154kV급 중간접속부내의 부분방전 진단을 위한 HFCT 적용 기준신호 측정연구 (Measurement of Basis Signal with HFCT for Diagnosing Partial Discharge in Middle Joint Box of 154kV Grade)

  • 이용성;김정윤;이정용;최용성;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.217-219
    • /
    • 2005
  • To detect partial discharge of 154kV joint box, we have made experiment by using the HFCT sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we test reliability on both injection of calibration signal in NJB and removal of low frequency. After that, we had analyzed frequencies by measuring signals in IJB with 300[m] distance from NJB. Also we had measured S/N ratio by using the indirected injection method of calibration signal in IJB. In this experiment, two measurement methods were difference of detection acquisition, but these had the equal frequency properties.

  • PDF

154kV급 중간접속부내의 부분방전 진단을 위한 HFCT 적용 기준신호 측정 (Measurement of Basis Signal with HFCT for Diagnosing Partial Discharge in Middle Joint Box of 154kV Grade)

  • 안종현;윤주호;최용성;박대희;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.75-78
    • /
    • 2007
  • To detect partial discharge of 154kV joint box, we have made experiment by using the HFCT sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we test reliability on both injection of calibration signal in NJB and removal of low frequency. After that, we had analyzed frequencies by measuring signals in IJB with 300[m] distance from NJB. Also we had measured S/N ratio by using the indirected injection method of calibration signal in IJB. In this experiment, two measurement methods were difference of detection acquisition, but these had the equal frequency properties.

  • PDF

Wind tunnel study of wake-induced aerodynamics of parallel stay-cables and power conductor cables in a yawed flow

  • Jafari, Mohammad;Sarkar, Partha P.
    • Wind and Structures
    • /
    • 제30권6호
    • /
    • pp.617-631
    • /
    • 2020
  • Wake-induced aerodynamics of yawed circular cylinders with smooth and grooved surfaces in a tandem arrangement was studied. This pair of cylinders represent sections of stay-cables with smooth surfaces and high-voltage power conductors with grooved surfaces that are vulnerable to flow-induced structural failure. The study provides some insight for a better understanding of wake-induced loads and galloping problem of bundled cables. All experiments in this study were conducted using a pair of stationary section models of circular cylinders in a wind tunnel subjected to uniform and smooth flow. The aerodynamic force coefficients and vortex-shedding frequency of the downstream model were extracted from the surface pressure distribution. For measurement, polished aluminum tubes were used as smooth cables; and hollow tubes with a helically grooved surface were used as power conductors. The aerodynamic properties of the downstream model were captured at wind speeds of about 6-23 m/s (Reynolds number of 5×104 to 2.67×105 for smooth cable and 2×104 to 1.01×105 for grooved cable) and yaw angles ranging from 0° to 45° while the upstream model was fixed at the various spacing between the two model cylinders. The results showed that the Strouhal number of yawed cable is less than the non-yawed case at a given Reynolds number, and its value is smaller than the Strouhal number of a single cable. Additionally, compared to the single smooth cable, it was observed that there was a reduction of drag coefficient of the downstream model, but no change in a drag coefficient of the downstream grooved case in the range of Reynolds number in this study.

열전압변환기를 이용한 고주파전압계의 교정과 측정불확도 (Uncertainty in the Course of Calibration of RF Multimeter using TVC)

  • 박정규;박석주;이환상;장경승;박명선
    • 한국전자파학회논문지
    • /
    • 제13권1호
    • /
    • pp.47-52
    • /
    • 2002
  • 1993년도 ISO에서 \"Guide to Expression of Uncertainty in Measurement\"를 발표함으로써 측정과학에 있어 측정결과의 오차분석 방법을 폐기하기로 사실상 선언하였다. 그리하여 측정의 소급성과 신뢰성을 확보한다는 전제 하에 오차의 개념을 버리고 측정시의 측정불확도를 분석하는 것이 측정과학에 있어서 세계적인 추세이다. 본 논문에서는 전달표준인 열 전압변환기를 사용하여 고주파전압계의 정밀 교정에서 불확도를 산출하기 위하여 수학적 모델을 설정하고 측정에 관계되는 모든 불확도 요인을 분석하였다. 케이블의 영향과 열전대감지기와 직류전압계의 상관관계, 직류소스, RF소스, 감쇠기, 반사계수와 DUT 등 측정에 있어서 관계되는 모든 불확도요인을 분석하여 확장불확도를 산출하였다.확도를 산출하였다.

전력케이블에서 개폐충격파를 이용한 부분방전 측정 (Partial Discharge Measurement in Power Cables using Switching Impulse Voltages)

  • 이전선;장은;구자윤;김정태;조연옥;김상준;송일근;김주용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.382-384
    • /
    • 1997
  • On-site partial discharge test by use of AC voltage has been considered not to be appropriate for the extruded power cable due to their large capacitance depending on their lengths. Therefore, it is proposed, in this work, to use switching impulse voltage of which the front time is set from 1ms to 10ms. This newly proposed method enables us to simulate the 1/4 period of power frequency at 60 Hz and to obtain similar effect of AC voltage test. Our tentative results show that 51 voltage is proved to be an alternative method, replacing AC voltage, by which partial discharge was well produced from the artificial defects integrated in 22.9kV distribution power cables.

