• 제목/요약/키워드: carbonized

검색결과 390건 처리시간 0.023초

Detection of the Ultrasonic Signals due to Partial Discharges in a 154kV Transformer

  • Kweon, Dong-Jin;Chin, Sang-Bum;Kwak, Hee-Ro
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제2C권6호
    • /
    • pp.297-303
    • /
    • 2002
  • We have developed an on-line ultrasonic detector to monitor partial discharge in an operating transformer. The ultrasonic sensor has 150[KHz] resonance frequency and contains a pre-amplifier with 60[㏈] gain. The on-line ultrasonic detector has 50~300[KHz] frequency band-pass filter to remove electrical and mechanical noises from the transformer. This detector has an ultrasonic signal discrimination algorithm which discriminates ultrasonic signals due to partial discharge in a transformer. A moving average method of ultrasonic signal number was employed to effectively monitor the increasing trend of the partial discharge. This paper describes an experience of partial discharge detection in a 154[㎸] operating transformer using an ultrasonic detector. With regards to gas analysis in oil, C2H2 gas was produced with a warning level in this transformer We detected ultrasonic signals on the transformer steel wall, and estimated the position of partial discharge. With further inspection, we found carbonized marks due to partial discharge on the supporting bolt which fastens the windings.

Biomorphic C/SiC 복합재료의 기계적 물성 연구 (Prediction of Mechanical Property of Biomorphic Composites)

  • 정재연;우경식;이동주;홍순형;김연철
    • 한국항공우주학회지
    • /
    • 제40권8호
    • /
    • pp.670-677
    • /
    • 2012
  • 본 논문에서는 Biomorphic C/SiC 복합재료에 대하여 단위구조해석을 수행하였다. 소나무와 뉴송을 탄화하고 실리콘을 함침해 제조한 복합재료의 미세조직을 사각배열과 육각배열로 가정해 단위구조를 정의하고 등가물성치를 계산하였다. 단위구조의 크기가 동일하지 않은 경우도 고려하였고, 또한 공극의 배열에 따른 물성치의 변화를 몬테카를로 시뮬레이션을 통해 조사하였다.

오염된 절연재료의 트래킹 특성에 관한 연구 (A Study on the Tracking Characteristics of Contaminated Insulating Materials)

  • 옥경재;이춘하
    • 한국화재소방학회논문지
    • /
    • 제21권3호
    • /
    • pp.97-103
    • /
    • 2007
  • 본 실험은 오염된 절연재료의 트래킹 특성을 연구하였다. 오염된 절연재료의 트래킹에 의한 절연파괴 특성 분석은 IEC 60112를 통하여 수행하였다. 연구결과, 오염된 절연재료의 트래킹 특성은 다음과 같다. (a) 오염된 절연재료의 경우 정상시료 보다 비교트래킹지수(comparative tracking index, CTI)가 낮게 나타났다. (b) 오염된 절연재료의 최초 탄화흔 발생시간 및 탄화도전로 형성 시간이 정상시료 보다 빠르게 나타났다.

변압기의 고장검출을 위한 유중 코로나 특성 연구 (Transformer diagnosis using characteristics of corona in Oil)

  • 권태원;곽희로;김재철;김응상;박민규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1989년도 추계학술발표회논문집
    • /
    • pp.65-70
    • /
    • 1989
  • This paper presents resarch results on the use of a corona detector and a pulse counter in order to diagnose for oil transformers. Using these experimental apparatus, tests were carried out on a typical transformer oil containing different carbonized paper and various moisture contents to measure the picocoulomb val-ues and pulse count. Through the result of this study it was found that the picocoulomb values and pulse count of corona were depended on the getting stained in transformer oil. The amplitude of the partial discharge amount and the number of pulse were decreased up to 70 [。c] and then was increased as the oil temperature goes up. It was concluded that the determinati-on level for diagnosis of oil transform-er was taken into account the temperatu-er of transformer oil, The use of pulse counter method, which have been taken the same property of voltage and temperature variation for the corona measurement mothod, considera-bly increase insulator avilability.

  • PDF

열처리 피치를 사용한 탄소성형체의 산화안정화 (The Oxi-stabilization of Carbon Precursor Using Heat Treated Pitch)

  • 조광연;김경자
    • 한국세라믹학회지
    • /
    • 제40권10호
    • /
    • pp.985-990
    • /
    • 2003
  • 콜타르 피치를 450∼50$0^{\circ}C$로 가열하여 메조페이스 피치를 제조하였다. 열처리된 피치는 시편의 부풀림과 변형을 줄이기 위해 공기 중 160∼24$0^{\circ}C$로 산화안정화하였다. 고온열처리핏치를 이용한 부피를 가진 성형체의 산화안정화 원리를 조사하기 위해 열중량감소, FT-IR을 측정하였다. 부피를 가진 성형체에 대한 산화안정화의 영향은 쇼아경도, 곡강도를 측정하여 파악하였다.

