• 제목/요약/키워드: cabinet structure

검색결과 43건 처리시간 0.022초

모델링 방법의 차이에 따른 원전계측캐비넷의 동특성 해석 결과 비교분석 (comparative Study of Analytical Modal Properties of Instrumentation Cabinet of Nuclear Power Plant)

  • 조양희
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall
    • /
    • pp.186-192
    • /
    • 1999
  • Safety-related equipments of nuclear power plant must be seismically qualified to demonstrate their ability to function as required during and/or after the earthquake, The seismic qualification is usually achieved through analysis and testing. Analysis method is preferably adopted for structurally simple equipments which are easy to be mathematically modeled. However even for relatively complex equipments analysis method is occasionally used for computing the input motion or supporting information for the component test followed. Electrical cabinet is a typical example for which analysis method is combinedly used with test to get modal properties of the enclosing cabinet structure. Usually the structural elements and doors of the cabinet are loosely interconnected with small-size bolts or spot welding. Therefore cabinet-type equipment usually has high and complex nonlinear properties which are not easily idealized by simple practical modeling techniques. in this paper with respect to a typical cabinet-type structure(instrumentation cabinet of nuclear power plant) a comparative study has been performed between three different state-of-the -art modeling techniques: lumped mass model frame model and FEM modal. Form the study results it has been found that modal properties of the cabinet-type structure in the elastic behavior range can be reasonably computed through any type of modeling techniques in the practice with slight modification of model properties to get better accuracy. However it needs additional modeling techniques to get reasonable results up to nonlinear range.

  • PDF

Grouping effect on the seismic response of cabinet facility considering primary-secondary structure interaction

  • Salman, Kashif;Tran, Thanh-Tuan;Kim, Dookie
    • Nuclear Engineering and Technology
    • /
    • 제52권6호
    • /
    • pp.1318-1326
    • /
    • 2020
  • Structural modification in the electrical cabinet is investigated by a proposed procedure that comprises of an experimental, analytical and numerical solution. This research emphasizes the linear dynamic analysis of the cabinet that is studied under the seismic excitation to demonstrate the real behavior of the cabinets in NPP. To this end, an actual electric cabinet is experimentally tested using an impact hammer test which reveals the fundamental parameters of the cabinet. The Frequency-domain decomposition (FDD) method is used to extract the dynamic properties of the cabinet from the experiment which is then used for numerical modeling. To validate the dynamic properties of the cabinet an analytical solution is suggested. The calibrated model is analyzed under the floor response obtained from the Connecticut nuclear power plant structure excited by Tabas 1978 (Mw 7.4) earthquake. Eventually, the grouping effect of the cabinets is proposed which represents the influence on the dynamic modification. This grouping of the cabinets is described more sophisticatedly by the theoretical understating, which results in a significant change in the seismic response. Considering the grouping effects will be helpful in the assessment of the real seismic behavior, design, and performance of cabinets.

산업용 건축물 내 자동제어반의 냉각효율 향상에 관한 연구 (A Study on the Enhancement of Cooling Efficiency for the Cabinet of Automatic Controller in the Interior of Industrial Building)

  • 김순호;박현정
    • 동력기계공학회지
    • /
    • 제17권6호
    • /
    • pp.79-87
    • /
    • 2013
  • The improvement of cooling efficiency for the cabinet of automatic controller is the most efficient method of it's application. Therefore, this study has been analyzed and investigated the improvement of cooling efficiency and reduction of energy for the cabinet of automatic controller, respectively. So this study was conducted to enhancement of cooling efficiency for the cabinet of automatic controller by making a structure which produces difference of air pressures in the entrance tube of external air. And the structure has capacity of the pyrogen source (PTC elements) to make temperature range from $145^{\circ}C$ to $155^{\circ}C$. Consequently, temperatures of the upper, the lower in the interior of the cabinet of automatic controller and the exhaust part were revealed $28.57^{\circ}C$, $23.38^{\circ}C$and $36.14^{\circ}C$(average temperature of the exhaust part in case of existing method : $45^{\circ}C$) in target test of this study, respectively. It was found that the cabinet of the automatic controller has better cooling ability than the cabinet of automatic controller by using an existing method.

