• 제목/요약/키워드: carbon monoxide gas

검색결과 373건 처리시간 0.028초

Pressure Swing Adsorption 기반 수소정제용기 3차원 모델링 및 타당성 검증 연구 (Pressure Swing Adsorption Based Hydrogen Purification Vessel 3D Modeling and Feasibility Study)

  • 차요한;최재유;주현철
    • 한국수소및신에너지학회논문집
    • /
    • 제32권4호
    • /
    • pp.197-204
    • /
    • 2021
  • Pressure swing adsorption is a purification process which can get pure hydrogen. The purification process is composed of four process: compression, adsorption, desorption and discharge. In this study the adsorption process was simulated by using the Fluent and validated with experimental results. A gas used in experiment is composed of H2, CO2, CH4, and CO. Adsorption process conducted under 313 kelvin and 3 bar and bituminous-coal-based (BPL) activated carbon was used as the adsorbent. Langmuir model was applied to explain the gas adsorption. And diffusion of all the gases was controlled by micro-pore resistances. The result shows that, the most adsorbed gas was carbon dioxide, followed by methane and carbon monoxide. And carbon monoxide took the least amount of time to reach the maximum adsorption amount. The molar fraction of the off-gas became the same as the molar fraction of the gas supplied from the inlet after adsorption reached the equilibrium.

건축물내 일산화탄소 경보기 설치기준에 관한 연구 (A Study on the Standard for Installation of Carbon Monoxide Detector in a Building)

  • 강승규;최경석
    • 한국가스학회지
    • /
    • 제12권4호
    • /
    • pp.1-7
    • /
    • 2008
  • 최근 5년간 국내 가스사고 중 CO중독사고는 사망 36명, 부상 79명이 발생하였으며, 전체 가스 사고에 비해 인명피해율이 8배나 높게 나타나고 있다. 이러한 CO중독사고의 대부분이 노후 가스보일러 및 다중 가스 사용시설의 배기통 불량에 의한 가스누출사고로 조사되고 있다. 본 연구에서는 실험을 통해 건축물 내 보일러실의 배기통 불량에 의한 CO가스의 누출확산 메커니즘을 해석하였다. 배기통에서 누출된 CO 가스는 건축물 내부의 천정부근에서 가장 높은 농도분포를 보인다. 또한 CO경보기 설치 실험을 통해서 천정부근의 CO경보기가 가장먼저 작동하고, $30{\sim}40$분 경과한 후에 바닥 및 중간에 설치된 경보기가 작동하는 것을 확인하였다. 본 연구를 통해 CO경보기의 적정 설치위치를 확인하였으며, 이 결과를 토대로 건출물내 CO경보기 설치위치를 제안하였다.

  • PDF

Carbon Monoxide Sensor Based on a B2HDDT-doped PEDOT:PSS Layer

  • Memarzadeh, R.;Noh, Hui-Bog;Javadpour, S.;Panahi, F.;Feizpour, A.;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권8호
    • /
    • pp.2291-2296
    • /
    • 2013
  • An efficient carbon monoxide (CO) sensor was developed based on poly(3,4-ethylenedioxy)thiophenepoly(styrenesulfonate) (PEDOT:PSS) modified with a new pyrimidine-fused heterocyclic compound, bis(2-hydroxyphenyl)dihydropyrido[2,3-d:6,5-d]dipyrimidine-tetraone (B2HDDT). B2HDDT remains stable in the polymer matrix through interactions with functional groups of the polymer. It created prominent sites that captured CO gas, and the experimental parameters, including the amount of doped B2HDDT in the PEDOT:PSS film, were optimized. The sensor probe was also examined to verify its reliability for detecting CO in the presence of atmospheric gases in a discriminating manner. NMR, AFM, and FT-IR spectra were obtained to evaluate the structure and morphology of the B2HDDT-doped PEDOT:PSS (PEDOT:PSS/B2HDDT) film. The content of 35 vol % B2HDDT (7.0 mM) in PEDOT:PSS provided the largest response factor (${\Delta}R/R_o$) for the CO gas. The sensor response was reproducible, with a relative standard deviation < 5% (n = 5). The detection limit was determined to be $0.44{\pm}0.05$ vol %.

