• Title/Summary/Keyword: carbon monoxide gas

Search Result 372, Processing Time 0.026 seconds

A Study on Analysis of Greenhouse Gas Emissions from Forest Fires Depending on Region and Altitude (지역 및 고도별 산불로부터 온실가스 배출량 분석 연구)

  • Park, Young-Ju;Lee, Hae-Pyeong
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.182-188
    • /
    • 2012
  • In this study we analyzed carbon emissions of leaves of a Pinus densiflora which is vulnerable to a forest fire using the cone calorimeter in order to analyze greenhouse gas emissions from forest fires depending on region and altitude. Fuels were collected from 9 regions[Hongcheon(Gangwon-do), Chungsong(Gyeongbuk-do), Yanhpyeong (Gyeonggi-do), Jecheon(Chungchongbuk-do), Gongju(Chungcheongnam-do), Wuju(Jeollabuk-do), Youngam(Jeollanam-do), Busan and Jeju-do)] and 9 altitudes(80 m, 450 m, 900 m, 1000 m, 1100 m, 1200 m, 1300 m, 1400 m and 1500 m) and then, carbon dioxide and carbon monoxide emissions contained in a weight of 50 g of fuel were analyzed. According to the results, there were differences in carbon emissions by regional groups, as the average carbon dioxide and carbon monoxide emissions in 9 regions were nearly 43.5929 g to 52.8868 g, and 0.8842 g to 3.6422 g, respectively. Busan and Jecheon had relatively higher carbon dioxide emissions and especially, Busan had 1.23 times higher carbon dioxide emissions than Jeju-do. Also, Gongju, Chungcheongnamo Province and Busan had relatively higher carbon monoxide emissions and especially, Gongju and Pusan had relatively higher carbon monoxide emissions and especially, Gongju had 4.12 higher carbon monoxide emissions than Hongcheon. In addition, there were differences in carbon emissions too depending on altitude, since carbon dioxide and carbon monoxide emissions in 9 altitudes were respectively, 40.7015 g to 68.9297 g and 1.3923 g to 12.2918 g. At the altitude of 80m, carbon dioxide and carbon monoxide emissions were respectively, 68.9297 g and 12.2918 g, and at the altitude of 450m, carbon dioxide and carbon monoxide emissions were respectively, 65.5115 g and 11.2497 g. These results show that pine trees at the lower altitude discharge relatively more carbon. It is considered that this analysis on carbon emissions depending on region and altitude can be effectively used for predicting greenhouse gas emissions and establishing statistical data from forest fires in each region and altitude.

Combustion Emission Gas Analysis and Health Hazard Assessment about P. densiflora and Q. variabilis Surface Fuel Beds (소나무, 굴참나무 낙엽의 연소 방출가스 분석 및 건강 위험성 평가)

  • Kim, Dong-Hyun;Kim, Eung-Sik;Lee, Myung-Bo
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.24-31
    • /
    • 2009
  • Based on fallen leaves of major Korean conifer species 'Pinus densiflora' and major Korean broadleaved species 'Quercus variabilis', this study sought to identify combustion emission gas types and measure their concentration by means of FTIR (Fourier Transform Infrared) spectrometer. As a result, it was found that there were total 13 types of combustion gas detected from fallen leaves of Pinus densiflora and Quercus variabilis, such as carbon monoxide, carbon dioxide, acetic acid, butyl acetate, ethylene, methane, methanol, nitrogen dioxide, ammonia, hydrogen fluoride, sulfur dioxide and hydrogen bromide. Notably, nitrogen monoxide was additionally detected from fallen leaves of Quercus variabilis. It was found that the overall concentration of combustion gas emitted from the fallen leaves of Pinus densiflora was 4.5 times higher than that from fallen leaves of Quercus variabilis. Particularly, it was found that emission concentration of some combustion emission gas types like carbon monoxide, carbon dioxide and butyl acetate exceeded the upper limit of their time-weighted average (TWA, ppm), while the emission concentration of carbon monoxide and carbon dioxide exceeded their short-term exposure limit (STEL, ppm) for both species. Thus, it was found that carbon monoxide and carbon dioxide have higher hazard to health than other gas types, because these two gas types account for higher than 99% of overall gas emission due to combustion of surface fire starting from litter layer in forest.

