• Title/Summary/Keyword: carboxen

Search Result 20, Processing Time 0.027 seconds

Thermodynamic Studies on the Adsorption of 4-Octylphenol on Carboxen by GC/MS Analysis (GC/MS 분석에 의한 4-Octylphenol의 Carboxen 흡착에 대한 열역학적 연구)

  • Lee, Joon-Bae;Park, Woo-Yong;Shon, Shungkun;Jung, Ji Eun;Jeong, Yong Ae;Gong, Bokyoung;Kim, Yu-Na;Kwon, O-Seong;Paeng, Ki Jung
    • Applied Chemistry for Engineering
    • /
    • v.29 no.3
    • /
    • pp.356-361
    • /
    • 2018
  • It is common to analyze volatile organic compound (VOC) or semi-VOC (SVOC) in a sample composed of a complex matrix consisting of multiple components such as bloods through a separation process. Adsorption is a physical phenomenon in which certain components accumulate on the surface of other phases. In order to overcome difficulties in the pretreatment process, an adsorption is frequently used. Solid phase microextraction (SPME) equipment with porous carbon carboxen (CAR) is an example of adsorption application. In this study, the adsorption of 4-octylphenol to carboxen was examined. To do so, the extraction efficiency for such solvents as dichloromethane ($CH_2Cl_2$, DCM), ethylacetate ($CH_3COOC_2H_5$, EA) and diethylether ($C_2H_5OC_2H_5$, $Et_2O$) was studied and also the derivatization reaction for 4-octylphenol with reagents of bistrimethylsilyltrifluoroacetamide (BSTFA), methylchloroformate (MCF) and pentafluorobenzylbromide (PFBBr) was compared. The combination of DCM and BSTFA showed good performance thus they were adopted for this study. Thermodynamic adsorption experiments showed that the adsorption process was endothermic and Freundlich isotherm equation was more suitable than Langmuir isotherm. It was also found that the adsorption followed a pseudo-$2^{nd}$ order kinetic model.

A Study on the Performance Optimization of a Continuous Monitoring Method for Hazardous VOCs in the Ambient Atmosphere (환경대기 중 유해성 VOC에 대한 자동연속 측정방법의 성능 최적화에 관한 연구)

  • Son, Eun-Seong;Seo, Young-Kyo;Lee, Dong-Hyun;Lee, Min-Do;Han, Jin-Seok;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.6
    • /
    • pp.523-538
    • /
    • 2009
  • Recently, there has been a keen demand for real-time automatic monitoring of VOCs not only in Korea but other developed countries. We carried out this study to evaluate and to optimize the performance of a continuous automatic monitoring system for hazardous VOCs (HVOCs) in the ambient atmosphere, using an on-line GC system. The online system normally consisted of a Nafion dryer prior to a cold trap of an automatic thermal desorption apparatus and a GC system equipped with two detectors, i.e. PID and ECD. Preliminary tests conducted to check out any contamination of the system revealed an evidence of significant artifact formation of benzene, and it was found that the Nafion dryer (even brand new one) is the source of the benzene artifact. Thus, all the subsequent experiments in this study was carried out inevitably by removing the Nafion dryer. The on-line GC method was investigated with a variety of QC/QA performance criteria such as repeatability, linearity, lower detection limits, and accuracy. In order to find out the best operating condition for the on-line GC system, three different types (in terms of adsorption strength) of cold trap combinations were tested, i.e. (i) Tenax-TA and Carbopack-B combination (weak and hydrophobic); (ii) Tenax-TA, Carbopack-X and Carboxen-1000 combination (strong and hydrophilic); and (iii) Tenax-TA and Carbopack-X combination (medium and hydrophobic/hydrophilic). The USEPA TO-17 manual method was selected as a reference method to evaluate the performance of the on-line method. A series of experiments revealed that the system performance was superior to others when a cold trap packed with hydrophilic adsorbents (Tenax-TA/Carbopack-X/Carboxen-1000 combination) was used and operated at $25^{\circ}C$. However, the system with a cold trap packed with a combination of Tenax-TA and Carbopack-X is more recommended for field applications since the carboxen-1000 adsorbent is too sensitive to water vapor, and hence the performance of the system might be very unstable to humid samples or during rainy days. Furthermore, the precision and accuracy criteria of the Tenax-TA/ Carbopack-X combination were generally compatible with the triple adsorbents cold trap. The continuous automatic monitoring method is, thus, considered very useful to real-time monitoring to understand the variations of VOCs concentrations in ambient air, as it adopts much simpler procedures in sampling, analysis, and data integration steps than manual monitoring methods. However, it should be noted that there is a high possibility of benzene artifacts formation through the Nafion dryer, which is often installed to remove water vapor in air samples before being adsorbed onto the cold trap. Therefore, if a Nafion dryer is used in any studies of monitoring VOCs, the benzene contamination should be carefully examined before carrying out obtaining the data.

