• Title/Summary/Keyword: camera exposure

Search Result 166, Processing Time 0.032 seconds

Estimation of Disparity Map having Reliability to Changes of Radiometric (Radiometric 특성 변화에 신뢰성을 가지는 Disparity Map 예측)

  • Shin, Kwang-mu;Kim, Sung-min;Cho, Mi-sook;Chung, Ki-dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.93-96
    • /
    • 2015
  • The aim of the estimation of disparity map is to find the corresponding pixels from similar two or more images. However, it is a difficult problem to get precise and consistent disparity under a variety of real world situations. In other words, the color values of stereo images are easily influenced by radiometric properties such as illumination direction, illumination color, and camera exposure. Therefore, conventional stereo matching methods can have low performances under radiometric conditions. In this paper, we propose an approaching of disparity map estimation that is reliable in controlling various radiometric variations close to the real environment. This method is motivated by following constancy. Even though each other has different radiometric property in stereo images, intensity of pixels of object have general constancy in specific block. Experimental results show that the proposed method has better performances compared to the comparison group under different radiometric conditions between stereo images. Consequentially, the proposed method is able to estimate the disparity map in stable under various radiometric variations.

  • PDF

A STUDY ON THE ASTRONOMICAL OBSERVATIONAL ENVIRONMENTS AT THE CHOEJUNG-SAN GEODSS SITE: I. SEEING AND NIGHT SKY BRIGHTNESS MEASUREMENTS AND UTILIZING PLAN FOR THE GEODSS SITE (최정산 위성추적소의 천체관측 환경에 관한 조사 연구: I. SEEING 및 야천광 관측과 위성추적소의 활용 방안)

  • Kang, Yong-Hui;Yun, Tae-Seok;Park, Byeong-Gon;Lee, Gi-Won;Choi, Yeong-Jun;Choi, Eun-Woo
    • Publications of The Korean Astronomical Society
    • /
    • v.11 no.1
    • /
    • pp.177-196
    • /
    • 1996
  • We have investigated the astronomical observational environments at the Choejung-san GEODSS site which is located at the south of Taegu, Korea. As a part of the investigation, seeing and night sky brightness were measured outside nearby the GEODSS site using the Celestron 8-inch portable reflector with $192{\times}165$ pixels Lynxx CCD camera during the period of December 1994 to April 1996. The average seeing values of 4.8 arcsecond in B filter and 5.1 arcsecond in V filter were determined using the IRAF software. These values might be overestimated and would be reduced by at least 1 arc second in both filters if they were measured by more stable telescope system with solid mount and under a dome. We also compare the average seeing value at the GEODSS site with those at three other observatories, the Bohyunsan Optical Astronomy Observatory, the Sobaeksan Optical Astronomy Observatory, and the Seoul National University Observatory, for justification of the above guess. Unfortunately the night sky brightness measurement was not successful mainly due to the short exposure time. The utilizing plan of the GEOSS site is discussed based on the average seeing value, naked-eye sky brightness measurement, analysis of the existing thirty-year weather data and twenty-year urban planning of the metropolitan Taegu city for the year of 2016.

  • PDF

Block Adjustment with GPS/INS in Aerial Photogrammetry (GPS/INS에 의한 항공사진측량의 블럭조정)

  • Park Woon Yong;Lee Kang Won;Lee Jae One;Jeong Gong Uhn
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.22 no.3
    • /
    • pp.285-291
    • /
    • 2004
  • GPS photogrammetry or the GPS/INS photogrammetry, which are based on the direct measurement of the projection centers and attitude at the moment of camera exposure time through loading the GPS receiver or INS in aircraft. Both photogrammetric methods can offer us to acquire the exterior orientation parameters with only minimum ground control points, even the ground control process could be completely skipped. Consequently, we can drastically reduce the time and cost for the mapping process. In this thesis, test flight was conducted in Suwon area to evaluate the performance of accuracy and efficiency through the analysis of results among the three photogrammetric methods, that is, traditional photogrammetry, GPS photogrammetry and GPS/INS photogrammetry. Test results shows that a large variety of advantages of GPS photogrammetry and GPS/INS photogrammetry against traditional photogrammetry is to be verified. Especially, the number of ground control points for the exterior orientation could be saved more than 70~80%, respectively.