Distributed plasticity approach for nonlinear analysis of nuclear power plant equipment: Experimental and numerical studies

  • Tran, Thanh-Tuan;Salman, Kashif;Kim, Dookie
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.3100-3111
    • /
    • 2021
  • Numerical modeling for the safety-related equipment used in a nuclear power plant (i.e., cabinet facilities) plays an essential role in seismic risk assessment. A full finite element model is often time-consuming for nonlinear time history analysis due to its computational modeling complexity. Thus, this study aims to generate a simplified model that can capture the nonlinear behavior of the electrical cabinet. Accordingly, the distributed plasticity approach was utilized to examine the stiffness-degradation effect caused by the local buckling of the structure. The inherent dynamic characteristics of the numerical model were validated against the experimental test. The outcomes indicate that the proposed model can adequately represent the significant behavior of the structure, and it is preferred in practice to perform the nonlinear analysis of the cabinet. Further investigations were carried out to evaluate the seismic behavior of the cabinet under the influence of the constitutive law of material models. Three available models in OpenSees (i.e., linear, bilinear, and Giuffre-Menegotto-Pinto (GMP) model) were considered to provide an enhanced understating of the seismic responses of the cabinet. It was found that the material nonlinearity, which is the function of its smoothness, is the most effective parameter for the structural analysis of the cabinet. Also, it showed that implementing nonlinear models reduces the seismic response of the cabinet considerably in comparison with the linear model.

군용 차량 탑재 캐비닛 구조물의 구조건전성 분석 (Analysis of the Structural Robustness of Cabinet Structure Equipped with Military Vehicles)

  • 손동훈;강광희;최지호;박도훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.273-276
    • /
    • 2014
  • The development of a vehicle-mounted radar to detect the location of enemy artillery is mainly mounted during operation to the mobility of the equipment and efficiency of utilization range. It is equipped with an electronic device responsible for the operation of the radar system. Electronic equipments is performed functionality imparted without an error-specific in spite of disturbances such as vibration / shock caused by vehicle movement. Therefore, vibration / shock resistance is held to prevent damaging from vibration / shock generated from the outside environment during operation. In addition, a standardized and specified cabinet structure equipped with electronic equipment is placed in shelter to ensure additional safety for vibration / shock. In this study, it is evaluated by analytical method with vibration / shock resistance of the cabinet structures for ensuring structural safety factor is applied to the aluminum. It is verified the reliability of the structure and structural dynamics to verify by calculated natural frequencies adding the weight of the cabinet structure and the structural displacement and stress results confirmed with vibration / shock caused by the vehicle movement.

  • PDF

원자력발전소 보호시스템 캐비넷의 내진검증 (Seismic Qualification of Plant Protection System Cabinet for Nuclear Power Plant)

  • 정명조;박근배;황원걸
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.148-155
    • /
    • 1992
  • A method to verify seismic qualification of the plant protection system cabinet for a nuclear power plant is presented. A finite element model of the cabinet is developed and correlated to the dynamic properties observed during in-situ vibration test of the actual structure. The results of the modal analysis provide insight into the fundamental dynamic properties of the structure. Techniques for verifying structural integrity and operability are exemplified by summarizing response spectrum and time history analyses of the structure.

  • PDF

칼리가리 박사의 밀실과 해체주의 건축의 표현주의 특성 비교 (Comparison of "The Cabinet of Dr. Caligari" and Deconstructive Architecture in the Expressionist Characteristics)

  • 최효식
    • 한국실내디자인학회논문집
    • /
    • 제25권1호
    • /
    • pp.35-46
    • /
    • 2016
  • The purpose of this study was to identify the characteristics of expressionism in the space of deconstructive architecture by comparing the spaces of "The Cabinet of Dr. Caligari" video with the expressionist characteristics of film narrative structure and expressionist architecture and making an expansion based on the results. The findings were as follows: first, the "The Cabinet of Dr. Caligari" is divided into two set spaces: one has the perspective representation distorted in the viewpoint of a mad person applied to it, and the other reflects the viewpoint of a normal person from medieval paintings with no perspective. Second, the expressionist buildings did not reflect the expressionist characteristics in the interior spaces as fully as in the exterior ones. Third, the incomplete combination of Signifiant and $Signifi{\acute{e}}$, which were the theoretical basis of deconstructive architecture, showed a tendency of binary opposition like the double narrative structure of "The Cabinet of Dr. Caligari." Fourth, deconstructive architecture seems to embody the exterior form and interior space of "The Cabinet of Dr. Caligari" and its set spaces in the phenomenal aspect but exhibits its limitations with the realization of dynamics, one of the characteristics of expressionism. Finally, the Seattle Public Library presents the best embodiment of expressionist characteristics found in the set spaces of "The Cabinet of Dr. Caligari" while seeking after the combination of horizontal and vertical paths of action through the spiral ramps and inclined slabs.

