• Title/Summary/Keyword: cANOVA

Search Result 1,159, Processing Time 0.022 seconds

An empirical study of Chinese consumers' lifestyle by country of origin effect of mobile phone (중국소비자 조사에서 휴대폰의 원산국 효과에 따른 라이프스타일 실증 연구)

  • Kim, Seong-Ju
    • Journal of the Korean Data and Information Science Society
    • /
    • v.27 no.6
    • /
    • pp.1565-1571
    • /
    • 2016
  • This paper is an empirical study of chinese consumers' lifestyle by country of origin effect of mobile phone. The data we analyze in this paper was collected and studied in Kim et al. (2006, 2007). We classify the respondents into the four groups according to the responses of country of origin effect of mobile phone. The four groups are group K (preference in made in Korea), group J (preference in made in Japan), group U (preference in made in USA), and group C (preference in made in China). One-way ANOVA and stepwise discriminant analysis are applied to classify the training sample which consists of 89 lifestyle variables and two personnel information. It is observed that group K is more open-minded, out front, aggressive, and self-assertive compared to group C.

The EFFECTS OF VARIOUS INSTRUMENTATION TECHNIQUES IN CURVED CANALS OF RESIN BLOCKS (만곡근관에서 수동식 기구와 엔진 구동형 기구의 근관성형 효과에 대한 비교 연구)

  • Jung, Il-Young;Yoon, Tai-Cheol;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.648-658
    • /
    • 1997
  • The purpose of this study was to compare the effects of various techniques on the quality and quantity of instrumentation in curved canals. Instrumentation time was evaluated too. Forty eight canals of resin blocks($35^{\circ}$) were divided into three groups and filed. In group A, 16 blocks were instrumented using a step-back technique with stainless steel(SS) K-file(Mani, Matsutani Seisakusho Co.,Japan). In group B, canals were prepared with SS K-files using the Endo-Angle (Nakanishi Dental MFG.CO.,LTD.,Japan). Group C was prepared using N i-Ti engine-driven instruments (Quantec Series $2000^{TM}$ system). Group A and B were filed from # 5 to # 25 at the apex followed by a 1 mm stepback technique, and the coronal half of the canals were flared with Gates Glidden burs(#2,3,4). Group C was instrumented from # 1 to # 8. After the instrumentation time was measured, canals were filled with India ink, and photographed, which to magnify the canal images 8 times. Using these photographs the apical portions were evaluated And scored from 1 to 4 according to the severity of ledging and zipping. On the same photographs, the area of the coronal two thirds of the canals were measured using a personal computer with the computer program Brain and Digitizer (SummaSketch III). The following results were obtained. 1. Instrumentation time was significantly shorter for group C, as opposed to group A and B(ANOVA, P<0.05). 2. The qualitative evaluation of the apical portions of the canals showed no significant difference between the groups(Kruscal-Wallis, p>0.05). 3. The area removed by group C was significantly smaller than group A and B(ANOVA, P<0.05).

  • PDF

Pharmacokinetics of Two Cyclosporine Formulations Using FPIA and HPLC Assay in Volunterrs

