• Title/Summary/Keyword: capillary model

Search Result 246, Processing Time 0.034 seconds

Performance analysis of a cold-air forced circulation type showcase (냉기 강제순환형 공랭식 쇼케이스 성능 해석)

  • Kim, Jeong-Sik;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1003-1010
    • /
    • 2013
  • In this study, a simulation program was developed, which predicts the performance of cold-air forced circulation type air cooled showcase. The showcase has an excellent display effect in addition to preserving the grocery. In the program, the compressor was analyzed using performance data supplied by the manufacturer and the capillary tube pressure drop was analyzed using a homogeneous model. The evaporator and condenser were analyzed by dividing the heat exchangers into small elements, where energy balance and appropriate heat transfer correlations were used. A showcase model with two 3/4 HP compressors, capillary tubes of 1.6 mm inner diameter, a fin-and-tube evaporator and condenser was tested, and the results are compared with the predicted values. It is shown that both evaporation and condensation temperatures are adequately predicted by the program.

The Change of Taurine Transport in Variable Stress States through the Inner Blood-Retinal Barrier using In Vitro Model

  • Kang, Young-Sook;Lee, Na-Young;Chung, Yeon-Yee
    • Biomolecules & Therapeutics
    • /
    • v.17 no.2
    • /
    • pp.175-180
    • /
    • 2009
  • Taurine is the most abundant free amino acid in the retina and transported into retina via taurine transporter (TauT) at the inner blood-retinal barrier (iBRB). In the present study, we investigated whether the taurine transport at the iBRB is regulated by oxidative stress or disease-like state in a conditionally immortalized rat retinal capillary endothelial cell line (TR-iBRB) used as an in vitro model of iBRB. First, [$^3H$]taurine uptake and efflux by TR-iBRB were regulated in the presence of extracellular $Ca^{2+}$. [$^3H$]Taurine uptake was inhibited and efflux was enhanced under $Ca^{2+}$ free condition in the cells. In addition, oxidative stress inducing agents such as tumor necrosis factor-$\alpha$ (TNF-$\alpha$), lipopolysaccharide (LPS), diethyl maleate (DEM) and glutamate increased [$^3H$]taurine uptake and decreased [$^3H$]taurine efflux in TR-iBRB cells. Whereas, 3-morpholinosydnonimine (SIN-1), which is known to NO donor decreased [$^3H$]taurine uptake. Lastly, TR-iBRB cells exposed to high glucose (25 mM) medium and the [$^3H$]taurine uptake was reduced about 20% at the condition. Also, [$^3H$]taurine uptake was decreased by cytochalasin B, which is known to glucose transport inhibitor. In conclusion, taurine transport in TR-iBRB cells is regulated diversely at extracellular $Ca^{2+}$, oxidative stress and hyperglycemic condition. It suggested that taurine would play a role as a retinal protector in diverse disease states.

Decision of Available Soil Depth Based on Physical and Hydraulic Properties of Soils for Landscape Vegetation in Incheon International Airport

  • Jung, Yeong-Sang;Lee, Hyun-Il;Jung, Mun-Ho;Lee, Jeong-Ho;Kim, Jeong-Tae;Yang, Jae E
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.48 no.5
    • /
    • pp.522-527
    • /
    • 2015
  • Decision of available soil depth based on soil physical and hydraulic properties for the $3^{rd}$ Landscape Vegetation Project in the Incheon International Airport was attempted. The soil samples were collected from the 8 sites at different depths, 0-20 and 20-60cm, for the three project fields, A, B, and C area. Physical and chemical properties including particle size distribution, organic matter content and electrical conductivity were analyzed. Hydrological properties including bulk density and water holding capacity at different water potential, -6 kPa, -10 kPa, -33 kPa, and -1500 kPa were calculated by SPAW model of Saxton and Rawls (2006), and air entry value was calculated by Campbell model (1985). Based on physical and hydrological limitation, feasibility and design criteria of soil depth for vegetation and landfill were recommended. Since the soil salinity of the soil in area A area was $19.18dS\;m^{-1}$ in top soil and $22.27dS\;m^{-1}$ in deep soil, respectively, landscape vegetation without amendment would not be possible on this area. Available soil depth required for vegetation was 2.51 m that would secure root zone water holding capacity, capillary fringe, and porosity. Available soil depth required for landscape vegetation of the B area soil was 1.51 m including capillary fringe 0.14 m and available depth for 10% porosity 1.35 m. The soils in this area were feasible for landscape vegetation. The soil in area C was feasible for bottom fill purpose only due to low water holding capacity.

