• Title/Summary/Keyword: cardiac device

Search Result 138, Processing Time 0.025 seconds

Comparison of cardiopulmonary resuscitation quality using the over-the-head and lateral conventional positions with a bag-valve-mask device performed by a single rescuer : A manikin study (백밸브마스크를 이용한 1인 심폐소생술에서 구조자 위치 변화에 따른 가슴압박과 인공호흡의 질 변화 연구)

  • Uhm, Tai-Hwan;Jung, Hyung-Keon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.20 no.1
    • /
    • pp.7-15
    • /
    • 2016
  • Purpose: There are few studies on the quality of cardiopulmonary resuscitation (CPR) performed by a single rescuer using a bag-valve-mask device. The aim of this study is to compare CPR quality outcomes according to the rescuer's position or mask fixation grip method and to determine the optimal means of achieving therapeutic goals. Methods: The three CPR methods were defined as over-the-head, lateral-superior, and lateral-inferior, depending on the rescuer's position or mask fixation hand placement. CPR quality was estimated for 83 paramedic students who performed 5 minutes of CPR in a randomized sequence on a manikin using each of the three methods. Results: The over-the-head method showed no advantage for cardiac compression and ventilation quality, but minimized the rescuer's fatigue score. Conclusion: In contrast to previous studies or prevailing beliefs, the lateral-superior position is optimal for achieving therapeutic goals with moderate or minimal rescuer fatigue.

Development and Evaluation of Pneumatic Ventricular Assist Device (공압식 심실보조장치의 개발 및 평가)

  • Lee, S.H.;Park, I.T.;Kim, S.H.;Han, D.S.;Lee, H.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.247-250
    • /
    • 1995
  • The purpose of this paper is to develop diaphragm-type pneumatic ventricular assist device(VAD) for clinical application and to evaluate its performance through the mock circulation system. The blood housing and diaphragm are made by coating pellethane on the metallic mold and the back plate is made by machining process. The relations of cardiac output(CO) vs. beat rate and CO vs. systolic-to-diastolic rate was estimated through the mock test and hemodynamic waves are recorded for the evaluation of VAD. As a result, the volume of blood pump is 70 ml, maximum CO is 5 L/min and CO has a close relation to the input resistance of blood pump. The hemodynamic data and waves showed this system can be applicable to the animal experiment.

  • PDF

Development of Pediatric VAD(VICT) and its in-vivo Test (소아용 좌심실 보조장치(VICT)의 개발 및 in-vivo 실험)

  • Lee, S.H.;Park, I.T.;Kim, S.H.;Lee, K.W.;Lee, K.H.;Ahn, H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.207-212
    • /
    • 1996
  • We developed pneumatic blood pump and its driving system as a pediatric ventricular assist device. The blood pump is diaphragm type system and its blood contacting area is coated with Bio-Span. The driving unit Is consists of dual pumps, valves for the reliable blood pumping and its controller uses 80C196(Intel) as a main processor. The acute animal experiment was performed with dogs and its body weight is about 20 kg. The maximum cardiac output is about 2.1 l/min and the pressure and flow curves showed reliable operation as assist device.

  • PDF

Palliative and end-of-life care for heart failure patients in an aging society

  • Okumura, Takahiro;Sawamura, Akinori;Murohara, Toyoaki
    • The Korean journal of internal medicine
    • /
    • v.33 no.6
    • /
    • pp.1039-1049
    • /
    • 2018
  • The populations of Asian countries are expected to age rapidly in the near future, with a dramatic increase in the number of heart failure (HF) patients also anticipated. The need for palliative and end-of-life care for elderly patients with advanced HF is currently recognized in aging societies. However, palliative care and active treatment for HF are not mutually exclusive, and palliative care should be provided to reduce suffering occurring at any stage of symptomatic HF after the point of diagnosis. HF patients are at high risk of sudden cardiac death from the early stages of the disease onwards. The decision of whether to perform cardiopulmonary resuscitation in the event of an emergency is challenging, especially in elderly HF patients, because of the difficulty in accurately predicting the prognosis of the condition. Furthermore, advanced HF patients are often fitted with a device, and device deactivation at the end of life is a complicated process. Treatment strategies should thus be discussed by multi-disciplinary teams, including palliative experts, and should consider patient directives to address the problems discussed above. Open communication with the HF patient regarding the expected prognosis, course, and treatment options will serve to support the patient and aid in future planning.

Prototype Model Design and Implementation of Fetal Heart Sound Measurement Device (심장 초음파 측정기의 프로토 타입 모델 설계 및 구현)

  • Choi, Sung-Jai
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.3
    • /
    • pp.111-116
    • /
    • 2022
  • In the paper, A prototype Fetal Heart Monitor, mini - size, was designed and produced for pre-mothers to measure the rate and rhythm of their features's heart at home.Pre-mothers could listen fetal heart rhythm through an inner bluetooth speaker ant the monitor. LED colors show the frequency of fetal heart rate variability on the monitor. All measured health information, by ultrasonic resonator and bluetooth speaker, is linked to a mother's smart phone. A test verified this simple measuring device helps users discover the symptoms of fetal health. Patients using at home devices usefully prevent sudden cardiac death and myocardial infraction by discovering symptoms.

