A Study on the Investigation of Performance for Evaluation Method of Unit Water Content of Fresh Concrete (굳지 않은 콘크리트 단위수량 추정기법의 성능 검토에 관한 연구)

  • Kim, Yong-Ro;Choi, Il-Ho;Jung, Yang-Hee;Kim, Hyo-Rak;Lee, Do-Bum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.367-370
    • /
    • 2005
  • In this study, air meter method and capacitance measurement method to apply economically at quality control of ready-mixed concrete among various unit water content measurement technique was selected. Then, it was evaluated estimating performance of unit water content according to the change of water-binder ratio and unit water content. Also, it was examined influence about error occurrence of unit water content by change of properties of used materials. Finally, based on this study, it was proposed fundamental data to utilize measurement technique of unit water content to quality control. of ready-mixed concrete in construction field.

  • PDF

Adaptive Nonlinearity Compensation in Laser Interferometer using Neural Network (신경망 회로를 이용한 레이저 간섭계의 적응형 오차보정)

  • Heo, Gun-Hang;Lee, Woo-Ram;You, Kwan-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.86-88
    • /
    • 2007
  • In the semiconductor manufacturing industry, the heterodyne laser interferometer plays as an ultra-precise measurement system. However, the heterodyne laser interferometer has some unwanted nonlinearity error which is caused from frequency-mixing. This is an obstacle to improve the measurement accuracy in nanometer scale. In this paper we propose a compensation algorithm based on RLS(recursive least square) method and artificial intelligence method, which reduce the nonlinearity error in the heterodyne laser interferometer. With the capacitance displacement sensor we get a reference signal which can be transformed into the intensity domain. Using the back-propagation Neural Network method, we train the network to track the reference signal. Through some experiments, we demonstrate the effectiveness of the proposed algorithm in measurement accuracy.

  • PDF

Measurement of High Voltage Capacitor in On-line System (실시스템에서의 고압용 진상용 캐패시터 특성시험)

  • Song, Sang-Hoon;Seo, Min-Sung;Yu, Woo-Sun;Jo, Sung-Soo;Won, Chung-Yuen
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2319-2321
    • /
    • 2002
  • This paper suggests a computer-based on-line measurement method of tan$\delta$ and capacitance for HV capacitor. The method employs V-I technique using scaled down analog voltage and current signal obtained by digital oscilloscope. The measurement results are displayed by graphic user interface with graphic language. Field tests were tarried out at 6.6kV testing voltage in Samhwa Capacitor company.

  • PDF

An Ultra-precision Electronic Clinometer for Measurement of Small Inclination Angles

  • Tan, Siew-Leng;Kataoka, Satoshi;Ishikawa, Tatsuya;Ito, So;Shimizu, Yuuki;Chen, Yuanliu;Gao, Wei;Nakagawa, Satoshi
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.6
    • /
    • pp.539-546
    • /
    • 2014
  • This paper describes an ultra-precision electronic clinometer, which is based on the capacitive-based fluid type, for detection of small inclination angles. The main parts of the clinometer low-noise electronics are two capacitance measurement circuits for converting the capacitances of the capacitors of the clinometer into voltages, and a differential amplifier for obtaining the difference of the capacitances, which is proportional to the input inclination angle. A 16 bit analog to digital (AD) converter is also embedded into the same circuit board, whose output is sent to a PC via RS-232C, for achieving a small noise level down to tens of ${\mu}v$. A compensation method, which is referred to as the delay time method for shortening the stabilization time of the sensor was also discussed. Experimental results have shown the possibility of achieving a measurement resolution of $0.0001^{\circ}$ as well as the quick measurement with the delay time method.

Development of axial tomography technique for the study of steam explosion (증기폭발 적용 축방향 토모그라피 기술 개발)

  • Seo, Si-Won;Ha, Kwang-Soon;Hong, Seong-Wan;Song, Jin-Ho;Lee, Jae-Young
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3027-3032
    • /
    • 2007
  • To understand the complex phenomena performed in steam explosion, the fast and global measurement of the steam distribution is imperative for this extremely rapid transient stimulation of the bubble breakup and coalescence due to turbulent eddies and shock waves. TROI, the experimental facility requests more robust sensor system to meet this requirement. In Europe, researchers are prefer a X-ray method but this method is very expensive and has limited measurement range. There is an alternative technology such as ECT. Because of TROI's geometry, however, we need axial tomography method. This paper reviews image reconstruction algorethms for axial tomography, including Tikhonov regularization and iterative Tikhonov regularization. Axial tomography method is examined by simulation and experiment for typical permittivity distributions. Future works in axial tomography technology is discussed.

