• Title/Summary/Keyword: capturing device

Search Result 72, Processing Time 0.024 seconds

Measurement of Static and Dynamic Displacement by Image Processing and Study for Prediction Method of Velocity and Acceleration (영상처리를 이용한 정적·동적 변위 계측과 속도·가속도 추산방식 연구)

  • Heo, Seok;Lee, Bum-Ho;Jang, Il-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.2
    • /
    • pp.112-119
    • /
    • 2011
  • This paper is concerned with the measurement of static and dynamic displacement by image processing(IP) and study for prediction method of velocity and acceleration. To measure the displacement visually, the measurement system consists of a telephoto zoom camera, CCD(charge coupled device) image device and a computer. The specific target on the white board is used to calculate the displacement of the structure. The captured image is then converted into a pixel-based data and then analyzed numerically. The limitation of the system depends on the image capturing speed and the pixel-size of image. In this paper, we developed for the displacement measurement using the image processing method. The proposed method enables us to measure the vibration displacement, velocity and acceleration directly without any contact. The current resolution for the displacement measurement can be seen from the results.

Magnetic Wireless Motion Capturing System and its Application for Jaw Tracking System and 3D Computer Input Device

  • Yabukami, S.;Arai, K.;Arai, K.I.;Tsuji, S.
    • Journal of Magnetics
    • /
    • v.8 no.1
    • /
    • pp.70-73
    • /
    • 2003
  • We have developed a new tracking system of jaw movement. The system consists of two permanent NdFeB magnets and 32 elements of two-axial fluxgate sensor array, The two magnets are attached to head portion and front tooth. This system does not need any attachments of the head portion or mouth such as clutch or magnetic field sensor except magnets. The proposed system is applicable for five degree of freedom. Position accuracy within 2]m was achieved. We developed a 3D computer input device by using the above mentioned technique.

Smart device research for the prevention of missing child (미아 방지용 스마트 디바이스 구현에 관한 연구)

  • Ahn, Jong-Chan;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.437-440
    • /
    • 2007
  • Recently embedded system developed a lot. Physically, embedded systems range from portable devices such as digital watches and MP3 players, to large stationary installations like traffic lights, factory controllers, or the systems controlling nuclear power plants. This paper focuses on implementation of portable device which is applicable to the child-kidnap or missing child prevention system in residential area or public area. To be specific, this device is to transmit video data which comes from the camera in the device into the host PC via WLAN. Embedded hardware platform consists of s3c2440 with ARM9 core, WindowsCE OS and other sensors. OS enables the platform to do multitasking jobs which are handling GPS data, taking video, capturing audio via microphone in the device and transfer all kind of realtime data to the host PC.

  • PDF

The Design of Abstract Layer for Motion Capture System (모션캡처 시스템을 위한 추상레이어의 설계)

  • Lee, Hee-Man
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.1 s.45
    • /
    • pp.25-32
    • /
    • 2007
  • In this paper, the abstract layer for motion capture system is designed and implemented to meet the various hardware and different capturing method. The abstract layer can offer the unified programming by providing device independent API(Application Programming Interface). The device drivers of the optical system and mechanical system are emulated to verify the designed abstract layer. The optical system employs the AOA Ole while the mechanical system uses BVH file. An application program is written to call the abstract layer functions to drive both optical and mechanical drivers and receive the frame data, simulated motion data, that are displayed sequentially on the computer screen by utilizing Direct3D.

  • PDF

4S-Van: A Prototype Mobile Mapping System for GIS

  • Lee, Seung-Yong;Kim, Seong-Baek;Choi, Ji-Hoon;Lee, Jong-Hun
    • Korean Journal of Remote Sensing
    • /
    • v.19 no.1
    • /
    • pp.91-97
    • /
    • 2003
  • The design of Graphic Information System(GIS) in various applications is suffering from the difficulty of data acquisition, which is labor-intensive and time consuming. In order to provide the spatial data rapidly and accurately, 4S-Van, a prototype mobile mapping system, has been developed. The 4S-Van consists of 1)Global Positioning System(GPS), Inertial Navigation System(INS) for estimating the geographic position and attitude of the moving van, i.e.,(x, y, z) and the direction of the Van, 2) Charge Coupled Device(CCD) camera and laser scanner for capturing images and for measuring depth from geographic objects, and 3) External Synchronization Device(ESD) and industrial PC for synchronizing data from GPS/INS/CCD camera and for storing the data. In this paper, we present the design and implementation of the proto-Dpe 4S-Van system for spatial data acquisition for various GIS applications.

