• Title/Summary/Keyword: cardiac approach

Search Result 184, Processing Time 0.025 seconds

A Systematic Review of Nursing Interventions in Patients with Extracorporeal Membrane Oxygenation (ECMO) (체외막산소공급(ECMO) 치료 환자의 간호 중재에 대한 체계적 고찰)

  • Su-Min Park;Guan-Woung Jo
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.3
    • /
    • pp.237-247
    • /
    • 2024
  • Purpose : This study aimed to systematically review the effectiveness of nursing interventions for patients receiving extracorporeal membrane oxygenation (ECMO). As the use of ECMO increases in critical care settings, it is important to understand how nursing interventions affect patient outcomes, survival, and complication rates. Methods : This systematic review followed the preferred reporting items for systematic reviews and meta-analysis guidelines. A literature search was performed using terms related to ECMO and nursing interventions in several international electronic databases including CINAHL, Embase, MEDLINE, and Web of Science. Studies were screened and selected according to predefined eligibility criteria, focusing on those that evaluated the impact of nursing interventions on adult. Data extraction and risk-of-bias assessment were independently performed by two researchers. Results : A total of 647 studies were identified, and seven met the inclusion criteria for qualitative analysis. The included studies demonstrated that high-quality nursing care significantly improves clinical outcomes and reduces complications in patients receiving ECMO. Effective nursing interventions included prone positioning combined with ECMO for patients with acute respiratory distress syndrome, meticulous infection control, comprehensive and continuous nursing protocols, skilled nursing, and multidisciplinary management. These interventions have been shown to improve oxygenation, reduce complications, such as bleeding, manage blood pressure, and enhance overall clinical outcomes. Conclusion : High-quality nursing interventions are critical to improve survival and reduce complications in patients receiving ECMO. Implementing a multidisciplinary approach and comprehensive nursing protocols, including infection control and psychological support, is essential for the effective management of these patients. The findings of this study provide a foundation for the development of practical guidelines and educational programs to improve the quality of care for patients undergoing ECMO, ultimately enhancing the effectiveness of ECMO treatment and patient outcomes.

Comparison of the Operative Results of Performing Endoscopic Robot Assisted Minimally Invasive Surgery Versus Conventional Cardiac Surgery (수술용 내시경 로봇(AESOP)을 이용한 최소 침습적 개심술과 동 기간에 시행된 전통적인 개심술의 결과에 대한 비교)

  • Lee, Young-Ook;Cho, Joon-Yong;Lee, Jong-Tae;Kim, Gun-Jik
    • Journal of Chest Surgery
    • /
    • v.41 no.5
    • /
    • pp.598-604
    • /
    • 2008
  • Background: The improvements in endoscopic equipment and surgical robots has encouraged the performance of minimally invasive cardiac operations. Yet only a few Korean studies have compared this procedure with the sternotomy approach. Material and Method: Between December 2005 and July 2007, 48 patients (group A) underwent minimally invasive cardiac surgery with AESOP through a small right thoracotomy. During the same period, 50 patients (group B) underwent conventional surgery. We compared the operative time, the operative results, the post-operative pain and the recovery of both groups. Result: There was no hospital mortality and there were no significant differences in the incidence of operative complications between the two groups. The operative $(292.7{\pm}61.7\;and\;264.0{\pm}47.9min$, respectively; p=0.01) and CPB times ($128.4{\pm}37.6\;and\;101.7{\pm}32.5min$, respectively; <0.01) were longer for group A, whereas there was no difference between the aortic cross clamp times ($82.1{\pm}35.0\;and\;87.8{\pm}113.5min$, respectively; p=0.74) and ventilator times ($18.0{\pm}18.4\;and\;19.7{\pm}9.7$ hr, respectively; p=0.57) between the groups. The stay on the ICU $(53.2{\pm}40.2\;and\;72.8{\pm}42.1hr$, respectively; p=0.02) and the hospitalization time ($9.7{\pm}7.2\;and\;14.8{\pm}11.9days$, respectively; p=0.01) were shorter for group A. The Patients in group B had more transfusions, but the difference was not significant. For the overall operative intervals, which ranged from one to four weeks, the pair score was significantly lower for the patients of group A than for the patients of group B. In terms of the postoperative activities, which were measured by the Duke Activity Scale questionnaire, the functional status score was clearly higher for group A compared to group B. The analysis showed no difference in the severity of either post-repair of mitral ($0.7{\pm}1.0\;and\;0.9{\pm}0.9$, respectively; p=0.60) and tricuspid regurgitation ($1.0{\pm}0.9\;and\;1.1{\pm}1.0$, respectively; p=0.89). In both groups, there were no valve related complications, except for one patient with paravalvular leakage in each group. Conclusion: These results show that compared with the median sternotomy patients, the patients who underwent minimally invasive surgery enjoyed significant postoperative advantages such as less pain, a more rapid return to full activity, improved cosmetics and a reduced hospital stay. The minimally invasive surgery can be done with similar clinical safety compared to the conventional surgery that's done through a median sternotomy.

