• Title/Summary/Keyword: capillary tube

Search Result 248, Processing Time 0.022 seconds

An investigation on the system characteristics of a refrigerator with alternative refrigerants (대체냉매를 이용한 가정용 냉장고의 시스템 특성에 관한 연구)

  • 신진규;문춘근;윤정인
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.753-762
    • /
    • 1998
  • A domestic refrigerator is composed of many components such as a compressor, evaporator, capillary tube, and the cabinet which plays a great role on the cycle performance, even if it is not the basic component part in the cycle. Recently, the restriction policy on the energy-saving and environmentally friendly refrigerator is reinforced in our nation as well as developed countries. Therefore, in this paper, cycle simulations and experiments were carried out ito understand the characteristics of the cycle performance using CFC 12, HFC 134a, and HC 600a and to know how changes in UA(overall heat transfer coefficients$\times$ heat transfer area) of evaporator, the position displacement of compressor, and the rpm of fan in the freezing room which has influence on the cycle performance. The result shows that the quantitative values of simulation and experiment are not coincident, but their trend is similar. When HFC 134a and HC 600a were used without the change of design in refrigerator used CFC 12, the performance of system in HC 600a is 30% lower, and the case of HFC 134a is 10% lower than that of CFC 12 on freezing temperature.

  • PDF

Cycle Simulation of the Air-Conditioner Using Alternatives to R22 (R22의 대체냉매를 사용한 공기조화기의 성능 시뮬레이션)

  • Chang, S.D.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.1
    • /
    • pp.47-53
    • /
    • 1994
  • Cycle simulation of the air-conditioner was carried out using a number of candidate alternatives to R22;R32/R125/R134a(30/10/60, by mass percent), R32/R125/R134a(10/70/20), R32/R134a(25/75), R32/R134a(30/70), R32/R125(60/40), R290(propane) and R134a. In this study, we considered only the basic parts of the air-conditioner such as the compressor, the evaporator, the condenser and the capillary tube, for the purpose of analysis. The performance characteristics of alternatives considered here were examined by comparing with the case using R22 at the constant volumetric flow rate condition. The results of our analysis revealed that the use of refrigerant mixtures, R32/R134a(30/70) and R32/R125/R134a(30/10/60), was appropriate for the alternatives to R22 in view of the cooling capacity and the COP. For the case of using R134a and R290, the COP was observed to increase under the same volumetric flow rate condition, but the cooling capacity was substantially decreased. Therefore the use of R134a and R290 should be accompanied with increasing considerably the size of compressor in order to maintain the same cooling capacity of R22.

  • PDF

An Experimental Study on the Dispersion Effect of Hydration Heat in the Mass Concrete Using OCHP (OCHP를 이용한 매스콘크리트 수화열 분산효과에 관한 실험적 연구)

  • Kim, Myung-Sik;Baek, Dong-Il;Kim, Kang-Min;Yum, Chi-Sun;Bae, Won-Mahn
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.437-440
    • /
    • 2006
  • In process of the mass concrete structure, the heat of hydration may cause serious thermal cracking. In order to eliminate hydration heat of mass concrete, this paper results of hydration heat control of mass concrete using the Oscillating Capillary tube Heat Pipe(OCHP). There were the several molds which shows a difference as compared with each other. One was not equipped with OCHP. Other were laid with OCHP, and the other were laid in 100cm, and exposed out 50cm. All of them were cooled with natural air convection. The OCHP was composed of copper pipe(outer diameter : 4mm, inner diameter : 2.8mm) and heat type was non-looped type. The working fluid was R-22 and its charging ratio was 40% by volume. The core of the concrete temperature was approximately $53^{\circ}C$ without OCHP. But the concrete temperature with OCHP was reduced its difference in temperature with the outdoor temperature to $12{\sim}15^{\circ}C$. Finally we saw the index figure of the thermal crack of the structures were varied from 0.6 to 1.6.

