• 제목/요약/키워드: cadaveric testing

검색결과 8건 처리시간 0.019초

The Changes in Range of Motion after a Lumbar Spinal Arthroplasty with Charite$^{TM}$ in the Human Cadaveric Spine under Physiologic Compressive Follower Preload: A Comparative Study between Load Control Protocol and Hybrid Protocol

  • Kim, Se-Hoon;Chang, Ung-Kyu;Chang, Jae-Chil;Chun, Kwon-Soo;Lim, T. Jesse;Kim, Daniel H.
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권2호
    • /
    • pp.144-151
    • /
    • 2009
  • Objective: To compare two testing protocols for evaluating range of motion (ROM) changes in the preloaded cadaveric spines implanted with a mobile core type Charite$^{TM}$ lumbar artificial disc. Methods: Using five human cadaveric lumbosacral spines (L2-S2), baseline ROMs were measured with a bending moment of 8 Nm for all motion modes (flexion/extension, lateral bending, and axial rotation) in intact spine. The ROM was tracked using a video-based motion-capturing system. After the Charite$^{TM}$ disc was implanted at the L4-L5 level, the measurement was repeated using two different methods: 1) loading up to 8 Nm with the compressive follower preload as in testing the intact spine (Load control protocol), 2) loading in displacement control until the total ROM of L2-S2 matches that when the intact spine was loaded under load control (Hybrid protocol). The comparison between the data of each protocol was performed. Results: The ROMs of the L4-L5 arthroplasty level were increased in all test modalities (p < 0.05 in bending and rotation) under both load and hybrid protocols. At the adjacent segments, the ROMs were increased in all modes except flexion under load control protocol. Under hybrid protocol, the adjacent segments demonstrated decreased ROMs in all modalities except extension at the inferior segment. Statistical significance between load and hybrid protocols was observed during bending and rotation at the operative and adjacent levels (p< 0.05). Conclusion: In hybrid protocol, the Charite$^{TM}$ disc provided a relatively better restoration of ROM, than in the load control protocol, reproducing clinical observations in terms of motion following surgery.

Effect of Device Rigidity and Physiological Loading on Spinal Kinematics after Dynamic Stabilization : An In-Vitro Biomechanical Study

  • Chun, Kwonsoo;Yang, Inchul;Kim, Namhoon;Cho, Dosang
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권5호
    • /
    • pp.412-418
    • /
    • 2015
  • Objective : To investigate the effects of posterior implant rigidity on spinal kinematics at adjacent levels by utilizing a cadaveric spine model with simulated physiological loading. Methods : Five human lumbar spinal specimens (L3 to S1) were obtained and checked for abnormalities. The fresh specimens were stripped of muscle tissue, with care taken to preserve the spinal ligaments and facet joints. Pedicle screws were implanted in the L4 and L5 vertebrae of each specimen. Specimens were tested under 0 N and 400 N axial loading. Five different posterior rods of various elastic moduli (intact, rubber, low-density polyethylene, aluminum, and titanium) were tested. Segmental range of motion (ROM), center of rotation (COR) and intervertebral disc pressure were investigated. Results : As the rigidity of the posterior rods increased, both the segmental ROM and disc pressure at L4-5 decreased, while those values increased at adjacent levels. Implant stiffness saturation was evident, as the ROM and disc pressure were only marginally increased beyond an implant stiffness of aluminum. Since the disc pressures of adjacent levels were increased by the axial loading, it was shown that the rigidity of the implants influenced the load sharing between the implant and the spinal column. The segmental CORs at the adjacent disc levels translated anteriorly and inferiorly as rigidity of the device increased. Conclusion : These biomechanical findings indicate that the rigidity of the dynamic stabilization implant and physiological loading play significant roles on spinal kinematics at adjacent disc levels, and will aid in further device development.

