• Title/Summary/Keyword: cadence

Search Result 440, Processing Time 0.024 seconds

KMTNet time-series photometry of the doubly eclipsing candidate stars in the LMC

  • Hong, Kyeongsoo;Lee, Jae Woo;Koo, Jae-Rim;Kim, Seung-Lee;Lee, Chung-Uk;Kim, Dong-Jin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.1
    • /
    • pp.44.2-44.2
    • /
    • 2017
  • Multiple stellar systems composed of triple, double+double or double+triple, etc. are very rare and interesting objects for understanding the star formation and dynamical evolution. However, only six systems have been found to be a doubly eclipsing quadruple, which consists of two eclipsing binaries, and four systems to be a triply eclipsing hierarchical triple. Recently, the 15 doubly eclipsing multiple candidates located in the Large Magellanic Cloud (LMC) have been reported by the OGLE project. In order to examine whether these candidates are real multiple systems with eclipsing features, we performed a high-cadence time-series photometry for the LMC using the KMTNet (Korea Microlensing Telescope Network) 1.6 m telescopes in three site (CTIO, SAAO, and SSO) during 2016-2017. The KMTNet data will help reveal the photometric properties of the multiple-star candidates. In this paper, we present the VI light curves and their preliminarily analyses for 12 of the 15 eclipsing systems in the LMC, based on our KMTNet observations and the OGLE-III survey data from 2001-2009.

  • PDF

Design of Low voltage High speed Phase Locked Loop (고속 저전압 위상 동기 루프(PLL) 설계)

  • Hwang, In-Ho;Cho, Sang-Bock
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.267-269
    • /
    • 2007
  • PLL(Phase Locked Loop) are widely used circuit technique in modern electronic systems. In this paper, We propose the low voltage and high speed PLL. We design the PFD(Phase Frequency Detector) by using TSPC (True Single Phase Clock) circuit to improve the performance and solve the dead-zone problem. We use CP(Charge Pump} and LP(Loop filter) for Negative feedback and current reusing in order to solve current mismatch and switch mismatch problem. The VCO(Voltage controlled Oscillator) with 5-stage differential ring oscillator is used to exact output frequency. The divider is implemented by using D-type flip flops asynchronous dividing. The frequency divider has a constant division ratio 32. The frequency range of VCO has from 200MHz to 1.1GHz and have 1.7GHz/v of voltage gain. The proposed PLL is designed by using 0.18um CMOS processor with 1.8V supply voltage. Oscillator's input frequency is 25MHz, VCO output frequency is 800MHz and lock time is 5us. It is evaluated by using cadence spectra RF tools.

  • PDF

Study on Rotating Speed of Kite Wind Turbine System and Design of PM Generator (연 풍력시스템의 회전속도 측정 및 발전기 시스템에 적용 가능한 영구자석 발전기 설계에 관한 연구)

  • Shin, Yujeong;Kim, Soo-Hyun;Kim, Jin Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.4
    • /
    • pp.141-147
    • /
    • 2016
  • A direct PM generator has the effect of reducing the mechanical noise and ease of maintenance by eliminating a number of power transmission components. In addition, wind turbines operating at low speed with the advantages of high output, high efficiency, and small size. The generator was designed as a small direct-drive PM generator that can be applied to a kite even at low wind speeds. The RPM (Revolutions Per Minute) of the reel was measured in two ways using a cadence/speedometer sensor and a tachometer while the actual kite. The RPM derived from the experiment was applied to the simulation on the designed generator. The no-load characteristic analysis for the magnetic fields produced for the permanent magnet generator by a permanent magnet and stator winding currents is achieved using a 2D coordinate system. A commercial electromagnetic analysis program, ANSYS Maxwell, was used to model the electromagnetic dynamics.

