• Title/Summary/Keyword: calibration period

Search Result 270, Processing Time 0.026 seconds

Structural monitoring of a wind turbine steel tower - Part I: system description and calibration

  • Rebelo, C.;Veljkovic, M.;da Silva, L. Simoes;Simoes, R.;Henriques, J.
    • Wind and Structures
    • /
    • v.15 no.4
    • /
    • pp.285-299
    • /
    • 2012
  • This paper describes the development and calibration of a structural monitoring system installed in a 80 meters high steel wind tower supporting a 2.1 MW turbine Wind Class III IEC2a erected in the central part of Portugal. The several signals are measured at four different levels and include accelerations, strains on the tower wall and inside the connection bolts, inclinations and temperature. In order to correlate measurements with the wind velocity and direction and with the turbine operational parameters the corresponding signals are obtained directly from the turbine own monitoring system and are incorporated in the developed system. Results from the system calibration, the structural identification and the initial period of data acquisition are presented in this paper.

Calibration of flush air data sensing systems for a satellite launch vehicle

  • Mehta, R.C.
    • Advances in aircraft and spacecraft science
    • /
    • v.9 no.1
    • /
    • pp.1-15
    • /
    • 2022
  • This paper presents calibration of flush air data sensing systems during ascent period of a satellite launch vehicle. Aerodynamic results are numerically computed by solving three-dimensional time dependent compressible Euler equations over a payload shroud of a satellite launch vehicle. The flush air data system consists of four pressure ports flushed on a blunt-cone section of the payload shroud and connected to on board differential pressure transducers. The inverse algorithm uses calibration charts which are based on computed and measured data. A controlled random search method coupled with neural network technique is employed to estimate pitch and yaw angles from measured transient differential pressure history. The algorithm predicts the flow direction stepwise with the function of flight Mach numbers and can be termed as an online method. Flow direction of the launch vehicle is compared with the reconstructed trajectory data. The estimated values of the flow direction are in good agreement with them.

Using SWAT Model for streamflow simulation in Burundi

  • Habimana, Jean de Dieu;Ha, Doan Thi Thu;Bae, Deg-Hyo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.117-117
    • /
    • 2020
  • The main objective of this study was to setup model and evaluate the model performance for streamflow simulation in Burundi using Soil and Water Assessment Tool (SWAT) model. The total area of Burundi is 27,834 ㎢. The elevation of Burundi ranges from 780 m to 2,700m. The West and East are low lands, while the Central part is high land. The topographic data (30 meters Digital Elevation Model) and land use and land cover data of Burundi were obtained respectively from Shuttle Radar Topography Mission (SRTM) and the Regional Centre for Mapping of Resources for Development (RCMRD). The soil data used was obtained from Food and Agriculture Organization (FAO). The local weather data and discharge data were provided by Burundi Hydro meteorological Service (IGEBU). Mean Areal Precipitation (MAP) and Mean Areal Temperature (MAT) were estimated. The streamflow simulation was done for the period 1980-2017. The calibration and validation of river discharge was performed at a daily time step from 2005 through 2011 as the calibration period and 2012 up to 2017 as the validation period. The findings show that streamflow decreases during Jun to September and increases during March to May and October to December.

  • PDF

Calibration of Hydrologic Parameters of HSPF Using HSPEXP Model Performance Criteria (HSPEXP 모형평가지표를 이용한 HSPF 모형의 수문매개변수 보정)

  • Kim, Sang-Min;Seong, Choung-Hyun;Park, Seung-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.116-119
    • /
    • 2009
  • HSPF is a comprehensive, continuous, lumped parameter, watershed-scale model that simulates the movement of water, sediment, and a wide range of water quality constituents on pervious and impervious surfaces, in soil profiles, and within streams and well-mixed reservoirs. The hydrologic calibration of HSPF is performed manually using the decision-support software Expert System for the Calibration of HSPF (HSPEXP). The initial values for the HSPF hydrologic parameters were estimated based on guidance from BASINS Technical Note 6. Initial parameter values were adjusted for the study watershed during the calibration period within the recommended ranges for the parameters.