A Study on the Explosion to Fire Transition Phenomena of Liquidfied Petroleum Gas (LP가스 폭발로부터 화재로의 천이에 관한 연구)

  • 오규형;이춘하
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.4
    • /
    • pp.107-113
    • /
    • 1993
  • Small rectangular explosion chamber of its size 25cmX25cmX32cm with a circular bursting diaphram at the top was used to study the mechanism of gas explosion to fire transition phenomena, the process of ignition of solid combustibles during a gas explosion. To visulize the explosion to fire transition phenomena, transparent acryl window and high speed camera system were used. The test piece of solid combustible in this experiments was a 5cm$\times$5cm square sheet of newspaper which was placed in the explosion chamber filled with a LPG-air mixture. The mixture was ignited by an electric spark at the center of the chamber. Explosion to fire transition phenomena and the behavior of out flow and in flow of gas through the opening yielded by bursting the diaphram was visualized with shlieren system and without shlieren system. Diameter of a bursting dlaphram at the top of the explosion chamber was varied 5cm, 10cm, and 15cm, and the position of test piece were varied with 6 point. Explosion pressure was measured with strain type pressure transducer, and the weight difference of the test piece before and after each experimental run was measured. By comparing the weight difference of solid combustibles before and after the experiment and the behavior of out flow and inflow of gas after explosion, it was found that the possibility of ignition was depends on the LPG-air mixture concentration and the exposure period of test piece to the burnt gas. Test result of this experiments it was found that the main factor of this phenomena are that heat transfer to the test piece, and the pyrolysis reaction of test piece. Based on the results, the mechanism of the explosion to fire transition phenomena were inferred ; gas explosion- heat transfer to solid combustibiles ; pyrolysis reaction of solid combutibles : air inflow ; mixing of the pyroly gas with air ignition.

  • PDF

Use of $^{99m}TcO_4^-$ Salivary-Thyroid Ratio As a Test of Thyroid Function (갑상선스캔상에서 갑상선섭취율의 추정방법 : 타액선-갑상선계수율)

  • Yang, Woo-Jin;Chung, Soo-Kyo;Chun, Ki-Sung;Kim, Jong-Woo;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.151-154
    • /
    • 1987
  • Total 114 patients were studied prospectively with radioiodine uptake (RAIU) and $^{99m}TcO_4^-$ thyroid scan to design a very simple, rapid and inexpensive method measuring the thyroid uptake on thyroid scan. After the RAIU was obtained at 24 hours after P.O. of $^{131}I$, Thyroid scan was performed at 20 minutes after LV. of $^{99m}TcO_4^-$ and the bilateral salivary glands were included in the scan field. Pinhole collimated and computer assisted gamma camera was used. Three regions of interest were set on each salivary gland and on the thyroid by automatic edge detection method. Mean counts per pixel were calculated for each ROI and the salivary-thyroid ratio (STR) was defined as; $$STR(%)=\frac{Mean\;counts\;per\;pixel\;of\;salivary\;glands\;(KC)}{Mean\;counts\;per\;pixel\;of\;thyroid\;gland\;(KC)}\times100$$ 114 cases consisted of 41 normal, 55 hyperthyroid and 18 hypothyroid patients and correlation between the STR and the RAID were evaluated in total and each group. The STR and the RAID showed reverse linear regression in 114 cases (r= -0.8, P=0) and closer correlation was shown in hyperthyroid group (r= -0_9, p=0). Mean STR in normal group was 47.6%. In predicting the RAID by STR, sensitivity and specificity were 88.3% and 64.9% in 114 cases and 95.3% and 83.3% in hyperthyroid group. It is recommended that the STR be used in place of the RAID giving same information at saving time, money and radiation exposure.

