• Title/Summary/Keyword: capacity loss

Search Result 1,664, Processing Time 0.03 seconds

Muscle Fiber Characteristics and Their Relationship to Water Holding Capacity of Longissimus dorsi Muscle in Brahman and Charolais Crossbred Bulls

  • Waritthitham, A.;Lambertz, C.;Langholz, H.-J.;Wicke, M.;Gauly, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.23 no.5
    • /
    • pp.665-671
    • /
    • 2010
  • Muscle fiber characteristics and their relationship to water-holding capacity of longissimus dorsi (ld) muscle were studied in Brahman (BRA) and Charolais (CHA) crossbred bulls fattened under practical farm conditions. Thirty-four BRA and 34 CHA bulls were randomly selected and slaughtered at 500, 550 and 600 kg live weight. Parameters of water-holding capacity such as drip, ageing, thawing, cooking and grilling loss were determined. Muscle fiber characteristics were conducted for muscle fiber type percentage and cross-sectional areas of slow- and fast-twitch fiber types, and correlation coefficients to water-holding capacity parameters were calculated. Results showed that CHA meat had a better water-holding capacity (less ageing, thawing and grilling loss) when compared with BRA, whereas slaughter weights had no significant effects on these parameters. Furthermore, there were no significant differences between genotypes and slaughter weights in muscle fiber type percentage and cross-sectional areas of ld muscle. Slow- and fast-twitch fiber types of all experimental groups averaged 24.4 and 75.6%, respectively. Cross-sectional areas of fast-twitch fibers had almost twice the size of slow-twitch fibers (6,721 and 3,713 ${\mu}m^2$, respectively). The correlation between muscle fiber area and water-holding capacity indicated that muscles with larger fiber areas had a lower drip and ageing loss but a higher cooking and grilling loss.

A Study on Properties of C-V Degradation due to Heating in Teflon (테프론의 가열에 의한 C-V 열화 특성에 관한 연구)

  • Lee, Sung Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.11
    • /
    • pp.730-735
    • /
    • 2014
  • In this study, the temperature characteristics of electrostatic capacity and dielectric loss for the sample of Teflon film which is degradated at the $120^{\circ}C{\sim}200^{\circ}C$ temperature range in the oven for 10 hours has been measured in through the applied frequency range of 0.1 kHz~4,800 kHz at temperature of $50^{\circ}C$, $90^{\circ}C$, $130^{\circ}C$, $170^{\circ}C$. Also, in the same conditions, the frequency characteristics of electrostatic capacity and dielectric loss for the sample of Teflon film has been measured in through the applied temperature range of $30^{\circ}C{\sim}70^{\circ}C$ on setting frequency of 0.1 kHz, 1 kHz, 10 kHz, 100 kHz. The results of this study are as follows. When the frequency range of 0.1 kHz~4,800 kHz applied to the sample of Teflon film, the electrostatic capacity has been measured at the temperature of $50^{\circ}C$, $90^{\circ}C$, $130^{\circ}C$, $170^{\circ}C$. Through this measurement, it found that the electrostatic capacity decreased with increasing temperature. Regarding this result, may be it is because the electromagnetic coupling is degraded by thermal degradation. When the sample of Teflon film heated at $280^{\circ}C$ for 10 hours in oven, the dielectric loss has changed from unstable status to stabilizing status with increasing the degradation temperature in the $120^{\circ}C$, $160^{\circ}C$, $200^{\circ}C$ range. In this measurement, the two spectrums of dielectric loss appeared. It considers that this spectrum of dielectric loss appeared in 300 Hz is caused by the molecular motion of the C-F or OH group. Through this study, It found that the electrostatic capacity decreased with increasing frequency and temperature, and there is no change in dielectric loss, although the frequency increases.