Surgical Treatment of Acyanotic Tetralogy of Fallot (비청색성 팔로사징의 외과적 치료)

  • 천종록;전상훈;장봉현;이종태;김규태
    • Journal of Chest Surgery
    • /
    • v.31 no.8
    • /
    • pp.749-755
    • /
    • 1998
  • Background: Twelve patients with acyanotic tetralogy of Fallot(TOF), characterized by the combination of a malaligned ventricular septal defect(VSD) and infundibular pulmonic stenosis with the clinical finding of acyanosis at rest, underwent surgical correction between January 1988 and July 1997. Materials and methods: 9.92% of patients with the diagnosis of TOF were acyanotic TOF in the same period. Ages ranged from 12 to 42 months(mean 25.2 months). 2D-echocardiographic studies, cardiac catheterization, and angiocardiograms were performed in all patients before operation. The preoperative mean systemic arterial oxygen saturation was 93.5%. According to the 2D-echocardiographic analysis, there was Lt-to-Rt shunt through VSD in 4 patients, bidirectional shunt in 2 patients, and no shunt in 6 patients. Results: The preoperative mean right ventricle to pulmonary artery(RV-PA) pressure gradients were 52.3 mmHg on 2D- echocardiogram and 48.4 mmHg on cardiac catheterization. The repair of ventricular septal defect was performed through a right atrial approach and the hypertrophic infundibular muscle bundles were resected by the transatrial and transpulmonary approach. Six patients(50%) received a transannular patch. The mean cardiopulmonary bypass time was 135.0 minutes, and the aortic crossclamp time was 87.8 minutes. Postoperative complications included bleeding necessitating reentry in one and chylothorax in one. No patient died after operation and there were no late deaths. Postoperative 2D-echocardiograms revealed tiny patch dehiscence in 5 cases and a moderate RV-PA pressure gradients(mean 15.3 mmHg). All patients were in New York Heart Association functional class 1 after operation. Conclusions: acyanotic TOF is the uncommon form of TOF, and acyanotic TOF can be repaired with a good outcome.

  • PDF

Experimental Fetal Cardiopulmonary Bypass in the Fetal Lamb Model (태아양 모델을 이용한 실험적 태아 심폐우회술)

