• Title/Summary/Keyword: cadaver

Search Result 210, Processing Time 0.027 seconds

The Trapezius Muscle Flap: A Viable Alternative for Posterior Scalp and Neck Reconstruction

  • Yang, Hee Jun;Lee, Dong Hun;Kim, Yang Woo;Lee, Sang Gu;Cheon, Young Woo
    • Archives of Plastic Surgery
    • /
    • v.43 no.6
    • /
    • pp.529-535
    • /
    • 2016
  • Background The trapezius muscle flap is not usually the first reconstructive option for skin and soft tissue defects in the posterior neck and scalp due to surgeons' unfamiliarity with the surgical anatomy and developments in free tissue transfer techniques. The goals of this study were to describe the clinical use of trapezius flaps in posterior neck and scalp reconstruction, and to investigate the vascular anatomy of trapezius flaps in Asians in order to obtain information facilitating the safe design and elevation of flaps in which most of the muscle is preserved. Methods A retrospective chart review was performed of 10 patients who underwent trapezius muscle flap for posterior neck and scalp defects. We also performed an anatomical study of 16 flaps harvested from 8 preserved Asian adult cadavers and evaluated the main landmarks relevant for trapezius muscle flap. Results In the anatomical study, the mean vertical height from the inferior angle of the scapula to the point at which the superficial cervical artery penetrated the trapezius was $4.31{\pm}2.14cm$. The mean vertical height of the trapezius muscle flap pivot point was $9.53{\pm}2.08cm$ from the external occipital protuberance. Among the 10 flaps, partial necrosis on the overlaid skin graft occurred in 1 patient and postoperative seroma occurred in another patient. Conclusions Vascular variations in the trapezius muscle flap are uncommon in Asians, but when present, such variations appear to have little impact on harvesting the flap or on its circulation. The trapezius muscle flap is a viable alternative for posterior neck and scalp reconstruction.

Anatomical Study of Interdigital Neuroma Occurring Site and the Deep Transverse Metatarsal Ligament (DTML) (지간 신경종 발생 위치와 심부 횡 중족 골간 인대의 해부학적 연구)

  • Kim, J-Young;Choi, Jae-Hyuck;Lee, Kyung-Tai;Young, Ki-Won;Park, Jung-Min
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.2
    • /
    • pp.182-186
    • /
    • 2007
  • Purpose: We examined the relationship of interdigital neuroma occurring site and the surrounding structures, including the deep transverse metatarsal ligament (DTML) by cadaver study and clinical results. Materials and Methods: Seventeen fresh frozen cadavers study were done to evaluate the relationship of interdigital neuroma occuring site and the DTML at two phase of the gait cycle with 60 degree of metatarsophalangeal dorsiflexion and with 15 degrees of ankle dorsiflexion. We measured the distance from interdigital nerve bifurcation of the common digital nerve to anterior margin of the DTML and longitudinal length of DTML itself. Clinically, we checked the location of interdigital neuroma and DTML length during surgery in 32 feet. Results: In the second and third web space, the mean distance from bifurcation of the common digital nerve of foot to the anterior margin of DTML was 16.7 mm, 15.1 mm in the mid-stance position, and 15.9 mm. 14.6 mm in heel-off position. Second, Third web space ligament itself length were average 12.8 mm, 10.6 mm. Clinically, all of the cases of interdigital neuroma started at the bifurcation area of the common digital nerve and interdigital neuroma was average 7.5 mm (range; 6-11 mm). Conclusion: Interdigital neuroma were located more distally than DTML in both the mid-stance and heel off stage. The main lesion was located between metatarsal head and metatarsophalangeal joint and more distal than the DTML anterior margin.

