• Title/Summary/Keyword: cable robot

Search Result 60, Processing Time 0.023 seconds

Study for Operation Method of Underwater Cable and Pipeline Burying ROV Trencher using Barge and Its Application in Real Construction

  • Kim, Min-Gyu;Kang, Hyungjoo;Lee, Mun-Jik;Cho, Gun Rae;Li, Ji-Hong;Yoon, Tae-Sagm;Ju, Jaeheung;Kwak, Han-Wan
    • Journal of Ocean Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.361-370
    • /
    • 2020
  • We developed a heavy-duty work class ROV trencher named URI-T (Underwater robot it's trencher) that can conduct burial and maintenance tasks for underwater cables and small diameter pipelines. It requires various supporting systems, including a dynamic positioning (DP) vessel, launch and recovery system (LARS), A-frame, and winch in order to perform burial tasks because of its dimensions (6.5 m × 5.0 m × 4.5 m, 20 t) and the tough working environment. However, operating a DP vessel has disadvantages as it is expensive to rent and operate and it is difficult to adjust the working schedule for some domestic coast construction cases. In this paper, we propose a method using a barge instead of a DP vessel to avoid the above disadvantages. Although burying the cable and pipeline using a barge has lower working efficiency than a DP vessel, it can save construction expenses and does not require a large crew. The proposed method was applied over two months at the construction of the water supply in Yokji-do, and the results were verified.

A Two-Dimensional Position Sensor Using Cable Extension Transducers (케이블센서를 이용한 2차원 위치측정 시스템)

  • Hong, Dae-Hie
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.9
    • /
    • pp.159-165
    • /
    • 1999
  • Based on the cable-extension transducers, a new technique for two dimensional position measurement is developed in this paper. This new technique includes the use of two such transducers and the planar position is determined through triangulation. This paper also presents uncertainty analysis results for establishing sensor design specifications. An actual prototyped sensor system is built and its accuracy is verified through h\both experiments with coordinate measurement machines and its application to the real-time control of a high load wheeled mobile robot. This new type of position sensor can be easily used in a wide variety of automation applications in industry for two dimensional position measurements with high accuracy over a relatively large range, and it is both cast effective and robust against hostile environments.

  • PDF

Study for the Indirect Measuring Method of Operational Force in Surgical Robot Instrument (복강경 수술용 로봇 인스트루먼트의 간접적 작동력 측정법에 관한 연구)

  • Kim, Chi-Yen;Lee, Min-Cheol;Lee, Tae-Kyung;Choi, Seung-Wook;Park, Min-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.9
    • /
    • pp.840-845
    • /
    • 2010
  • This paper proposes the method indirectly measuring the operating force of the end-effect tip of surgical robot instrument which conducts the surgical operation in the body on behalf of the surgeon's hand. Due to the size and safety obligation to the surgical robot instrument, it is difficult to measure the operation force of its tip like grasping force. However the instrument is driven by cable-pulley torque transmission mechanism and when some force is occurred at the tip, then the reaction force appears on the cable as additional tension. Based on this phenomenon, this paper proposes a method to estimate the operating force from measuring reaction force against the driving motor by using a loadcell. And it induces mathematical equation to calculate the force from loadcell by approaching the modulus of elasticity to high order polynomial. And this paper proves the validity of proposed mechanism by experimental test.

Design of a Novel 1 DOF Hand Rehabilitation Robot for Activities of Daily Living (ADL) Training of Stroke Patients (뇌졸중 환자의 일상생활 동작 훈련을 위한 1자유도 손 재활 로봇 설계)

  • Gu, Gwang-Min;Chang, Pyung-Hun;Sohn, Min-Kyun;Shin, Ji-Hyeon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.9
    • /
    • pp.833-839
    • /
    • 2010
  • In this paper, a novel 1 DOF hand rehabilitation robot is proposed in consideration of ADL training for stroke patients. To perform several ADL trainings, the proposed robot can move the thumb part and the part of 4 fingers simultaneously and realize the full ROM (Range of Motion) in grasp. Based on these characteristics, the proposed robot realizes several types of grasp such as cylindrical grasp, lateral grasp, and pinch grasp by using a passive revolute joint that can change the thumb movement direction. The movement of the thumb is driven by a cable mechanism and the part of 4 fingers is moved by a four-bar linkage mechanism.