Measures of micromotion in cementless femoral stems-review of current methodologies

  • Solitro, Giovanni F;Whitlock, Keith;Amirouche, Farid;Santis, Catherine
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제3권2호
    • /
    • pp.85-104
    • /
    • 2016
  • Stability and loosening of implanted femoral stems in Total Hip Replacement have been well established as barriers to the primary concerns of osseointegration and long term implant survival. In-vitro experiments and finite element modeling have for years been used as a primary tool to assess the bone stem interface with variable methodologies leading to a wide range of micromotion, interference fit and stress shielding values in the literature. The current study aims to provide a comprehensive review of currently utilized methodologies for in-vitro mechanical testing as well as finite element modeling of both micromotion and interference of implanted femoral stems. A total of 12 studies detailed in 33 articles were selected for inclusion. Experimental values of micromotion ranged from 12 to $182{\mu}m$ while finite element analysis reported a wider range from 2.74 to $1,277{\mu}m$. Only two studies were found that modeled bone/implant contact with consideration for interference fit. In studies evaluating stem micromotion in THA, the reference surface at the bone/stem interface should be well defined. Additionally, the amount of penetration considered should be disclosed and associated with bone density and roughness.

Scapular spine base fracture with long outside-in superior or posterior screws with reverse shoulder arthroplasty

  • Eroglu, Osman Nuri;Husemoglu, Bugra;Basci, Onur;Ozkan, Mustafa;Havitcioglu, Hasan;Hapa, Onur
    • Clinics in Shoulder and Elbow
    • /
    • 제24권3호
    • /
    • pp.141-146
    • /
    • 2021
  • Background: The purpose of the present study was to determine how long superior screws alone or in combination with posterior placement of metaglene screws protruding and penetrating into the scapular spine in reverse total shoulder arthroplasty affect the strength of the scapular spine in a fresh cadaveric scapular model. Methods: Seven fresh cadaver scapulas were allocated to the control group (short posterior and superior screws) and seven scapulars to the study group (spine base fixation with a four long screws, three with both long superior and long posterior screws). Results: The failure load was lower in the spine fixation group (long screw, 869 N vs. short screw, 1,123 N); however, this difference did not reach statistical significance (p>0.05). All outside-in long superior or superior plus posterior screws failed due to scapular spine base fracture; failures in the short screw group were due to acromion fracture. An additional posterior outside-in screw failed to significantly decrease the failure load of the acromion spine. Conclusions: The present study highlights the significance of preventing a cortical breach or an outside-in configuration when a superior or posterior screw is inserted into the scapular spine base.

Biomechanical investigation of arm position on deforming muscular forces in proximal humerus fractures

  • Christen E. Chalmers;David J. Wright;Nilay A. Patel;Hunter Hitchens;Michelle McGarry;Thay Q. Lee;John A. Scolaro
    • Clinics in Shoulder and Elbow
    • /
    • 제25권4호
    • /
    • pp.282-287
    • /
    • 2022
  • Background: Muscular forces drive proximal humeral fracture deformity, yet it is unknown if arm position can help mitigate such forces. Our hypothesis was that glenohumeral abduction and humeral internal rotation decrease the pull of the supraspinatus and subscapularis muscles, minimizing varus fracture deformity. Methods: A medial wedge osteotomy was performed in eight cadaveric shoulders to simulate a two-part fracture. The specimens were tested on a custom shoulder testing system. Humeral head varus was measured following physiologic muscle loading at neutral and 20° humeral internal rotation at both 0° and 20° glenohumeral abduction. Results: There was a significant decrease in varus deformity caused by the subscapularis (p<0.05) at 20° abduction. Significantly increasing humeral internal rotation decreased varus deformity caused by the subscapularis (p<0.05) at both abduction angles and that caused by the supraspinatus (p<0.05) and infraspinatus (p<0.05) at 0° abduction only. Conclusions: Postoperative shoulder abduction and internal rotation can be protective against varus failure following proximal humeral fracture fixation as these positions decrease tension on the supraspinatus and subscapularis muscles. Use of a resting sling that places the shoulder in this position should be considered.

