• Title/Summary/Keyword: capillary phenomena

Search Result 45, Processing Time 0.03 seconds

Effect of Nonsolvent Additive in Casting Solutions on Polysulfone Membrane Preparation (Polysilfone 막의 제조에 있어 제막용액에 첨가된 비용매의 영향)

  • 한명진
    • Membrane Journal
    • /
    • v.6 no.3
    • /
    • pp.157-165
    • /
    • 1996
  • Polysulfone(PS) membranes were prepared from homogeneous PS solutions by the phase inversion technique. When propionic acid(PA) was added into a casting solution of n-methylpyrrolidone(NMP) and PS, precipitation rate of the solution film was accelerated. This kind of acceleration was consistent, even though a precipitating nonsolvent was changed from water to isopropanol. These phenomena were caused by decrease of nonsolvent tolerance in the casting solution due to addition of PA. PS powder was prepared by precipitation of a 3wt% solution in dimethylformamide(DMF) using ethanol as nonsolvent. Gas adsorption analysis of the powder showed that the capillary condensation sites were found in the powder structure. Membranes prepared from PS solution(15wt%) in NMP had the following characteristics of gas adsorption and water permeation. In gas adsorption analysis, the membrane precipitated using isopropanol showed low uptake of nitrogen gas and the capillary condensation sites were not found. On the contrary, a significant amount of the capillary condensation sites was found in the membrane coagulated by water, which was related to increase of nitrogen uptake. tn the membrane prepared froin the solution including PA, an increase of the Henry's law sites and the Langmuir sites was not found clearly. However, the capillary condensation sites were significantly increased, and the water transport also increased.

  • PDF

Study on Property of Diamond Mobile Telephone Windows

  • Lin, Liu-Tie;Sheng, Yang-Guang;Wu, Zhou-Jian;Ning, Sun-Yi
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.6 no.2
    • /
    • pp.105-107
    • /
    • 2002
  • a-C:H films were coated on windows of mobile telephone by RF plasma chemical vapor deposition equipment made in our company. Thickness of the coatings is about 0.7 micrometers and they have high hardness, low friction coefficient, good adhesion, high optical transparency and chemical inertness. Knoop hardness of the diamond-like carbon films on glass substrate is 2328 kg/mm$^2$. The adherence between films and substrate is good and shows to be 69 N by scratching test. The optical performance is improved obviously owing to coat the film on it. The index of the coated windows is 2.5, transmission of visible light is larger than 90%, and transmission of ultraviolet light decreases by 30% and the ultraviolet light can be obstructed obviously. The coated glass also has self-clean effect and decontamination ability. The films have hydrophobic character and the soakage angle of water drop is larger than 90 degrees. The windows have fog-proof ability owing to eliminate the capillary phenomena in the inner surface. The physics and chemical properties of the coated windows are steady. Study indicates that the performance of a-C:H coated mobile phone windows are improved notably on wear-resistance, corrosion-proof and optical properties and it is excellent mobile windows protective coatings.

  • PDF

New experiment recipe for chloride penetration in concrete under water pressure

  • Yoon, In-Seok;Nam, Jin-Won
    • Computers and Concrete
    • /
    • v.17 no.2
    • /
    • pp.189-199
    • /
    • 2016
  • Chloride penetration is considered as a most crucial factor for the determination of the service life of concrete. A lot of experimental tools for the chloride penetration into concrete have been developed, however, the mechanism was based on only diffusion, although permeability is also main driving forces for the chloride penetration. Permeation reacts on submerged concrete impacting for short to long term durability while capillary suction occurs on only dried concrete for very early time. Furthermore, hydrostatic pressure increases in proportional to measured depth from the surface of water because of the increasing weight of water exerting downward force from above. It is thought, therefore, that the water pressure has a great influence on the chloride penetration and thereby on the service life of marine concrete. In this study, new experiment is designed to examine the effect of water pressure on chloride penetration in concrete quantitatively. As an experiment result, pressure leaded a quick chlorides penetration by a certain depth, while diffusion induced chlorides to penetrate inward slowly. Therefore, it was concluded that chloride should penetrates significantly by water pressure and the phenomena should be accelerated for concrete exposed to deep sea. The research is expected as a framework to define the service life of submerged concrete with water pressure and compute water permeability coefficient of cementitious materials.