Evaluation of a Possibility of Estimation of Reaction Force of Surgical Robot Instrument using Sliding Perturbation Observer (슬라이딩 섭동 관측기를 이용한 수술용 로봇 인스트루먼트의 반력 추정 가능성 평가)

  • Yoon, Sung-Min;Lee, Min-Cheol;Kim, Chi-Yen;Kang, Byeong-Ho
    • The Journal of Korea Robotics Society
    • /
    • v.7 no.1
    • /
    • pp.20-28
    • /
    • 2012
  • In spite of the difficulties and uncertain characteristic of cable driven method, surgical robot instrument has adopted it as driving mechanism for various reasons. To overcome the problem of cable system, previous research applied SMCSPO (sliding mode control with sliding perturbation observer) algorithm as robust controller to control the instrument and found that the value of SPO (sliding perturbation observer) followed force disturbance, reaction force loaded on the tip very similarly. Thus, this paper confirms that the perturbation observer is sufficient estimator which finds out the mount of loaded force on the surgical robot instrument. To prove the proposition, simulation using the similar model with an actual instrument and experimental evaluation are performed. The results show that it is possible to substitute SPO for sensors to measure the reaction force. This estimated reaction force will be used to realize haptic function by sending the reaction force to a master device for a surgeon. The results will contribute to create surgical benefit such as shortening the practice time of a surgeon and giving haptic information to surgeon by using it as haptic signal to protect an organ by making force boundary.

Development of the Resource Investigation Emulating Cable Car Type Robot System (자원탐사의 최적화 및 자동화를 위한 케이블카형 로봇 시스템의 개발)

  • Yu, Son-Cheol;Pyo, Ju-Hyun;Jung, Hyun-Key;Yoon, Joong-Sun;Lee, Jung-Ik;Cho, Sung-Ho;Kim, Tae-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.38-44
    • /
    • 2011
  • Recently, the resource investigation has got much attention. The optimization of the resource investigation method and its automation are one of the most important keys for it. We propose the resource investigation emulating robot to overcome the conventional method; a numerical modeling. A nobel cable car robot system is developed. It minimizes the magnetic noise and comes true the gradient emulating of the field. This advanced system enables the optimization and automation of the resource investigation.

Heading Control of URI-T, an Underwater Cable Burying ROV: Theory and Sea Trial Verification (URI-T, 해저 케이블 매설용 ROV의 선수각 제어 및 실해역 검증)

  • Cho, Gun Rae;Kang, Hyungjoo;Lee, Mun-Jik;Li, Ji-Hong
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.178-188
    • /
    • 2019
  • When burying underwater cables using robots, heading control is one of the key functions for the robots to improve task efficiency. This paper addresses the heading control issue for URI-T, an ROV for underwater construction tasks, including the burial and maintenance of cables or small diameter pipelines. Through modeling and identifying the heading motion of URI-T, the dynamic characteristics and input limitation are analyzed. Based on the identification results, a PD type controller with appropriate input treatment is designed for the heading control of URI-T. The performance of the heading controller was verified in water tank experiments. The field applicability of the proposed controller was also evaluated through the sea trial of URI-T at the East Sea, with a water depth of 500 m.

Development of Biped Walking Robot with Stable Walking (안정적 보행을 갖는 이족 보행 로봇의 개발)

  • Seo, Chang-Jun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.3 no.2
    • /
    • pp.82-90
    • /
    • 2008
  • In this paper, we introduce a biped walking robot which can do static walking with 22 degree-of-freedoms. The developed biped walking robot is 480mm tall and 2500g, and is constructed by 22 RC servo motors. Before making an active algorithm, we generate the motions of robot with a motion simulator developed using C language. The two dimensional simulator is based on the inverse kinematics and D-H transform. The simulator implements various motions as we input the ankle's trajectory. Also the simulator is developed by applying the principle of inverted pendulum to acquisite the center of gravity. As we use this simulator, we can get the best appropriate angle of ankle or pelvic when the robot lifts up its one side leg during the walking. We implement the walking motions which is based on the data(angle) getting from both of simulators. The robot can be controlled by text shaped command through RF signal of wireless modem which is connected with laptop computer by serial cable.

  • PDF

Development of a Biped Walking Robot

  • Kim, Yong-Sung;Seo, Chang-Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2350-2355
    • /
    • 2005
  • In this paper, we introduce biped walking robot which can static walking with 22 degree-of-freedoms. The developed biped walking robot is 480mm tall and 2500g, and 22 RC servo motors are used to actuate. Before made an active algorithm, we generated the motions of robot with the motion simulator which developed using by C language. The two dimension simulator is Based on the inverse kinematics and D-H transform. The simulator implements various motions as inputted the ankle's trajectory. Also we developed a simulator which is applied the principle of inverted pendulum to acquires the center of gravity. As we use this simulator, we can get the best appropriate angle of ankle and pelvis when the robot lifts up its one side leg during the working. We implement the walking motions which is based on the data(angle) getting from both of simulators. The robot can be controlled by text shaped command through RF signal of wireless modem which connected with laptop computer by serial cable.

  • PDF