering the stented parent artery and then advanced distally past the stented segment, with the loop intact. Rounding of the tip prevents interference from stent struts during passage. A microcatheter is subsequently passed into the stented artery for positioning near the neck of aneurysm, with microguidewire assistance. The aneurysm is then selected, steering the microcatheter tip (via inner microguidewire) into the dome. Results : This technique proved successful during coil embolization of nine saccular intracranial aneurysms (internal carotid artery [ICA], 6; middle cerebral artery, 2; basilar tip, 1), performing eight trans-cell deliveries and one additional stenting. Selective endovascular embolization was enabled in all patients, resulting in excellent clinical and radiologic outcomes, with no morbidity or mortality directly attributable to microguidewire looping. Conclusion : Microguidewire looping is a reasonable alternative if passage through a stented artery is not feasible by traditional means, especially at paraclinoid ICA sites.

Hybrid Operation of a Kommerell’s Diverticulum with Left Aberrant Subclavian Artery (비정상 좌측 쇄골하동맥을 동반한 Kommerell 게실의 하이브리드 수술법)

  • Kim, Hye-Won;Lee, Jae-Won;Jung, Sung-Ho;Jung, Jae-Seung;Jung, Jong-Pil
    • Journal of Chest Surgery
    • /
    • v.43 no.4
    • /
    • pp.458-461
    • /
    • 2010
  • A 53-year-old woman had right aortic arch, Kommerell’s diverticulum and aberrant left subclavian artery (LSA) without any compressive symptoms. Hybrid operation was performed. This consisted of LSA bypass using a 6 mm ringed Gore-Tex graft between the left common carotid artery and aberrant LSA via a left supraclavicular incision, and stent graft insertion into the aortic arch via the right femoral artery. Postoperative computed tomography as well as intraoperative angiography demonstrated successful occlusion of Kommerell’s diverticulum and bypass of the aberrant LSA. There were no complications related to the operation or the intervention.