Relation between Autogenous Shrinkage of Concrete and Relative Humidity, Capillary Pressure, Surface Energy in Pore (공극 내 상대습도, 모세관압력, 표면에너지 변화에 따른 콘크리트 자기수축)

  • Lee, Chang-Soo;Park, Jong-Hyok
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.2
    • /
    • pp.131-138
    • /
    • 2008
  • Humidity and strain were estimated for understanding the relation between humidity change by self-desiccation and shrinkage in high-performance concrete with low water binder ratio. Internal humidity change and shrinkage strain were about 10%, 4% and $320\times10^{-6}$, $120\times10^{-6}$ respectively on concrete with water binder ratio 0.3, 0.4 and from the results, humidity change and shrinkage represented the strong linear relation regardless of mixture. For specifying the relation on internal humidity change and autogenous shrinkage strain, shrinkage model was established which is driven by capillary pressure in pore water and surface energy in hydrates on the assumption of a single network and extended meniscus in pore system of concrete. This model and experimental results had a similar tendency so it would be concluded that the internal humidity change by self-desiccation in HPC originated in small pores less than 20 nm, therefore controlling plan on autogenous shrinkage might be focused on surface tension of water and degree of saturation in small pore.

Investigation on the pressure drop characteristics of oscillating flow through regenerators under pulsating pressure conditions (맥동압력조건에서 재생기를 통한 왕복유동의 압력강하 특성에 대한 연구)

  • 최성열;남관우;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.2
    • /
    • pp.51-57
    • /
    • 2003
  • This paper proposes a new oscillating flow model of the pressure drop through the regenerator under pulsating pressure. In this oscillating flow model. pressure drop is expressed by the amplitude and the phase angle with respect to the inlet mass flow rate. In order to generalize the oscillating flow model. non-dimensional parameters, which are Reynolds number, Valensi number, gas domain length ratio, oscillating flow friction factor and phase angle of pressure drop, are derived from the capillary tube model of the regenerator. Correlations for the oscillating flow friction factor and the phase angle are obtained from the experiments for the twill-square screen regenerators under various operating frequencies and inlet mass flow rates. The oscillating friction factor is a function of the Reynolds number alone and the phase angle of pressure drop is a function of the Valensi number and the gas domain length ratio. Experiment is also performed to examine the effect of the weave style of screen. Experimental data demonstrate the superiority of the oscillating flow model over the previous steady flow model.

Hemodynamic Evaluation of Acute Mitral Valve Insufficiency Model induced by Chordae Tendinae Rupture in Normal Dogs (개에서 건삭파열로 유발한 급성 이첨판 폐쇄부전 모델의 혈류역학적 평가)

  • Kim, Sehoon;Kim, Nam-Soo;Lee, Ki-Chang;Kim, Jong Min;Kim, Min-Su
    • Journal of Veterinary Clinics
    • /
    • v.31 no.5
    • /
    • pp.367-370
    • /
    • 2014
  • The study was to observe hemodynamic alterations of cardiac function to design a model of canine mitral valve insufficiency (MVI) based on chordae tendinae rupture (CTR). Ten healthy beagles with normal heart function were used in this study. To measure hemodynamics, the patient monitor was equipped for invasive blood pressure and a Swan-Ganz catheter. Hemodynamic alterations were checked promptly during CTR procedures. MVI model was made by transection of the chordae tendinae with small arthroscopy hook knife through $5^{th}$ intercostal open chest. Color Doppler at the level of the mitral valve showed high-velocity regurgitant flow immediately after CTR at intraoperative echocardiography. In hemodynamic measurements, pulmonary capillary wedge pressure (PCWP) was significantly increased, while mean arterial pressure (MAP), venous pressure (VP), pulmonary arterial pressure (PAP), cardiac output (CO) and cardiac index (CI) were significantly decreased after CTR. It was known that the left atrium was overloaded by regurgitant volume from the left ventricle. In conclusion, the MVI model induced by CTR technique in this study should be used as suitable one for the effective research of canine mitral valve disease. Further study should be needed to measure the chronic alternation of mitral valve in the model.