1 kW급 가정용 연료개질기 성능 최적화 (Performance optimization of 1 kW class residential fuel processor)

  • 정운호;구기영;윤왕래
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.731-734
    • /
    • 2009
  • KIER has been developed a compact and highly efficient fuel processor which is one of the key component of the residential PEM fuel cells system. The fuel processor uses methane steam reforming to convert natural gas to a mixture of water, hydrogen, carbon dioxide, carbon monoxide and unreacted methane. Then carbon monoxide is converted to carbon dioxide in water-gas-shift reactor and preferential oxidation reactor. A start-up time of the fuel processor is about 1h and CO concentration among the final product is maintained less than 5 vol. ppm. To achieve high thermal efficiency of 80% on a LHV basis, an optimal thermal network was designed. Internal heat exchange of the fuel processor is so efficient that the temperature of the reformed gas and the flue gas at the exit of the fuel processor remains less than $100^{\circ}C$. A compact design considering a mixing and distribution of the feed was applied to reduce the reactor volume. The current volume of the fuel processor is 17L with insulation.

  • PDF

수소 수율 증가를 위한 합성가스의 수성가스전환 반응 연구 (Water Gas Shift Reaction Research of the Synthesis Gas for a Hydrogen Yield Increase)

  • 김민경;김재호;김우현;이시훈
    • 신재생에너지
    • /
    • 제5권2호
    • /
    • pp.9-14
    • /
    • 2009
  • Automobile Shredder Residue (ASR) is very appropriate in a gasification melting system. Gasification melting system, because of high reaction temperature over than $1,350^{\circ}C$, can reduce harmful materials. To use the gasification processes for hydrogen production, the high concentration of CO in syngas must be converted into hydrogen gas by using water gas shift reaction. In this study, the characteristics of shift reaction of the high temperature catalyst (KATALCO 71-5M) and the low temperature catalyst (KATALCO 83-3X) in the fixed - bed reactor has been determined by using simulation gas which is equal with the syngas composition of gasification melting process. The carbon monoxide composition has been decreased as the WGS reaction temperature has increased. And the occurrence quantity of the hydrogen and the carbon dioxide increased. When using the high temperature catalyst, the carbon monoxide conversion ratio ($1-CO_{out}/CO_{in}$) rose up to 95.8 from 55.6. Compared with average conversion ratio from the identical synthesis gas composition, the low temperature catalyst was better than the high temperature catalyst.

  • PDF

이동식 적외선 가스히터의 배기가스현상에 대한 실험적 연구 (Experimental Study on the Flue Gas Phenomena in Infrared Mobile Heaters)

  • 김영규;류근준
    • 한국안전학회지
    • /
    • 제11권3호
    • /
    • pp.119-125
    • /
    • 1996
  • The experimental work is performed to obtain content levels and characteristics of flue gas in infrared mobile heaters for butane gas with varying the chamber size and its room temperature. The results showed that the oxygen depletion sensor device is operated at 18.3% of oxygen content. And the relation of oxygen content and carbon dioxide content in an enclosed space show linear aspect, but the content rate of carbon monoxide occurs at random without the level of oxygen content and carbon dioxide content.

  • PDF

일개 병원에서의 일산화탄소 중독증으로 내원한 환자에 대한 분석 (Analysis of Patients with Acute Carbon Monoxide Poisoning in one Hospital)

  • 김경환;김아진;신동운;노준영
    • 대한임상독성학회지
    • /
    • 제3권1호
    • /
    • pp.27-32
    • /
    • 2005
  • Purpose: The frequency of carbon monoxide poisoning has been decreased in the interior of the Korea. But occasionally it is occurred and the risk of exposure is high in working place so far. Because of the characteristics of gas, the detection of exposure and poisoning could be delayed and fatality is high. We should apprehend of carbon monoxide poisoning. So we would report analysis of patients with carbon monoxide poisoning. Methods: A retrospective review of CO poisoned patients visited emergency department from January 2000 to December 2004 was conducted. Results: 24 patients were enrolled. Their average of age was $37.6\pm20.9$ years old and COHb was $19.4\pm13.32\%$. The blood level of initial COHb and mental status on arrival were not correlated each other. The blood level of initial COHb and loss of consciousness were not correlated, too. Initial electrocardiography (EKG) was not correlated with cardiac enzymes such as CK-MB and troponin I. But base excess was correlated with mental status on arrival and complication such as rhabdomyolysis. Hyperbaric oxygen therapy was correlated with base excess and mental status on arrival. Conclusion: The clinical features of carbon monoxide poisoning are nonspecific. For proper diagnosis, it is important that we should consider patient's environment and take patient's history carefully. The blood level of initial COHb does not reflect severity of poisoning accurately. So We should determine the treatment of choice depending on patient's status.