Derivation of Optimal Design Variables Considering Carbon Monoxide Emission Characteristics of Commercial Gas Stove Burners (업소용 가스레인지 버너의 일산화탄소 배출 특성을 고려한 최적 설계변수 도출)

  • Il Kon Kim;Taehoon Kim
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.1
    • /
    • pp.1-8
    • /
    • 2024
  • Commercial gas stoves feed primary air to the burner and burn the fuel-air mixture in a partially premixed combustion. This mechanism produces carbon monoxide during combustion. In this study, design parameters of a commercial gas stove were optimized by considering the carbon monoxide emission. Gas consumption rate, carbon monoxide emission, and water boiling temperature as a heating performance were determined. Carbon monoxide emission was measured using a Korean Industrial Standards standard collector. Water boiling temperature was measured by first soaking the pot in water for approximately 10 min and then heating the pot filled with water. A thermocouple was installed inside the pot. Carbon monoxide increased as the nozzle diameter was increased and the burner-pot height was decreased. This result was due to the insufficient mixing between the fuel and air. Heating performance was enhanced when the nozzle diameter was increased and the burner-pot height was decreased. However, the heating performance deteriorated when the nozzle diameter was 1.8 mm and the burner-pot height was reduced to 50 mm. This phenomenon was due to the formation of a flame on the side of the pot. A merit factor was defined to find the optimal design parameters to satisfy gas consumption rate, carbon monoxide emission, and heating performance. Optimal design values were established to be a nozzle diameter of 1.5 mm and a burner-pot height of 60 mm.

Analysis of Mechanism for Diffusion of Incomplete Combustion Gas Released from Domestic Gas Boiler (가정용 보일러의 불완전연소가스 누출확산 메커니즘 해석)

  • Kang, Seung-Kyu;Choi, Kyung-Suhk;Yoon, Joon-Yong
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2868-2873
    • /
    • 2008
  • Carbon Monoxide(CO) poisoning accident is higher than any other gas accident in the rate of deaths/incidents. In the last five years, 36 people died and 104 were wounded because of carbon monoxide poisoning accident. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of incomplete combustion gas(CO) released from leakage hole of exhaust tube was analyzed by computational flow modeling and concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling and formed the circular currents along the walls. Through these experiments and simulation, the reasonable installation location of carbon monoxide alarm was made certain and suggested.

  • PDF

A Method to Prevent CO Poisoning from Instantaneous Water Heaters (순간 가스온수기의 CO 중독사고 예방에 관한 연구)

  • Ahan, Jeong-Jin;Yeo, Chang-Hoon;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.3
    • /
    • pp.26-30
    • /
    • 2011
  • Instantaneous water heater being not properly installed and not adequately maintained may produce fatal accidents due to carbon monoxide poisoning and suffocation. Insufficient supply of air into the gas appliance for complete burning of the fuel or blocking the outlet of the combustion gas could be a cause to increase carbon monoxide concentration in the exhaust gas of the gas appliance. In this work, the experiments are done with a collected instantaneous water heater using in domestic and the concentration of oxygen near the gas appliance and carbon monoxide in exhaust gas are observed to investigate the risk of instantaneous water heater. The concentration of oxygen near the gas appliance is reduced until 17.7% for the ratio of the ventilation area and floor area being 3.5%. If the outlet of combustion gas is blocked, the carbon monoxide concentration is steeply increasing more than 4,000ppm. Therefore, periodic checking the outlet of combustion gas is more important than vent area to reduce the risk of carbon monoxide poisoning.

Selective Sensing of Carbon Monoxide Gas in CuO banded ZnO Ceramics (CuO띠가 입혀진 ZnO 소결체의 일산화탄소에 대한 선택적 감지 특성)

  • 신병철
    • Journal of the Korean Ceramic Society
    • /
    • v.30 no.10
    • /
    • pp.819-822
    • /
    • 1993
  • The purpose of this paper is a investigation of sensing mechanism for the carbon monoxide gas in CuO infiltrated ZnO ceramics. Potential barriers between CuO and ZnO can explain the selective sensing of carbon monoxide gas in the physically contacted CuO/ZnO ceramics. A specimen having no potential barrier between CuO and ZnO was prepared to see whether the gas sensing mechanism is related to the potential barrier. CuO and ZnO was prepared to see whether the gas sensing mechanism is related to the potential barrier. CuO was painted on the non electrode sides of ZnO ceramics. The CuO painted ZnO ceramics showed that the sensitivityfor the carbon moxnoxide gas was 1.3 times as high as that for the hydrogen gas. It is almost same gas sensitivity as that of the CuO infiltrated ZnO ceramics.

