• 제목/요약/키워드: capacitive-type

검색결과 221건 처리시간 0.031초

서브미크론 진직도 측정장치 개발 (Development of a Submicron Order Straightness Measuring Device)

  • 박천홍;정재훈;김수태;이후상
    • 한국정밀공학회지
    • /
    • 제17권5호
    • /
    • pp.124-130
    • /
    • 2000
  • For measuring out the submicron order straightness, a precision measuring device is developed in this paper. The device is constructed with a hydrostatic feed table and a capacitive type sensor which is mounted to the feed table. Straightness is acquired as substracting the motion error of feed table from the measured profile with probe. Motion error of feed table is simultaneously compensated upto 0.120${\mu}{\textrm}{m}$ of linear motion error and 0.20arcsec of angular motion error using the active controlled capillary. Reversal method and strai호t-edge is used fur estimating the measuring accuracy and from the experimental result, it is verified that the device has the measuring accuracy 0.030m. Also, through the practical application on the measurement of ground surface, it is confirmed that the device is very effective to measure the submicron order straightness.

  • PDF

캐패시턴스형 센서를 사용한 자기베어링-축계의 진동특성 연구 (A Vibration Characteristic Research of Rotor-Magnetic Bearing System Measured by Capacitance Type Sensors)

  • 이상호;정성천;장인배;한동철
    • Tribology and Lubricants
    • /
    • 제10권4호
    • /
    • pp.27-32
    • /
    • 1994
  • The capacitive type transducers measure the displacement of rotating shaft using the voltage difference which is formed between the sensor plates and rotor so that the measured signal is not affected by the magnetic field generated by the magnetic bearing. In this paper, the capacitive transducers are embedded inside of the magnetic bearing. In order to verify the support characteristics of the capacitance sensor-magnetic bearing system, we experimented and analyzed the magnetic bearing-rotating shaft system up to 12,000 rpm. The magnetic bearing system proposed in this paper, successfully supports the rotating shaft and we can remain the maximum displacement below $5 \mu m$ at 12,000 rpm.

Microfabrication of MEMS Cantilevers for Mechanically Detected High-Frequency ESR Measurement

  • Ohmichi, E.;Yasufuku, Y.;Konishi, K.;Ohta, H.
    • Journal of Magnetics
    • /
    • 제18권2호
    • /
    • pp.163-167
    • /
    • 2013
  • We fabricated prototype cantilevers for mechanically detected high-frequency ESR measurement. Cantilevers are fabricated from silicon-on-insulator (SOI) wafers using standard MEMS techniques such as lithography, wet etching, and plasma etching. Using commercial SOI wafers, fabrication cost and the number of processes can be substantially reduced. In this study, three types of cantilevers, designed for capacitive and optical detection, are shown. Capacitive type with lateral dimensions of $3.5{\times}1.6mm^2$ is aimed for low spin concentration sample. On the other hand, optical detection type with lateral dimensions of $50{\times}200{\mu}m^2$ is developed for high-sensitive detection of tiny samples such as newly synthesized microcrystals.

몰드변압기에서 부분방전 검출방법의 비교분석 (Comparison Analysis of Partial Discharge Detection Methods in Cast Resin Dry Type Transformers)

  • 박찬용;김성욱;최재성;박대원;길경석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.301-306
    • /
    • 2008
  • Various sensors such as capacitive probe, high frequency current transformer (HFCT), and acoustic emission (AE) probe were applied to a cast resin dry type transformer for partial discharge detection. We designed and fabricated a wideband low-noise amplifier having a gain of 40[dB]. From the experiment which was carried out in the same transformer, the sensitivities were 7.16[mV/pC] for capacitive probe, 3.8[mV/pC] for HFCT, and 17.9[mV/pC] for AE probe.

  • PDF

MEMS 기반 안전 소자에 대한 액정 폴리머 패키지의 밀폐도 연구 (Investigation on Hermeticity of Liquid Crystal Polymer Package for MEMS Based Safety Device)

  • 최진일;김용국;주병권
    • 센서학회지
    • /
    • 제24권5호
    • /
    • pp.287-290
    • /
    • 2015
  • Liquid crystal polymer (LCP) is a thermoplastic polymer with superior mechanical and thermal properties. In addition, its characteristics include very low water absorption rate and possibility to apply bonding process under low temperature. In this study, LCP is utilized as a packaging material for a microelectronic system (MEMS) based safety device with suggestion of a low temperature packaging process. Highly sensitive and stable capacitive type humidity sensor is fabricated to investigate hermeticity of the packaged MEMS device.