  • PDF

Anatomical Study on the Foot Soeum Meridian Muscle in Human (사람에 있어 족소음경근의 해부학적 고찰)

  • Park, Kyoung-Sik
    • Korean Journal of Acupuncture
    • /
    • v.29 no.2
    • /
    • pp.239-249
    • /
    • 2012
  • Objectives : This study was investigated to observe Foot Soeum Meridian Muscle in human. Methods : In order to expose components related to Foot Soeum Meridian Muscle, cadaver was dissected in the order of their depth; being respectively divided into superficial, middle, and deep layer. Results : Anatomical components related to Foot Soeum Meridian Muscle in human are composed of muscles such as flexor digitorum brevis tendon, abductor hallucis muscle, psoas major m., erector spinae m., and flexor retinaculum, fascia such as plantar aoneurosis, ligament such as sacrotuberal ligament, sacrospinous lig., nuchal lig., nerves such as plantar cut. br. of med. plantar nerve, med. crural cut. br. of saphenous n., br. of tibial n., post. femoral cut. n., spinal n.(dorsal rami of C4-6, T7-12, L1-3, and S1-3), and autonomic nervous system(sacral plexus, pelvic splanchnic n., etc.), and etc. Conclusions : This study shows comparative differences from established studies on anatomical components related to Foot Soeum Meridian Muscle, and the methodical aspects of analytic process. In addition, Foot Soeum Meridian Muscle in human is a comprehensive concept including the relevant nerves, but it remains questionable.

Skin Thickness of the Anterior, Anteromedial, and Anterolateral Thigh: A Cadaveric Study for Split-Skin Graft Donor Sites

  • Chan, Jeffrey C.Y.;Ward, John;Quondamatteo, Fabio;Dockery, Peter;Kelly, John L.
    • Archives of Plastic Surgery
    • /
    • v.41 no.6
    • /
    • pp.673-678
    • /
    • 2014
  • Background The depth of graft harvest and the residual dermis available for reepithelization primarily influence the healing of split-skin graft donor sites. When the thigh region is chosen, the authors hypothesize based on thickness measurements that the anterolateral region is the optimal donor site. Methods Full-thickness skin specimens were sampled from the anteromedial, anterior, and anterolateral regions of human cadavers. Skin specimens were cut perpendicularly with a custom-made precision apparatus to avoid the overestimation of thickness measurements. The combined epidermal and dermal thicknesses (overall skin thickness) were measured using a digital calliper. The specimens were histologically stained to visualize their basement membrane, and microscopy images were captured. Since the epidermal thickness varies across the specimen, a stereological method was used to eliminate observer bias. Results Epidermal thickness represented 2.5% to 9.9% of the overall skin thickness. There was a significant difference in epidermal thickness from one region to another (P<0.05). The anterolateral thigh region had the most consistent and highest mean epidermal thickness ($60{\pm}3.2{\mu}m$). We observed that overall skin thickness increased laterally from the anteromedial region to the anterior and anterolateral regions of the thigh. The overall skin thickness measured $1,032{\pm}435{\mu}m$ in the anteromedial region compared to $1,220{\pm}257{\mu}m$ in the anterolateral region. Conclusions Based on skin thickness measurements, the anterolateral thigh had the thickest epidermal and dermal layers. We suggest that the anterolateral thigh region is the optimal donor site for split-skin graft harvests from the thigh.

Development of Local-Exposure Systems for In Vivo Studies at Mobile-Phone Frequency Bands (이동통신 주파수 대역에서의 동물 실험용 국부 노출 장치 개발)

  • Ko Chea-Ok;Park Min-Young;Doh Hyeon-Jeong;Kim Jeong-Lan;Jung Ki-Bum;Pack Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.5 s.108
    • /
    • pp.451-460
    • /
    • 2006
  • We have designed local exposure systems for long-time mice experiments in PCS and cellular frequency band(PCS: 1,762.5 MHz, cellular: 848.5 MHz). The fabricated systems are local exposure systems of carousel type, and 40 mice can be exposed at a time. In order not to give extra stress to the mice ender experiment, the systems were fabricated to meet the environmental conditions such as illumination, ventilation, noise etc. SAR measurement was performed using a temperature probe. Measurements at 3 points in the head of mouse cadaver and solid phantom were made, and it has been confirmed that the measurement results are in good agreement with the simulation results in the real exposure environment. The exposure systems are currently used for long-term mice experiments.

