• 제목/요약/키워드: cabin air quality

검색결과 50건 처리시간 0.029초

항공기 내 실내공기질에 관한 고찰: 이동의 증가와 건강에 미치는 영향 및 블리드에어의 영향 (Indoor Air Quality in Aircraft: The Impact of Increased Mobility and Health Effects and the Influence of Bleed Air)

  • 함승헌
    • 한국환경보건학회지
    • /
    • 제49권3호
    • /
    • pp.129-133
    • /
    • 2023
  • Background: With the rise in global mobility, aircraft indoor air quality has become a significant public health concern. This study focuses on the health implications of increased travel and bleed air-air drawn from aircraft engines for cabin pressurization and air conditioning. Objectives: This research aims to review the potential health effects related to exposure to aircraft cabin air, particularly the effects of bleed air during fume events. Methods: We conducted a literature review of existing studies on aircraft cabin air quality. We focused on both the immediate and health effects of exposure to cabin air, particularly those related to bleed air contaminants. Results: The review found a possible link between exposure to aircraft cabin air and certain health issues, especially in cabin crew and frequent flyers. There was an increased incidence of respiratory and neurological symptoms related to bleed air exposure. However, the cumulative health effects of frequent air travel remain inconclusive due to limited data. Conclusions: This study highlights the need for improving air quality in aircraft to protect public health. While further research is needed to understand the cumulative effects of frequent air travel, the reduction of exposure to bleed air contaminants should be a priority. These findings underline the need for regulatory changes and technological improvements in aircraft cabin air quality.

고속열차 객실의 휘발성유기화합물 및 부유미생물 분석 연구 (Study on the volatile organic compounds and suspended microorganism in a high-speed train passenger cabin)

  • 조영민;정우성;박덕신;권순박;박은영;정미영;목진용;이종범
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1045-1050
    • /
    • 2008
  • The public interest on the indoor air quality of a high-speed train passenger cabin is drastically increasing due to the sealing of cabin. In this study, the concentration of volatile organic compounds and suspended microorganism in the high-speed train passenger cabin was investigated. There have been many studies on the indoor air quality of the high-speed passenger cabin, but the study on the indoor air quality without boarding of passengers were hardly carried out. As a result, it was very difficult to identify the exact source of air pollutants in the cabin. In this study, the indoor air quality of passenger cabin without any passengers was investigated so that the contribution of passengers as the source of various pollutants could be estimated.

  • PDF

자동차 캐빈 공기질 제어를 위한 적정 입자청정횟수 평가 (Evaluation of proper particle cleaned air delivery per hour (PCH) for controlling indoor air quality in passenger car cabin)

  • 노광철;김태욱;김상우;황청하;한방우
    • 한국입자에어로졸학회지
    • /
    • 제20권2호
    • /
    • pp.47-56
    • /
    • 2024
  • In this study, an empirical study was conducted to investigate the clean air delivery rate (CADR) and the proper particle cleaned air delivery per hour (PCH) of the air cleaning device installed in passenger car cabin. Changes in internal particle concentration were measured in the cabins of the pick-up type engine-driven car and the electric vehicle depending on cabin air filters, ventilation modes, and blower settings. In the tested cars, PM2.5 collection efficiency of the HEPA filter was higher than that of the genuine filter. The PM2.5 collection efficiency of each cabin air filter was measured to be similar regardless of the blower setting of the tested cars. This means that the higher the blower setting, the higher the CADR and the PCH. The infiltration rate varies depending on the air tightness of the car. The cabin was more contaminated with particles under driving. From the CADRs measured inside the passenger car cabin, the recirculation mode of HVAC system is a more effective for managing ultrafine particles than the fresh air mode. From a few assumptions, the proper PCH was derived about 0.8 times/min (48 times/h). From this result and several experiments, the proper operation setting of air cleaning device installed inside cars can be found out to control indoor air quality. Also, an appropriate operation settings of HVAC system can be found with considering cooling and heating conditions for thermal comfort in passenger car cabin.