  • PDF

촉매반응에 의한 연탄 연소가스로부터 일산화탄소의 제거 (제1보) (Removal of Carbon Monoxide from Anthracite Flue Gas by Catalytic Oxidation (I))

  • 정기호;이원국
    • 대한화학회지
    • /
    • 제20권5호
    • /
    • pp.431-437
    • /
    • 1976
  • 연탄 연소가스중의 일산화탄소와 산소 사이의 반응을 몇가지 촉매에 대해 조사했다. 이산화망간, 산화 동 및 그 혼합촉매를 사용하였으며, 그 실효반응 온도(effective reaction temperature)는 각각 다음과 같다. 즉, $MnO_2$ 단독촉매 및 30% $MnO_2$-70% CuO 혼합촉매는 $250^{\circ}C,\;CuO$$450^{\circ}C$, 50% $MnO_2$-50% CuO는$200^{\circ}C$, 70% $MnO_2$-30% CuO는$180^{\circ}C$였다. 실효반응온도 이하에서 일산화탄소의 산화율은 일산화 탄소의 농도가 증가함에 따라 감소하는 경향을 보였으며, 실효반응 온도 이상에서는 변화가 없었다. 반응기 내 체재시간은 0.9 ∼ 1.8초의 범위 내에서는 일산화탄소 산화반응에 조금도 영향을 주지 않았다.

  • PDF

산화촉매에 의한 자동차 배출가스중 HC 및 CO의 정화에 관한 실험적 연구 (An experimental study on emission control of HC and CO due to oxidizing catalyst)

  • 한영출;최규훈
    • 오토저널
    • /
    • 제3권1호
    • /
    • pp.46-53
    • /
    • 1981
  • This paper describes emission control of hydrocarbon and carbon-monoxide due to oxidizing catalyst. The experiment was performed on a precious metal pelleted catalyst(Pt). The factors of the efficiency for purification due to oxidizing catalyst are space velocity, temperature, composition of exhaust gas and supplementary air. The experiment was carried out to control the factors of efficiency for purification. The results of experimental study show that temperature of catalytic converter, supplementary air and space velocity affected the efficiency for purification of hydrocarbon and carbon monoxide.

  • PDF

외부 유입 가스 조절을 통한 연료전지 구동 성능 안정화 (An Experimental Guide to Predictable Fuel Cell Operations by Controlling External Gas Supply)

  • 장한샘;박영은;이재영
    • 공업화학
    • /
    • 제29권5호
    • /
    • pp.626-629
    • /
    • 2018
  • 연료전지는 높은 연료유연성을 갖고 있어, 탄소 및 탄화수소 등을 통해서도 전기를 생산할 수 있다. 하지만 이러한 연료원을 사용한 경우, 불안정한 장기 구동성능이 종종 관측된다. 본 연구에서는 반응기 내부에 존재하는 탄화수소가 장기 구동성능을 불안정하게 함을 밝힌다. 본 연구진은 비활성기체인 아르곤을 이용하여 산화극 반응기 내부의 가스화경로를 예측하고, 이를 통해 탄화수소의 영향을 억제하여 불안정한 장기 구동성능을 극복한다. 더 나아가, 산화극 반응기 내부에 이산화탄소를 공급하여 역부드아반응을 유도한다. 역부드아반응을 통해 탄소연료전지에서 연료로 사용될 수 있는 일산화탄소를 만들어낸다. 과도한 이산화탄소의 주입은 오히려 연료손실 등의 문제를 야기함을 확인한다. 따라서, 본 연구에서는 이산화탄소 공급량의 최적화가 중요함을 밝히고, 이를 통해 연료전지 구동 성능을 안정화한다.