Influence on amputee gait by the ankle joint alignment (발목관절 조절각도가 절단환자의 보행에 미치는 영향)

  • Kim, Y.H.;Yang, G.T.;Lim, S.H.;Chang, Y.H.;Mun, M.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.369-372
    • /
    • 1997
  • Socket pressure distributions with gait analyses of a transfemoral and a transtibial prostheses were measured in order to assess an optimal socket fitting and unction. Ankle joint was aligned by the neutral and the dorsi/plantar flexed positions. Compared to dorsi and plantar flexed positions of ankle joint, cadence and walking speed increased with the neutral ankle joint alignment. Other gait parameters were close to the normative data with the neutral ankle joint alignment. For the transfemoral amputee, dorsiflexed alignment of the ankle joint created high pressure on the lateral aspect of the socket, on the other hand, plantarflexed alignment resulted in increased pressure on the medial aspect of the socket. For the transtibial amputee, dorsiflexed alignment of the ankle resulted in high pressure on the antero-lateral aspect of the socket during mid-stance, but plantarflexion of the ankle joint showed slight increases in pressure at the same location in the socket. The present study clearly demonstrated that malalignment of a prosthesis results in localized increasing pressure within the socket. Proper alignment of the prosthesis is required in order to acquire an appropriate socket-limb interface as well as the proper gait.

  • PDF

Effect of a PNF Training Program on Functional Assessment Measures and Gait Parameters in Healthy Older Adults (PNF 훈련 프로그램이 건강한 노인의 기능적 평가 측정과 보행에 미치는 효과)

  • Ma, Sang-Yeol;Kim, Hyeong-Dong
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.1
    • /
    • pp.39-45
    • /
    • 2010
  • Purpose: The purpose of this study was to examine changes in functional assessment measures (FAMs) and spatiotemporal gait parameters (STGPs) in healthy older adults before and after a 6-week intervention of a proprioceptive neuromuscular facilitation (PNF) training program. Methods: Thirty healthy older adults (mean age: $73.37{\pm}1.21$ age range: 65-79) were randomly assigned either to an experimental group (participating in a 6-week intervention of PNF training) or a control group (only performing daily activities). Participants in the control group did not receive any training program. Performance was assessed by recording changes in the FAMs and STGPs using functional assessment tools and GAITRite. Results: Participants in the PNF group showed significantly improved functional assessment measures and increased stride length, cadence, velocity, and step width (p<0.05). No significant differences in FAMs and STGPs were found in the control group (p>0.05). Conclusion: Participation in a PNF training program improves FAMs and STGPs, thereby increasing the ability of healthy older adults to maintain dynamic balance during functional performance and gait. These findings support the use of PNF training programs as effective fall-prevention programs for the elderly.

The Immediate Effects of Neck and Trunk Stabilization Exercises on Balance and Gait in Chronic Stroke Patients

  • Choe, Yu-Won;Kim, Myoung-Kwon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.15 no.4
    • /
    • pp.37-45
    • /
    • 2020
  • PURPOSE: The purpose of this study was to identify the effects of neck stabilization exercise combined with trunk stabilization exercise on balance and gait function in patients with chronic stroke. METHODS: Twenty-two chronic stroke patients were included in this study. The experimental group subjects (n = 11) performed neck stabilization (15 min) and trunk stabilization (15 min) exercises, while the control group subjects (n = 11) performed trunk stabilization exercise only for 30 min. Before and after the intervention, the subjects underwent static balance and gait testing. RESULTS: The 95% confidence ellipse area, center of pressure (COP) path length, and COP average velocity were significantly lower in both groups after the intervention compared to before intervention (p < .05). The average stance force on the affected side increased significantly in both groups after the intervention (p < .05). The changes in the static balance variables were larger in the experimental group than in the control group. The cadence, gait velocity, and single leg support increased significantly in both groups after intervention (p < .05). The changes in the gait variables were larger in the experimental group than in the control group. CONCLUSION: Trunk stabilization is a beneficial intervention, but the combination of neck stabilization with trunk stabilization is a more effective method to increase the gait and static balance in chronic stroke patients.

The Effect of Footwear on Gait in Older Adults (신발의 형태가 노인의 보행에 미치는 영향)