지하철 전동차 객실 내부 공기질 조사 연구 (Research Study on Indoor Air Quality (IAQ) inside of the Subway Cabin in Seoul Metropolitan City)

  • 이경빈;김진식;배성준;김신도
    • 한국대기환경학회지
    • /
    • 제30권2호
    • /
    • pp.175-187
    • /
    • 2014
  • The subways play an important part in serious traffic problems. Almost seven million citizens a day are using subways as a means of traffic communication in the Seoul metropolitan city in 2012. However, the subway system is a semi-closed environment, so many serious problems occurred in subway stations and injured passengers' health. Platform screen doors (PSD) are expected to prevent negligent accident such as injury or death from falling and improve the air quality of the subway station. Installation of PSD at stations in Seoul metropolitan subway had been completed in December 2009. Consequently, the underground transportation system became a closed environment, so the air quality has improved the platforms, but it has deteriorated in the tunnels. Especially, the subway cabin has many doors, and the doors are frequently opened and closed. For this reason, the effect of door opening on subway cabin, dust flow inside the subway cabin. In this process, the maintenance work may influence the health of people who work underground, as well as that of subway users (passengers). In this study, we measured air quality inside and outside of the subway cabin line 2 in Seoul, Korea. This study focused on the investigation of Indoor Air Quality (IAQ) and measurement target pollutants are PM10, CO, $CO_2$, $NO_2$, $O_3$. It was found that levels of PM10, $CO_2$, and $NO_2$ inside subway cabin line 2 exceeded the Korea IAQ standard. Concentrations of PM10, $CO_2$, and $NO_2$ inside of the cabin are higher than outside of the cabin (Indoor Outdoor ratio is higher than 1.). Concentrations of CO, $O_3$ inside of the cabin are lower than outside of the cabin (Indoor Outdoor ratio is lower than 1.). There is a high correlation between $CO_2$ and passengers inside of the cabin and PM10 is only the weakest correlation with passengers. Therefore, it is important to find out the emission source of $NO_2$. The results of this study will be useful as fundamental data to study indoor air quality of a subway cabin.

고객 충성도 및 항공사 이미지 형성에 기내 서비스품질이 미치는 영향 (The Effect of the Cabin Service Quality on Customer Loyalty and Airline Image)

  • 왕수명;박혜윤
    • 한국항공운항학회지
    • /
    • 제24권2호
    • /
    • pp.47-58
    • /
    • 2016
  • The cabin service quality expected by customers during the air travel can be the top priority to choose an airline. Customers' perception about cabin service quality evaluation are important for developing differentiated cabin service strategies of airlines, so this study aims to analyze the effect of the cabin service quality on airline image and customer loyalty. For achieving this purpose, literature study and empirical study on cabin service, customer loyalty and airline image were performed together. As a results of research, a high level of the cabin service quality provided by airlines significantly influenced positive images of airlines and customer loyalty. And customers' positive image towards airlines practically had a substantial influence on the improvement of customer loyalty. These study results would help in creating positive images of airlines and securing customer loyalty by developing differentiated and improved cabin service quality strategies of each airline in the limitless competition of the aviation service industry.

외기 미세먼지와 탑승객수에 따른 객실 PM10 농도변화 연구 (Study on PM10 levels by the concentration of outdoor aerosols and the number of passengers in railway cabin)

  • 박은영;박덕신;권순박;조영민;김세영;정미영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1816-1820
    • /
    • 2008
  • Indoor air quality in public transportation such as railway, subway and bus is hard to control because of spatial restrict and variation of passenger's number. On January 2007, The Ministry of Environment announced "the guideline of indoor air quality in public transportation" for the concentration managements of particulate matter and carbon dioxide. In this study, we measured the PM10 concentration inside the Mugunghwa-ho passenger cabin and outdoor air and counted passengers. By the statistical analysis using SigmaPlot 2001 and SPSS 13.0, we found that indoor PM10 concentration is significantly affected by outdoor air. It is suggested that the air quality of inflow to the passenger cabin for air exchange must be controlled to support the indoor environment comfortably.