A Study on the Improvement Repeatability and Accuracy of the Analysis Method for SF6 of Trace Level (극미량 수준의 SF6 측정법에 따른 재현성 및 정확도 향상에 관한 연구)

  • Yoo, Heejung;Choe, Hongwoo;Lee, Sepyo;Kim, Jongho;Han, Sangok;Ryoo, Sangboom
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.523-530
    • /
    • 2018
  • Kyoto Protocol, adopted in 1997, set the obligation to reduce $CO_2$, $CH_4$, $N_2O$, HFCs, PFCs, and $SF_6$ in developed countries during 1st promised period. $SF_6$ has been drawing a lot of attention since the Kyoto Protocol because once it is released into the atmosphere, it not only stays in the atmosphere for more than 3,200 years but also emits 22,800 times stronger global warming potential at the same concentrations as $CO_2$ if remains in the atmosphere for 100 years. This study introduces 12 methods for $SF_6$ of measuring trace. $SF_6$ of trace level in the atmosphere correctly, the measurement method was changed and as a result, when the back flush method was applied to the pre-concentration system that used low-temperature concentration and high-temperature desorption system, which used Carboxen-1000 adsorption trap, the effect was the best.

Analysis of Volatile Organic Compounds in Water by Modified Injection Mode for Purge & Trap-GC/MS Method (Purge & Trap-GC/MS 분석법의 주입방식 개선에 의한 물 중의 휘발성 유기물 분석)

  • Jeon, Chi Wan;Lee, Sang Hak;Eum, Chul Hun
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.8
    • /
    • pp.635-642
    • /
    • 1995
  • Improved sample introduction system has been investigated for the determination of volatile organic compounds in water using a purge & trap preconcentration apparatus and a capillary gas chromatography/mass spectrometry. The present limitations associated with the moisture control module and cryorefocusing system suggested by EPA were discussed. To solve the problems such as improper separation of peaks due to the adsorption of water and contamination of purge & trap system, a more efficient connection system between the purge & trap apparatus and the gas chromatograph was introduced and the optimum operational conditions were suggested. A carbopack B/carboxen 1000 and 1001 trap was used for the purge & trap procedure and a custom made crosslinked dimethyldiphenylpolysiloxane capillary column was used for the separation of compounds. Accuracy and precision of the method suggested in this report were examined and the method detection limit of each compound was proposed for the simultaneous determination of 54 volatile organic compounds in water.

  • PDF

Analysis of Haloacetic Acids in Drinking Water by Direct Derivatization and Headspace-SPME Technique with GC-MS (Handspace Solid Phase Microextraction 방법에 의한 HAAs 분석에 관한 연구)