실린더형 정전용량 센서 및 변위 측정시스템 설계 (Design of Stroke Measurement System and Cylinder-type Capactive Sensor)

  • 이재건;이인곤;박성균;홍익표
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.910-912
    • /
    • 2015
  • 본 논문에서는 중장비나 댐의 수문 등의 적용된 유압 실린더의 변위(stroke)를 검출하여 유압 실린더의 정밀제어 또는 자동화를 위한 정전용량 센서(Capacitive Sensor) 및 변위 검출 시스템을 설계하였다. 기존 실린더의 변위 검출 방식인 코일을 이용한 자기장 센서, LVDT 센서 등은 높은 정확도에 비해 충격 및 진동 완화 또는 센서 보호 하우징(Housing) 등 부수적인 설비에 따른 높은 비용, 큰 부피와 같은 문제가 있다. 따라서 이러한 개선하기 위해 유압 실린더 내의 직접 적용되어 실린더의 변위 검출이 가능한 정전용량 센서를 설계하였으며, 설계한 정전용량 센서를 통하여 실린더의 변위에 따른 커패시턴스 값을 검출하여 실린더 위치 측정이 가능한 시스템을 설계 및 검증 하였다.

  • PDF

압전저항형 멤스센서를 이용한 진동 측정용 3축 센서 시스템의 최적화 설계 (Optimum Design of 3-Axis Sensor System for Vibration Measurement Using Piezoresistive type MEMS Sensor)

  • 서상윤;배동명;이종규;최병근
    • 한국소음진동공학회논문집
    • /
    • 제23권12호
    • /
    • pp.1082-1089
    • /
    • 2013
  • 3-Axis sensor measurement system is needed for measuring ride quality of elevator. But because 3-Axis piezoelectric accelerometer is expensive. We developed 3-Axis sensor system which is suitable for measuring ride quality of elevator using cheap MEMS sensor. There are two types of MEMS sensor that are piezoresistive and capacitive type. The excellence of piezoresistive type in characteristic of frequency response and noise is confirmed compare to capacitive type as a result of this paper's experiment and reference. 3-Axis system using MEMS sensor needs MEMS's proper frequency response characteristic. Additionally noise characteristic of sensor and circuit, stiffness of assembly are needed for deciding frequency range and accuracy of amplitude.

폴리(페닐렌에테르설폰)을 이용한 용량형 습도센서의 제조 (Fabrication of Capacitive-Type Humidity Sensor with Poly(p-phenylene ether sulfone))

  • 조재익;최균;김창정;김병익;박승현;방기석
    • 폴리머
    • /
    • 제30권3호
    • /
    • pp.207-209
    • /
    • 2006
  • ITO 코팅 글라스를 기판으로 사용하고 폴리(페닐렌에테르설폰)(PES)을 감습막으로 하여 정전용량형 습도센서를 제작하였다. 감습막은 PES를 m-cresol에 용해한 후 스핀코팅으로 제조하였고 그 상부에 다공성 Au막을 스퍼터링으로 증착하였다. 상대습도 $20\sim90%$의 범위에서 센서의 용량은 감습막두께에 반비례하였고 1% 미만의 비선형 특성을 나타내었다. 또한 $1.4{\mu}m$ 두께의 샘플에서는 20 kHz에서 1.3%의 히스테리시스와 1.14의 우수한 감도를 얻을 수 있었다.

A 5-17 GHz Wideband Reflection-Type Phase Shifter Using Digitally Operated Capacitive MEMS Switches

  • Kim, Jung-Mu;Lee, Sang-Hyo;Park, Jae-Hyoung;Baek, Chang-Wook;Kwon, Young-Woo;Kim, Yong-Kweon
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2003년도 추계학술대회 발표 논문집
    • /
    • pp.117-121
    • /
    • 2003
  • In this paper, a micromachined low-loss and ultra wide band reflection-type phase shifter (RTPS) is proposed. The phase shifter shows a constant phase shift from 5 to 17 GHz and consists of two cascaded reflection-type phase shifter. Low-loss reflection termination consists of digital capacitive switches, and air-gap overlay CPW couplers are used in order to employ the low-loss 3 dB coupling. The fabricated phase shifter showed the 5 discrete states, $0^{\circ},{\;}22.5^{\circ},{\;}45^{\circ},{\;}67.5^{\circ},{\;}90^{\circ}$ respectively, the average insertion loss of 3.48 dB, and maximum rms phase error of ${\pm}1.80^{\circ}$ for the relative phase shift from $0^{\circ}{\;}to{\;}90^{\circ}$ over 5-17 GHz.

  • PDF