  • PDF

Enhancement of bloodstain on the dark or multi-colored surfaces by using the acidic hydrogen peroxide (Acidic hydrogen peroxide를 이용한 어둡거나 다양한 색상의 표면에 부착된 혈흔의 증강)

  • Sungwook Hong;Wonyoung Lee;Jaeyoung Byeon;Hyunju Shin;Jaeuk Ha
    • Analytical Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.121-127
    • /
    • 2023
  • The detection of blood at a crime scene is an important process for identification and case reconstruction. However, blood may be difficult to observe with the naked eye on dark or multi-colored surfaces. Acidic hydrogen peroxide (AHP) is a recently reported blood enhancement reagent that can enhance blood with high sensitivity by increasing the exposure time of the camera. However, it has never been compared to previously known techniques on dark or multi-colored surfaces. For this purpose, the method of observation/photographing (UV and IR photography), alginate casting, leuco rhodamine 6G (LR6G), and AHP were applied to bloody impression on dark or multi-colored surfaces and the results were compared. As a result, blood treated with AHP had a higher contrast to the surfaces than UV and IR photography, and it was applicable on all surfaces, opposed to alginate casting. In addition, AHP successfully enhanced blood on dark or multi-colored surfaces, similar to LR6G.

Visible Height Based Occlusion Area Detection in True Orthophoto Generation (엄밀 정사영상 제작을 위한 가시고도 기반의 폐색영역 탐지)

  • Youn, Junhee;Kim, Gi Hong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3D
    • /
    • pp.417-422
    • /
    • 2008
  • With standard orthorectification algorithms, one can produce unacceptable structure duplication in the orthophoto due to the double projection. Because of the abrupt height differences, such structure duplication is a frequently occurred phenomenon in the dense urban area which includes multi-history buildings. Therefore, occlusion area detection especially for the urban area is a critical issue in generation of true orthophoto. This paper deals with occlusion area detection with visible height based approach from aerial imagery and LiDAR. In order to accomplish this, a grid format DSM is produced from the point clouds of LiDAR. Next, visible height based algorithm is proposed to detect the occlusion area for each camera exposure station with DSM. Finally, generation of true orthophoto is presented with DSM and previously produced occlusion maps. The proposed algorithms are applied in the Purdue campus, Indiana, USA.

Lightweight Attention-Guided Network with Frequency Domain Reconstruction for High Dynamic Range Image Fusion

  • Park, Jae Hyun;Lee, Keuntek;Cho, Nam Ik
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2022.06a
    • /
    • pp.205-208
    • /
    • 2022
  • Multi-exposure high dynamic range (HDR) image reconstruction, the task of reconstructing an HDR image from multiple low dynamic range (LDR) images in a dynamic scene, often produces ghosting artifacts caused by camera motion and moving objects and also cannot deal with washed-out regions due to over or under-exposures. While there has been many deep-learning-based methods with motion estimation to alleviate these problems, they still have limitations for severely moving scenes. They also require large parameter counts, especially in the case of state-of-the-art methods that employ attention modules. To address these issues, we propose a frequency domain approach based on the idea that the transform domain coefficients inherently involve the global information from whole image pixels to cope with large motions. Specifically we adopt Residual Fast Fourier Transform (RFFT) blocks, which allows for global interactions of pixels. Moreover, we also employ Depthwise Overparametrized convolution (DO-conv) blocks, a convolution in which each input channel is convolved with its own 2D kernel, for faster convergence and performance gains. We call this LFFNet (Lightweight Frequency Fusion Network), and experiments on the benchmarks show reduced ghosting artifacts and improved performance up to 0.6dB tonemapped PSNR compared to recent state-of-the-art methods. Our architecture also requires fewer parameters and converges faster in training.

  • PDF

Evaluation of the combination of Bone Scan Image and Pelvic X-ray Image (뼈 검사 영상과 골반 X선 영상의 결합 유용성 평가)

