• Title/Summary/Keyword: carbon waste

Search Result 932, Processing Time 0.024 seconds

Study on liquid carbonation using the recycling water of ready-mixed concrete (레미콘회수수를 이용한 액상탄산화에 관한 연구)

  • Lim, Yun-Hui;Lee, Ju-Yeol;Choi, Chang-Sik;Hong, Bum-Ui;Park, Jin-Won;Lee, Dae-Young;Park, Byung-Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.770-778
    • /
    • 2013
  • In this study, a liquid carbonation method was applied for producing precipitate calcium carbonate by liquid-liquid reaction. We recycled the recycling water of ready-mixed concrete, one of construction waste for use source of carbonate ion. A supernatant separated from the recycling water of ready-mixed concrete, as a result of ICP analysis of a cation, $Ca^{2+}$ was contained up to 1100 ppm. We used MEA as a $CO_2$ absorbent for the liquid carbonation. A precipitate $CaCO_3$ was produced at more than MEA 20 wt%. The precipitate $CaCO_3$ as a final product was separated and dried. The result of XRD was confirmed the generation of $CaCO_3$ to calcite structure.

Combination of air stripping and biological processes for landfill leachate treatment

  • Smaoui, Yosr;Bouzid, Jalel;Sayadi, Sami
    • Environmental Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.80-87
    • /
    • 2020
  • Landfill waste decomposition generates a dark effluent named, leachate which is characterized by high organic matter content. To minimize these polluting effects, it becomes necessary to develop an effective landfill leachate treatment process. The objective of this study was to evaluate the performance of an innovative approach based on air stripping, anaerobic digestion (AD) and aerobic activated sludge treatment. A reduction of 80% of ammonia and an increase of carbon to nitrogen ratio to 25 were obtained, which is a suitable ratio for AD. This latter AD was performed in fixed bed reactor with progressive loading rate that reached 2 and 3.2 g COD/L/d for the raw and diluted leachate (1:2), respectively. The anaerobic treatment led to significant removal of chemical oxygen demand (COD) and biogas production, especially for the diluted leachate. The COD removal was of 78% for the raw leachate and a biogas production of 4 L/d with 70% methane content. The use of the diluted leachate led to 81% of COD removal and 7 L/d biogas with 75% methane content. It allowed a removal of 77% COD and more than 97% of the organic compounds present in the initial leachate sample.

Improvement Directions for the G-SEED System from the Resident's Perspective - Focused on Certification Assessment Criteria for Apartment Buildings -

  • Choi, Yeo Jin;Lhee, Sang Choon
    • KIEAE Journal
    • /
    • v.14 no.4
    • /
    • pp.19-26
    • /
    • 2014
  • The building section is providing immediate causes for global climate change problems since it takes about 50% of carbon emission, 20~50% of waste discharge, 33% of energy consumption, 40% of resource use, and 17% of water consumption. So, many countries over the world have developed and implemented green building certification systems to assess sustainable performances of buildings since the early 1990s. In korea, the green building certification system to induce the diffusion of sustainable buildings was first introduced in 2002 and developed as an improved version of the G-SEED(Green Standard for Energy and Environmental Design) system in 2013 after major revisions of related legislations. This research conducts a survey targeting residents on an apartment building that was certified as green building and examines the importance of assessment criteria on apartment buildings to certify green buildings using the Analytic Hierarchy Process(AHP) method. And it proposes a new direction on certification assessment standards from the resident's prospective. As a result, assessment criteria such as indoor environment, ecological environment, energy & environment pollution, and maintenance management among 7 main ones turned out important on assessing the G-SEED system for apartment buildings, while criteria such as material & resource, water circulation management, and land use & transportation did relatively unimportant.

Production of Soluble Crude Protein Using Cellulolytic Fungi on Rice Stubble as Substrate under Waste Program Management

  • Vibha, Vibha;Sinha, Asha
    • Mycobiology
    • /
    • v.33 no.3
    • /
    • pp.147-149
    • /
    • 2005
  • The investigation was undertaken to enhance the decomposition process by pre-treatment of rice stubble, having higher concentration of lignin. Air-dried rice stubble was treated with 1.8 liter of 1% NaOH and autoclaved. Six cellulolytic fungi, Trichoderma harzianum, Penicillium citrinum, Curvularia lunata, Aspergillus flavus and Alternaria alternata were grown in basal synthetic medium along with delignified rice-residue as carbon source for production of soluble crude protein. Though the loss of cellulose has been observed by all of them but having a considerable status in the presence of T. harzianum and T. harzianum yielded highest percentage of crude protein (27.99%) with biomass of 375 mg, whereas the lowest protein value (17.91%) was recorded in case of A. niger with biomass of 422 mg. Among the imperfect fungi, T. harzianum was the most potent. Effects of incubation period and nitrogen sources on soluble crude protein production by T. harzianum were also undertaken in this study. Fifth day of incubation period and potassium nitrate as nitrogen source among other nitrogen sources was found most appropriate for soluble crude protein production by the mentioned organism.

