• 제목/요약/키워드: cancer tissue engineering

검색결과 168건 처리시간 0.025초

Anti-Invasive and Anti-Angiogenic Effects of Xanthohumol and Its Synthetic Derivatives

  • Kim, Jung-Ae;Kang, You-Ra;Thapa, Dinesh;Lee, Jong-Suk;Park, Min-A;Lee, Kyung-Hee;Lyoo, Won-Seok;Lee, Yong-Rok
    • Biomolecules & Therapeutics
    • /
    • 제17권4호
    • /
    • pp.422-429
    • /
    • 2009
  • Invasion and metastasis is the main cause of cancer mortality. Angiogenesis is a prerequisite for the tumor growth and metastasis. Matrix metalloproteinases (MMPs) are the key enzymes playing in the invasive growth and metastasis of cancer as well as angiogenesis. Xanthohumol, a prenylated chalcone of the Hop plant (Humulus lupulus L), has been reported to suppress cancer invasion and angiogenesis. In the present study, we investigated the antiinvasive effects of xanthohumol (1) and its synthetic derivatives, 4'-O-methylxanthohumol SEM ether (2), xanthohumol C (3), and xanthohumol C MOM ether (4) in relation to MMP expression in HT-1080 human fibrosarcoma cells. The compound 1 and its derivative, 3 and 4, significantly inhibited serum-induced HT-1080 cell invasion, and 12-O-tetradecanoylphorbol-13-acetate (TPA)-enhanced activity and expression level of MMP-2 and MMP-9 in a concentration-dependant manner. In addition, they inhibited TPA-enhanced expression of MT1-MMP with relatively weak inhibition in tissue inhibitor of metalloproteinase (TIMP)-1 and TIMP-2 level. The compound 1 significantly decreased the cell viability, whereas the derivatives, 2 and 3 showed no cytotoxicity, and compound 4 showed slight cytotoxicity in the cells. Furthermore, in a chick chorioallantoic membrane (CAM) assay, the derivatives 3 and 4 dose-dependently suppressed vascular endothelial growth factor (VEGF)-induced angiogenesis, which is similar to that of compound 1. Taken together, the results indicate that compounds 3 and 4 may be valuable anti-angiogenic agents in the treatment of chronic diseases such as cancer and inflammation working through suppression of MMP-2 and MMP-9.

A Multi-detection Fluorescence Dye with 5-ALA and ICG Using Modified Light Emitting Diodes

  • Yoon, Kicheol;Kim, Eunji;Kim, Kwanggi;Lee, Seunghoon;Yoo, Heon
    • Current Optics and Photonics
    • /
    • 제3권3호
    • /
    • pp.256-262
    • /
    • 2019
  • Extensive tumor resection accompanied by radiotherapy and chemotherapy is the standard of care for malignant gliomas. However, there is a significant obstacle to the complete resection of the tumor due to the difficulty of distinguishing tumor and normal brain tissue with a conventional surgical microscope. Recently, multiple studies have shown the possibility of fluorescence-guided surgery in malignant gliomas. The most used fluorescence dyes for brain tumor surgery are 5-aminolevulinic acid (5-ALA) and indocyanine green (ICG). In this paper, a new fluorescence guided operation system, which can detect both 5-ALA and ICG fluorescent images simultaneously, is presented. This operation system consists of light emitting diodes (LEDs) which emits 410 nm and 740 nm wavelengths. We have performed experiments on rats in order to verify the operation of the newly developed operation system. Oral administration and imaging were performed to observe the fluorescence of 5-ALA and ICG fluorescence in rats. When LEDs at wavelengths of 410 nm and 740 nm were irradiated on rats, 628 nm wavelength with a violet fluorescence color and 825 nm wavelength with a red fluorescence color were expressed in 5-ALA and ICG fluorescent material, respectively, thus we were able to distinguish the tumor tissues easily. Previously, due to the poor resolution of the conventional surgical microscope and the fact that the color of the vein is similar to that of the tumor, the tumor resection margin was not easy to observe, thus increasing the likelihood for cancer recurrence. However, when the tumor is observed through the fluorescence guided operation system, it is possible to easily distinguish the color with the naked eye and it can be completely removed. Therefore, it is expected that surgical removal of cancerous tumors will be possible and surgical applications and surgical microscopes for cancer tumor removal surgery will be promising in the future.

