• Title/Summary/Keyword: candidate materials

Search Result 803, Processing Time 0.036 seconds

Selection of Candidate Materials and their Prioritization for Chronic Inhalation and Carcinogenicity Test (흡입노출에 의한 만성·발암성시험 대상물질 및 우선순위 선정 연구)

  • Rim, Kyung-Taek;Lim, Cheol-Hong;Ahn, Byung-Joon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.587-612
    • /
    • 2014
  • Objectives: There is requirement to select candidate materials for chronic inhalation/carcinogenicity testing, so we would like to set the priority of candidate materials. Methods and Results: We recommend the priorities for candidate materials based on the chemicals stipulated in the Occupational Safety and Health Act(OSHAct) and the Toxic Chemicals Control Act(TCCA) in Korea. Conclusions: We presented candidate chemicals consisting of solids(powders), gases and liquids(Such as organic solvents) with priorities.

A Study on the Development of Soil-based PTMs for Analysis of BTEX (BTEX 분석용 토양 숙련도 표준시료(PTMs) 개발에 관한 연구)

  • Lee, Minhyo;Lee, Guntaek;Lee, Bupyoel;Lee, Wonseok;Kim, Gumhee;Hong, Sukyoung
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.5
    • /
    • pp.15-25
    • /
    • 2013
  • In this study, two kinds of soil-based proficiency testing materials (PTMs), NICE-012L and NICE-012R were prepared and certified for Benzen, Toluene, Etylbenzene and Xylene with evaluation of uncertainties. In order to analyse BTEX (Benzen Toluene Etylbenzene Xylene) for the candidate materials, GC/MS was used after pretreatment according to methods of soil analysis by Ministry of Environment. For the homogeneity test among bottles in terms of candidate materials, ISO 13528 and IUPAC Protocol were used and according to the result, both candidate materials showed sufficient homogeneity. Also, the stability test over the candidate materials was accessed according to the ISO Guide 35 by classifying short-term and long-term stability and the result showed that both candidate materials showed decent stability. The reference values of the two candidate materials depending on BTEX components were derived from the average of the 11 samples that were used for verification of the samples' homogeneity. Uncertainty of measurement was combined by uchar that was caused by a characteristic value, $u_{bb}$ that was caused by between-bottle homogeneity, and $u_{stab}$ that was caused by stability, and then combined uncertainty ($u_{PTM}$) was multiplied to the coverage factor (k) derived from the effective degree of freedom from each factor that leads to expanded uncertainty (U) in about 95% of confidence level. The proficiency testing materials developed through this study were supplied to National Institute of Environmental Research (NIER) and utilized as an external proficiency testing materials for evaluating analysis capacity of soil agencies with specialty in terms of soil analysis approved by Minister of Environment.

Feasibility for Ultrasound Pad Material for the Evaluation Axillary Region of Automated Breast Ultrasound Equipment (자동유방초음파 장비의 액와부 평가를 위한 초음파 패드 물질의 타당성)

  • Seo, Eun-Hee;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.41 no.3
    • /
    • pp.231-240
    • /
    • 2018
  • Automated breast ultrasound (ABUS) equipment is a new innovative technique for 3D automatic breast scanning, but limited for the examination in the concave axillary region. The purpose of this study was to determine feasible candidate materials for the ultrasonic wave propagation media in ABUS, enabling the evaluation of the axillary region. Ultrasonography was performed using an ABUS system ($Invenia^{TM}ABUS$, GE, USA) on the ultrasound-specific phantom (UC-551M-0.5, ATS Laboratories, USA) covered by different candidate materials. The validity of feasible candidate materials was evaluated by image quality. Three independent radiological technologists, with more than 10 years of experience, visually assessed on the images. The inter-observer agreements according to the candidate materials were tested using Cronbach's alpha. Unenveloped solidified carrageenan can be a feasible material for the use of ABUS with excellent test reliability. Therefore, the coverage of the axillary region with carrageenan may be effective for ABUS which was originally developed for the convex anatomic structure as female breast.

