• Title/Summary/Keyword: camera calibration

Search Result 693, Processing Time 0.028 seconds

A Flexible Camera Calibration System for Mobile Platform

  • Lu, Bo;Whangbo, Taeg-Keun;Han, Tae-Kyu
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2013.11a
    • /
    • pp.1457-1460
    • /
    • 2013
  • We propose a flexible camera calibration system for mobile platform to calibrate the camera's intrinsic parameters which based on the geometrical property of the vanishing points determined by two perpendicular groups of parallel lines. The system only requires the camera to observe a rectangle card show at a few(at least four)different orientation. The experimental results of the real images show the proposed calibration system in this paper is easy to use and robust.

Accurate Camera Calibration Using GMDH Algorithm (GMDH 알고리즘을 이용한 정확한 카메라의 보정기법)

  • Kim, Myoung-Hwan;Do, Yong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.592-594
    • /
    • 2004
  • Camera calibration is an important problem to determine the relationship between 3D real world and 2D camera image. The existing calibration methods can be classified into linear and non-linear models. The linear methods are simple and robust against noise, but the accuracy expectation is generally poor. In comparison, if the non-linearity, which is due mainly to lens distortion, is corrected, the accuracy can be better. However, as the optical features of lens are diverse, no non-linear method can be always effective for diverse vision systems. In this paper, we propose a new approach to correct the calibration error of a linear method using GMDH algorithm. The proposed technique is simple in concept and showed improved accuracy in various cases.

  • PDF

The calibration of a laser profiling system for seafloor micro-topography measurements

  • Loeffler, Kathryn R.;Chotiros, Nicholas P.
    • Ocean Systems Engineering
    • /
    • v.1 no.3
    • /
    • pp.195-205
    • /
    • 2011
  • A method for calibrating a laser profiling system for seafloor micro-topography measurements is described. The system consists of a digital camera and an arrangement of six red lasers that are mounted as a unit on a remotely operated vehicle (ROV). The lasers project as parallel planes onto the seafloor, creating profiles of the local topography that are interpreted from the digital camera image. The goal of the calibration was to determine the plane equations for the six lasers relative to the camera. This was accomplished in two stages. First, distortions in the digital image were corrected using an interpolation method based on a virtual pinhole camera model. Then, the laser planes were determined according to their intersections with a calibration target. The position and orientation of the target were obtained by a registration process. The selection of the target shape and size was found to be critical to a successful calibration at sea, due to the limitations in the manoeuvrability of the ROV.

Estimation of the position and orientation of the mobile robot using camera calibration (카메라 캘리브레이션을 이용한 이동로봇의 위치 및 자세 추정)

  • 정기주;최명환;이범희;고명삼
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.786-791
    • /
    • 1992
  • When a mobile robot moves from one place to another, position error occurs due to the limit of accuracy of robot and the effect of environmental noise. In this paper. an accurate method of estimating the position and orientation of a mobile robot using the camera calibration is proposed. Kalman filter is used as the estimation algorithm. The uncertainty in the position of camera with repect to robot base frame is considered well as the position error of the robot. Besides developing the mathematical model for mobile robot calibration system, the effect of relative position between camera and calibration points is analyzed and the method to select the most accurate calibration points is also presented.

  • PDF

Radiometric Calibration Method with Compensation of Nonlinearity of Detector for Hyper-Spectral Camera

  • Yang, Ji-Hyeon;Choi, Byung-In;Park, Hee Duk;Kim, Sohyun;Park, Yong Chan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.10
    • /
    • pp.27-34
    • /
    • 2017
  • In this paper, we propose a novel radiometric calibration method which can effectively compensate the nonlinearity of the detector for hyper-spectral camera. In general, the detector of hyper-spectral camera can produce nonlinear output depending on radiance and integral time. The conventional radiometric calibration methods extract the imprecise radiance profile from the spectral profile of the target due to this nonlinearity. In our proposed method, we use a quadratic equation instead of a linear equation to describe the relation between output of detector and radiance. Then, we use a fractional function to compensate variation of integration time. Thus, our proposed method can extract more precise spectral profile of radiance than conventional radiometric calibration method.