  • Kwon, Kwang-Il;Kim, Moo-Heon;Park, Jong-Woo;Lee, Chang-Hyun
    • Archives of Pharmacal Research
    • /
    • v.18 no.6
    • /
    • pp.385-390
    • /
    • 1995
  • The analytical methods for the analysis of cyclosporine (CsA), a fluorescence polarization immunoassay (FPIA) and HPLC method, were compared in a pharmacokinetic study of two CsA soft capsule formultaions ($Sandimmun^{\circledR}$; Sandoz, $Implanta^{\circledR}$; Hanmi). Sixteen healthy volunteers completed the study and each subjected single doses ($4{\tiems}100$ mg) of the test and the reference formulations in a two-way crossover design with a one-week drug-free interval between doses. Following each administration, whole blood concentrations of CsA were monitored over a period of 24 hour by both FPIA and HPLC methods. Blood concentrations nad pharmacokinetic parameters determined by either analytical method showed large intersubject variation, with the FPIA data showing relatively higher magnitude of intersubjecte variation than the HPLC data. The blood concentrations determined by FPIA were 1.1-1.3 times higher than those determined by HPLC. There were strong and significant correlations between the two methods (r>0.83 : p<0.0001). Intersubuject variation for the $AUC_{inf}{\;}and{\;}AUC_{24hr}$ of the test formulation was slightly reduced without statistical significance (paried -t test : p>0.05 $t_{max}$ was earlier nad $C_{max}$ was slightly lower for the test formulation, $AUC_{24h}, {\;}C_{max}, {\;}T_{max}$ and MRT determined separately from the data obtained by the two methods for the two formulations were examined by analyses of variance (ANOVA) for the bioequivalency evaluation. Results of ANOVA and confidence limits of terst/reference ratios of $AUC_{24th}$, $C_{max}$, $t_{max}$ and MRT, and statistical tests indicated the bioequivalence of the two formulations (i.e., test/reference ratio was within $100{\times}20%$) except for $C_{max}$ and $t_{max}$. The mean of tmax also showed 11.1% and 9.3% differences but the detection limit were 29.2% and 29.6% as determined by FPIA and HPLC resepctively. This experiments suggest that the data yielded for the two formulations demonstrated that they were bioequivalent.

  • PDF

Optimization of an Injection Molding Process for Polycarbonate Car Switch Buttons Using the Taguchi Method (실험계획법에 의한 폴리카보네이트 차량 스위치 버튼의 사출성형공정 최적화)

  • Kim, Cheol;Park, Jaewoo
    • Composites Research
    • /
    • v.29 no.1
    • /
    • pp.7-15
    • /
    • 2016
  • The quality of polymeric automotive parts depends highly on an injection molding process, which causes various defects, such as warpage, sink marks, weld lines, shrinkage, residual stress, etc. This study is to determine the optimum processing parameters, such as packing pressure, mold temperature, melting temperature, and packing time for the manufacture of polycarbonate buttons in cars on the basis of FEM, the Taguchi method, and analysis of variance (ANOVA). As a result, the optimum processing parameters of buttons made of polycarbonate material were obtained as follows: 140 MPa of packing pressure, $105^{\circ}C$ of mold temperature, $292.5^{\circ}C$ of melting temperature and 1 second of packing time. A gain of S/N (signal to noise) ratio, 10.2, was obtained with the optimum values. Moreover, the melting temperature was found to be the most significant factor followed by the mold temperature.

The Method of Results of Decision Reflections Between PI Project Valuation Groups Using AHP (AHP를 활용한 PI사업 평가그룹간 의사반영 방안)

  • Kim, Kwan-Joong;Jang, Myung-Soon
    • International Journal of Highway Engineering
    • /
    • v.8 no.4 s.30
    • /
    • pp.145-157
    • /
    • 2006
  • Generally, the method of the policy analysis has been used for making a policy decision of the development project of the road through the expert interview based on AHP. According to introducing PI, the study of the method of the integrating process for various opinion of the related groups is required. On this study I evaluate what is a difference between the results of integrated process and the AHP analysis on what is major considering factor in decision-making process. From the analysis, each evaluate factor is in level of significance by ANOVA. First, there is a significance level difference between Group A, C and Group B Second, there is also a significance level difference on the result of AHP analysis for each group in order to evaluate by integrated method. Finally, the method of AHP analysis which considers priority factor is expected as to be useful tool on decision-making of various group.

  • PDF

Statistical Tests for Time Course Microarray Experiments

  • Park, Tae-Seong;Lee, Seong-Gon;Choe, Ho-Sik;Lee, Seung-Yeon;Lee, Yong-Seong
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2002.05a
    • /
    • pp.85-90
    • /
    • 2002
  • Microarray technology allows the monitoring of expression levels for thousands of genes simultaneously. In time-course experiments in which gene expression is monitored over time we are interested in testing gene expression profiles for different experimental groups. We propose a statistical test based on the ANOVA model to identify genes that have different gene expression profiles among experimental groups in time-course experiments. Using this test, we can detect genes that have different gene expression profiles among experimental groups. The proposed model is illustrated using cDNA microarrays of 3,840 genes obtained in an experiment to search for changes in gene expression profiles during neuronal differentiation of cortical stem cells.