Pullout Strength after Expandable Polymethylmethacrylate Transpedicular Screw Augmentation for Pedicle Screw Loosening

  • Kang, Suk-Hyung;Cho, Yong Jun;Kim, Young-Baeg;Park, Seung Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제57권4호
    • /
    • pp.229-234
    • /
    • 2015
  • Objective : Pedicle screw fixation for spine arthrodesis is a useful procedure for the treatment of spinal disorders. However, instrument failure often occurs, and pedicle screw loosening is the initial step of a range of complications. The authors recently used a modified transpedicular polymethylmethacrylate (PMMA) screw augmentation technique to overcome pedicle screw loosening. Here, they report on the laboratory testing of pedicle screws inserted using this modified technique. Methods : To evaluate pullout strengths three cadaveric spinal columns were used. Three pedicle screw insertion methods were utilized to compare pullout strength; the three methods used were; control (C), traditional transpedicular PMMA augmentation technique (T), and the modified transpedicular augmentation technique (M). After control screws had been pulled out, loosening with instrument was made. Screw augmentations were executed and screw pullout strength was rechecked. Results : Pedicle screws augmented using the modified technique for pedicle screw loosening had higher pullout strengths than the control ($1106.2{\pm}458.0N$ vs. $741.2{\pm}269.5N$; p=0.001). Traditional transpedicular augmentation achieved a mean pullout strength similar to that of the control group ($657.5{\pm}172.3N$ vs. $724.5{\pm}234.4N$; p=0.537). The modified technique had higher strength than the traditional PMMA augmentation technique ($1070.8{\pm}358.6N$ vs. $652.2{\pm}185.5N$; p=0.023). Conclusion : The modified PMMA transpedicular screw augmentation technique is a straightforward, effective surgical procedure for treating pedicle screw loosening, and exhibits greater pullout strength than traditional PMMA transpedicular augmentation. However, long-term clinical evaluation is required.

동종조직이식술시 전염성질환의 이환가능성에 대한 고찰 II: 동종연조직 (THE REVIEW OF TRANSMISSION OF INFECTIOUS DISEASE IN HUMAN TISSUE TRANSPLANTATION: PHASE II. ALLOGENIC SOFT TISSUES)

  • 이은영;김경원;엄인웅
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제29권3호
    • /
    • pp.262-267
    • /
    • 2007
  • Implantation of allografts has increased widely with not only the availability of many allogenic bone but also allogenic soft tissues. The aim of tissue banking is to provide surgeons with safe tissues compatible with their intended clinical application. The incidence of tissue transplant-transmitted infection is unknown and can only be inferred from prospective studies. The possibility of donor-to-recipient disease transmission through soft tissue transplantation can be considered by reviewing the risk associated with other transplanted hard tissues. Viral, bacterial, and fungal infections have been transmitted via transplantation of soft tissue allografts such as skin, cornea, dura, pericardium. fascia lata, and heart valves. Corneas have transmitted rabies, Creutzfeldt-Jakob disease (CJD), hepatitis B (HBV), cytomegalovirus (CMV), herpes simplex virus (HSV), bacteria, and fungi. Heart valves have been implicated in transmitting tuberculosis, hepatitis B. HIV-1 and CMV. CJD has been transmitted by dura and pericardium transplants. Skin has transmitted CMV, bacteria, and fungi. Cadaveric skin, pericardium, dura, and fascia lata have been used in dental patients with intra-oral soft tissue injuries and GBR. This study is review of the considering transmission of infectious disease in allogenic soft tissues and guidelines of reducing the risk. Prior to use, many tissues are exposed to antibiotics, disinfectants, and sterilants, which further reduce or remove the risk of transmitted disease. Because some soft tissue grafts cannot be subjected to sterilization steps, the risk of infectious disease transmission remains and thorough donor screening and testing is especially important.