Multi-camera Calibration Method for Optical Motion Capture System (광학식 모션캡처를 위한 다중 카메라 보정 방법)

  • Shin, Ki-Young;Mun, Joung-H.
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.6
    • /
    • pp.41-49
    • /
    • 2009
  • In this paper, the multi-camera calibration algorithm for optical motion capture system is proposed. This algorithm performs 1st camera calibration using DLT(Direct linear transformation} method and 3-axis calibration frame with 7 optical markers. And 2nd calibration is performed by waving with a wand of known length(so called wand dance} throughout desired calibration volume. In the 1st camera calibration, it is obtained not only camera parameter but also radial lens distortion parameters. These parameters are used initial solution for optimization in the 2nd camera calibration. In the 2nd camera calibration, the optimization is performed. The objective function is to minimize the difference of distance between real markers and reconstructed markers. For verification of the proposed algorithm, re-projection errors are calculated and the distance among markers in the 3-axis frame and in the wand calculated. And then it compares the proposed algorithm with commercial motion capture system. In the 3D reconstruction error of 3-axis frame, average error presents 1.7042mm(commercial system) and 0.8765mm(proposed algorithm). Average error reduces to 51.4 percent in commercial system. In the distance between markers in the wand, the average error shows 1.8897mm in the commercial system and 2.0183mm in the proposed algorithm.

Camera Modeling and Calibration for Kinematic Calibration of a SCARA Robot (스카라 로봇의 자세 보정을 위한 카메라 모델링 및 캘리브레이션)

  • 왕한흥
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.65-69
    • /
    • 1997
  • This paper presents a new approach to the calibration of a SCARA robot orientation with a camera modeling that accounts for major sources of camera distortion, namely, radial, decentering, and thin prism distortion. Radial distortion causes an inward or outward displacement of a given image point from its ideal location. Actual optical systems are subject to various degrees of decentering, that is, the optical centers of lens elements are not strictly collinear. Thin prism distortion arises from imperfection in lens design and manufacturing as well as camera assembly. It is our purpose to develop the vision system for the pattern recognition and the automatic test of parts and to apply the line of manufacturing.

  • PDF

A Study on the Camera Calibration Algorithm using Perspective Ratio of Difference Line Widths

  • Jeong, Jun-Ik;Song, Suck-Woo;Lee, Ho-Soon;Rho, Do-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.63.1-63
    • /
    • 2001
  • At 3-D vision measuring, the camera calibration is necessary to calculate parameters accurately. Camera calibration was developed widely in two categories. One is that establishes reference points in space, and the other is that uses the grid type frame and statistical method. But, the former has difficult to setup reference points and the latter has low accuracy. In this paper we present an algorithm for camera calibration using perspective ratio of the grid type frame with different line widths. The advantage of this algorithm is that it can estimate position, pose and distance between camera and object ...

  • PDF

A New Hand-eye Calibration Technique to Compensate for the Lens Distortion Effect (렌즈왜곡효과를 보상하는 새로운 hand-eye 보정기법)

  • Chung, Hoi-Bum
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.1
    • /
    • pp.172-179
    • /
    • 2002
  • In a robot/vision system, the vision sensor, typically a CCD array sensor, is mounted on the robot hand. The problem of determining the relationship between the camera frame and the robot hand frame is refered to as the hand-eye calibration. In the literature, various methods have been suggested to calibrate camera and for sensor registration. Recently, one-step approach which combines camera calibration and sensor registration is suggested by Horaud & Dornaika. In this approach, camera extrinsic parameters are not need to be determined at all configurations of robot. In this paper, by modifying the camera model and including the lens distortion effect in the perspective transformation matrix, a new one-step approach is proposed in the hand-eye calibration.

A Study for the 3-Dimensional Measurement System using Laser Slit-Ray (레이저 슬릿광을 이용한 3차원 계측 장치에 관한 연구)

  • 김선일;정재문;양윤모
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.29B no.2
    • /
    • pp.27-39
    • /
    • 1992
  • 3 Dimensional measurement system using camera and laser slit-ray is studied. Precise calibration technique in this system is suggested. Calibration is accomplished with calibration die, calibration block and robot. For obtaining calibration parameters, the equations are solved using least square error method from a great many calibration points to reduce measuring error. Continuous measurement is possible for the object which is larger than one frame of camera. The efficiency and usability are proved by applying to the tire profile measuring system which measures tire profile using robot and this system.

  • PDF