• 제목/요약/키워드: calibration center

검색결과 759건 처리시간 0.022초

자가보정법을 이용한 정밀 스테이지의 직각도 보정 (Orthogonality Calibration of a High Precision Stage using Self-calibration Method)

  • 김기현;박상현;김동민;장상돈
    • 한국정밀공학회지
    • /
    • 제27권3호
    • /
    • pp.50-57
    • /
    • 2010
  • A high precision air bearing stage has been developed and calibrated. This linear-motor driven stage was designed to transport a glass or wafer with the X and Y following errors in nanometer regime. To achieve this level of precision, bar type mirrors were adopted for real time ${\Delta}X$ and ${\Delta}Y$ laser measurement and feedback control. With the laser wavelength variation and instability being kept minimized through strict environment control, the orthogonality of this type of control system becomes purely dependent upon the surface flatness, distortion, and assembly of the bar mirrors. Compensations for the bar mirror distortions and assembly have been performed using the self-calibration method. As a result, the orthogonality error of the stage was successfully decreased from $0.04^{\circ}$ to 2.48 arcsec.

Effects of Long-term Exposure of High and Low Humidity on Thin-film Humidity Sensors

  • Lee, Sang-Wook;Choi, Byung Il;Kim, Jong Chul;Woo, Sang-Bong
    • 센서학회지
    • /
    • 제27권6호
    • /
    • pp.368-373
    • /
    • 2018
  • The effects of long-term exposure of high and low humidity on thin-film humidity sensors are investigated. Five commercially available thin-film humidity sensors are initially calibrated in a humidity chamber as a reference before longterm exposure to high and low humidity. Then, the sensors are kept in a high-humidity environment (~95 %rh) for four months. After the exposure, the sensors are calibrated in the same manner as the initial calibration. Consequently, the device reading values from the humidity sensors are elevated up to about 5 %rh. Interestingly, the degree of elevation by the high-humidity exposure shows a negative correlation with the price of the humidity sensors. Humidity sensors are then kept in a low-humidity environment (~10 %rh) for another four months. After the exposure, a calibration similar to the initial calibration is performed. As a result, the device reading from humidity sensors is decreased, indicating a recovery from the effect of high-humidity exposure. The durability test conducted in this study provides experimental evidence for the use of thin-film humidity sensors in high-humidity environments such as greenhouses and food factories for a long period of time.

ACTIVITIES OF CALIBRATION AND VALIDATION FOR THE KOMPSAT-2 MSC DATA

  • Lee Dong-Han;Lee Sun-Gu;Seo Doo-Chun;Song Jeong-Heon;Shih Jae-Min;Kim Yongseung;Lim Hyo-Suk;Paik Hong-Yul
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.620-623
    • /
    • 2005
  • KARI has prepared Calibration and Validation activities for the KOMPSAT-2 (KOrea Multi-Purpose SATellite-2) MSC data that will be launched at the end of this year. Firstly, we divided the Cal/Val activities of it to four parts, Spatial, Spectral, Radiometric and Geometric, and defmed the detailed Cal/Val items from them. Secondly, Cal/Val targets have been defined and manufactured for the role of them. Thirdly, we have made the plan and the procedure for the Cal/Val items, developed the codes for them, studied more detailed method to do them, and trained the Cal/Val activities using the foreign satellite image data by ourselves. KARI has been now setting up the KOMPSAT-2 LEOP plan with the Cal/Val activities, and probably will finish the EOP Cal/Val activities for the KOMPSAT-2 MSC data by the next April or May.