원자력 발전소 캐비닛구조물의 내진보강 (Seismic Retrofitting of Cabinet Structures in Nuclear Power Plant)

  • 이계희;김재민;김상윤
    • 한국지진공학회논문집
    • /
    • 제7권4호
    • /
    • pp.31-37
    • /
    • 2003
  • 본 논문에서는 오래된 원자력발전소의 내진검증과 관련한 USI A-46 문제의 해결에 사용될 수 있는 캐비닛의 내진보강방안에 대해 연구하였다. 캐비닛 구조물의 동적거동특성을 파악하기 위하여 3종류의 모델링을 수행하였고 그 결과를 비교하였다. 또한 ICRS(In Cabinet Reponse Spectrum)의 저감을 위하여 1) 보강프레임, 2)감쇠기 설치, 3) 동조질량감쇠기 등 세 가지 내진보강방안에 대하여 구조물의 응답을 산정하였다. 해석결과, 가새보강 및 감쇠기를 설치하는 보강방법에서는 보강전의 구조물보다 큰 ICRS가 얻어지는 경우가 발생해 보강시 많은 주의가 요구된다. 동조질량감쇠기의 사용은 좋은 제진효과를 보였으나 실구조물과 정확한 진동특성을 반영한 모델의 작성이 중요한 것으로 판단되었다.

원자력발전소 보호시스템 캐비넷의 내진검증 (Seismic Qualification of Plant Protection System Cabinet for Nuclear Power Plant)

  • 정명조;황원걸
    • 전산구조공학
    • /
    • 제6권2호
    • /
    • pp.79-86
    • /
    • 1993
  • 원자력발전소중 안전과 관련된 구조물은 지진의 가능성에 대비하여 그의 구조적 안전성과 가용성이 검증되어야 한다. 본 논문은 원자력발전소 보호시스템 캐비넷을 예를 들어 그에 대한 내진검증 방법을 보였다 캐비넷의 유한요소모델을 작성하여 동특성을 구하였고 그 모우드값을 입력지진스펙트럼과 비교한 결과 구조물의 1차 모우드가 입력 스펙트럼의 peak와 일치함으로써 설계변경의 필요성이 대두되었다. 이 peak값을 피하기 위하여 캐비넷의 구조를 변경하였고 변경된 구조물에 대하여 응답스펙트럼해석과 시간이력해석을 수행하여 구조적 건전성과 가용성을 보임으로써 설계변경된 캐비넷의 내진검증을 확인하였다.

  • PDF

유전자알고리즘을 이용한 캐비닛 구조의 최적감쇠보강 (The optimum damper retrofit of cabinet structures by genetic)

  • 이계희;최익창;하동호
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.379-386
    • /
    • 2004
  • The optimal seismic retrofitting of NPP(Nuclear Power Plant) cabinet structures that contained class 1 relays were studies in this paper. During earthquake event, the failure modes of relays are not appeared in form of structural failure, but are appeared in form of contact chatter of relay. Therefore, the retrofitting of cabinet has to be aimed to the reducing of the structural response, such as acceleration. In this study, the optimal characteristic values of dampers were searched by μ-GA (micro-Genetic Algorithm) scheme for several installation patterns. To keep accuracy and efficiency of analysis, the structural models of cabinet were considered as a frame structure. The responses of structure were obtained in form of acceleration response spectra derived from the results of nonlinear time history analysis including damping nonlinearity. The fitness function of the optimum procedure was constructed based on the ratio of maximum spectral value and target GERS (General Equipment Ruggedness Spectra). The results show the good improvements of fitness fur adequate retrofitting pattern. Especially, the improvements of fitness were remarkable when the damping exponents are proper.

  • PDF