A Combined QRS-complex and P-wave Detection in ECG Signal for Ubiquitous Healthcare System

  • Bhardwaj, Sachin;Lee, Dae-Seok;Chung, Wan-Young
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.2
    • /
    • pp.98-103
    • /
    • 2007
  • Long term Electrocardiogram (ECG) [1] analysis plays a key role in heart disease analysis. A combined detection of QRS-complex and P-wave in ECG signal for ubiquitous healthcare system was designed and implemented which can be used as an advanced warning device. The ECG features are used to detect life-threating arrhythmias, with an emphasis on the software for analyzing QRS complex and P-wave in wireless ECG signals at server after receiving data from base station. Based on abnormal ECG activity, the server will transfer alarm conditions to a doctor's Personal Digital Assistant (PDA). Doctor can diagnose the patients who have survived from cardiac arrhythmia diseases.

Intensive management of acute right heart failure (급성 우심 부전의 집중 치료)

  • Kim, Gi Beom;Noh, Chung Il
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.11
    • /
    • pp.1041-1048
    • /
    • 2007
  • Not a few patients in children and adolescents are suffering from right ventricular (RV) dysfunction resulting from various conditions such as chronic lung disease, left ventricular dysfunction, pulmonary hypertension, or congenital heart defect. The RV is different from the left ventricle in terms of ventricular morphology, myocardial contractile pattern and special vulnerability to the pressure overload. Right ventricular failure (RVF) can be evaluated in terms of decreased RV contractility, RV volume overload, and/or RV pressure overload. The management for RVF starts from clear understanding of the pathophysiology of RVF. In addition to correction of the underlying disease, management of RVF per se is very important. Meticulous control of volume status, inotropic agents, vasopressors, and pulmonary selective vasodilators are the main tools in the management of RVF. The relative importance of each tool depends on the individual clinical status. Medical assist device and surgery can be considered selectively in case of refractory RVF to optimal medical treatment.

Clinical Experience of Open Heart Surgery - Report of 124 cases - (개심술 124예의 임상적 고찰)

  • Han, Gyun-In;Gwak, Yeong-Tae;Kim, Gi-Man
    • Journal of Chest Surgery
    • /
    • v.22 no.4
    • /
    • pp.638-647
    • /
    • 1989
  • From February 1985 to May 1989, 124 cases of cardiac surgery were performed under cardiopulmonary bypass at Dae-Jeon Eul-Ji General Hospital with the overall mortality of 8.06 We obtained relatively a higher mortality than other hospitals. The reasons are advanced disease status, inadequate preoperative diagnosis, lack of experience of surgeons in open heart surgery, lack of numbers and qualities of monitoring device and ventilator, and frequent migration of medico-surgical team. Most of the reasons are specific to the condition of the private hospital. The purpose of this article is going to make better preoperative and postoperative result by reviewing experienced cases with related articles.

  • PDF

Comprehensive understanding of atrial septal defects by imaging studies for successful transcatheter closure

  • Song, Jinyoung
    • Clinical and Experimental Pediatrics
    • /
    • v.57 no.7
    • /
    • pp.297-303
    • /
    • 2014
  • Transcatheter closure of atrial septal defects has become a popular procedure. The availability of a preprocedural imaging study is crucial for a safe and successful closure. Both the anatomy and morphology of the defect should be precisely evaluated before the procedure. Three-dimensional (3D) echocardiography and cardiac computed tomography are helpful for understanding the morphology of a defect, which is important because different defect morphologies could variously impact the results. During the procedure, real-time 3D echocardiography can be used to guide an accurate closure. The safety and efficiency of transcatheter closures of atrial septal defects could be improved through the use of detailed imaging studies.

Usability Study on Public Access Defibrillator (공공설치용 자동제세동기의 사용성 연구)

  • Oh, Young-Jin
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.32 no.1
    • /
    • pp.61-66
    • /
    • 2009
  • Usability study of the CU Medical "i-PAD" AED was conducted to validate the usability of the device, primarily focused on the trained user as well as the utility of the training material. Comparing these results of the trained participants to those obtained by Callejas et al. (2004), who studied video-trained users of two commercially available Philips AEDs (FR2 and HS1) using a male manikin only, the participants in this study were more successful (100% vs. 85.7%-FR2 vs. 88.9%-HS1) and faster to shock (58.5s-i-PAD vs. 91s-FR2 vs. 90s-HS1). While the focus of this study was on validating ease of use for trained bystanders, the results of the untrained condition showed that, from a usability perspective, these devices perform as well as any other AEDs already approved and available for purchase for untrained bystander use, as evidenced by the comparison to various published research results.