A Study on the Development of Soil-based PTMs for Analysis of Benzo[a]pyrene - Focusing on the Evaluation of Homogeneity and Stability for the Certification of Benzo[a]pyrenecandidate Reference Materials - (Benzo[a]pyrene 분석용 토양 숙련도 표준시료 개발에 관한 연구 - 후보 표준물질의 인증을 위한 균질성, 안정성 평가를 중심으로 -)

  • Lee, Minhyo;Lee, Guntaek;Joo, Changkyu;Kim, Yonghun;Lee, Bupyoel;Choe, Sunghun;Kim, Myeongock;Hong, Sukyoung;Kim, Gumhee;Lee, Wonseok
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.6
    • /
    • pp.49-58
    • /
    • 2014
  • This study was implemented as a part of the experiment to develop two kinds of soil-based Benzo[a]pyrene (BaP) proficiency testing materials (PTMs) for soil analysis. A test was carried out for the check of solubility of the reference material (high purity reagent) using several solvents. Another test was also conducted for the evaluation of homogeneity and stability of two kinds of candidate soil reference materials. The test analysis of BaP in terms of the candidate materials was conducted according to the Standard Soil Analytical Methods by Ministry of Environment. Dissolution of the reference material was shown to vary depending on solvent type and was higher in the order of Dichloromethane > Acetone > Acetone/MeOH (9 : 1) > N-hexane. In addition, the slope on calibration curve for BaP standard solutions was largest on BaP standard solutions prepared with dichloromethane of the tested solvents. Such tendency appeared egually in the commercial BaP standard solution. Therefore, it is thought to be reasonable to use dichloromethane as the solvent in case of the standard stock solution that is used for the measurement of BaP concentration in soil. ISO 13528 and IUPAC protocol were used for verification of homogeneity on the two kinds of soil candidate materials, Both candidate materials were sufficiently homogeneous. Stability assessment of the two candidate materials was made according to ISO Guide 35 and the result showed that both batches did not have any long-term and short term stability issues that might occur during shipping. However, monitoring results of BaP concentration in soil showed that BaP concentration of the two batches measured at 15 days after the sample preparation was reduced by about 24~37% compared with that of the samples measured on 0 day of the sample preparation. Identification was done with several treatments such as irradiation and sterilization etc. The major cause was shown to be irradiation to the samples.

A Study on the Recommendation of the Candidate Substances and Methods for an Additional Designation of Special Management Materials in Occupational Safety and Health Act(OSHA) (산업안전보건법 특별관리물질의 추가 지정방법 및 후보물질 권고에 관한 연구)

  • Lee, Kwon Seob;Hong, Mun Ki;Lee, Hye Jin;Byeon, Sang-Hoon;Park, Jung Sun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.1
    • /
    • pp.91-102
    • /
    • 2014
  • Objectives: This study was performed in order to devise a procedure for supplementing the Special Management Materials in the Occupational Safety and Health Act and recommend candidate materials. The results are expected to be used as fundamental data for classification and criteria necessary to manage Special Management Materials in workplaces. Also, they are expected to be used as a basis for selecting target materials to nominate as additional Special Management Material. Methods: We investigated the selection standards for candidates and review ranges of data sources to nominate Special Management Materials. The substances classified as GHS(Globally Harmonized System of classification and labeling of chemicals) category 1A(known to have carcinogenic potential and reproductive toxicity for humans) or 1B(presumed to have carcinogenic potential and reproductive toxicity for humans) carcinogens and reproductive toxicants among the Controlled Hazardous Substances of the Regulation on Occupational Safety and Health Standards and substances with OELs(Occupational Exposure Limits) were inspected as the candidates for Special Management Materials. Conclusions: A seven-step procedure for selecting candidates to designate as Special Management Materials was suggested, including the setting of target chemicals for evaluation, classification of CMR(Carcinogens, Mutagens or Reproductive toxicants) by GHS classification and criteria, suggestion and selection of the candidates, and more. This study recommends 58 chemicals as qualified candidates to supplement the Special Management Materials.

