Rotary compressor with combined vane and roller (베인-롤러 일체형 로타리 압축기)

  • Ahn, Jong-Min;Kim, Hyun-Jin;Kang, Seoung-Min
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.904-909
    • /
    • 2009
  • In this paper, a rolling piston rotary compressor having a combined vane and roller unit has been introduced. In a conventional rotary compressor, sliding motion takes place between the vane nose and roller. By combining the vane and the roller in one unit, gas leakage through a clearance between the vane nose and the roller can be eliminated, and the frictional loss between them can also be reduced to almost nought. Compressor model with the combined vane and roller has been fabricated and tested in a compressor calorimeter and computer simulation program has been developed to confirm merits of the new mechanism. In a test, cooling capacity has been found to be increased by 1.4%, and the compressor input decreased by 0.3%, resulting in 1.7% increased in EER. Simulation program confirmed the calorimeter test results and the merits of the new model as mentioned above.

  • PDF

Evaluation of Fire Characteristics for Particle-board with Exfoliated Graphite Nanoplatelets Added (탄소재료의 적용 방법에 따른 파티클 보드의 연소 특성)

  • Seo, Hyun Jeong;Jo, Jeong Min;Hwang, Wuk;Lee, Min Chul
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.4
    • /
    • pp.1-8
    • /
    • 2017
  • This study was conducted to evaluate the fire retardant performance of exfoliated graphite nanoplatelets (xGnP) applied for particleboard. This work measured heat release rate(HRR), total heat release(THR) and smoke production rate(SPR) of xGnP added particleboard, using cone calorimeter to assess its fire characteristics according to the KS F ISO 5660-1 standard code. Heat release rates of all specimens treated by xGnP were less than the $200kW/m^2$ for a total experiment period of five minutes. Heat release rates of the specimens coated with xGnP were lower than those of the specimens made by mixing wood particles with xGnP directly. Meanwhile, the total heat release rates of xGnP coated specimen maintained quite lower level than the uncoated so the xGnP coating were effective in improving the fire retardant performance of particleboard. However, the smoke emission peaking problem at the initial combustion period, which was caused by adding base coating materials, should be resolved for further satisfaction as a fire retardant materials.

Heat Flow Studies in Low Temperature Detectors (저온검출기의 열전도 연구)

  • Kim, Il-Hwan;Lee, Min-Kyu;Kim, Yong-Hamb
    • Progress in Superconductivity
    • /
    • v.12 no.1
    • /
    • pp.41-45
    • /
    • 2010
  • Low temperature micro-calorimeters have been employed in the field of high resolution alpha spectrometers. These alpha detectors typically consist of a superconducting or metal absorber and a temperature sensor. The temperature sensor can be a transition edge sensor (TES), a metallic magnetic calorimeter (MMC) or other low temperature detectors for an accurate measurement of temperature change due to an alpha particle absorption. We report a recent study of the heat flow between a replaceable absorber and a temperature sensor. A piece of gold foil in $2.4{\times}2.7{\times}0.03\;mm^3$ is used as an absorber. A $40\;{\mu}m$ diameter Au:Er paramagnetic sensor is attached to another small piece of gold foil in $400{\times}200{\times}30\;{\mu}m^3$ to serve as the temperature sensor. This sensor assembly, Au:Er and gold foil, is placed on a miniature SQUID susceptometer in a gradiometric configuration. The thermal connection between the absorber and the sensor was made with three gold bonding wires. The measured thermal conductance shows a linear dependence to the temperature. The values are in a good agreement with Wiedemann-Franz type thermal conductance of the gold wires.

Analysis on the Reaction-to-fire's Performance of Sandwich Panel Systems by using ISO 5660-1 and EN 13823 Fire Tests (중소형 화재시험(ISO 5660-1 및 EN 13823)을 이용한 샌드위치패널 연소성능 분석)

  • Park, Kye-Won;Im, Hong-Soon;Jeong, Jae-Gun;Kim, Woon-Hyung
    • Fire Science and Engineering
    • /
    • v.23 no.1
    • /
    • pp.33-39
    • /
    • 2009
  • In this study, the combustion properties, which are called the reaction-to-fire's performance, of sandwich panels were tested and analyzed according to both ISO 5660 (cone calorimeter method) and EN 13823 (SBI). Several variables including ignition time, mass loss, heat release rate, smoke production rate and $O_2$ density about four sandwich panels and four core materials (thermal insulation material) were evaluated. Combustion properties' similarity and difference of sandwich panels and core materials were compared by materials and test methods respectively. Finally test results were evaluated by Japanese standard building code, National Building code of Canada and EN 13501-1 as well.

Construction of AC calorimeter and measurement of thermal diffusivity of glass substrate coated by ZnS optical thin films (교류열량계 제작 및 ZnS 광학박막이 증착된 유리기판의 열확산도 측정)

  • 김석원;김형근;박병록;한성홍;성대진
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.174-180
    • /
    • 1996
  • For the investigation of the influence of microstructure of optical thin films on the in-plane thermal diffusivity of glass substrate coated by that films, we constructed the AC calorimeter which uses argon-ion laser as a thermal source and measured several kinds of ZnS optical thin films which prepared by the changing of thermal evaporation speed such as 5$\AA$/s, 10$\AA$/s, 20$\AA$/s, 40$\AA$/s, 60$\AA$/s. The result showed that the thermal diffusivity decreases as the temperature increases. Also, when the evaporation speed is 20$\AA$/s, the thermal diffusivity has maximum value, and the variation of the thermal diffusivities are 27% at maximum.