A Study on the Correlation of Organic Factors in Municipal Waste Water (도시하수중 유기인자의 상호기관에 관한 연구)

  • 황상용;손종열;우완기
    • Journal of Environmental Health Sciences
    • /
    • v.16 no.2
    • /
    • pp.55-61
    • /
    • 1990
  • Laboratory methods commonly used today are biochemical oxygen demand, chemical oxygen demand, and total organic carbon. Establishment of constant relationships among the various measures of organic content depends primarily on the nature of the wastewater and its source. Of all the measures, the most difficult to correlate to the others is the BODs test, because of the problems associated with biological tests. The results were summarized as follwos, 1. For typical municipal wastes, however, the SBOD$_{5}$/SCOD$_{cr}$ ratio varies from 0.14 to 0.34(mean 0.21), SBOD$_{5}$/STOC ratio varies from 0.35 to 1.19(mean 0.69) 2. Correlation analysis between the SBOD$_{5}$ and SCOD$_{cr}$ gave good correlation coefficient r = 0.903 and the equation Y = 3.756X + 16,221 was obtained. 3. The correlation between the SBOD$_{5}$ and STOC was well presented with equation : Y = 1,070X + 7,637, and also correlation coefficient r = 0.821 4. The correlation between the SCOD$_{cr}$ and STOC was well presented with equation : Y = 0.256X +5.513 and also correlation coefficient r = 0.816. 5. Because of the rapidity with which the TOC test can be conducted, it is anticipated that more use will be made of these tests in the future.

  • PDF

금속 이온을 이용한 Bacillus Stearothermophilus 호열성 단백질 분해효소의 역가 향상 및 호열 ${\cdot}$ 호기성 소화공정에의 응용

  • Kim, Yeong-Gi;Bae, Jin-Hye;Lee, Won-Hong;Choe, Jeong-U
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.167-170
    • /
    • 2000
  • Proteolytic hydrolysis is one of the main enzymatic reaction of waste activated sludge (WAS) digestion. Pretense excreted from Bacillus stearothermophilus (ATCC 31197) showed optimum temperature of $75^{\circ}C$ for maxium heat stable proteolytic activity against azo casein. The dependency of $Ca^{2+}$, $Zn^{2+}$ on heat stability of proteolytic enzymes were measured with various concentrations. It was shown that $Ca^{2+}$ ion enhanced heat stability of these enzymes. Then thermophilic aerobic digestion (TAD) was performed using B. sterothermophilus with the addition of divalent ions. Performance of TAD process with ATCC 31197 activated by $Ca^{2+}$, $Zn^{2+}$ions in terms of dissolved organic carbon (DOC) concentration, extracellular protein concentration, and scanning electrion microscopy (SEM) analysis. The best result of protein reduction concentration in digestion test was obtained with the addition of 2 mM $Ca^{2+}$ ion.

  • PDF

Electrical Conductivity of Dielectric on WEDM Characteristics (WEDM 가공특성에 대한 방전액의 전기전도율의 영향)

  • Kim, Chang-Ho;Yeo, Hong-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.10
    • /
    • pp.1800-1808
    • /
    • 2003
  • This work deals with the electrical conductivity of dielectric on output parameters such as metal removal rate and surface roughness value of a carbon steel(SM25C) and sintered carbides cut by wire-electrical discharge machining(W-EDM). Dielectric has several functions like insulation, ionization, cooling, the removal of waste metal particles. The presence of minute particles(gap debris) in spark gap contaminates and lowers the breakdown strength of dielectric. And it is considered that too much debris in spark gap is generally believed to be the cause of arcing. Experimental results show that increases of cobalt amount in carbides affects the metal removal rate and worsens the surface quality as a greater quantity of solidified metal deposits on the eroded surface. Lower electrical conductivity of the dielectric results in a lower metal removal rate because the gap between wire electrode and workpiece reduced. Especially, the surface characteristics of rough-cut workpiece and wire electrode were analyzed too. Debris were analyzed also through scanning electron microscopy(SEM) and surface roughness tester. Micro cracks and some of electrode material are found on the workpiece surface by energy dispersive spectrometer(EDS).