Labial and lingual/palatal bone thickness of maxillary and mandibular anteriors in human cadavers in Koreans

  • Han, Ji-Young;Jung, Gyu-Un
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.2
    • /
    • pp.60-66
    • /
    • 2011
  • Purpose: The aim of this study is to evaluate the buccal and lingual bone thickness in the anterior teeth and the relationship between bone thickness and the tissue biotype. Methods: Three male and two female human cadaver heads (mean age, 55.4 years) were used in this study. First, the biotype of periodontium was evaluated and categorized into a thick or a thin group. Next, full thickness reflections of the mandible and the maxilla to expose the underlying bone for accurate measurements in the anterior regions were performed. After the removal of the half of the alveolar bone, the probe with a stopper was used to measure the thickness of bone plate at the alveolar crest (AC), 3 mm apical to the alveolar crest (AC-3), 6 mm apical to the alveolar crest (AC-6), and 9 mm apical to the alveolar crest (AC-9). The thickness of the buccal plates at the alveolar crest were $0.97{\pm}0.18\;mm$,$0.78{\pm}0.21\;mm$, and $0.95{\pm}0.35\;mm$ in the maxillary central incisors, lateral incisors, and canines, respectively. The thickness of the labial plates at the alveolar crest were $0.86{\pm}0.59\;mm$, $0.88{\pm}0.70\;mm$, and $1.17{\pm}0.70\;mm$ in the mandibular central incisors, lateral incisors and canines, respectively. Conclusions: The thickness of the labial plate in the maxillary anteriors is very thin that great caution is needed for placing an implant. The present study showed the bone thickness of maxillary and mandibular anteriors at different positions. Therefore, these data can be useful for the understanding of the bone thickness of the anteriors and a successful implant placement.

Micro-Structural Profiles of Trabecular Bone at the Ankle Joint (족관절 해면골의 미세 구조 분석)

  • Kim, Hyon-Jeong;An, Tae-Sun;Baek, Myong-Hyun;Choi, Mun-Kwon;Won, Ye-Yeon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.2
    • /
    • pp.157-160
    • /
    • 2004
  • Purpose: This study aimed to investigate and compare the micro-structural profiles of trabecular bone from different facets at the ankle joint. Materials and Methods: In a fresh cadaver ankle, four cored 10 mm of diameter cylindrical specimens of trabecular bone were harvested from the distal tibia, the talar dome, the medial malleolus, and the lateral malleolus. Using a micro-computed tomography, two-dimensional and three-dimensional micro-structural indices of the trabecular bone were analyzed. Results: Each specimen from the tibia, talus, medial malleolus, and the lateral malleolus showed unique micro-structural pattern. Tibia versus talus, the talus was seen a higher bone volume fraction and a wider supporting zone subchondrally whereas the tibia was seen a relatively lower bone volume fraction and a much narrower supporting zone subchondrally. Lateral malleolus versus medial malleolus, the lateral malleolus was seen the thicker but sparse trabeculae pattern whereas the medial malleolus was seen the thinner but more compact trabecular pattern. Conclusion: Each four locations from the different facet at the ankle joint have distinct own micro-structural patterns of the trabecular bone, suggesting different mechanical properties.

  • PDF

Range of Motion of Great Toe after Sesamoidectomy: A Cadaveric Study (종자골 절제 후 족무지 관절의 운동 변화)

  • Chung, Hyun-Wook;Kim, Jin-Goo;Lee, Woo-Chun;Moon, Jeong-Seok;Suh, Jin-Soo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.2
    • /
    • pp.138-141
    • /
    • 2009
  • Purpose: Regardless of potential and actual complications, the sesamoidectomy either tibial side or fibular side or both, had been used as a surgical option for various pathologic conditions. The objective of this cadaveric study was to identify the changes of range of motion of great toe after sesamoidectomy. Material and Methods: Eight fresh cadaver legs were used. The angular changes of the hallucal articulations were measured by traction of the flexor hallucis longus tendon at the proximal border of fibro-osseous tarsal tunnel and by traction of the extensor hallucis longus tendon at the superior border of inferior extensor retinaculum. The measurement started at neutral position and proceeded to the maximum for respective tendons. After sesamoidectomy either partial or total, same procedures were repeated and the angular changes were measured. Results: In flexion of great toe, there were significant metatarsophalangeal angular differences at 1 cm traction in total sesamoidectomy and lateral sesamoidectomy. In extension of great toe, there were significant metatarsophalangeal angular differences at more than 2 cm traction in total sesamoidectomy. In other measurements, there were no significant angular changes of the hallucal articulations. Conclusion: The sesamoidectomy resulted in change of motion of great toe. Statistical analysis showed that the significant increases in the initial flexion and maximal extension occurred with total sesamoidectomy and the significant increase in the initial flexion occurred with lateral sesamoidectomy.