Discrimination of Geographical Origin for Astragalus Root (Astragalus membranaceus) by Capillary Electrophoresis and Near-Infrared Spectroscopy (Capillary electrophoresis 및 근적외선분광분석기를 이용한 황기의 원산지 판별)

  • Kim, Eun-Young;Kim, Jung-Hyun;Lee, Nam-Yun;Kim, Soo-Jeong;Rhyu, Mee-Ra
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.818-824
    • /
    • 2003
  • Capillary electrophoresis (CE) and near-infrared spectroscopy (NIRS) were performed to discriminate astragalus roots (Astragalus membranaceus) according to geographical origin (domestic or foreign). Two-hundred-and-four astragalus roots were extracted with 30% methanol in 0.1 M phosphate buffer (pH 2.5) and separated in a uncoated fused-silica $(50\;{\mu}m{\times}27\;cm)$ capillary. Conditions for optimal analysis included: temperature $-45^{\circ}C$, voltage -14 kV, and pressure injection time -8 sec. The optimal separation buffer was 0.1 M phosphate buffer (pH 2.5) containing 40 mM hexane sulfonic acid with 20% 2-methoxy ethanol. Raw NIR spectra were obtained using NIRS, and modified partial least square regression was used to develop the prediction model. The correlation coefficient and standard error of prediction were 0.915 and 14.3%, respectively. Under the optimal conditions established for CE and NIRS, the geographical origins of the astragalus roots were correctly identified in 80 and 97%, respectively. Astragalus roots that were not discriminated by NIRS were correctly discriminated by CE. Hence, CE and NIRS are potential methods for discriminating the geographical origins of astragalus roots that complement one another.

Hydrate Researches in the flow assurance (가스 하이드레이트와 파이프라인 유동 안정성)

  • Kim, Yong-Heon;Yang, Sung-Oh
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.425-428
    • /
    • 2006
  • Natural gas hydrate has been a major problem for its plugging nature in the pipeline. With the demand of deep-water production, the importance of flow assurance technology, preventing hydrate, asphaltene and wax in the pipeline becomes bigger Kinetic models combined with the flow simulator are being developed to explain the nature of hydrate plug formation in the pipeline. To simulate the hydrate plug formation, each stage including the nucleation, growth and agglomeration should be considered. The hydrate nucleation is known to be stochastic and is believed hard to be predicted. Recent publications showed hydrate growth and agglomeration can be observed rigorously using a particle size analyzer. However properties of the hydrate should be investigated to model the growth and agglomeration. The attractive force between hydrate particles, supposed to be the capillary force, was revealed to be stochastic. Alternative way to model the hydrate agglomeration is to simulate by the discrete element method. Those parameters, particle size distribution, attractive force, and growth rate are embedded into the kinetic model which is combined Into the flow simulator. When compared with the flowloop experimental data, hydrate kinetic model combined into a flow simulator showed good results. With the early results, the hydrate kinetic model is promising but needs more efforts to improve it.

  • PDF

Amplitude-dependent Complex Stiffness Modeling of Dual-chamber Pneumatic Spring for Pneumatic Vibration Isolation Table (공압제진대용 이중챔버형 공압스프링의 복소강성 모형화)

  • Lee, Jeung-Hoon;Kim, Kwang-Joon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.1
    • /
    • pp.110-122
    • /
    • 2008
  • Pneumatic vibration isolator typically consisting of dual-chamber pneumatic springs and a rigid table are widely employed for proper operation of precision instruments such as optical devices or nano-scale equipments owing to their low stiffness- and high damping-characteristics. As environmental vibration regulations for precision instruments become more stringent, it is required to improve further the isolation performance. In order to facilitate their design optimization or active control, a more accurate mathematical model or complex stiffness is needed. Experimental results we obtained rigorously for a dual-chamber pneumatic spring exhibit significantly amplitude dependent behavior, which cannot be described by linear models in earlier researches. In this paper, an improvement for the complex stiffness model is presented by taking two major considerations. One is to consider the amplitude dependent complex stiffness of diaphragm necessarily employed for prevention of air leakage. The other is to employ a nonlinear model for the air flow in capillary tube connecting the two pneumatic chambers. The proposed amplitude-dependent complex stiffness model which reflects dependency on both frequency and excitation amplitude is shown to be very valid by comparison with the experimental measurements. Such an accurate nonlinear model for the dual-chamber pneumatic springs would contribute to more effective design or control of vibration isolation systems.

Experimental Study on Characteristics of Two-Phase Flow through a Bypass Orifice Expansion Device

  • Choi, Jong-Min;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.1
    • /
    • pp.11-19
    • /
    • 2001
  • To establish optimum cycle of the inverter-driven heat pump with a variation of frequency, the bypass orifice, which was a short tube haying a bypass hole in the middle, was designed and tested. Flow characteristics of the bypass orifice were measured as a function of orifice geometry and operating conditions. Flow trends with respect to frequency were compared with those of short tube orifices and capillary tubes. Generally, the bypass orifice showed the best flow trends among them. and it would enhance the seasonal energy efficiency ratio of an inverter heat pump system, Based on experimental data, a semi-empirical flow model was developed to predict mass flow rate through bypass orifices. The maximum difference between measured data and model`s prediction was within $\pm$5%.

  • PDF