Combinatorial Synthesis and Screening of the Eu-activated Phosphors in the System MO-$Al_2O_3-SiO_2$(M=Sr, Ba)

  • Yoon, Ho-Shin;Park, Jung-Kyu;Kim, Chang-Hae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.650-653
    • /
    • 2004
  • We have synthesized some phosphors in the system MO-$Al_2O_3-SiO_2$(M=Sr, Ba) by combinatorial polymerized-complex method. Composition and synthetic temperature of phosphors in the liblary was screened from the emission intensities of individual samples under 365nm excitation. As we were screened the higher luminescent candidate composition (or candidate host lattice) at 365nm excitation, investigated whether good radiation was possible at the 405 or 465nm excitation by give the host lattice to be discovered more various change. From libraries about 2 systems, the compound to be expected in long wavelength among the compound to be screened are $Sr_4Al_{14}O_{25}$, $Sr_3Al_2O_6$, $SrAl_2Si_2O_8$, and $BaAl_2Si_2O_8$.

  • PDF

First-Principles Calculations for Design of Efficient Electrocatalysts (제일원리 계산을 활용한 전기화학 촉매 연구)

  • Kim, Dong Yeon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.6
    • /
    • pp.393-400
    • /
    • 2021
  • As the recent climate problems are getting worse year after year, the demands for clean energy materials have highly increased in modern society. However, the candidate material classes for clean energy expand rapidly and the outcomes are too complex to be interpreted at laboratory scale (e.g., multicomponent materials). In order to overcome these issues, the first-principles calculations are becoming attractive in the field of material science. The calculations can be performed rapidly using virtual environments without physical limitations in a vast candidate pool, and theory can address the origin of activity through the calculations of electronic structure of materials, even if the structure of material is too complex. Therefore, in terms of the latest trends, we report academic progress related to the first-principles calculations for design of efficient electrocatalysts. The basic background for theory and specific research examples are reported together with the perspective on the design of novel materials using first-principles calculations.

Construction of Indole Library for Serotonin Related Drugs and Macrocyclization Using Selenium Chemistry in Solid-Phase Reaction.

  • Mun, Han-Seo;Jeong, Jin-Hyun
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.246.1-246.1
    • /
    • 2003
  • Hetero chain compounds have high possibilities of being good medicinal candidate because of their well-known medicinal activity and relatively low subtitled carbon. By constructing the method of making this compound library, this research has the purpose to create a new medicinal candidate materials based on an easy medicinal search. The first step is to construct an Indole library in a compounding process with the design of a linker connecting a solid-state resin and a substrate. (omitted)

  • PDF

Development of Certified Reference Materials for Analysis of Heavy Metals in Paints to Cope with Environmental Regulations (환경규제 대응을 위한 페인트 중의 중금속 분석용 인증 표준물질 개발)

  • Yu, Byung Kyu;Sun, Yle Shik
    • Journal of Environmental Analysis, Health and Toxicology
    • /
    • v.21 no.4
    • /
    • pp.209-219
    • /
    • 2018
  • In the areas of RoHS, WEEE, ELV and REACH, reinforcement of environmental regulations against harmful substances is a global trend not only in EC but also in all over the world. In the fields of Korea's major export products such as material parts, electrical and electronic products and automobile parts, we are responding to these regulations consistently. To develop reference material for analyzing lead and cadmium in paints, the candidate materials were produced through the screening process which separated shapes and sizes. To secure the traceability of the candidate materials produced, the characteristics and uncertainties are estimated by ICP-AES analysis using the primary reference material. The short-term and long-term stabilities also are evaluated in parallel. In order to calculate the final certification value of the candidate material, the verification were carried out by the performance evaluation through the comparison among the KOLAS (Korea Laboratory Accreditation Scheme) laboratories, and the CRM was produced in accordance with ISO Guide 35. The certified values and uncertainties of Pb and Cd of the final paint standard, determined according to the joint analysis among laboratories, are Pb [($191.4{\pm}3.1$) mg/kg, ($944.1{\pm}5.6$) mg/kg] and Cd [($45.0{\pm}2.6$) mg/kg, ($225.5{\pm}3.5$) mg/kg]. These standard materials were developed to enhance the reliability of measurement analysis, including the validity and traceability of measurement results. Also it is expected that the CRM will be used as QCM (quality control material) for the product design and the process monitoring, so that regulation and management of hazardous heavy metals can be systematically implemented.