  • Cho, Deok-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.638-648
    • /
    • 2004
  • In many drinking water treatment plants, chlorination process is one of the main techniques used for the disinfection of water. This disinfecting treatment leads to the formation of haloacetic acid (HAAs). In this study, headspace solid-phase microextraction (HS-SPME) was studied as a possible alternative to liquid-liquid extraction for the analysis of HAAs in drinking water. The method involves direct derivatization of the acids to their methyl esters without methyl tert-butyl ether (MTBE) extraction, followed by HS-SPME with a $2cm-50/30{\mu}m$ divinylbenzene/carboxen/polydimethylsiloxane fiber. The effects of experimental parameters such as selection of SPME fiber, the volume of sulphuric acid and methanol, derivatization temperature and time, the addition of salts, extraction temperature and time, and desorption time on the analysis were investigated. Analytical parameters such as linearity, repeatability and limit of detection were also evaluated. The $2cm-50/30{\mu}m$-divinylbenzene/carboxen/polydimethylsiloxane fiber, sulphuric acid of 1ml, methanol of 3ml, derivatization temperature of $50^{\circ}C$ derivatization time of 2hrs, sodium chloride salt of 10g, extraction time of 30 minutes, extraction temperature of $20^{\circ}C$ and desorption time of 1 minute at $260^{\circ}C$ were selected as the optimal experimental conditions for the analysis of HAAs. The linearities ($r^2$), relative standard deviations (%RSD) and limits of detection (LOD) for HAAs were 0.9978~0.9991, 1.1~9.8% and $0.05{\sim}0.2{\mu}g/l$, respectively.

Analysis of Volatile Compounds in Perilla frutescens var. acuta by Solid Phase Microextraction (SPME에 의한 소엽의 향기성분 분석)

  • Chung, Mi-Sook;Lee, Mie-Soon
    • Journal of the Korean Society of Food Culture
    • /
    • v.18 no.1
    • /
    • pp.69-74
    • /
    • 2003
  • This study was conducted to find the appropriate fiber for extraction of volatile compounds from Perilla frutescens var. acuta. by solid phase microextraction (SPME). Two SPME fiber, carboxen/polydimethylsiloxane (CAR/PDMS) and polydimethylsiloxane (PDMS) were used to determine the selectivity of the fibers to the different flavor compounds present in the Perilla frutescens var. acuta. Thirty-nine compounds were identified in the volatile compounds extracted by CAR/PDMS fiber, including 6 aldehyde, 1 alcohol, 10 hydrocarbons, 17 terpene hydrocarbons, 2 ketones and 3 benzenes. In PDMS fiber, 3 aldehydes, 2 alcohols, 13 terpene hydrocarbons and 2 miscellaneouses were identified. Perillaldehyde was found to be major volatile flavor component of fresh Perilla frutescens var. acuta. Perillaldehyde and terpene hydrocarbons were more identified in PDMS fiber. These results suggested that the selectivity of PDMS fiber was better than that of CAR/PDMS fiber in Perilla frutescens var. acuta..

Analysis of Volatile Compounds in Elsholtzia splendens by Solid Phase Microextraction (SPME에 의한 꽃향유의 휘발성 향기성분 분석)

  • 정미숙;이미순
    • Korean journal of food and cookery science
    • /
    • v.19 no.1
    • /
    • pp.79-82
    • /
    • 2003
  • Volatile compounds in Elsholtzia splendens were extracted by solid phase microextraction (SPME). Two kinds of SPME fiber, carboxen/polydimethylsiloxane (CAR/PDMS) and polydimethylsiloxane (PDMS) were used to determine the selectivity of the fibers to the different flavor compounds present in the Elsholtzia splendens. Identification of volatile compounds was based on the linear retention indices (RI) and the comparison of their mass spectra with those of on-computer library. Thirty compounds were identified in the volatile compounds extracted by CAR/PDMS fiber, including 1 aldehyde, 5 alcohols, 3 hydrocarbons, 17 terpene hydrocarbons, 3 ketones and 1 miscellaneous. And 5 alcohols, 3 hydrocarbons, 18 terpene hydrocarbons, 3 ketones and 2 miscellaneouses were identified in PDMS fiber. These results suggested that the selectivity of PDMS fiber was similar to that of CAR/PDMS fiber in Elsholtzia splendens. The major volatile compounds were naginataketone and elsholtziaketone in Elsholtzia splendens.