Dosimetric Evaluation of Low-Dose Spillage Volumes for Head and Neck Cancer Using Intensity-Modulated Radiation Therapy and Volumetric Modulated Arc Therapy Treatment Techniques

  • Kumar, Gourav;Bhushan, Manindra;Kumar, Lalit;Kishore, Vimal;Raman, Kothanda;Kumar, Pawan;Barik, Soumitra;Purohit, Sandeep
    • 한국의학물리학회지:의학물리
    • /
    • 제32권3호
    • /
    • pp.70-81
    • /
    • 2021
  • Purpose: This study was designed to investigate the dosimetric difference between intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) in head and neck cancer (HNC). The study primarily focuses on low-dose spillage evaluation between these two techniques. Methods: This retrospective study involved 45 patients with HNC. The treatment plans were generated using the IMRT and VMAT techniques for all patients. Dosimetric comparisons were performed in terms of target coverage, organ-at-risk (OAR) sparing, and various parameters, including conformity index, uniformity index, homogeneity index, conformation number, low-dose volumes, and normal tissue integral dose (NTID). Results: No significant (P>0.05) difference in planning target volume coverage (D95%) was observed between IMRT and VMAT plans for supraglottic larynx, hard palate, and tongue cancers. A decrease in dose volumes ranging from 1 Gy to 30 Gy was observed for VMAT plans compared with those for IMRT plans, except for V1Gy and V30Gy for supraglottic larynx cancer and V1Gy for tongue cancer. Moreover, decreases (P<0.05) in NTID were observed for VMAT plans compared with that for IMRT plans in supraglottic larynx (4.50%), hard palate (12.80%), and tongue (7.76%) cancers. In contrast, a slight increase in monitor units for VMAT compared with those for IMRT in supraglottic larynx (0.46%), hard palate (2.54%), and tongue (7.56%) cancers. Conclusions: For advanced-stage HNC, both IMRT and VMAT offer satisfactory clinical plans. VMAT offers a conformal and homogeneous dose distribution with comparable OAR sparing and higher dose falloff outside the target volume than IMRT, which provides an edge to reduce the risk of secondary malignancies for HNC over IMRT.

양성자 치료 전산모사를 위한 Geant4 전자기 물리 모델 정확성 검증 (Precision Validation of Electromagnetic Physics in Geant4 Simulation for Proton Therapy)

  • 박소현;라정은;신정욱;박성용;윤세철;정원균;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제20권4호
    • /
    • pp.225-234
    • /
    • 2009
  • Geant4 toolkit은 전자기적 상호작용(electromagnetic interactions)에 대한 다양한 물리적 모델을 제공한다. 이러한 물리적 모델들에 대한 검증은 신뢰성 있는 Geant4 응용을 위해서 중요한 역할을 한다. 그러므로, 본 연구의 목적은 양성자 치료 전산모사를 위해 Geant4가 제공하는 물리적 모델 중 전자기 물리 모델의 정확성을 검증하는 것이다. 검증은 물, 뼈, 지방 그리고 원자번호가 다른 물질에 대해 양성자의 CSDA 비정(continuous slowing down approximation range)과 저지능(stopping power) 데이터를 미국 국립기술표준원(National Institute of Standards and Technology, NIST)의 데이터를 각각 비교하는 방법으로 이루어졌다. 물, 뼈 그리고 지방에 대해 0.01 MeV에서 10 GeV 범위의 입사 에너지의 CSDA 비정과 저지능 전산모사 결과와 NIST값을 비교한 결과, CSDA 비정의 평균 차는 각각 1.0%, 1.4% 그리고 1.4%를 나타내었고, 저지능에 대한 평균 차는 각각 0.7%, 1.0% 그리고 1.3%를 나타내었다. 또한, 각 물질에 대한 NIST 값과의 유의성을 분석하기 위해 kolmogorov-smirnov Goodness-of-Fit 통계분석 방법을 이용한 결과, 전자기 물리 모델의 전산모사 결과 데이터와 NIST 데이터 사이의 유의성을 나타내는 p-value가 유의 수준 0.05 이상 값을 가진다는 것을 확인 하였으며, 이를 통해 Geant4 전자기 물리 모델의 정확성을 검증할 수 있었다.