  • PDF

Investigation on the pressure drop characteristics of oscillating flow through regenerators under pulsating pressure conditions (맥동압력조건에서 재생기를 통한 왕복유동의 압력강하 특성에 대한 연구)

  • 최성열;남관우;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.2
    • /
    • pp.51-57
    • /
    • 2003
  • This paper proposes a new oscillating flow model of the pressure drop through the regenerator under pulsating pressure. In this oscillating flow model. pressure drop is expressed by the amplitude and the phase angle with respect to the inlet mass flow rate. In order to generalize the oscillating flow model. non-dimensional parameters, which are Reynolds number, Valensi number, gas domain length ratio, oscillating flow friction factor and phase angle of pressure drop, are derived from the capillary tube model of the regenerator. Correlations for the oscillating flow friction factor and the phase angle are obtained from the experiments for the twill-square screen regenerators under various operating frequencies and inlet mass flow rates. The oscillating friction factor is a function of the Reynolds number alone and the phase angle of pressure drop is a function of the Valensi number and the gas domain length ratio. Experiment is also performed to examine the effect of the weave style of screen. Experimental data demonstrate the superiority of the oscillating flow model over the previous steady flow model.

A Study on Performance Characteristics of Propane/Isobutane Refrigerant Mixtures in a Domestic Small Multi-Refrigeration System (프로판/이소부탄(R-290/R-600a) 혼합 냉매를 적용한 가정용 소형 멀티 냉동시스템의 성능특성에 관한 연구)

  • Kim Sanguk;Lee MooYeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.2 s.233
    • /
    • pp.271-278
    • /
    • 2005
  • In this paper, the performance of Kim-chi refrigerator with three evaporator and one compressor was investigated in employing $55\%$ propane and $45\%$ isobutane (R290/R600a) refrigerant mixture as an alternative refrigerant of R134a. The drop-in test was performed by varying both refrigerant charge and capillary tube length in order to find both the performance and reliability of a small multi-refrigeration system. Results show that the power consumption is decreased by about $15\%$ and COP is increased by about $10\%$, respectively as compared to the baseline system using R-134a. In addition, the propane/isobutane refrigerant mixture system took advantage of the minimization of modification and redesigning of system components because thermodynamic properties such as saturation pressure, temperature, normal boiling point(NBP) characteristics are similar to those of R134a. The reduction of sales cost is caused by the decrease of refrigerant cost per unit mass and refrigerant charge amount necessary for the refrigeration system.

Staphylococcusaureus protein A as a means of assessing sperm penetrability in cervical mucus in vitro

  • Al-Daghistani, Hala I.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.47 no.3
    • /
    • pp.186-193
    • /
    • 2020
  • Objective: The effectiveness of Staphylococcus protein A (SPA) in improving the penetration ability of sperm and reducing antisperm antibody (ASA) titers in immunologically infertile males was evaluated. Methods: Seminal fluid samples were obtained from 15 infertile men, and ASA titers were assessed with the latex agglutination test. Identification of immunoglobulin (Ig) classes and characterization of the antigens involved in the immune response were performed using indirect immunofluorescence. Local ASAs typically present as a mixture of IgG and IgA classes. The capillary tube penetration method was used to assess the capability of spermatozoa to penetrate the cervical mucus (CM). Results: ASAs associated with the neck region of sperm showed a significantly lower migration distance in the CM of infertile females than ASAs associated with the head or tail segments. ASA-positive seminal fluid exhibited significant increases in the mean migration distance (2.6 ± 1.4 cm vs. 1.54 ± 1.1 cm, respectively; p< 0.001) and sperm concentration (174 ± 121.0 × 103/mL vs. 101 ± 93.7 × 103/mL, respectively; p= 0.033) after treatment with SPA compared to pre-treated samples. A significant reduction (p< 0.01) in the recorded ASA titer was detected. Conclusion: These results indicate that SPA can be used as a sorting regimen for insemination programs. However, further studies are warranted to assess its influence on pregnancy rate.

In vitro Angiogenic Activity of Aloe vera Gel on Calf Pulmonary Artery Endothelial (CPAE) Cells