  • Lee, Choong Woon;You, Yeon Wook;Kim, Yong Keun;Weon, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.23-27
    • /
    • 2018
  • Purpose The introduction of bone scan has been reported as a useful tool in the diagnosis, treatment, and treatment response of skeletal disease. The purpose of this study is to improve the anatomical information and tolerance of the bone by combining bone scan and pelvic X-ray without additional radiation exposure. Materials and Methods From November 2015 to August 2016, 236 patients(64 men and 172 women, average age $50.96{\pm}15.39years$) take Bone scan and Pelvis AP(Anteroposterior) X-ray scan at the National Cancer Center. The scan equipment was a gamma camera, Symbia Ecam (SIEMENS, Germany), and a digital x-ray, DRS-800 (Listem, Korea). Osirix version 3.8.1 (Osirix, USA) and Stata/SE version 14.0 (StataCorp, USA) were used for image combination and analysis. The patient was intravenously injected with $^{99m}Tc-DPD$ (740 MBq), and the scan was performed 2 to 4 hours later. Gamma camera image acquisition were Matrix size $256{\times}1024$, Zoom 1.00, and scan speed 17 cm/min. The digital X-ray was made with a collimator size of $14^{{\prime}{\prime}}{\times}17^{{\prime}{\prime}}$, 77 kVp (60 to 97 kVp) and an average of 30 mAs (20 to 48). ASIS and pubic symphysis Select virtual points then Combine three virtual points and pelvic contour lines. The acquired images were evaluated by three radiologists who worked for more than 5 years in the nuclear medicine department. Results Of the total 236 patients, 216 (91.53%) were matched. The median and range (min~max) of the age were 67 (46~81) years old in the unmatched group and 52 (22~87) years old in the matched group, The Wilcoxon rank-sum test was performed to determine whether age was different between the two groups. As a result, the age difference between the two groups was statistically significant at p < 0.0001. Of the 64 men, 60 (93.75%) were match and of the 172 women, 156 (93.75%) were match. There was no statistically significant difference according to gender(p = 0.4542). Of the 54 patients without pelvic lesions, 54 (100.00%) were match, and 162 (89.01%) of 182 patients with pelvic lesions were match. There was a statistically significant difference according to the presence of pelvic lesions. Conclusion There are many variables in the combination of bone scan and pelvic X-ray imaging, and the patient's age and pelvic lesion may have some effect on the image combination. This study is expected to be useful for the diagnosis of pelvic osteosarcoma of children without radiation exposure. It is expected that this combination of images will help to develop the nuclear medicine image.

Evaluation on Reproducibility of Low-Dose Kidney Scan in Dynamic Kidney Scan (동적신장검사에서 저선량을 사용한 신장검사의 재현성 평가)

  • Lee, Jaesang;Lee, Kyuchan;Lee, Seunghwan;Bae, Seongbok;Park, Jongyeop
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.59-65
    • /
    • 2016
  • Purpose Dynamic kidney scan is a typical imaging technique that visualizes kidney function. Reproducibility of dynamic kidney scans has been evaluated by comparing low-dose kidney scans with low-dose radiopharmaceutical and standard dynamic kidney scan. With this comparative study, if reproducibility is superb, the dynamic kidney scan method with reduced radioactivity to patients is to be utilized and radiation exposure to patient is to be reduced. Materials and Methods For gamma camera, Orbiter, SymbiaE (Siemens, Germany) was used. Among patients who had used 370 Mbq (10 mCi) from January of 2013 to February 2014 and other patients who had used 185 Mbq (5 mCi) from March of 2014 to July of 2015 with identical condition, 21 subjects using DTPA and 20 subjects using $MAG_3$, 41 subjects in total, had been selected as subjects for data. From renogram of the result image, frame of the peak point was selected. Then, region of interest of kidney and background had been selected and Kidney to Background Ratio has been calculated for comparison. Results In tests using DTPA, kidney to background ratio when using 370 Mbq was $5.67{\pm}0.8$ at average while it was $5.62{\pm}0.87$ when using 185 Mbq, which didn't show much difference. Also in the tests using $MAG_3$, kidney to background ratio when using 370 Mbq was $14.95{\pm}2.58$ at average and $14.56{\pm}2.02$ in 185 Mbq, which neither showed much difference. In paired sample t-test, p-value was 0.566 in DTPA and 0.363 in $MAG_3$, which confirmed that there was no difference between the groups. Conclusion In identical patients, when dose was decreased from 370 Mbq to 185 Mbq, reproducibility of dynamic kidney scan was proven to be excellent. Low-dose Dynamic kidney scan can achieve results with fine reproducibility without improvement in performance of gamma camera and is expected to reduce radiation exposure to patient.

  • PDF