Investigation on the Properties of a Microcellular Light-Weighted Humidity Controlling Tile (마이크로셀룰라 경량 조습타일의 특성 고찰)

  • Song, In-Hyuck;Lee, Eun-Jung;Kim, Hai-Doo;Kim, Young-Wook;Yun, Dal-Woong
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.5
    • /
    • pp.404-411
    • /
    • 2011
  • The humidity controlling ceramic materials was developed by applying the phenomena of dew condensation in the capillary. It is said that the humidity range which human feels comfortable is from 40 to 70% in relative humidity. In this study, the ceramic tile using natural soils such as diatomite for interior wall was investigated. In particular, we had introduced novel processing routes for fabricating microcellular ceramics tile using hollow microsphere as a pore former. The microcellular pores in the humidity controlling ceramic materials showed the superior properties such as light-weight, heat insulation. The cell density was ${\sim}1.0{\times}10^9$ cells/$cm^3$ and density of sample was 0.65 g/$cm^3$ in the case of 1.71 wt% hollow microsphere content. Also, it is observed that the BET surface area and the pore volume of the sintered diatomite tile have the values of 40.92 $m^2$/g and 0.173 $cm^3$/g.

Study of Adhesion Phenomena of Alkoxysilane-type Consolidants on Fresh Granites (알콕시 실란계 석재 강화제의 화강암 점착 특성 연구)

  • Kim, Eun-Kyung;Son, Seung-Hwan;Won, Jong-Ok;Kim, Jeong-Jin;Kim, Sa-Dug
    • Journal of Conservation Science
    • /
    • v.23
    • /
    • pp.1-10
    • /
    • 2008
  • Consolidants based on tetraethoxysilane (TEOS) such as alkoxysilanes have been widely used for the consolidation of decaying stone heritages. Low-viscosity alkoxysilanes penetrate inside the decaying stone and polymerize within the porous structure of the decaying stone, significantly increasing the cohesion of the material. However, TEOS-based consolidants suffer from practical drawbacks, such as crack formation of the gel during the drying phase due to the developed capillary force, which is typical for TEOS-based consolidants. We prepared new consolidants TEOS-based consolidants containing flexible (3-glycidoxypropyl)trimethoxysilane (GPTMS) and silica nanoparticles (or polyhedral oligomeric silsesquioxanes (POSS)) in order to reduce capillary force development during gel drying. Since the consolidants should have a good interaction with the component of the stone in order to connect the isolate grains of decaying stone, the adhesion interaction of the developed consolidants on the surface of the granite was macroscopically investigated by the ISO 2409 cross cutting test. The adhesion interaction decreased with the addition of silica nanoparticle and POSS while it increased with the addition of GPTMS in TEOS solution.

  • PDF

Fundamentals of Contact Lens Movement (콘택트렌즈 운동의 기초)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.5-13
    • /
    • 2008
  • Purpose: This review article was written to investigate what kind of forces are acting on the contact lens fitted on the cornea and its subsequent motion. Methods: A capillary action-induced force develops in the tear layer between the lens and cornea, which leads to the restoring force due to difference in layer thickness according to lens rotation. The characteristics of the lens movement can be determined by the various factors such as friction between eyelid and lens, acceleration force based on blinking and the restoring force incorporated with the viscous damping force. A mathematical model which consists of the differential equations and their numerical solution was proposed to analyze the damped motion of lenses. The model predicts the time dependence of lenses during and after the blink varying the BC, blink period and eyelid pressure. Results: It was found that both the blink period and lid pressure increases the movement increases because of the enhanced lid friction. As the BC increases the viscous damping reduces due to the lacrimal layer's increase which resulted in the enhanced lens motion. After blink the lens illustrates the damped oscillation because of the restoring force by the increased lacrimal layer thickness and reduced viscous resistance. The time for the lens to return to the equilibrium shortens as the BC increase because of the resistance reduction. Conclusions: The movement of the contact lens is governed by the characteristics of the lacrimal layer between the lens and cornea as well as the lid blink.

  • PDF

Rheological Characteristics of Highly Concentrated Polymer Bonded Explosive Simulant: Wall Slip, Thixotropy, and Flow Instability (고농축 복합화약 시뮬란트의 유변학적 특성: 벽면 미끄러짐, 틱소트로피, 유동불안정성)

  • Lee, Sangmook;Hong, In-Kwon;Ahn, Youngjoon;Lee, Jae Wook
    • Polymer(Korea)
    • /
    • v.38 no.2
    • /
    • pp.213-219
    • /
    • 2014
  • The rheological characteristics of highly concentrated polymer bonded explosive simulant were studied. Hydroxyl terminated polybutadiene (HTPB) and polyethylene plastomer (Exact) were used as binders. Sugar and Dechlorane particles whose physical properties are similar to research department explosive (RDX) were used as fillers. When HTPB was used, diethyl hexyl adipate (DEHA or DOA) was used as a plasticizer together for some cases. Highly concentrated suspensions were mixed in a batch melt mixer (Rheomixer 600, Haake) and rheological properties were measured by plate-plate and capillary rheometers. Wall slip phenomena, thixotropy with shear hysteresis, and flow instability were investigated as shear rate and amount of fillers changed.