  • Lee, Myoung-Jin;Lee, Ok-Hee;Yoon, Soo-Hong;Lee, Seung-Ki;Chung, Myung-Hee;Park, Young-In;Sung, Chung-Ki;Choi, Jae-Sue;Kim, Kyu-Won
    • Archives of Pharmacal Research
    • /
    • v.21 no.3
    • /
    • pp.260-265
    • /
    • 1998
  • Angiogenic activity of Aloe vera gel was investigated by in vitro assay. We obtained the most active fraction from dichloromethane extract of Aloe vera gel by partitioning between hexane and 90% aqueous methanol. The most active fraction (F3) increased the proliferation of calf pulmonary artery endothelial (CPAE) cells. In addition, F3 fraction induced CPAE cells to invade type I collagen gel and form capillary-like tube through in vitro angiogenesis assay, and increased the invasion of CPAE cells into matrigel through in vitro invasion assay. Furthermore, the effect on the MRNA expression of proteolytic enzymes which are key participants in the regulation of extracellular matrix degradation was investigated by northern blot analysis. F3 fraction enhanced mRNA expression of urokinase-type plasminogen activator (u-PA), matrix metalloproteinase-2 (MMP-2), and membrane-type MMP (MT-MMP) in CPAE cells whereas the expression of plasminogen activator inhibitory (PAl-1) mRNA was not changed.

  • PDF

Anti-Angiogenic Activities of Gliotoxin and 1ts Methylthio-Derivative, Fungal Metabolites

  • Lee, Hee-Jung;Lee, Jeong-Hyung;Hwang, Bang-Yeon;Kim, Hang-Sub;Lee, Jung-Joon
    • Archives of Pharmacal Research
    • /
    • v.24 no.5
    • /
    • pp.397-401
    • /
    • 2001
  • In the search for new naturally occurring angiogenic inhibitory we found that culture broths from two unidentified fungal strains exerted potent inhibitory activities on capillary-like tube formation of human umbilical vein endothelial cells (HUVEC) in vitro. Two active compounds were isolated by bioassay-guided separation and their structures were identified as gliotoxin (1) and its derivative methylthiogliotoxin (2) by spectroscopic analyses. These compounds significantly inhibited the migration of HUVEC assessed by in vitro wounding migration assay and exhibited at least 10 times more potent inhibition of proliferation of HUVECs as compared with that of cancer cell lines such as HeLa, MCF-7, and KB 3-1 cells. Especially, gliotoxin having disulfide group exerted more potent activities than methylthiogliotoxin, suggesting that gliotoxin could be a useful compound for further study as an anti-angiogenic agent.

  • PDF

Performance Characteristics of a Loop Thermosyphon for Heat Source Cooling (열원 냉각용 루프 써모사이폰의 작동 특성)

  • Choi, Du-Sung;Song, Tae-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1475-1483
    • /
    • 2004
  • Loop thermosyphon(LTS) has many good characteristics such as low thermal resistance, no power consumption, noiseless operation and small size. To investigate the overall performance of LTS, we have performed various experiments varying three parameters: input power of the heater, working fluid(water, ethanol, FC3283) and filling ratio of the working fluid. At a combination of these parameters, temperature measurements are made at many locations of the LTS. The temperature difference between the evaporator and the condenser is used to obtain the thermal resistance. In addition, flow visualization using a high speed camera is carried out. The thermal resistance is not constant. It is lower at higher input power, which is one of the distinct merits of LTS. Flow instabilities are frequently observed when changing the working fluid, the input power and the filling ratio. The results show that the LTS can be readily put into practical use. Future practical application in electronic cooling is recommended.

Control of Potato Virus Y (PVY-VN) with Mineral Oil Treatment in Tobacco Burley 21 Fields (담배(Burley 21) 포장에서 mineral oil 처리에 의한 감자바이러스Y(PVY-VN) 방제)

  • 채순용;김상석;김영호;박은경
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.23 no.2
    • /
    • pp.115-122
    • /
    • 2001
  • The effect of mineral oil treatment in Burley 21 tobacco field on the control of potato virus Y(PVY-VN) mostly transmitted by green peach apid(Myzus persicae Sulzer) in nature was studied and the virus infection in some plants including potato, pepper, bramble, radish, etc near the tobacco fields as a virus infection source was tested by capillary tube precipitatioin test with PVY-antibody and bioassay in Xanthi-nc tobacco. The main source of PVY-VN infection in tobacco field in korea was potato(ca. 40% of test plants infected). Pepper and bramble were also infected by PVY-VN. The control level of PVY-VN infection by treatment of 0.75% liquid mineral oil with 3 % nonionic emulsifier to the plants was 84.8 % in case of the artificial transfection with a infected apterous aphid in laboratory. However, the reduction of PVY-VN disease severity in tobacco fields treated with mineral oil at late June was only 35.5%. These results suggest that mineral oil treatment is not so effective for the protection of aphid-born virus(PVY - VN) infection in tobacco fields.

  • PDF