경추부의 후관절 나사못 고정술에서 단피질삽입법과 양피질 삽입법 간의 특성에 관한 비교 (Comparisons of Unicortical and Bicortical Lateral Mass Screws in the Cervical Spine : Safety vs Strength)

  • 박춘근;황장회;지철;이재언;성재훈;최승진;이상원;;박성찬;조경석;박춘근;강준기
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권10호
    • /
    • pp.1210-1219
    • /
    • 2001
  • 서 론 : 후방 경유 경추 융합을 위한 후관절 금속판 고정술은 외상성 및 퇴행성 불안정성의 치료에 효과적인 방법이다. 후관절 금속판 고정의 안정성은 여러 가지 인자에 의해 결정된다. 이중 하나가 나사못의 삽입깊이이다. 이 방법이 처음 소개될 때에는 양피질골성 삽입이 이용되었다. 외과의사의 관심은 어떻게 안전하면서 생역학적으로 강력한 고정을 얻느냐에 있다. 목 적 : 이 연구의 목적은 사체에서 단피질성과 양피질성 나사못 삽입술을 시행한 후 안전성, pull-out 강도, 방사선학적 특성을 분석하고 나사못의 삽입에 대한 교육 훈련의 수준에 따른 영향을 평가하는데 있다. 방 법 : 평균 나이 78.9세인 21구의 사체에 대하여, Magerl의 기술을 변형하여 C3-C6(n=168)까지 3.5mm AO 나사못을 양쪽 후관절에 삽입하였다. 수술중 방사선 사진영상은 사용되지 않았다. 오른 쪽(단피질성 삽입)은 14mm 나사못(11mm의 유효 길이)을 이용하고, 왼쪽은 양피질성 삽입을 시도하였다. 각 사체는 3개의 군으로 나누어 척추 수술 수련의 수준이 다른 받은 3명의 척추 외과 의사들(전임 강사, 임상 강사, 수석 레지던트)이 수술을 시행했다. 수술 후 경추를 떼어내어 나사못의 위치를 육안적으로 확인하고 방사선학적으로 안정성과 삽입 위치 (1,2,3)를 평가하였다. 척수, 후관절, 신경근과 척추 동맥에 대한 나사못의 위치를"만족할 만한","위험한", 그리고"직접적인 손상"으로 구분하였다. material testing machine을 이용하여 모든 나사못에 대해서 Pull-out 강도를 측정하였다. 결 과 : 대다수의 나사못(92.9%)은 만족할 만한 상태였다. 전예에서 척수에 대한 위험성은 없다. 오른 편(단피질성 : 14mm) 나사못의 98.9%는"만족할 만한"에 속했다. 그리고 왼쪽 편(양피질성)의 68.1%는"만족할 만한"에 속했다. 양피질성 나사못 군에서 5.8%의 척추 동맥에 대한 직접적인 손상이 있었고 신경근의 직접적인 손상 발생율은 17.4%였다. 반면에 단피질성 나사못 군에서는 이들에 대한 직접적인 손상은 없었다. 양피질성 나사못에서 보인"직접 손상"의 거의 대부분은 외과 의사의 경험 부족으로 발생하였다. 나사못의 안정성과 삽입 위치 사이에는 특별한 관련이 없었다. 모든 나사못의 pull-out 강도는 $542.0{\pm}296.6N$였다. 단피질성에 있어서의 pull-out 강도($519.0{\pm}289.9N$)와 양피질성($565.2{\pm}306N$) 나사못에는 아무런 통계학적으로 의미있는 차이점을 발견할 수 없었다(p>0.05). 나사못 삽입위치와 pull-out 강도 사이에는 의미있는 차이가 없었다. 결 론 : 이번 연구는 경추 후관절 나사못 고정술시 단피질성과 양피질성 나사못의 안정성과 효능을 집중적으로 알아보았다. 명백한 것은 14mm의 나사못(효과적인 길이는 11mm)이 보다 긴 양피질성 나사못 보다 손상의 위험이 훨씬 낮고 거의 동등한 pull-out강도를 갖는다는 것이다. 또한, 수술시 방사선 영상을 사용할 수 없을 때, 훈련과 축적된 경험에 의해 나사못 삽입의 정확성과 안전성이 향상될 수 있다.

  • PDF