  • PDF

Dielectric Loss Tangent Measurement Using the $Al_{2}O_{3}$ Crystal Capacitor ($Al_{2}O_{3}$ Crystal Capacitor를 이용한 유전손실 측정)

  • Kim, Kwang-Soo;Her, In-Sung;Lee, Chong-Chan;Park, Dea-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.109-122
    • /
    • 2002
  • The standard capacitor must have not only precise value of the capacitance but also the basic properties of low dielectric loss tangent. In the reforming process of capacitors, the dielectric loss tangent must be also reformed. In this paper, the development of standard capacitors of 10 and 100pF for the dielectric loss tangent standard using $Al_{2}O_{3}$ Crystal and the measurement of dielectric loss tangent are discussed. The dielectric loss tangent depends upon the surface between electrode and dielectric in capacitor. With using the Electric Field Simulator, precise design values of electrode are simulated. For the purpose of measuring capacitance effect just in the dielectric, 3-Terminal and 4-Terminal Pair configuration are applied respectively at the electrode and the connector for the measuring equipment. As stated above method, the standard capacitors of 10 and l00pF for the establishment of the dielectric loss tangent standard using the $Al_{2}O_{3}$ Crystal are made with low dielectric loss tangent less than 10-4.

  • PDF

Development of a national medium vacuum standard by static expansion method (정적법을 이용한 중진공 국가표준기 개발)

  • Hong S. S.;Lim I. T.;Shin Y. H.;Chung K. H.
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.2
    • /
    • pp.59-68
    • /
    • 2005
  • We developed a national medium vacuum standard by static expansion method. A 133 Pa capacitance diaphragm gauge was calibrated and analysed according to the document of 'Guide to the Expression of Uncertainty in Measurement' of ISO. The results showed that the expanded uncertainty of $2.628\times10^{-3}$ Pa at $95\%$ confidence level and coverage factor of k=2.

A Useful Technique for Measuring the 3-dimensional Positioning of a Rotating Object (회전체의 효과적인 3차원 위치오차 측정방법)

  • Lee, Eung-Seok;Wi, Hyeon-Gon;Jeong, Ju-No
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.6
    • /
    • pp.918-924
    • /
    • 1997
  • A method for measuring the accuracy of rotating objects was studied. Rotating axis errors are significant; such as the spindle error of a manufacturing machine which results in the surface roughness of machined work pieces. Three capacitance type displacement sensors were used to measure the rotating master ball position. The sensors were mounted to the three orthogonal points on the spindle axis. The measurement data were analyzed and shown for rotating spindle accuracy, not only for average roundness error but also for spindle volumetric positional error during the revolutions. This method is simple and economical for industrial field use with regular inspection of rotating machines using portable equipment. Measuring and analyzing time using this method takes only a couple of hours. This method can also measure microscopic amplitude and 3-dimensional direction of vibrating objects.

A New Method for Extracting Interface Trap Density in Short-Channel MOSFETs from Substrate-Bias-Dependent Subthreshold Slopes

  • Lyu, Jong-Son
    • ETRI Journal
    • /
    • v.15 no.2
    • /
    • pp.11-25
    • /
    • 1993
  • Interface trap densities at gate oxide/silicon substrate ($SiO_2/Si$) interfaces of metal oxide semiconductor field-effect transistors (MOSFETs) were determined from the substrate bias dependence of the subthreshold slope measurement. This method enables the characterization of interface traps residing in the energy level between the midgap and that corresponding to the strong inversion of small size MOSFET. In consequence of the high accuracy of this method, the energy dependence of the interface trap density can be accurately determined. The application of this technique to a MOSFET showed good agreement with the result obtained through the high-frequency/quasi-static capacitance-voltage (C-V) technique for a MOS capacitor. Furthermore, the effective substrate dopant concentration obtained through this technique also showed good agreement with the result obtained through the body effect measurement.

  • PDF

Development of Sheet Metal Forming Apparatus Using Electromagnetic Lorentz Force (전자기 로렌쯔력을 이용한 박판성형 장비 개발)

  • Lee, H.M.;Kang, B.S.;Kim, J.
    • Transactions of Materials Processing
    • /
    • v.19 no.1
    • /
    • pp.38-43
    • /
    • 2010
  • Electromagnetic forming (EMF) method is one of high-velocity forming processes, which uses electromagnetic Lorentz force. Advantages of this forming technique are summarized as improvement of formability, reduction in wrinkling, non-contact forming and applications of various forming process. In this study, the EMF apparatus is developed. It is designed to be stored in 10 capacitors connected in parallel, each with a capacitance of $50{\mu}F$ and maximum working voltage of 5kV. The system has capacitance of $500{\mu}F$ and maximum stored energy of 6.25kJ. And EMF experiments are carried out to verify the feasibility of the EMF apparatus, which has enough forming force from the results of EMF experiment. In addition, peak current carrying a forming coil is predicted from theoretical background, and verified the predicted value compared with experimental value using the current measurement equipment. Consequently, EMF apparatus developed in this study can be applied to various EMF researches for commercialization.