Simultaneous determination of 37 volatile organic compounds at ng/L concentration level in surface water by HS-SPME-GC/MS (HS-SPME-GC/MS에 의한 지표수에서 ng/L 농도 수준의 37개 휘발성유기화합물의 동시 분석)

  • Kim, Tae-Seung;Hong, Suk-Young;Kim, Jong-Eun;Lim, Hyun-Hee;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.39-49
    • /
    • 2012
  • A method to detect 37 volatile organic compounds (VOCs) in surface water was described based on headspace solid-phase micro extraction and gas chromatography-mass spectrometry. VOCs in water were vaporized for 30 min at 40 $^{\circ}C$ in a headspace vial and adsorbed on 85 ${\mu}m$ carboxen-polydimethylsiloxane. Under the established condition, the lowest quantification limit was 4.1-96 ng/L by using 4.0 mL water sample, and the relative standard deviation was less than 15% at concentrations of 0.05 and 0.50 ${\mu}g/L$. The detection limits meet lower concentration than 1/10 of the water quality criteria for VOCs established by the US EPA or Germany. The LOQ is a sensitivity which the monitoring for the establishing water quality criteria requires. When the proposed method was used to analyze the target compounds in sixteen surface water samples and total 16 VOCs were detected in surface water samples collected from Gum-River. Maximum concentrations of VOCs detected were not exceeded the EPA or Germany guidelines in any of the samples.

Evaluation of TVOC contribution from Raw materials of PVC wallpaper using the Headspace-SPME-GC/MS (HS-SPME-GC/MS 법을 이용한 PVC벽지 원자재의 TVOC 기여도 평가)

  • Jang, Mi-Ok;Jeong, Tak-Kyo;Jeong, Yung-Rim;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.488-495
    • /
    • 2007
  • A wallpaper having many surfaces in indoor is composed of various raw materials. In this study, TVOC contribution from raw materials of PVC wallpaper was evaluated by using headspace-solid phase microextraction (HS-SPME)-GC/MS. Samples were diluent, resin stabilizer, plasticizer, filler, blowing agent and PVC resin. 9 mL of each sample was put into 22 mL glass vial and they were equilibrated for 1 hour at $100^{\circ}C$. Headspace in vial was absorbed to $75{\mu}m$ Carboxen-PDMS fiber and analyzed by GC/MS. Aromatic compounds like a toluene, ethylbenzene and xylene, ketones compounds like a acetone, methoxyacetone and 2-butanone and alkane compounds like a nonane decane and undecane were identified from raw materials. And alcohol compounds like a ethanol and butanol and aldehydes were detected. TVOC emission of diluent, resin stabilizer, plasticizer, PVC resin, blowing agent and filler were $54.20{\mu}g/g$, $32.88{\mu}g/g$, $0.50{\mu}g/g$, $0.88{\mu}g/g$, $0.22{\mu}g/g$ and $0.11{\mu}g/g$, respectively. Contribution of TVOC emission of diluent, resin stabilizer and PVC resin that were concerned about add ratio were 0.708, 0.129, 0.115, respectively. In conclusion, it's necessary to reduce TVOC emission through improvement of diluent, resin stabilizer and PVC resin. Also, HS-SPME-GC/MS method which was developed in this study will be used for raw materials analysis effectively.

Analysis of Haloacetonitriles in Drinking Water Using Headspace-SPME Technique with GC-MS (Handspace Solid Phase Microextraction 방법에 의한 HANs 분석에 관한 연구)

  • Cho, Deok-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.628-637
    • /
    • 2004
  • In many drinking water treatment plants, chlorination process is one of the main techniques used for the disinfection of water. This disinfecting treatment leads to the formation of disinfection by-products (DBPs) such as haloacetonitriles (HANs), trihalomethanes (THMs), haloacetic acids (HAAs). In this study, headspace-solid phase microextraction (HS- SPME) technique was applied for the analysis of HANs in drinking water. The effects of experimental parameters such as selection of SPME fiber, the addition of salts, magnetic stirring, extraction temperature, extraction time and desorption time on the analysis were investigated. Analytical parameters such as linearity, repeatability and detection limits were also evaluated. The $50/30{\mu}m$-divinylbenzene/carboxen/polydimethylsiloxane fiber, extraction time of 30 minutes, extraction temperature of $20^{\circ}C$ and desorption time of 1 minute at $260^{\circ}C$ were the optimal experimental conditions for the analysis of HANs. The correlation coefficients ($r^2$) for HANs was 0.9979~0.9991, respectively. The relative standard deviations (%RSD) for HANs was 2.3~7.6%, respectively. Detection limits (LDs) for HANs was $0.01{\sim}0.5{\mu}g/L$, respectively.