Camera Self-Calibration from Two Ellipse Contours in Pipes

  • Jeong, Kyung-Min;Seo, Yong-Chil;Choi, Young-Soo;Cho, Jai-Wan;Lee, Sung-Uk;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1516-1519
    • /
    • 2004
  • A tele-operated robot should be used to maintain and inspect nuclear power plants to reduce the radiation exposure to the human operators. During an overhaul of the nuclear power plants in Korea, a ROV(Remotely Operated Vehicle) may enter a cold-leg connected to the reactor to examine the state of the thermal sleeve and it's position in the safety injection nozzle. To measure the positions of the thermal sleeve or scratches from the video images captured during the examination, the camera parameters should be identified. However, the focal length of the CCD camera could be increased to a close up of the target and the aspect ratio and the center of the image could also be varied with capturing devices. So, it is desired to self-calibrated the intrinsic parameters of the camera and capturing device with the video images captured during the examination. In the video image of the safety injection nozzle, two or more circular grooves around the nozzle are shown as ellipse contours. In this paper, we propose a camera self-calibration method using a single image containing two circular grooves which are the greatest circles of the cylindrical nozzle whose radius and distance are known.

  • PDF

Measurement of Static and Dynamic Displacement by Image Processing and Study for Prediction Method of Velocity and Acceleration (영상처리를 이용한 정동적 변위 계측과 속도, 가속도 추산방식 연구)

  • Heo, Seok;Kwak, Moon-Kyu;Lee, Ho-Bum
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.527-532
    • /
    • 2010
  • This paper is concerned with the measurement of static and dynamic displacement by image processing(IP) and study for prediction method of velocity and acceleration. To measure the displacement visually, the measurement system consists of a telephoto zoom camera, ccd image device and a computer. The specific target on the white board is used to calculate the displacement of the structure. The captured image is then converted into a pixel-based data and then analyzed numerically. The limitation of the system depends on the image capturing speed and the pixel-size of image. In this paper, we developed for the displacement measurement using the image processing method. The proposed method enables us to measure the vibration measurement, velocity and acceleration directly without any contact. The current resolution of the displacement measurement is limited to 1/100 millimeter scale.

  • PDF

Design of Embedded EPGA for Controlling Humanoid Robot Arms Using Exoskeleton Motion Capture System (Exoskeleton 모션 캡처 장치로 다관절 로봇의 원격제어를 하기 위한 FPGA 임베디드 제어기 설계)

  • Lee, Woon-Kyu;Jung, Seul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.1
    • /
    • pp.33-38
    • /
    • 2007
  • In this paper, hardware implementation of interface and control between two robots, the master and the slave robot, are designed. The master robot is the motion capturing device that captures motions of the human operator who wears it. The slave robot is the corresponding humanoid robot arms. Captured motions from the master robot are transferred to the slave robot to follow after the master. All hardware designs such as PID controllers, communications between the master robot, encoder counters, and PWM generators are embedded on a single FPGA chip. Experimental studies are conducted to demonstrate the performance of the FPGA controller design.

Operating System Design of Multi Beam Control System with Miniaturized Electron Beam Columns (초소형 전자빔을 이용한 멀티 전자빔 운영 시스템 설계)

  • Lim, Sun Jong;Kim, Ho Seob
    • Laser Solutions
    • /
    • v.18 no.4
    • /
    • pp.12-16
    • /
    • 2015
  • The research on multi electron beam systems is being carried out by various methods. We are studying multi electron beam system using miniaturized electron beam columns. The column consists of electrostatic lenses, electrostatic deflector and tip emitter. Our operating system controls 4 column array, captures images of each column and maintains the instrument. We present the usefulness of our operating system for multi columns by capturing images of each column.

Magnetic wireless motion capturing system and its application for jaw tracking system and 3D computer input device

  • Shin Yabukami;Kaoru Arai;Arai, Ken-Ichi;Shinya Tsuji
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2002.12a
    • /
    • pp.12-12
    • /
    • 2002
  • We present the new jaw tracking system that utilizes five degrees of freedom of head and lower jaw. The proposed method does not disturb the physiology because the system does not need to fix magnetic field sensors or clutch on the patient's body or mouth. The impact of this result goes beyond the conventional optical and magnetic tracking system of jaw movement [1][2]. Position accuracy within 1mm and reasonable cost is necessary for practical use of the jaw tracking system. (omitted)

  • PDF