  • PDF

RGB color ratiomatric planar optode로 측정한 표층 퇴적물의 2차원 산소 분포 (Two-dimensional Oxygen Distribution in a Surface Sediment Layer Measured Using an RGB Color Ratiometric Oxygen Planar Optode)

  • 이재성;김은수;안성욱;김지혜;김종근;강성현;강동진
    • Ocean and Polar Research
    • /
    • 제35권3호
    • /
    • pp.229-237
    • /
    • 2013
  • We measured two-dimensional (2-D) oxygen distribution in the surface sediment layer of intertidal sediment using a simple and inexpensive planar oxygen optode, which is based on a color ratiometric image approach. The recorded emission intensity of red color luminophore light significantly changed with oxygen concentration by $O_2$ quenching of platinum(II)octaethylporphyrin (PtOEP). The ratios between the intensity of red and green emissions with oxygen concentration variation demonstrated the Stern-Volmer relationship. The 2-D oxygen distribution image showed microtopographic structure, diffusivity boundary layer and burrow in surface sediment layer. The oxygen penetration depth (OPD) was about 2 mm and the one-dimensional vertical diffusive oxygen uptake (DOU) was 12.6 mmol $m^{-2}d^{-1}$ in the undisturbed surface sediment layer. However, those were enhanced near burrow by benthic fauna, and the OPD was two times deeper and DOU was increased by 34%. The simple and inexpensive oxygen planar optode has great application potential in the study of oxygen dynamics with high spatiotemporal resolution, in benthic boundary layers.

원근 와핑 보정을 이용한 선광원 레이저 거리 검출 (Slit-light Laser Range Finding Using Perspective Warping Calibration)

  • 안현식
    • 융합신호처리학회논문지
    • /
    • 제11권3호
    • /
    • pp.232-237
    • /
    • 2010
  • 본 논문에서는 원근 와핑 보정을 이용한 선광원 레이저 거리 검출 시스템을 제안한다. 제안하는 방법은 카메라와 선광원의 선형성의 왜곡이 있을 경우에도 정확도를 높일 수 있는 장점이 있다. 먼저 보정 패널에 표시된 수직이면서 병렬로 배치된 보정점과 투사된 선광원 레이저의 중심 위치를 검출한다. 얻어진 선광원 레이저의 중심위치는 원근 와핑을 이용하여 가까이 있는 보정점들로부터 실제 좌표를 계산함으로써 보정 데이터를 구하고, 동일한 과정을 보정패널을 이동하면서 반복함으로써 보정 파일을 작성한다. 거리데이터 검출은 입력된 선광원 레이저 영상으로부터 중심위치를 구하고, 보정 파일에서 가장 가까운 보정 데이터를 찾아서 선형 보간으로 검출한다. 실험에서는 제안한 선광원 레이저 거리 검출 방법은 비선형적인 광학계에도 불구하고 130mm 깊이 범위에서 0.08mm 내의 오차로 거리 측정이 가능함을 보인다.

Standard calibration for H-α filter of DOAO 1m telescope

  • Ahn, Hojae;Pak, Soojong;Kang, Wonseok;Kim, Taewoo;Shim, Hyunjin
    • 천문학회보
    • /
    • 제42권2호
    • /
    • pp.89.1-89.1
    • /
    • 2017
  • In this poster, we present standard calibration processes and results for photometry of $H-{\alpha}$ filter using broadband filters. We took data from a night in stable weather condition. And we derived parameters for band pass calibration including color terms. The corrected photometry results from broadband filters like V and R filters showed high correlation enough to replace instrumental $H-{\alpha}$ magnitude. We plan to extend these standardizing processes to another narrowband filters and flux calibration of narrowband filters from photometry of PNe.

  • PDF

Calibration of Inertial Measurement Units Using Pendulum Motion

  • Choi, Kee-Young;Jang, Se-Ah;Kim, Yong-Ho
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제11권3호
    • /
    • pp.234-239
    • /
    • 2010
  • The utilization of micro-electro-mechanical system (MEMS) gyros and accelerometers in low-level inertial measurement unit (IMU) influences cost effectiveness in a positive way under the condition that device error characteristics are fully calibrated. The conventional calibration process utilizes a rate table; however, this paper proposes a new method for achieving reference calibration data from the natural motion of pendulum to which the IMU undergoing calibration is attached. This concept was validated with experimental data. The pendulum angle measurements correlate extremely well with the solutions acquired from the pendulum equation of motion. The calibration data were computed using the regression method. The whole process was validated by comparing the measurement from the 6 sensor components with the measurements reconstructed using the identified calibration data.