  • PDF

Comparative Study on Conductivity and Moisture Content Using Polarization and Depolarization Current (PDC) Test for HV Insulation

  • Jamail, N.A.M.;Piah, M.A.M.;Muhamad, N.A.;Kamarudin, Q.E.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권1호
    • /
    • pp.7-11
    • /
    • 2014
  • The Polarization and Depolarization Current (PDC) measurement is an efficient and effective diagnostic technique based on time domain measurement, for evaluating the high voltage insulation condition. This paper presents a review and comparison results from several published papers on the application of the PDC method to finding the conductivity and moisture content of various types of insulators. For solid insulation, the study was focused on cable insulation, electric machine stator insulation, and paper insulator in transformer insulation with different conditions. For liquid insulation, the review and comparison was done on biodegradable and mineral transformer oils, with fresh oil condition, and aged condition. The results from previous researchers tests were complied, analyzed and discussed, to evaluate the application of the PDC method to monitor the conductivity and moisture of HV equipment insulation systems. From the review results, the PDC technique successfully gives an indication of the conductivity and moisture level of high voltage insulation.

초고압 케이블용 가교폴리에틸렌의 체적고유저항특성 (Volume Resistivity Properties of Cross-linked Polyethylene for Ultra-high Voltage Cable)

  • 정준;김원종;이관우;이수원;박하용;김왕곤;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.455-458
    • /
    • 2002
  • In this paper, the physical and volume resistivity properties of cross-linked polyethylene (XLPE) for ultra-high voltage investigated due to temperature dependence, and the measurement of volume resistivity used to highmegohm meter is measured from 1 to 30 minutes when the each applied voltage, for example, DC 100[V], 250[V], 500[V] and 1000[V] is applied, according to the step voltage application method. From FT-IR spectrum as an analysis of physical properties, a strong absorption in wavenumbers 700 to 730[$cm^{-1}$ /], 1456[$cm^{-1}$ /] and 2700 to 3000 [$cm^{-1}$ /] observed by the methyl groups(CH$_2$). From the analysis of DSC, the crystalline melting points of the specimen observed in the temperature 60[$^{\circ}C$] and 106.58[$^{\circ}C$].

  • PDF

전력케이블에서 발생하는 전기트리의 Chaos/Fractal 해석 (The Analysis on the Chaos/Fractal of Electrical Tree Generated at Power Cable)

  • 임장섭;김진국;김현종;이진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집
    • /
    • pp.19-22
    • /
    • 2004
  • Growth of Electrical Tree Under 50Hz~60Hz high electric stress has been studied on the Occurrence of a Pattern, to the Progression Speed at Y axis of electrical Tree. CCD Images of evolving tree structures could be obtained in both systems. Electrical Treeing was found to occur reproducibly, but in a markedly different manner in the two morphologimlly different but chemically identical materials. For the measurement of Electrical Tree, a visual measurement with an optical microscope has been used to explain breakdown mechanism in High-voltage systems.

  • PDF

원전 저압케이블 열화도 평가를 위한 초음파 음속계측에 관한 연구 (A Study on the Measurement of Ultrasound Velocity to Evaluate Degradation of Low Voltage Cables for Nuclear Power Plants)

  • 김경조;강석철;구철수;김진호;박재석;주금종;박치승
    • 비파괴검사학회지
    • /
    • 제24권4호
    • /
    • pp.325-330
    • /
    • 2004
  • 원자력발전소에는 여러 종류의 케이블이 전력공급, 감시 및 제어신호의 전달을 위해 열악한 환경하에서 이용되고 있다. 발전소의 안전한 운전을 위해서 이 케이블이 어느 정도 열화 되었는지 확인할 필요가 있다. 특히, 원자력발전소의 수명 연장과 더불어 저압 케이블을 장기간 사용함에 따라서 저압케이블의 열화를 평가하기 위한 방법이 필요하게 되었다 저압케이블의 열화를 측정하는 파라미터로는 주변 온도, 절연재질의 경도, 파단시 연신률(EAB, Elongation At Breaking Point) 등이 있다. 그러나, 온도나 경도를 계측하는 검사는 정량적인 판단기준의 설정이 곤란하고 진단의 정밀도가 낮으며, 부분적으로 샘플링하는 방법은 샘플링되는 케이블에 연결된 부하를 정전시켜야 하고 장소와 시간적인 제약이 있으며, 전기적 측정법은 노화 초기부터 중기까지의 열화정도를 확인하기 어렵다. 본 연구에서는 재료의 열화에 따라서 초음파의 음속이 변화한다는 이론적인 배경(1,2)을 바탕으로 저압 케이블 재료의 열화에 따른 초음파의 음속을 측정하였다. 이를 위해, 원자력발전소에서 사용되는 저압케이블을 가속 열화시켰으며, 저압케이블의 피복재에서 초음파의 음속을 측정할 수 있는 장비를 개발하여, 초음파의 음속측정 후 인장시험을 통해 파단시 연신률을 측정하였다. 파단시 연신률이 증가함에 따라서 음속이 선형적으로 감소하였으며, 초음파의 음속은 열화의 정량적 평가 파라미터로서의 사용 가능성을 확인할 수 있었다.

박 센서 배열에 따른 154kV XLPE 케이블의 부분방전 검출 특성 연구 (Partial Discharge Quality Measurement improvement of XLPE Cable of 154kV by new method of FSA)

  • 신동훈;양종석;;임종천;황두현;박노준;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.158-159
    • /
    • 2006
  • The system measuring the Partial discharge(PD) is very essential to investigate the hazard defects in the insulation systems of the high voltage engineering. We included two parts in this discussion; The proposed method of Foil Sensor Array and the normally used method m the practice. Firstly, it will be shown the improved sensitivity of our proposed FSA sensor compare with the existing normal foil sensor. And then, the linearity of detecting sensitivities of various kinds of FSA sensors such as $2{\times}2$, $2{\times}4$, $3{\times}3$ etc. using in our experiments, was shown. From the obtained results, we can see that FSA sensor is more sensitivity than normal foil sensor and the linear increment property of FSA sensitivities.

  • PDF