Some Physical and Chemical Properties of Carbonized Wood Wastes(II)

  • Kim, Byung-Ro;Mishiro, Akiyoshi
    • Journal of the Korean Wood Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.6-15
    • /
    • 1998
  • A total of forty five-ply, 30- by 30-cm lauan and larch plywood sheets were manufactured in the laboratory using commercial urea and phenol resin adhesives; half of these sheets were treated with fresh concrete. Each sheet was carbonized for 2, 4, and 6hours at $400^{\circ}C$, $600^{\circ}C$, and $750^{\circ}C$, respectively, and their physical properties were measured. The yie1d of charcoal decreased as carbonization temperature and time increased. Charcoal yield was greater in plywood than in veneer, and slightly greater in plywood treated with concrete compared to untreated plywood. Plywood manufactured with phenol resin adhesive had higher pH, higher equilibrium moisture content (EMC), and greater adsorption of methylene-blue dye compared to plywood manufactured with urea resin. For concrete-treated plywood, pH was greater than 10 even when the sheets were carbonized for 2hours at $400^{\circ}C$. Although the EMC of the phenol resin plywood was higher than that of the urea resin plywood, EMC of the phenol resin was lower than that of the urea resin. The larch phenol resin plywood that was carbonized for 6 hours at $750^{\circ}C$ adsorbed more methylene-blue than did the commercia1 wood-based activated charcoal as a result of total pore volume and surface area.

  • PDF

Advances on heat pump applications for electric vehicles

  • Bayram, Halil;Sevilgen, Gokhan;Kilic, Muhsin
    • Advances in Automotive Engineering
    • /
    • v.1 no.1
    • /
    • pp.79-104
    • /
    • 2018
  • A detailed literature review is presented for the applications of the heat pump technologies on the electric vehicles Heating, Ventilation and Air Conditioning (HVAC) system. Due to legal regulations, automotive manufacturers have to produce more efficient and low carbon emission vehicles. Electric vehicles can be provided these requirements but the battery technologies and energy managements systems are still developing considering battery life and vehicle range. On the other hand, energy consumption for HVAC units has an important role on the energy management of these vehicles. Moreover, the energy requirement of HVAC processes for different environmental conditions are significantly affect the total energy consumption of these vehicles. For the heating process, the coolant of internal combustion (IC) engine can be utilized but in electric vehicles, we have not got any adequate waste heat source for this process. The heat pump technology is one of the alternative choices for the industry due to having high coefficient of performance (COP), but these systems have some disadvantages which can be improved with the other technologies. In this study, a literature review is performed considering alternative refrigerants, performance characteristics of different heat pump systems for electric vehicles and thermal management systems of electric vehicles.

Machining Characteristics of WEDM due to Electrical Conductivity of Dielectric (방전액의 전도율의 변화에 따른 와이어방전가공의 가공특성)

  • Kim, Chang-Ho;Kang, Jae-Won
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.6
    • /
    • pp.15-21
    • /
    • 2006
  • This work deals with the electrical conductivity of dielectric on output parameters such as metal removal rate and surface roughness value of a carbon steel(SM25C) and sintered carbides cut by wire electrical discharge machining (WEDM). Dielectric has several functions like insulation, ionization, cooling, the removal of waste metal particles. The presence of minute metal particles(debris) in spark gap contaminates and lowers the breakdown strength of dielectric. And it is considered that too much debris in spark gap is generally believed to be the cause of arcing. Experimental results show that increases of cobalt amount in carbides affects the metal removal rate and worsens the surface quality as a greater quantity of solidified metal deposits on the eroded surface. Lower electrical conductivity of the dielectric results in a lower metal removal rate because the gap between wire electrode and workpiece reduced. Especially, the surface characteristics of rough-cut workpiece and wire electrode were analyzed too. Debris were analyzed also through scanning electron microscopy(SEM) and surface roughness tester. Micro cracks and some of electrode material are found on the workpiece surface by energy dispersive spectrometer(EDS).