부분 방전에 의한 실리콘 케이블의 열화 특성에 관한 연구 (A Study on Degradation Properties of Silicone Cable due to Partial Discharge)

  • 이성일
    • 한국전기전자재료학회논문지
    • /
    • 제28권1호
    • /
    • pp.34-39
    • /
    • 2015
  • In this study, the characteristics of partial discharge was measured for the four core silicone cable (0.6/1.0 kV, $1.0SQ{\times}4C$) with insulated part of 15 cm and conductor of 1cm. The following results have been confirmed as a result of this study. When the first line of cable is connected to the positive electrode and the second, third line of cable is connected to the negative electrode, it found that the inception voltage and extinction voltage decreased with increasing the line of negative electrode, and the partial discharge charge quantity(Q) increases, while the number of discharge occurrence has decreased. The inception voltage and extinction voltage of partial discharge has decreased with increasing the degradation rate in the 33%, 67%, 100%. Also, it confirmed that the partial discharge charge quantity(Q) and the number of discharge occurrence has decreased.

계면특성이 전력케이블 열화에 미치는 영향 (Interfacial Effects on the Aging of Power Cables)

  • 한재홍;이동영;김상준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 C
    • /
    • pp.1393-1395
    • /
    • 1997
  • In order to investigate the interfacial effects on the aging of power cables, we analyzed recently failed cables using characterization techniques. In this study, some cables showed a convolution which can cause the concentration of electric field and carbonized impurities at the surface of insulation. Also there is a relation between the degree of cross- linking and volume resistivity. From the hot oil test, the sites of water tree and void coincided with each other.

  • PDF

Hydrogen storage capacity of highly porous carbons synthesized from biomass-derived aerogels

  • Choi, Yong-Ki;Park, Soo-Jin
    • Carbon letters
    • /
    • 제16권2호
    • /
    • pp.127-131
    • /
    • 2015
  • In this work, highly porous carbons were prepared by chemical activation of carbonized biomass-derived aerogels. These aerogels were synthesized from watermelon flesh using a hydrothermal reaction. After carbonization, chemical activation was conducted using potassium hydroxide to enhance the specific surface area and microporosity. The micro-structural properties and morphologies were measured by X-ray diffraction and scanning electron microscopy, respectively. The specific surface area and microporosity were investigated by $N_2$/77 K adsorption-desorption isotherms using the Brunauer-Emmett-Teller method and Barrett-Joyner-Halenda equation, respectively. Hydrogen storage capacity was dependent on the activation temperature. The highest capacity of 2.7 wt% at 77 K and 1 bar was obtained with an activation temperature of $900^{\circ}C$.

Electrochemical Behaviors of PAN/Ag-based Carbon Nanofibers by Electrospinning

  • Park, Soo-Jin;Im, Se-Hyuk
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권4호
    • /
    • pp.777-781
    • /
    • 2008
  • In this work, silver nanoparticles-containing polyacrylonitrile (PAN) solutions in N,N-dimethylformamide (DMF) were electrospun to be webs consisting of nanofibers. The inputted voltage and PAN content in the solution were fixed at 15 kV and 10 wt.% in DMF with 10 cm of tip-to-collector distance (TCD). The PAN/Ag nanofiber webs were stabilized by oxidation at 250 ${^{\circ}C}$ for 2 h in air and carbonized at 1000 ${^{\circ}C}$ for 2 h in $N_2$. The resultant diameter distribution and morphologies of the nanofibers were evaluated by scanning electron microscope analysis. The electrochemical behaviors of the nanofiber webs were also observed by cyclic voltammetry tests. It was found that the presence of silver nanoparticles in carbon nanofiber webs led to the increase of specific capacitance and the decrease of fiber diameters.

저온탄화처리 폐가구재로 제조한 재생보드의 물성 (Properties of Recycled Board Made of Disused Wooden Furniture Carbonized at Low Temperature)

  • 서인수;이민경;이화형;강호양
    • 농업과학연구
    • /
    • 제36권1호
    • /
    • pp.19-25
    • /
    • 2009
  • This study was carried for recycling laminated PB and MDF of disused furniture. PB and MDF particles taken from disused furniture were heat-treated at $250^{\circ}C$ and four levels of treatment time, 2, 4, 6 and 8 hours. The recycled boards were made with heat-treated particles after milling and screening with 100 mesh. The bending strength of the recycled boards were lower than that of virgin boards while their anti-swelling efficiency were much improved. Their formaldehyde emissivity were very low. Thus it was concluded that the recylcled boards are prospective environment-friendly material for interial consturction.

  • PDF