구속연산자에 의한 보정 시스템의 관측성에 관한 연구 (Study on the Observability of Calibration System with a Constraint Oprerator)

  • 이민기;김태성;박근우
    • 대한기계학회논문집A
    • /
    • 제27권4호
    • /
    • pp.647-655
    • /
    • 2003
  • This paper studies the observability of calibration system with a constraint movement by a constraint operator. The calibration system with the constraint movement need only simple sensing device to check whether the constraint movements are completed within an established range. However, it yields the concern about the poor parameter observability due to the constraint movements. This paper uses the QR-decomposition to find the optimal calibration configurations maximizing the linear independence of rows of a observation matrix. The number of identifiable parameters are examined by the rank of the observation matrix, which represents the parameter observability. The method is applied to a parallel typed machining center and the calibration results are presented. These results verify that the calibration system with low-cost indicators and simple planar table is accurate as well as reliable.

Absolute Radiometric Calibration for KOMPSAT-3 AEISS and Cross Calibration Using Landsat-8 OLI

  • Ahn, Hoyong;Shin, Dongyoon;Lee, Sungu;Choi, Chuluong
    • 한국측량학회지
    • /
    • 제35권4호
    • /
    • pp.291-302
    • /
    • 2017
  • Radiometric calibration is a prerequisite to quantitative remote sensing, and its accuracy has a direct impact on the reliability and accuracy of the quantitative application of remotely sensed data. This paper presents absolute radiometric calibration of the KOMPSAT-3 (KOrea Multi Purpose SATellite-3) and cross calibration using the Landsat-8 OLI (Operational Land Imager). Absolute radiometric calibration was performed using a reflectance-based method. Correlations between TOA (Top Of Atmosphere) radiances and the spectral band responses of the KOMPSAT-3 sensors in Goheung, South Korea, were significant for multispectral bands. A cross calibration method based on the Landsat-8 OLI was also used to assess the two sensors using near simultaneous image pairs over the Libya-4 PICS (Pseudo Invariant Calibration Sites). The spectral profile of the target was obtained from EO-1 (Earth Observing-1) Hyperion data over the Libya-4 PICS to derive the SBAF (Spectral Band Adjustment Factor). The results revealed that the TOA radiance of the KOMPSAT-3 agree with Landsat-8 within 5.14% for all bands after applying the SBAF. The radiometric coefficient presented here appears to be a good standard for maintaining the optical quality of the KOMPSAT-3.

Estimating the Important Components in Three Different Sample Types of Soybean by Near Infrared Reflectance Spectroscopy

  • Lee, Ho-Sun;Kim, Jung-Bong;Lee, Young-Yi;Lee, Sok-Young;Gwag, Jae-Gyun;Baek, Hyung-Jin;Kim, Chung-Kon;Yoon, Mun-Sup
    • 한국작물학회지
    • /
    • 제56권1호
    • /
    • pp.88-93
    • /
    • 2011
  • This experiment was carried out to find suitable sample type for the more accurate prediction and non-destructive way in the application of near infrared reflectance spectroscopy (NIRS) technique for estimation the protein, total amino acids, and total isoflavone of soybean by comparing three different sample types, single seed, whole seeds, and milled seeds powder. The coefficient of determination in calibration ($R^2$) and coefficient of determination in cross-validation (1-VR) for three components analyzed using NIRS revealed that milled powder sample type yielded the highest, followed by single seed, and the whole seeds as the lowest. The coefficient of determination in calibration for single seed was moderately low($R^2$ 0.70-0.84), while the calibration equation developed with NIRS data scanned with whole seeds showed the lowest accuracy and reliability compared with other sample groups. The scatter plot for NIRS data versus the reference data of whole seeds showed the widest data cloud, in contrary with the milled powder type which showed flatter data cloud. By comparison of NIRS results for total isoflavone, total amino acids, and protein of soybean seeds with three sample types, the powder sample could be estimated for the most accurate prediction. However, based from the results, the use of single bean samples, without grinding the seeds and in consideration with NIRS application for more nondestructive and faster prediction, is proven to be a promising strategy for soybean component estimation using NIRS.