Highly Concentrated Polymer Bonded Explosive Simulant: Rheology of Exact/Dechlorane Suspension (고농축 복합화약 시뮬란트: Exact/Dechlorane 현탁계의 유변물성)

  • Lee, Sangmook;Hong, In-Kwon;Lee, Jae Wook;Lee, Keun Deuk
    • Polymer(Korea)
    • /
    • v.38 no.3
    • /
    • pp.286-292
    • /
    • 2014
  • The rheology of highly concentrated polymer bonded explosive (PBX) simulant was studied. An energy material, polyethylene plastomer (Exact$^{TM}$) having similar properties to poly(BAMO-AMMO) was selected as a binder. Dechlorane with similar properties to RDX (Research Department eXplosive) was chosen as a filler. Mixing behavior in a batch melt mixer was investigated. During mixing a large amount of heat of viscous dissipation was generated and a continuous decrease in torque was observed when the filler content was above 70 v%. It was believed due to wall slip phenomena. From the SEM images, the fillers were well dispersed and the effect of mixing condition affected slightly on the dispersion. Owing to distinct shear thinning behavior of the suspensions, measuring viscosity of highly filled suspensions was possible in a high shear rate capillary rheometer though it was impossible even in a low shear rate plateplate rheometer.

Effect of Artemisia messes-schmidiana var viridis on lipid and histopathology for 1-naphthylisothiocyanate-induced intrahepatic cholestasis in rat (1-naphthylisothiocyanate에 기인된 랫드의 간내성 담즙분비 정지에 대한 인진호(Artemisia messes-schmidiana var viridis)의 지질 및 조직병리학적 영향)

  • Kim, Kil-soo;Jeong, Young-gil;Kim, Moo-kang
    • Korean Journal of Veterinary Research
    • /
    • v.35 no.3
    • /
    • pp.489-496
    • /
    • 1995
  • Artemisia messes-schmidiana var viridis(Compositae) has been used for jaundice, hepatitis, diuretic and liver cirrhosis etc. 1-naphthylisothiocyanate(ANIT) has been used as a model compound to study mechanisms of intrahepatic cholestasis in laboratory animals as rat and mouse. The purposes of present study are to examine pharmacological effects of Artemisia messes-schmidiana var viridis water extract(AMWE) on alterations of triacylglycerol, cholesterol, protein, albumin and A/G ratio levels in serum, of histopathological appearances of liver, and that of hepatic microsomal cytochrome P-450 contents. Increased serum triacylglycerol levels by ANIT were significantly decreased with AMWE. However, AMWE posttreatment aggravated ANIT-induced cholesterol increase. Serum total protein and albumin contents, and A/G ratio were decreased in all ANIT-treated groups, and there were increased compared with control by AMWE posttreatment. Hepatic microsomal cytochrome P-450 contents were decreased in either AMWE and ANIT treatment, which greatly increased with AMWE pretreatment. On the other hand, in histological findings, our results shown that ANIT induced increase of lipid droplets and widening of sinusoidal capillary and these phenomena were disappeared with AMWE treatment. In conclusion, AMWE have choleresis effect. Also, AMWE improved lipid metabolism, protection and regeneration of hepatocytes in ANIT-induced cholestasis.

  • PDF

Design of Fluorescence Multi-cancer Diagnostic Sensor Platform based on Microfluidics (미세 유체 기반의 형광 다중 암 진단 센서 플랫폼 설계)

  • Lee, B.K.;Khaliq, A.;Jeong, M.Y.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.4
    • /
    • pp.55-61
    • /
    • 2022
  • There is a major interest in diagnostic technology for multiple cancers worldwide. In order to reduce the difficulty of cancer diagnosis, a liquid biopsy technology based on a microfluidic device using trace amounts of biofluids such as blood is being studied. And optical biosensing, which measures the concentration of analytes through fluorescence imaging using biofluids, requires various strategies to improve sensitivity, and specialists and equipment are needed to carry out these strategies. This leads to an increase in diagnostic and production costs, and it is necessary to develop a technology to solve this problem. In this paper, we design and propose a fluorescent multi-cancer diagnostic sensing platform structure that implements passive self-separation technology and molecular recognition activation functions by fluid mixing, only with the geometry and microfluidic phenomena of microchannels based on self-driven flow by capillary force. In order to check the parameters affecting the performance of the plasma separation part of the designed sensor, the hydrodynamic diameter of the channel and the viscosity of the fluid were set as variables to confirm the formation of plasma separation flow through simulation. And finally, we propose an optimal sensor platform structure.