  • 이정렬;임홍국;김원곤;김종성;최정연;김용진
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.495-503
    • /
    • 1999
  • Background: We tested the technical feasibility of fetal cardiac bypass and collected baseline data on the fetal hemodynamics and placental functions related to the cardiopulmonary bypass in the fetal lamb model. Material and Method: Eleven fetuses at 120 to 150 days of gestation were subjected to bypass via trans-sternal approach with a 12 G pulmonary arterial cannula and 14 to 18 F venous cannula for 30 minutes. All ewes received general anesthesia with ketamine. In all the fetuses, no anesthetic agents were used except muscle relaxant. Eight served as a group in which placenta was excluded from the extracorporeal circulation by clamping the umbilical cord during the bypass(the oxygenator group) and in the remaining three, the placenta worked as the only source of oxygen supply(the placenta group). Observations were made every 10 minute during a 30-minute bypass and 30-minute post bypass period. No prostaglandin inhibitors were used both in ewes and in fetuses. Result: Weights of the fetuses ranged from 1.9 to 5.2 kg. In the oxygenator group, means of arterial pressure, PaO2, atrial pressure, heart rate, and bypass flow rate ranged 69.8 to 82.6 mmHg, 201.7 to 220.9 mmHg, 4.1 to 4.3 mmHg, 169 to 182/min, and 140.3 to 164.0 ml/kg/min, respectively during bypass, but rapid deterioration of the fetal cardiac functions and the placental gas exchange was observed after the cessation of bypass. In the placenta group, means of arterial pressure decreased from 44.7 to 14.4 mmHg and means of PaCO2 increased from 61.9 to 129.6 mmHg during bypass. Flow rate was suboptimal(74.3 to 97.0 ml/kg/min) during bypass. All hearts fibrillated immediately after the discontinuation of bypass. Conclusion: In this study, the technical feasibility of fetal cardiopulmonary bypass was confirmed in the fetal lamb model. However, further studies with modifications of the bypass including an addition of prostaglandin inhibitor, an application of the total spinal anesthesia on the fetus, a creation of more concise bypass circuit, and a use of active pump are mandatory to improve the outcome.

  • PDF

Surgical Technique for Korean Artificial Heart(AnyHeart) Implantation Using a Right Thoracotomy Approach (우측 개흉술을 이용한 한국형 인공심장(AnyHeart)의 이식기법)

  • Son. Ho-Sung;Sun, Kyung;Shin, Jae-Seung;Lee, Sung-Ho;Jung, Jae-Seung;Lee, Hye-Won;Kim, Kwang-Taik;Kim, Seung-Chul;Won, Yong-Soon;Min, Byoung-Goo;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.329-335
    • /
    • 2002
  • Background: The surgical technique for biventricular assist device(BVAD) implantation has mainly consisted of cannulation procedures. A median sternotomy has been the technique of choice as it gives a surgeon an excellent exposure of the heart. However, considering that most patients require a future sternotomy or already have a previous sternotomy, sternotomy-related complication remains a major concern in BVAD implantation. Based on this consideration as well as the clinical experiences of conventional heart surgery, the authors have hypothesized that the cardiac chambers for BVAD cannulation can be approached from the right side of the heart. The purpose of this studs to develop a novel surgical technique of right thoracotomy for BVAD implantation in an animals study. Material and Method: For last two years, 16 (11 calves, 3 canines, and 2 sheep) out of 30 experimental animals with AnyHeart implantation underwent a right thoracotomy. The device was used as an implantable BVAD in 14 animals, a wearable BVAD in 1, and an implantable LVAD in 1. The chest cavity was entered through the 4th intercostal space or the 5th periosteal bed. As for the BVAD use, a right inflow cannula was inserted into the right atrial free wall and a right outflow cannula was grafted onto the main pulmonary artery. A left inflow cannula was inserted into the interatrial groove and a left outflow cannula was grafted on the innominate artery of the ascending aorta. The connecting tubes were brought out through the thoracotomy wound and connected to the pump located in the subcutaneous pocket at the right flank. Result: Except for the 5 animals for a lilting test or during the early learning curve, all recovered smoothly from the procedures. The inflow drainage allowed the pump output 6.5 L/min at the maximum with 3-3.5 L/min in an average. Of the survivors, there noted no procedure-related mortality or morbidity. Necropsy findings demonstrated the well-positioned cannula tips in the each cardiac chamber

A Study on the Cardiopulmonary Resuscitation Methods in Ambulance (구급차 내에서의 심폐소생술 방법에 관한 연구)