  • PDF

Photon dose response functions for accurate skeletal dosimetry for Korean and Asian populations

  • Bangho Shin;Chansoo Choi;Rui Qiu;Suhyeon Kim;Hyeonil Kim;Sungho Moon;Gahee Son;Jaehyo Kim;Haegin Han;Yeon Soo Yeom;Chan Hyeong Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2195-2207
    • /
    • 2024
  • To enhance skeletal dosimetry in conjunction with the adult mesh-type reference Korean phantoms (MRKPs), Korean/Asian photon fluence-to-skeletal dose response functions (DRFs) were established utilizing an updated version of micro-CT-based detailed bone models from Tsinghua University. These bone models were incorporated into the MRKPs using the parallel geometry feature of Geant4. We calculated bone-site-specific electron absorbed fractions and used them to generate DRFs, following a similar methodology employed for ICRP-116 DRFs that have been used with the ICRP reference phantoms for skeletal dosimetry. To assess dosimetric implications of the Korean/Asian DRFs, we calculated RBM and BE doses for the MRKPs exposed to photon beams in the antero-posterior direction using the Korean/Asian and ICRP-116 DRFs. For energies ≥200 keV, the Korean/Asian DRFs-based skeletal doses exhibited excellent agreement with the ICRP-116 DRFs-based skeletal doses, attributed to the existence of charged particle equilibrium across the bone site. Conversely, significant differences of up to ~2.3 times were observed at lower energies, due to differences in the skeletal tissue distributions of bone models used to derive the Korean/Asian and ICRP-116 DRFs. The DRFs established in this study are expected to yield more accurate skeletal doses for Korean and Asian populations compared to the ICRP-116 DRFs.

Development of a mouse model for pulp-dentin complex regeneration research: a preliminary study

  • Kim, Sunil;Lee, Sukjoon;Jung, Han-Sung;Kim, Sun-Young;Kim, Euiseong
    • Restorative Dentistry and Endodontics
    • /
    • 제44권2호
    • /
    • pp.20.1-20.8
    • /
    • 2019
  • Objectives: To achieve pulp-dentin complex regeneration with tissue engineering, treatment efficacies and safeties should be evaluated using in vivo orthotopic transplantation in a sufficient number of animals. Mice have been a species of choice in which to study stem cell biology in mammals. However, most pulp-dentin complex regeneration studies have used large animals because the mouse tooth is too small. The purpose of this study was to demonstrate the utility of the mouse tooth as a transplantation model for pulp-dentin complex regeneration research. Materials and Methods: Experiments were performed using 7-week-old male Institute of Cancer Research (ICR) mice; a total of 35 mice had their pulp exposed, and 5 mice each were sacrificed at 1, 2, 4, 7, 9, 12 and 14 days after pulp exposure. After decalcification in 5% ethylenediaminetetraacetic acid, the samples were embedded and cut with a microtome and then stained with hematoxylin and eosin. Slides were observed under a high-magnification light microscope. Results: Until 1 week postoperatively, the tissue below the pulp chamber orifice appeared normal. The remaining coronal portion of the pulp tissue was inflammatory and necrotic. After 1 week postoperatively, inflammation and necrosis were apparent in the root canals inferior to the orifices. The specimens obtained after experimental day 14 showed necrosis of all tissue in the root canals. Conclusions: This study could provide opportunities for researchers performing in vivo orthotopic transplantation experiments with mice.

즉발감마선을 이용한 양성자 빔 위치 측정에 관한 연구 (Determination of Proton Beam Position Based on Prompt Gamma Ray Detection)

  • 서규석;김종원;김찬형
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.69-71
    • /
    • 2004
  • 양성자 치료는 양성자 빔의 선량분포 특성인 브래그 피크를 이용한 방사선 치료방법으로 기존의 전자 및 광자빔을 이용하는 방사선 치료와 비교하여 정상세포에는 현저히 적은 선량을 주고, 암세포에는 대부분의 선량을 줄 수 있어 최근에 각광받고 있다. 양성자 치료 빔은 치료 부위에서 완전히 멈추고 인체 내 각기 다른 밀도를 가진 장기들에 의해 양성자 빔의 비정이 불확실하기 때문에 체내 양성자 빔의 분포를 확인하고 빔을 조정하면서 치료할 수 있는 적절한 방법이 없다. 양성자 빔의 물질에 대한 흡수선량 분포와 물질과 양성자의 핵반응으로 방출되는 즉발 감마선의 상관관계를 이용한 측정시스템을 몬테칼로 전산코드로 전산모사하고 계산한 결과 체내 양성자 빔의 위치를 실시간으로 측정할 수 있음을 확인하였다.