  • Lee, Yun-Kyung;Bae, Sung-Soo;Han, Jin-Tae
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.2 no.2
    • /
    • pp.161-171
    • /
    • 2007
  • Purpose : The purpose of this study was to evaluate the effect of footwear on gait in older adults. Methods : The footwear consists of loafer with fixation and mule and slipper without fixation. Twenty one female older adults voluntarily participated in this study. Each participant walked on the gait system GAITRite and measured temporal-spatial gait parameters. And the participants wore loafer, mule, slipper randomly. We measured stance time, swing time, heel-to-heel BOS, double support time, velocity, cadence, FAP as temporal-spatial gait parameters. Results : Three gait parameters showed significant difference statistically among 7 gait parameters. The stance time increased as loafer, mule, barefoot, slipper orderly. And there was a significant difference statistically (p<.05). The swing time increased as slipper, barefoot, mule, loafer orderly. And there was a significant difference statistically(p<.05). And the heel-to-heel BOS increased as barefoot, loafer, mule, slipper orderly. And there was a significant difference statistically(p<.05) according to footwear type. Conclusion : The footwear type with high stability like loafer is considered better than footwear type with low stability like mule and slipper for the elderly.

  • PDF

A Study on Kinetic Gait Analysis of the Normal Adult (정상 성인의 운동역학적 보행분석)

  • Kim, Geon;Yoon, Na-Mi
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.2
    • /
    • pp.87-95
    • /
    • 2009
  • Purpose: This study reports the basic reference data of the specific gait parameters for Korean normal adults. Methods: The basic gait parameters were extracted from 73 Adults (35 men and 38 women), 18 to 33 years of age, using a Vicon MX motion analysis system. The segment kinetics, such as joint moment and power, was analyzed at the hip, knee and ankle. Results: The motion patterns are typically associated with a specific phase of the gait cycle. The temporal-spatial gait parameters of Korean normal adults, such as cadence, walking speed, stride length, single support and double support, were similar to the other western reference data. The kinetic parameters of Korean normal adults, such as joint moments of force, joint mechanical power generation or absorption and ground reaction forces, were also similar to other western reference datasets. Conclusion: This study demonstrates that objective gait analysis can be used to document the gait patterns of normal healthy adults. The techniques of 3-dimensional temporal-spatial gait parameters and kinematic parameters analysis can provide a detailed biomechanical description of a normal and pathological gait.

  • PDF

Design of ENMODL CLA for Low Power High Speed Multipier (고속 저전력 곱셈기에 적합한 ENMODL CLA 설계)

  • 백한석;한석붕
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.4
    • /
    • pp.91-96
    • /
    • 2001
  • In this paper we propose a new ENMODL(Enhanced-NORA-MODL) CLA(Carry-Look Ahead Adder) for high speed and low power multiplier. To reduce transistor counts, area and power dissipation we developed new-approaches. The method makes use of a dynamic CMOS logic ENMODL CLA. The advantage of ENMODL is small area and high speed The speed of ENMODL CLA is invreased by 6.27 % as compared with conventional NMOCL CLA. The proposed method was verified by HSPICE simulation and layout througth 0.6${\mu}{\textrm}{m}$ CMOS process.

  • PDF

The Design and Fabrication of Capacitive Humidity Sensor Having Interdigit Electrodes and its Signal Conditional Circuitry (빗살형 전극을 가지는 정전용량형 습도센서와 그 신호처리회로의 설계와 제작)

  • Park, Se-Kwang;Kang, Jeong-Ho;Park, Jin-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.3
    • /
    • pp.144-148
    • /
    • 2001
  • For the purpose of developing capacitive humidity sensor having interdigit electrodes, interdigit electrode was modeled and simulated to obtain capacitance and sensitivity as a function of geometric parameters like the structural gap and thichness. For the development of ASIC, switched capacitor signal conditioning circuits for capacitive humidity sensor were designed and simulated by cadence using 0.25um CMOS process parameters. The signal conditioning circuits are composed of amplifier for voltage gain control, and clock generator for sensor driving and switch control The characteristics of the fabricated sensors are; 1) sensitivity is 9fF/%R.H., 2) temperature coefficient of offset(TCO) is 0.4%R.H./$^{\circ}C$, 3) nonlinearity is 1.2%FS, 4) hysteresis is 1.5%FS in humidity range of 3%R.H. ${\sim}$ 98%R.H.. The response time is 50 seconds in adsorption and 70 seconds in desorption. Fabricated process used in this capacitive humidity sensor having interdigit electrode are just as similar as conventional IC process technology. Therefore this can be easily mass produced with low cost, simple circuit and utilized in many applications for both industrial and environmental measurement and control system, such as monitoring system of environment, automobile, displayer, IC process room, and laboratory etc..

  • PDF