  • PDF

Effects of Long-term Exposure of High and Low Humidity on Thin-film Humidity Sensors

  • Lee, Sang-Wook;Choi, Byung Il;Kim, Jong Chul;Woo, Sang-Bong
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.368-373
    • /
    • 2018
  • The effects of long-term exposure of high and low humidity on thin-film humidity sensors are investigated. Five commercially available thin-film humidity sensors are initially calibrated in a humidity chamber as a reference before longterm exposure to high and low humidity. Then, the sensors are kept in a high-humidity environment (~95 %rh) for four months. After the exposure, the sensors are calibrated in the same manner as the initial calibration. Consequently, the device reading values from the humidity sensors are elevated up to about 5 %rh. Interestingly, the degree of elevation by the high-humidity exposure shows a negative correlation with the price of the humidity sensors. Humidity sensors are then kept in a low-humidity environment (~10 %rh) for another four months. After the exposure, a calibration similar to the initial calibration is performed. As a result, the device reading from humidity sensors is decreased, indicating a recovery from the effect of high-humidity exposure. The durability test conducted in this study provides experimental evidence for the use of thin-film humidity sensors in high-humidity environments such as greenhouses and food factories for a long period of time.

Calibration of Portable Particulate Mattere-Monitoring Device using Web Query and Machine Learning

  • Loh, Byoung Gook;Choi, Gi Heung
    • Safety and Health at Work
    • /
    • v.10 no.4
    • /
    • pp.452-460
    • /
    • 2019
  • Background: Monitoring and control of PM2.5 are being recognized as key to address health issues attributed to PM2.5. Availability of low-cost PM2.5 sensors made it possible to introduce a number of portable PM2.5 monitors based on light scattering to the consumer market at an affordable price. Accuracy of light scatteringe-based PM2.5 monitors significantly depends on the method of calibration. Static calibration curve is used as the most popular calibration method for low-cost PM2.5 sensors particularly because of ease of application. Drawback in this approach is, however, the lack of accuracy. Methods: This study discussed the calibration of a low-cost PM2.5-monitoring device (PMD) to improve the accuracy and reliability for practical use. The proposed method is based on construction of the PM2.5 sensor network using Message Queuing Telemetry Transport (MQTT) protocol and web query of reference measurement data available at government-authorized PM monitoring station (GAMS) in the republic of Korea. Four machine learning (ML) algorithms such as support vector machine, k-nearest neighbors, random forest, and extreme gradient boosting were used as regression models to calibrate the PMD measurements of PM2.5. Performance of each ML algorithm was evaluated using stratified K-fold cross-validation, and a linear regression model was used as a reference. Results: Based on the performance of ML algorithms used, regression of the output of the PMD to PM2.5 concentrations data available from the GAMS through web query was effective. The extreme gradient boosting algorithm showed the best performance with a mean coefficient of determination (R2) of 0.78 and standard error of 5.0 ㎍/㎥, corresponding to 8% increase in R2 and 12% decrease in root mean square error in comparison with the linear regression model. Minimum 100 hours of calibration period was found required to calibrate the PMD to its full capacity. Calibration method proposed poses a limitation on the location of the PMD being in the vicinity of the GAMS. As the number of the PMD participating in the sensor network increases, however, calibrated PMDs can be used as reference devices to nearby PMDs that require calibration, forming a calibration chain through MQTT protocol. Conclusions: Calibration of a low-cost PMD, which is based on construction of PM2.5 sensor network using MQTT protocol and web query of reference measurement data available at a GAMS, significantly improves the accuracy and reliability of a PMD, thereby making practical use of the low-cost PMD possible.

Estimation of Storm Hydrographs in a Small Forest Watershed Using a Distributed Hydrological Model (분포형 수문모형을 이용한 산림소유역의 홍수수문곡선의 추정)