  • PDF

An Analytic and Experimental Study on the Performance Characteristic of the Rotary Compressor (로타리 압축기 성능특성에 관한 해석 및 실험)

  • 최득관;김경천;차강욱
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.497-504
    • /
    • 2001
  • A study to improve the accuracy of a map-based compressor model with experiment was performed. Corrections on the effects of suction gas superheat and heat leakage from a compressor shell are required to apply the compressor amp model based on the empirical performance data(map) of compressor manufacturers to the actual system. So experiments to assess the effects of superheat and hat leakage were performed and the corrected equations were made. Compressors and refrigerant used in the experiment were the high pressure type rotary compressor and R-22, experiments were performed by compressor calorimeter. From the experiment, a volumetric efficiency correction factor$(F_ν)$ showed the value of 0.77, slightly higher than 0.75 proposed by Dabiri and Rice for low pressure type reciprocating compressor, and the heat leakage from the compressor shell turned out to be a factor that influenced the discharged mass flow rate. The relation between heat leakage of compressor shell and the variation of discharged mass flow rate from compressor was considered in compressor map modeling as an empirical function. With this function, the prediction accuracy of compressor model in system conditions was improved.

  • PDF

Gas Pulsation Analysis in a T-Shaped Suction Passage of a CO2 Twin Rotary Compressor (CO2 트윈 로타리 압축기의 흡입관로에서의 가스맥동 해석)

  • Kim, Woo-Young;Ahn, Jong-Min;Kim, Hyun-Jin;Cho, Sung-Oug
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.8
    • /
    • pp.549-555
    • /
    • 2011
  • For a $CO_2$ one-stage twin rotary compressor, a T-shaped suction port was used to effectively supply the suction gas stream into two individual suction chambers of the twin cylinders. Suction gas pulsations were observed in the pressure sensor signals and these were simulated by using the acoustic modeling of Helmholz resonators in parallel. The module of acoustic modeling was combined to a computer simulation program for the compressor performance. Validation of the simulation program has been carried out for a bench model compressor in a compressor calorimeter. Cooling capacity and the compressor input power were reasonably well compared between the simulation and the calorimeter test. Particularly, good agreement on P-V diagram between the simulation and the test was obtained.

HTPB Propellant Ageing Property and HFC Base Shelf-Life Evaluation Method (HTPB 추진제 노화 특성 및 HFC 기반 수명 평가 기법)

  • Cho, Wonho;Westerlund, M.;Ryoo, Baek-Neung;Jung, Gyoo-Dong;Yoo, Ji-Chang
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.148-153
    • /
    • 2017
  • During natural ageing of HTPB propellant undergoes a series of slow physico-chemical degradation reactions. By using accelerated ageing conditions it is possible to simulate the material behaviour at different time-temperature conditions especially focused on the in-service conditions. Ageing behaviour of HTPB propellant were investigated using HFC(Micro-Heat Flow Calorimeter) is universal technique for measuring the rate of slow chemical and physical processes in long-term storage.

  • PDF

An Experimental Stuff on the Performance of Multi-type Heat Pump using Capillary Tubes (모세관을 이용한 멀티형 열펌프의 신뢰성에 관한 실험적 연구)

  • 권영철;장근선;이윤수;김대훈;전용호;이상재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.9
    • /
    • pp.749-755
    • /
    • 2002
  • In order to develop a multi-type heat pump system with two indoor units of non-uniform capacities, the optimum refrigerant circuit was developed using capillary tubes. The refrigerant circuit was composed of four main parts, a heating circuit, a cooling circuit, a by-pass circuit and a balance circuit. The system characteristics of multi-type heat pump was investigated through the rating test and the reliability test, using the multi-type psy-chrometric calorimeter. The results of the rating test showed that the capacity of the multi-type heat pump was about 93% of the design value. In particular, the capacity of cooling single mode was about 13% higher than the design value, and the capacity of heating multi mode was about 5% higher than the design value. The reliability of the multi-type heat pump was verified by various reliability tests (overload, extension tube, freeze up, under/over charging, sweat, flood back). The optimal amount of refrigerant charge and compressor capacity were determined from the present work.

An Evaluation of Thermal Stability on Esterification Process in Manufacture of Concrete Mixture Agents (시멘트 혼화제 제조시 에스테르화공정의 열 안정성 평가)

  • Lee, Keun-Won;Lee, Jung-Suk;Choi, Yi-Rae;Han, In-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.4
    • /
    • pp.40-46
    • /
    • 2009
  • The early identification of thermal hazards associated with a process such as the heats of reaction, exothermic decompositions, and the understanding of thermodynamics before any large scale operations are undertaken. The evaluation of reaction factors and thermal behavior on esterification process in manufacture of concrete mixture agents are described in the present paper. The experiments were performed in the differential scanning calorimetry(DSC), C 80 calorimeter, and thermal screening unit($TS^u$). The aim of the study was to evaluate the thermal stability of single material and mixture in esterification process. We provided the thermal data of chemical materials to present safe operating conditions through this study.