  • PDF

철도차량에서의 공기질 현황 및 PM10 오염원 분석 (Air Quality and PM10 Source Analysis on the Railway Vehicles)

  • 박덕신;김동술;조영민;권순박;박은영
    • 한국대기환경학회지
    • /
    • 제23권3호
    • /
    • pp.311-321
    • /
    • 2007
  • Nowadays, concerns have much more growing regarding indoor air quality (IAQ) on the public transportation including railway vehicles. Last year Korea Ministry of Environment (ME) set new guideline for public transportation. In this study several factors were analyzed which may affect comfortableness of railway passenger cabin, and we monitored IAQ parameters (PM10, CO, $CO_2$, VOCs, temperature and humidity) to investigate the present pollution in passenger cabin. In general, the railway air quality was satisfactory. The PM10 and $CO_2$ level on all passenger cabin were below the new guideline level 1 for PM10 $(200{\mu}g/m^3)\;and\;CO_2(2,000ppm)$. Clustering method was carried out to classify the air polluting pattern of the cabin. As a result, the pollutants could be classified to 4 clusters and the origin of pollution is soil, diesel exhaust gas, abrasion of rail and plume.

도시철도 객실 공기정화장치(SCAP)의 운행차량 효율평가 (Efficiency Evaluation of Operating Railroad with Subway Cabin Air Purifier)

  • 권순박;박덕신;조영민;김종범;조관현;남궁석;이주열;김태성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1303-1308
    • /
    • 2011
  • In the modern society various types of transportation mode are utilized, among them the subway system is the one of the main transportation mode which more than 7.21 million people ride a day. Because of interests on the indoor air quality (IAQ) of underground public facilities, concerns on IAQ of subway system by many people are increasing. There are several approach to improve IAQ of subway station, such as installing platform screen door (PSD), frequent tunnel washing-out, and etc, however there has not been any attempt to improve IAQ of subway cabin inside. Most technologies for removing airborne particulate matters are known to be difficult to adopt on the subway cabin since the problem of maintenance cost. Therefore, the ultimate object of this study is a practical development of cabin air cleaning system which can reduce the concentration of airborne particles and harmful gases at the same time. The subway cabin air purifier (SCAP) was developed for removing particulate matters and gases pollutants inside a cabin. The whole system was designed and the roll-filter device was manufactured based on numerical prediction results. It is expected that SCAP could reduce indoor air pollutants in the subway cabin practically and it can be applied to other part of transportation vehicles.

  • PDF

KTX 객실의 IAQ 관리 기초 인자 분석 (Analysis of basic IAQ management factors in KTX passenger cabin)

  • 조영민;박덕신;박병현;박은영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.1153-1158
    • /
    • 2005
  • The passenger cabin of train is generally insulated from exterior environment to ensure the safety of passengers and to enhance the heating and cooling efficiency. Therefore, the IAQ management of passenger cabin is very important in aspect of amenity and health of passengers. In this study, we measured some IAQ factors influencing on the indoor air quality of passenger cabin. The measurement was carried out to investigate the PM-10, PM-2.5, PM-1.0, temperature, relative humidity, carbon monoxide, carbon dioxide leves of KTX. The results showed that the air quality of the cabin was largely satisfactory, but carbon dioxide level was relatively higher. The control of carbon dioxide levels need the extensive research in the future.

  • PDF

도시철도 객실 공기질 평가모델 개발 (Development of Air Quality Assessment Model for Subway Cabin)

  • 권순박;조영민;박덕신;김세영;박재형;조관현;유건종;김정수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.157-160
    • /
    • 2010
  • Management of indoor air quality of underground subway station is an important issue since the limited natural ventilation, limited sunshine incoming, and highly moistured atmosphere. The improvement in IAQ of platform is expected because most stations were installed with platform screen door currently, however, the poor air quality in tunnel might be affecting subway cabin indoor. In this study, we developed the air quality assessment model based on computational fluid dynamics. The geometry of air ventilation unit, seat, LCD monitors, and passengers were modeled using commercial software (Design Modeler) and fluid pattern and pollutants trajectories were analyzed by using CFX. We predicted the thermal comfort by predicted mean vote (PMV), distribution of CO2 and PM10 concentration. It is expected that this model can be used for the performance test of air cleaners which are under development.

  • PDF