  • Shin, So-Yeon;Kim, Jee-Hee;Kim, Gyoung-Yong;Kang, Shin-Woo;Bang, Sung-Hwan;Yun, Jong-Geun;Roh, Sang-Gyun
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.104-111
    • /
    • 2014
  • The purpose of this study is to investigate the CPR within ambulance. The Subjects were 890 emergency medical technicians in fire department in Gyeonggido. After continuing education program, the emergency medical technicians completed the questionnaires from January to February, 2012. Questionnaire consisted of demographic characteristics, method of chest compression (one handed or two handed), chest compression - ventilation ratio, and hands only CPR. Data were analyzed by frequency analysis and Chi-square test, t-test. One-way analysis of variance (ANOVA) was followed by Scheffe post-hoc test to analyze changes in all parameters between all groups. One handed chest compression accounted for 14.0% and two handed chest compression accounted for 86.0%. Hands only CPR accounted for 71.7% and standard CPR (30:2) accounted for 28.3%. In order to perform the high quality CPR, as least three persons must be dispatched in the ambulance. The flexible management of manpower may improve the survival from the cardiac arrest. A systemic approach for educating and training EMT's in CPR is needed.

Outcome of neonatal palliative procedure for pulmonary atresia with ventricular septal defect or tetralogy of Fallot with severe pulmonary stenosis: experience in a single tertiary center

  • Jo, Tae Kyoung;Suh, Hyo Rim;Choi, Bo Geum;Kwon, Jung Eun;Jung, Hanna;Lee, Young Ok;Cho, Joon Yong;Kim, Yeo Hyang
    • Clinical and Experimental Pediatrics
    • /
    • v.61 no.7
    • /
    • pp.210-216
    • /
    • 2018
  • Purpose: The present study aimed to evaluate progression and prognosis according to the palliation method used in neonates and early infants aged 3 months or younger who were diagnosed with pulmonary atresia with ventricular septal defect (PA VSD) or tetralogy of Fallot (TOF) with severe pulmonary stenosis (PS) in a single tertiary hospital over a period of 12 years. Methods: Twenty with PA VSD and 9 with TOF and severe PS needed initial palliation. Reintervention after initial palliation, complete repair, and progress were reviewed retrospectively. Results: Among 29 patients, 14 patients underwent right ventricle to pulmonary artery (RV-PA) connection, 11 palliative BT shunt, 2 central shunt, and 2 ductal stent insertion. Median age at the initial palliation was 13 days (1-98 days). Additional procedure for pulmonary blood flow was required in 5 patients; 4 additional BT shunt operations and 1 RV-PA connection. There were 2 early deaths among patients with RV-PA connection, one from RV failure and the other from severe infection. Finally, 25 patients (86%) had a complete repair. Median age of total correction was 12 months (range, 2-31 months). At last follow-up, 2 patients had required reintervention after total correction; 1 conduit replacement and 1 right ventricular outflow tract (RVOT) patch enlargements. Conclusion: For initial palliation of patients with PA VSD or TOF with severe PS, not only shunt operation but also RV-PA connection approach can provide an acceptable outcome. To select the most proper surgical strategy, we recommend thorough evaluation of cardiac anomalies such as RVOT and PA morphologies and consideration of the patient's condition.

Effects of Phosphodiesterase 5 Inhibition with Sildenafil on Atrial Contractile and Secretory Function

  • Quan, He Xiu;Kim, Sun-Young;Jin, Xuan-Shun;Park, Jong-Kwan;Kim, Sung-Zoo;Cho, Kyung-Woo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.10 no.3
    • /
    • pp.149-154
    • /
    • 2006
  • Selective inhibition of phosphodiesterase (PDE) 5 opened a new therapeutic approach for cardiovascular disorders. Therefore, the effect of PDE5 inhibition on the cardiac function should thoroughly be defined. The purpose of the present study was to define the effects of sildenafil, a selective inhibitor of PDE5, on the atrial cGMP efflux, atrial dynamics, and the release of atrial natriuretic peptide (ANP). By perfusing rabbit left atria to allow atrial pacing, changes in atrial stroke volume and pulse pressure, transmural extracellular fluid translocation, cGMP efflux, and ANP secretion were measured. SIN-I, an NO donor and soluble (s) guanylyl cyclase (GC) activator, and C-type natriuretic peptide (CNP), an activator of particulate (p) GC activator, were used. Sildenafil increased basal levels of cGMP efflux slightly but not significantly. Sildenafil in a therapeutic dose increased atrial dynamics (for atrial stroke volume, $2.84{\pm}1.71%$, n=12, vs $-0.71{\pm}0.86%$, n=21; p<0.05) and decreased ANP release ($-9.02{\pm}3.36%$, n=14, vs $1.35{\pm}3.25%$, n=23; p < 0.05), however, it had no effect on the SIN-1- or CNP-induced increase of cGMP levels. Furthermore, sildenafil in a therapeutic dose accentuated SIN-1-induced, but not CNP-induced, decrease of atrial pulse pressure and ANP release. These data indicate that PDE5 inhibition with sildenafil has a minor effect on cGMP levels, but has a distinct effect on pGC-cGMP- and sGC-cGMP-induced contractile and secretory function.