  • Lee, Sang-Ho;Woo, Bo-Myeong;Im, Sang-Jun
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.1
    • /
    • pp.43-53
    • /
    • 2008
  • This study was conducted to simulate storm hydrographs on a small forested watershed using TOPMODEL, which is a distributed hydrological model. The Myeongseong watershed, which is 58.3 ha in size, was selected to monitor rainfall and runoff data. The Monte Carlo simulation was also used to calibrate parameters of TOPMODEL. Six rainfall-runoff pairs collected at the watershed in the year 1997 were used for parameter calibration, and eight rainfall-runoff pairs collected during the period of $1998\sim1999$ were used for validation effort. The errors of runoff volume ranged from -2.74% to 1.81%, and an average value of model efficiency in terms of runoff volume was 0.92 for the calibration period. The average value of observed peak discharge was $0.324m^3\;s^{-1}$ for six rainfall-runoff pairs, while the prediction value was $0.295m^3\;s^{-1}$. The simulation errors of peak discharge varied according to rainfall characteristics and antecedent condition, within ranges of -27.65% to -1.13%. The model efficiency for the validation period was 0.92. For the validation period, observed peak discharges have an average value of $0.087m^3\;s^{-1}$ and average value of simulated peak discharge was $0.090m^3\;s^{-1}$. Observed and simulated values of time to peak for the calibration period were 18.3 hrs and 11.0 hrs, respectively, and 16.6 hrs and 13.5 hrs, respectively, for the validation period.

Application of Normality Test and Classification of Process Capability Index (공정능력지수의 유형화 및 정규성 검정의 응용)

  • Choe, Seong-Un
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.11a
    • /
    • pp.551-556
    • /
    • 2011
  • This research presents an implementation strategy of Process Capability Index (PCI) according to the types of process characteristics. The types of process feature are classified as four perspectives of variation range, time period, error position, and process stage. The paper examines short-term or long-term PCI, within or between variation, position of precision or accuracy, and inclusion of measurement or calibration stage. Moreover, the study proposes normality test of unilateral PCI.

  • PDF

Experiment of KOMPSAT-3/3A Absolute Radiometric Calibration Coefficients Estimation Using FLARE Target (FLARE 타겟을 이용한 다목적위성3호/3A호의 절대복사 검보정 계수 산출)

  • Kyoungwook Jin;Dae-Soon Park
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1389-1399
    • /
    • 2023
  • KOMPSAT-3/3A (K3/K3A) absolute radiometric calibration study was conducted based on a Field Line of sight Automated Radiance Exposure (FLARE) system. FLARE is a system, which has been developed by Labsphere, Inc. adopted a SPecular Array Radiometric Calibration (SPARC) concept. The FLARE utilizes a specular mirror target resulting in a simplified radiometric calibration method by minimizing other sources of diffusive radiative energies. Several targeted measurements of K3/3A satellites over a FLARE site were acquired during a field campaign period (July 5-15, 2021). Due to bad weather situations, only two observations of K3 were identified as effective samples and they were employed for the study. Absolute radiometric calibration coefficients were computed using combined information from the FLARE and K3 satellite measurements. Comparison between the two FLARE measurements (taken on 7/7 and 7/13) showed very consistent results (less than 1% difference between them except the NIR channel). When additional data sets of K3/K3A taken on Aug 2021 were also analyzed and compared with gain coefficients from the metadata which are used by current K3/K3A, It showed a large discrepancy. It is assumed that more studies are needed to verify usefulness of the FLARE system for the K3/3A absolute radiometric calibration.

A Highly Expandable Forwarded-Clock Receiver with Ultra-Slim Data Lane using Skew Calibration by Multi-Phase Edge Monitoring

  • Yoo, Byoung-Joo;Song, Ho-Young;Chi, Han-Kyu;Bae, Woo-Rham;Jeong, Deog-Kyoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.4
    • /
    • pp.433-448
    • /
    • 2012
  • A source-synchronous receiver based on a delay-locked loop is presented. It employs a shared global calibration control between channels, yet achieves channel expandability for high aggregate I/O bandwidth. The global calibration control accomplishes skew calibration, equalizer adaptation, and phase lock of all the channels in a calibration period, resulting in the reduced hardware overhead and area of each data lane. In addition, the weight-adjusted dual-interpolating delay cell, which is used in the multiphase DLL, guarantees sufficient phase linearity without using dummy delay cells, while offering a high-frequency operation. The proposed receiver is designed in the 90-nm CMOS technology, and achieves error-free eye openings of more than 0.5 UI across 9-28 inch Nelco4000-6 microstrips at 4-7 Gb/s and more than 0.42 UI at data rates of up to 9 Gb/s. The data lane occupies only $0.152mm^2$ and consumes 69.8 mW, while the rest of the receiver occupies $0.297mm^2$ and consumes 56.0 mW at the 7- Gb/s data-rate and supply voltage of 1.35 V.