  • PDF

Carbon Monoxide Gas Carburization Behavior of Molybdenum Materials

  • Hieda, Koji;Nagae, Masahiro;Yoshio, Tetsuo;Takada, Jun;Hiraoka, Yutaka;Takida, Tomohiro
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1159-1160
    • /
    • 2006
  • For pure Molybdenum carburized in mixed gases of argon and carbon monoxide, microstructural observations were carried out. X-ray diffraction analysis for carburized specimens revealed that brittle ${\alpha}-Mo_2C$- layer hardly formed in the case of low carbon monoxide concentration. Fracture strength of the specimen carburized at 1673 K for 16 h is about 550 MPa higher than that of the un-carburized specimen. SEM observation revealed that with increasing carburizing temperature, the region demonstrating a transgranular fracture mode progressed towards the center of specimen. This result means that the grain boundaries were strengthened by the grain boundary diffusion of carbon and the strength of grain boundaries exceeded that of grain itself.

  • PDF

Combustible Gas and Visible Distance by Sprinkler Head for Safety of Gymnasium Workers

  • Ahn, Jae-Cheon;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • v.10 no.3
    • /
    • pp.232-244
    • /
    • 2021
  • This study analyzed the changes in carbon monoxide, carbon dioxide, oxygen and visual distance by presence of sprinkler heads and their types in the event of a fire in an indoor gymnasium. Based on carbon monoxide and visual distance that affects human bodies enormously, first, if there is no sprinkler head, carbon monoxide will reach 0.4% within five seconds and visual distance rapidly shrank within five seconds. Seconds, in the event of standard sprinkler heads, carbon monoxide gradually increased from 30 seconds onwards and visual distance rapidly shrank after five seconds. Second, Third, if there are special sprinkler heads, carbon monoxide fluctuated after opening the head and visual distance became 5m or below from 15 seconds. Finally, in the event of early response sprinkler heads, carbon monoxide fluctuated up and down at 3 seconds due to falling water drops. Visual distance shrank up to 5m or below at 6 seconds. In the future, time for operation of each sprinkler head shall be analyzed.

EXPERIMENTAL AND COMPUTATIONAL PREDICTION OF CONCENTRATION OF CARBON MONOXIDE GAS RELEASED FROM EXHAUST TUBE OF GAS BOILER (가스보일러 배기통 이탈에 의한 CO가스 누출확산 실험 및 수치해석)

  • Kang, Seung-Kyu;Choi, Kyung-Suhk;Yoon, Joon-Yong
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.172-175
    • /
    • 2008
  • In the last five years, 45 people died and 104 were wounded because of carbon monoxide poisoning accident. CO poisoning accident is higher than any other gas accident in the rate of deaths/incidents. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of CO gas released from leakage hole of exhaust tube was analyzed by computational flow modeling and concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling and formed the circular currents along the walls. Through these experiments and simulation, the reasonable installation location of CO alarm was made certain and suggested.

  • PDF

A Study on Carbon monoxide Gas Sensing Characteristics of Pt-SiC Schottky Diode Schottky Diode (Pt-SiC 쇼트키 다이오드를 이용한 CO Gas 감지 특성에 대한 연구)

  • Nho, I.H.;Lee, J.H.;Yang, S.J.;Jang, S.W.;Kim, C.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.90-92
    • /
    • 2001
  • Carbon monoxide-sensing behavior of Pt-SiC Schottky diodes. fabricated on the same SiC substrate have been systematically compared and analyzed as a function of carbon monoxide concentrati on and temperature by I-V and ${\Delta}I$-t methods under steady-state and transient condition. Adsorption activation energies of Carbon monoxide on the surface of Pt-SiC Schottky diodes is investigated in a high temperature range ($100{\sim}500^{\circ}C$). The optimal temperature for behavior sensing is $300^{\circ}C$ and saturation concentration is 200 ppm.

  • PDF