An Experimental study to Improving the Sound Transmission Loss of Honeycomb sandwich Plates (허니컴 샌드위치판의 투과손실 개선에 관한 실험적 연구)

  • 유영훈;양보석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.2
    • /
    • pp.92-99
    • /
    • 1998
  • The sound insulation capacity of honeycomb sandwich plates which have relatively higher strength ratios to weight is poorer than those of uniform and another sandwich plates. Therefore, improvement of the sound insulation capacity of the honeycomb sandwich plate which has a meritof lightness is required to use it in automobile and rapid rail road industries. In this study, to improving the sound insulation capacity of the honeycomb sandwich plate, the sound transmission loss of the structure is experimentally investigated by adding a viscoelastic damping layer, The effective add position and thickness of the layer were investigated from the viewpoints of both sound transmission loss and improved sound transmission loss over the frequency range from 800Hz to 10kHz.

  • PDF

A Second-Order Analysis of VM Heat Pumps (VM열펌프의 2차해석)

  • Choi, Y.S.;Jeong, E.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.208-218
    • /
    • 1996
  • Performance of a VM heat pump is considerably affected by various losses, such as enthalpy dump, reheat loss, pumping loss, conduction loss and shuttle loss. A second-order analysis model of VM heat pumps, which allows consideration of the major losses, was presented. Actual heat transfer rates for heat exchangers were calculated from the heat transfer rates obtained by the adiabatic analysis and various losses. New effective temperatures of heat exchangers were calculated from the actual heat transfer rates and the mean heat transfer coefficients until there was no appreciable change in the effective temperatures. Effects of design parameters, such as phase angle, swept volume ratio, regenerator length and speed on heating capacity, cooling capacity and COP were shown.

  • PDF

Effects of soft handoff region ratio on the reverse link capacity of a DS-CDMA cellular system (DS-CDMA 셀룰라 시스템의 역방향 링크에서 소프트 핸드오프 영역비율의 효과)

  • 전형구;권오준;강창언
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.11B
    • /
    • pp.1534-1539
    • /
    • 2001
  • In this paper, effects of soft handoff region on the reverse link capacity of a DS-CDMA cellular system are investigated. The reverse link capacity of a CDMA cellular system is calculated at a given soft handoff region ratio (SHRR) and path loss model. The results show that the reverse link capacity increases by 1 ∼ 4 channels according to the soft handoff region ratio and the path loss model. However, in the case of the path loss model having a large attenuation exponent ($\mu$ = 5) and a small shadowing standard deviation ( $\sigma$ = 6 dB), the reverse link capacity is no more increased by increasing SHRR.

  • PDF

Case Studies on the Electric Power Loss Reducing Methodology for Transformer Installation in Sewage Treatment Plant (하수처리장 변압기 설치사례 연구를 통한 전력손실 저감방안)

  • Kim, Chu-Young;Choi, Chang-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.70-77
    • /
    • 2011
  • Sewage treatment plants, consuming 1,756[GWh] which is 0.53[%] of national wide electricity consumption, is one of the electricity consuming facilites. At the research of electricity consumption and power quality analysis on sewage treatment plants, average utilization of transformer was less than 40[%] because peak load was very lower than its capacity due to excess capacity. So reduction of power loss can be achieved by transformer design optimization. The achievement in this research, is to meet reduction of power loss through optimizing the capacity and to improve as high efficiency-low loss transformer while the transformer is operating.

Selection of Oxygen Carrier Candidates for Chemical Looping Combustion by Measurement of Oxygen Transfer Capacity and Attrition Loss (산소전달량 및 마모손실 측정에 의한 매체순환연소용 산소전달입자 후보 선정)

  • KIM, HANA;PARK, JAEHYEON;BAEK, JEOM-IN;RYU, HO-JUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.4
    • /
    • pp.404-411
    • /
    • 2016
  • To select appropriate oxygen carrier candidates for chemical looping combustion, reduction characteristics of seven oxygen carriers were measured and discussed using three different reduction gases, such as $H_2$, CO, and $CH_4$. Moreover, attrition losses of those oxygen carriers also measured and compared. Among seven oxygen carrier particles, OCN703-1100 and NiO/bentonite particles showed higher oxygen transfer capacity than other particles, but these particles showed more attrition loss than other particles. C14 and C28 particles which used as cheap oxygen carriers in European country showed lower oxygen transfer capacity and less attrition loss. Based on the experimental results, we could select OCN717-R1SU, NC001, and N002 particles as candidates for future works because these oxygen carriers showed enough oxygen transfer capacity and good attrition resistance.