  • PDF

Analysis of Muscle Activities for Upper Extremity According to Satbar-Grip Patterns (샅바잡기 유형별 동작 시 상지근육의 근활동치 비교 분석)

  • Kim, Tae-Wan;Hwang, Kyu-Yeon;Kim, Jung-Suk
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.95-103
    • /
    • 2006
  • The purpose of this study was to analyze a change of maximal grip forces and EMG of agonists in upper extremity of 8 professional Ssirum players according to Satbar-grip patterns, to elucidate prime agonist muscles, contribution rate of each muscle, and a difference on EMG in upper extremity. one-way ANOVA(RM) performed for average and maximal values of each player after standardization and statistical significance was set as p<.05. The result includes the following: the highest grip force was A type with a statistic significance using one-way ANOVA and Duncan's comparison between A and C type. In summary the highest grip force was exerted on extension in the wrist than flexion in all grip types. Average and maximal values of biceps brachii and brachioradialis muscles were statistically significant and ones of flexor carpi ulnaris and extensor capi ulnaris were not.

An Experimental Study on Molding Factor for Spiral Type Micro Injection Product (스파이럴 형상 미세사출품의 성형 인자에 대한 실험적 연구)

  • Jung W. C.;Heo Y. M.;Shin K. H.;Yoon G. S.;Chang S. H.;Kim M. Y.
    • Transactions of Materials Processing
    • /
    • v.15 no.1 s.82
    • /
    • pp.65-70
    • /
    • 2006
  • In recent industry, with the miniaturization and high-precision of machine part, the development of mold manufacturing technology for mass production is accompanied by the development of new technology such as IT and BT In this study, the spiral type injection mold with a $200{\mu}m$ thickness is made to. investigating the influence of injection molding parameter and the flow length is measured through an experiment. Besides, Taguchi method is used in this experiment and the obtained data are analyzed using ANOVA method.

ANOVA for Water Repellent Finish data (발수가공 데이터의 분산분석)

  • Yun, Jung-Beom
    • Journal of Korean Society for Quality Management
    • /
    • v.16 no.1
    • /
    • pp.43-48
    • /
    • 1988
  • Most of silicone used for water repellent finish is MHP (methyl hydrodiene polysiloxane), which is formed by hydrolysis and condensation polymerization of MHD (methyl hydrodiene dichlorosilane: Me H Si $Cl_2$). The cross-linking theory explains the water repellent mechanism of MHP. The silicone finish on fiber could improve in handle, softness, abrasion resistance, soil repellency, tear strength and crease resistance, as well as water repellency. According to using method silicone-water repellent finishing agents, could be devided into air dry type and curing type. MHP is the typical curing type of water repellent finishing agent, and this type requires the curing temperature above $150^{\circ}C$ at least. High curing temperature is the very drawback of this curing type. For this reason, there has been global interest in the lowering of its temperature. The objective of this study is to investigate merits of alkali treatment for silicone finishing by ANOVA and LSD (least significant difference).

  • PDF

The Effect of Cutting Conditions on Surface Roughness in MQL Turning. (MQL 선삭가공시 가공조건의 표면거칠기 영향 분석)

  • 이춘만;황영국;정종윤
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.28-33
    • /
    • 2004
  • At present, industry and researchers are looking for ways to reduce the use of lubricants because of ecological and economical reasons. Therefore, metal cutting is to move toward dry cutting or semi-dry cutting. This paper presents an investigation into MQL(Minimum Quantity Lubrication) machining with the objective of deriving the optimum cutting conditions for the turning process of SM45C. To reach these goals several finish turning experiments were carried out, varying cutting speed, feed rate and oil quantity, with MQL. The surface roughness results of tests were measured and the effects of cutting conditions were analyzed by the method of Analysis of Variance(ANOVA). From the experimental results and ANOVA, it is found that a better surface roughness can be obtained by decreasing oil quantity and feed rate.

  • PDF