  • PDF

Pedicle Screw Placement in the Thoracolumbar Spine Using a Novel, Simple, Safe, and Effective Guide-Pin : A Computerized Tomography Analysis

  • Hyun, Seung-Jae;Kim, Yongjung J.;Rhim, Seung-Chul;Cheh, Gene;Cho, Samuel K.
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.1
    • /
    • pp.9-13
    • /
    • 2015
  • Objective : To improve pedicle screw placement accuracy with minimal radiation and low cost, we developed specially designed K-wire with a marker. To evaluate the accuracy of thoracolumbar pedicle screws placed using the novel guide-pin and portable X-rays. Methods : Observational cohort study with computerized tomography (CT) analysis of in vivo and in vitro pedicle screw placement. Postoperative CT scans of 183 titanium pedicle screws (85 lumbar and 98 thoracic from T1 to L5) placed into 2 cadavers and 18 patients were assessed. A specially designed guide-pin with a marker was inserted into the pedicle to identify the correct starting point (2 mm lateral to the center of the pedicle) and aiming point (center of the pedicle isthmus) in posteroanterior and lateral X-rays. After radiographically confirming the exact starting and aiming points desired, a gearshift was inserted into the pedicle from the starting point into the vertebral body through the center of pedicle isthmus. Results : Ninety-nine percent (181/183) of screws were contained within the pedicle (total 183 pedicle screws : 98 thoracic pedicle screws and 85 lumbar screws). Only two of 183 (1.0%) thoracic pedicle screws demonstrated breach (1 lateral in a patient and 1 medial in a cadaver specimen). None of the pedicle breaches were associated with neurologic or other clinical sequelae. Conclusion : A simple, specially designed guide-pin with portable X-rays can provide correct starting and aiming points and allows for accurate pedicle screw placement without preoperative CT scan and intraoperative fluoroscopic assistance.

A Morphometric Study on Cadaveric Aortic Arch and Its Major Branches in 25 Korean Adults : The Perspective of Endovascular Surgery

  • Shin, Il-Young;Chung, Yong-Gu;Shin, Won-Han;Im, Soo-Bin;Hwang, Sun-Chul;Kim, Bum-Tae
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.2
    • /
    • pp.78-83
    • /
    • 2008
  • Objective : To understand the anatomic characteristics of the aortic arch (AA) and its major branches to build a foundation toward performing endovascular surgery safely. Methods : A total of 25 formalin fixed Korean adult cadavers were used. The authors investigated : anatomical variations of the AA and its major branches; curvature of the AA; distance from the mid-vertebrae line to the origin of the major branches; distances from the origin of the major branches of AA to the origin of its distal branches; and the angle of the three major branches, the brachiocephalic trunk (BCT), the left common carotid artery (LCCA) and the left subclavian artery (LSCA) arising from AA. Results : The three major branches directly originated from AA in 21 (84%) of the cadavers. In two (8%) of remaining four cadavers. orifice of LCCA was slightly above the stem of BCT. In remaining two (8%) cadavers, the left vertebral artery (LVA) was directly originated from AA. Average angle of AA curvature to the coronal plane was 62.2 degrees. BCT originated 0.92 mm on the right of the mid-vertebrae line. LCCA and LSCA originated from 12.3 mm and 22.8 mm on the left of the mid-vertebrae line. Mean distance from the origin of the BCT to the origin of the RCCA was 32.5 mm. Mean distance from the origin of the LSCA to the origin of the LVA was 33.8 mm. Average angles at which the major branches arise from the AA were 65.3, 46.9 and 63.8 degrees. Conclusion : This study may provides a basic anatomical information to catheterize AA and its branches for safely performing endovascular surgery.