MR Technology to 4T

  • Vaughan, Thomas
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.103-105
    • /
    • 2003
  • After fifteen years of development, Magnetic Resonance (MR) technology for human imaging and spectroscopy is reaching a refined state with FDA approved 3T clinical products from Siemens, GE, and Philips. Broker has cleared CE approval with a 4T system. Varian supports a 4T system platform as well. Shielded magnets are standard at 3T from GE, Oxford, Magnex, and IGC. A shielded 4T whole body magnet is available from Oxford. Stronger switched gradients and dynamic shim coils, desired at any field, areespecially useful at higher static magnetic fields B0. In addition to the higher currents required for higher resolution slice or volume selection afforded by higher SNR, whole body gradient coils will be driven at increasing slew rates to meet the needs of new cardiac applications and other requirements. For example 3T and 4T systems are now being equipped with 2kV, 500A gradient coils and amplifiers capable of generating 4G/cm in 200msec, over a 67+/-cm bore diameter. High field EPI applications require oscillation rates at 1 kHz and higher. To achieve a benchmark 0.2 ppm shim over a 30cm sphere in a high field magnet, at least four stages of shimming need to be considered. 1) A good high field magnet will be built to a homogeneity spec. falling in the range of 100 to 150 ppm over this 30cm spherical "sweet spot" 2) Most modern high field magnets will also have superconducting shim coils capable of finding 1.5 ppm by their adjustment during system installation. 3) Passive ferro-magnetic shimming combined with 4) active, high order room temperature shim coils (as many as five orders are now being recommended) will accomplish 0.2 ppm over the 30cm sphere, and 0.1 ppm over a human brain in even the highest field magnets for human studies. Safety concerns for strong, fast gradients at any B0 field include acoustic noise and peripheral nerve stimulation. One or more of the mechanical decoupling methods may lead to quieter gradients. Patient positioning relative to asymmetric or short gradient coils may limit peripheral nerve stimulation at higher slew rates. Gradient designs combining a short coil for local speed and strength with a longer coil for coverage are being developed for 3T systems. Local gradients give another approach to maximizing performance over a limited region while keeping within the physiologically imposed dB0/dt performance limits.

  • PDF

P Wave Detection Algorithm through Adaptive Threshold and QRS Peak Variability (적응형 문턱치와 QRS피크 변화에 따른 P파 검출 알고리즘)

  • Cho, Ik-sung;Kim, Joo-Man;Lee, Wan-Jik;Kwon, Hyeog-soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.8
    • /
    • pp.1587-1595
    • /
    • 2016
  • P wave is cardiac parameters that represent the electrical and physiological characteristics, it is very important to diagnose atrial arrhythmia. However, It is very difficult to detect because of the small size compared to R wave and the various morphology. Several methods for detecting P wave has been proposed, such as frequency analysis and non-linear approach. However, in the case of conduction abnormality such as AV block or atrial arrhythmia, detection accuracy is at the lower level. We propose P wave detection algorithm through adaptive threshold and QRS peak variability. For this purpose, we detected Q, R, S wave from noise-free ECG signal through the preprocessing method. And then we classified three pattern of P wave by peak variability and detected adaptive window and threshold. The performance of P wave detection is evaluated by using 48 record of MIT-BIH arrhythmia database. The achieved scores indicate the average detection rate of 92.60%.