A Study on Insulation Degradation Properties of Thermal Conductive Silicone Rubber due to Temperature Transition (온도 변화에 의한 열전도성 실리콘 고무의 절연 열화 특성)

  • Lee, Sung Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.7
    • /
    • pp.456-461
    • /
    • 2015
  • In this study, the frequency properties of electrostatic capacity and dielectric loss for the samples with different types of filler has been measured in through the applied frequency range of 7 kHz ~3,000 kHz at temperature of $80^{\circ}C$, $110^{\circ}C$, $140^{\circ}C$, $170^{\circ}C$. The results of this study are as follows. When the sample is degradated at the temperature of $80^{\circ}C$, $110^{\circ}C$, $140^{\circ}C$, $170^{\circ}C$ and the frequency range of 7 kHz ~3,000 kHz is applied, It found that the electrostatic capacity of the sample with Polyimide film is larger than the sample with Grass fiber. It found that the dielectric loss for the sample with Polyimide film is larger than the sample with Grass fiber with increasing frequency and temperature in the $80^{\circ}C$, $110^{\circ}C$, $140^{\circ}C$, $170^{\circ}C$ range. Also, the dielectric loss decreased with increasing frequency. In case of the sample with Polyimide film, It found that the electrostatic capacity decreased with increasing temperature, and the dielectric loss gradually decreased with increasing frequency.

A study of the relationship between Sedimentation and Storage requirments of reservoirs (저수지 내용적 감소가 필요저수량에 미치는 영향에 관한 연구)

  • 신일선;김재곤;김시원
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.21 no.1
    • /
    • pp.53-62
    • /
    • 1979
  • Since the first installation of irrigation Systems in Korea , a large number of small and medium sized reservoirs have been constructed as the main water sources Some 412, 000 ha are at present irrigated from these sources of supply. Many of the reservoirs were designed in accordance with old low standards and have in addition suffered a loss in capacity through sedimentation. At the same time, water demand has increased with the in troduction of high yielding varieties of rice. The combination has resulted in severe water deficits. To study the problem, 16 sample reservoirs have been surveyed and analysed. The results of the study are summarized be low: 1. Average decrease in reservoir capacity from the installation to present-8% 2. Average soil erosion loss (m$^3$/km$^2$/year) is 536 m$^3$/km$^2$/year and average erosion depth of soil is 0. 5mm per year. 3. No relationship, between reservoir capacity per unit of watershed (m$^3$/km$^2$) and soil erosion loss was found. 4. Increases are required in reservoir capacity: 15.8% due to the introduction of HYV's; 16.6% due to the change of system losses from 10%to 25% The conclusion to be drawn from the above results is that existing reservoir capacity should be increased by an average of 32%. The unit storage capacity to be adopted should be 661 mm

  • PDF

Experimental study on the correlation between measurement length and winding or twist pitch for magnetization loss occurring in CORC and TSTC

  • Ji-Kwang Lee;Jinwoo Han;Kyeongdal Choi;Woo-Seok Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.4
    • /
    • pp.40-44
    • /
    • 2023
  • For high-temperature superconducting power applications that need large current capacity, a large current conductor manufactured using multiple superconducting tape is required. Conductors being studied for large currents capacity such as CORC, TSTC, and RACC have advantages and disadvantages, and in order to use these conductors in coil form and apply them to AC power devices, research on magnetization loss occurring in superconductors due to external magnetic fields is essential. To accurately measure magnetization loss in a conductor that is twisted by stacking straight conductors like TSTC, the correlation between the measuring system and the shape of the sample must be clearly known to accurately measure the loss. In this paper, we will confirm the difference in magnetization loss measurement values according to the correlation between the length of the pickup coil and the twist pitch of the sample in CORC and TSTC shapes, and review considerations for accurate magnetization loss measurement from the results.