  • PDF

Array of Slot-Sleeve Antennas for Hyperthermia Therapy

  • Park Soo-Man;Lim Yeongseog
    • Journal of electromagnetic engineering and science
    • /
    • 제5권3호
    • /
    • pp.126-131
    • /
    • 2005
  • To increase the efficiency of an applicator during microwave hyperthermia therapy, first, the length from the antenna end to a slot is varied to get the optimal matching of the characteristic impedance at the frequency of 2.45 GHz. Using the electric and thermal constants of biological tissue, we compose a phantom to calculate temperature increment as well as the resonance characteristics and the SAR distributions. The proposed 3-slot sleeve antenna inserted in an applicator plays an effective role in increasing the therapy size in the view of heating performance as electromagnetic energy tends to concentrate on not feed point direction but treatment area. The SAR is then used in combination with a finite difference heat transfer equation to determine the temperature distribution. Also, in order to shorten treatment time and increase therapy size, a square-array structure is suggested and analyzed.

Numerical Investigation of Hemodynamics in a Bileaflet Mechanical Heart Valve using an Implicit FSI Based on the ALE Approach

  • Hong, Tae-Hyub;Choi, Choeng-Ryul;Kim, Chang-Nyung
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2410-2414
    • /
    • 2008
  • Human heart valves diseased by congenital heart defects, rheumatic fever, bacterial infection, cancer may cause stenosis or insufficiency in the valves. Treatment may be with medication but often involves valve repair or replacement (insertion of an artificial heart valve). Bileaflet mechanical heart valves (BMHVs) are widely implanted to replace the diseased heart valves, but still suffer from complications such as hemolysis, platelet activation, tissue overgrowth and device failure. These complications are closely related to both flow characteristics through the valves and leaflet dynamics. In this study, the physiological flow interacting with the moving leaflets in a bileaflet mechanical heart valve (BMHV) is simulated with a strongly coupled implicit fluid-structure interaction (FSI) method which is newly organized based on the Arbitrary-Lagrangian-Eulerian (ALE) approach and the dynamic mesh method (remeshing) in FLUENT. The simulated results are in good agreement with previous experimental studies. This study shows the applicability of the present FSI model to the complicated physics interacting between fluid flow and moving boundary.

  • PDF

Expression of β-arrestin 1 in Gastric Cardiac Adenocarcinoma and its Relation with Progression

  • Wang, Li-Guang;Su, Ben-Hua;Du, Jia-Jun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권11호
    • /
    • pp.5671-5675
    • /
    • 2012
  • Objective: Arrestins act as mediators of G protein-coupled receptor (GPCR) desensitization and trafficking, also actin as a scaffold for many intracellular signaling network. The role that ${\beta}$-arrestin 1 plays in gastric cardiac adenocarcinoma (GCA) and its clinicopathologic significance are untouched. Methods: Fifty patients with gastric cardiac adenocarcinoma were retrospectively enrolled and ${\beta}$-arrestin 1 was detected using immunohistochemistry in tissue samples. Results: Nuclear expression of ${\beta}$-arrestin 1 was observed in 78% of GCA samples (39/50) and cytoplasmic expression in 70% (35/50). ${\beta}$-arrestin 1 could be found in both nucleus and cytoplasm of 54% GCA (27/50) or in either of them in 94% (47/50). ${\beta}$-arrestin 1 protein positivity in well/moderately differentiated carcinomas was significantly higher than that in poorly differentiated carcinomas (P=0.005). We found increased expression of ${\beta}$-arrestin 1 in cytoplasm was correlated with lymph nodal metastasis (P=0.002) and pathological lymph nodal staging (P=0.030). We also found ${\beta}$-arrestin 1 to be over-expressed in glandular epithelia cells of mucinous adenocarcinoma, a tumour type associated with an adverse outcome of gastric cardiac adenocarcinoma (P=0.022). Conclusion: ${\beta}$-arrestin 1 is over-expressed in the nucleus and/or cytoplasm of gastric cardiac adenocarcinoma. However, ${\beta}$-arrestin 1 has no relationship with the prognosis of gastric cardiac adenocarcinoma (P>0.05). Our data imply that ${\beta}$-arrestin 1 in cytoplasm may be involved in differentiation and metastasis of gastric cardiac adenocarcinoma.