• 제목/요약/키워드: c/c composite

검색결과 3,896건 처리시간 0.161초

$Al_2O_3-SiC$ 복합재료의 상압소결시 치밀화에 미치는 SiC 원료분말의 크기영향 (Effect of SiC Particles Size on the Densification of $Al_2O_3-SiC$ Composite During Pressureless Sintering)

  • 채기웅
    • 한국세라믹학회지
    • /
    • 제36권11호
    • /
    • pp.1261-1265
    • /
    • 1999
  • Effect of SiC particle size of the densification of Al2O3-SiC composite during pressureless sintering was investigated. Two types of SiC powders having average particle size of 0.15${\mu}{\textrm}{m}$ and 3${\mu}{\textrm}{m}$ were used. Densification rate of the specimen containing 0.15${\mu}{\textrm}{m}$ SiC particles was slower than that of the specimen containg 3${\mu}{\textrm}{m}$ SiC particles. Although the relative density of the specimen containing 0.15${\mu}{\textrm}{m}$ SiC particles was below 90% of theoretical density after sintering at 155$0^{\circ}C$ the complete closure of open pores occurred. Therefore full densification could be obtained by subsequent HIP. On the other hand in the specimen containing 3${\mu}{\textrm}{m}$ SiC particles the complete closed pore was observed at 95% of theoretical density. Such a fast pore closure in the specimen containing 0.15${\mu}{\textrm}{m}$ SiC particles is likely to occur as a result of dense reaction layer formation on the specimen surface which is attributed to the high reactivity of small size particles with sintering atmosphere.

  • PDF

다공성 SiC-Si 복합체의 전기비저항에 미치는 Si 첨가량의 영향 (Effect of Si Addition on Resistivity of Porous SiC-Si Composite for Heating Element Application)

  • 전신희;이원주;공영민
    • 한국재료학회지
    • /
    • 제25권5호
    • /
    • pp.258-263
    • /
    • 2015
  • To fabricate porous SiC-Si composites for heating element applications, both SiC powders and Si powders were mixed and sintered together. The properties of the sintered SiC-Si body were investigated as a function of SiC particle size and/or Si particle contents from 10 wt% to 40 wt%, respectively. Porous SiC-Si composites were fabricated by Si bonded reaction at a sintering temperature of $1650^{\circ}C$ for 80 min. The microstructure and phase analysis of SiC-Si composites that depend on Si particle contents were characterized using scanning electron microscope and X-ray diffraction. The electrical resistivity of SiC-Si composites was also evaluated using a 4-point probe resistivity method. The electrical resistivity of the sintered SiC-Si body sharply decreased as the amount of Si addition increased. We found that the electrical resistivity of porous SiC-Si composites is closely related to the amount of Si added and at least 20 wt% Si are needed in order to apply the SiCSi composites to the heating element.

입자분산강화 알루미늄 복합재의 압출가공특성에 관한 연구 (A Study on Hot Extrusion Characteristics of Particulate Reinforced Aluminium Matrix Composite.)

  • 권혁천;윤의박
    • 한국재료학회지
    • /
    • 제5권8호
    • /
    • pp.953-959
    • /
    • 1995
  • 분말야금법으로 제조된 A6061기 입자분산강화 복합재의 열간압술가공에 있어서 압출특성에 미치는 강화입자의 종류, 빌렛특성 및 암술조건의 영향에 대하여 조사하였다. A6061기 복합재료의 열간 압술 전단 변형저항에 미치는 강화입자종류의 영향은 Si $C_{w}$ > A1$_2$ $O_{3f}$ > A1$_2$ $O_{3f}$ > Si $C_{p}$의 순으로 되었으며, 모든 강화입자에서 부피분율이 증가함에 따라서 Kw값도 증가하였다. 압출조건, 강화입자의 첨가량 및 첨가입자의 평균입도에 관계없이 A1$_2$ $O_{3p}$가 첨가된 복합재의 열간압출가공에 필요한 소요압력은 Si $C_{p}$의 경우보다 컸다. 압출압력은 압출 다이스 반각이 커질수록 감소하는 경향은 나타났다. 이것은 다이스 반각에 의해 생성되는 빌렛과의 접촉면적이 증가하여 전단마찰응력(m $k_3$)이 상승하기 때문이다. 압출시 압출온도 상승은 저온에서 ~$50^{\circ}C$ 정도 증가하였으며, 압출온도가 50$0^{\circ}C$ 이상이 되면 압출재 표면에 극심한 tearing이 발생하였다. 강화입자의 첨가량이 증가할수록 이 현상은 더 심하게 되었다.게 되었다.

  • PDF

Investigations of Temperature Effect on the Conduction Mechanism of Electrical Conductivity of Copolymer/Carbon Black Composite

  • El Hasnaoui, M.;Kreit, L.;Costa, L.C.;Achour, M.E.
    • Applied Microscopy
    • /
    • 제47권3호
    • /
    • pp.121-125
    • /
    • 2017
  • This study deals the prediction of temperature effect on low-frequency dispersion of alternating current (AC) conductivity spectra of composite materials based on copolymer reinforced with carbon black (CB) particles. A sample of ethylene butylacrylate loaded with 13% of CB particles were prepared and investigated using the impedance spectroscopy representation in the frequency range from 40 Hz to 0.1 MHz and temperature range from $20^{\circ}C$ to $125^{\circ}C$. The dielectric constant, ${\varepsilon}^{\prime}$, and dielectric losses, ${\varepsilon}^{{\prime}{\prime}}$, were found to decrease with increasing frequency. The frequency dependence of the AC conductivity follows the universal power law with a large deviation in the high frequency region, the positive temperature coefficient in resistivity effect has been observed below the melting temperature which makes this composite potentially remarkable for industrial applications.

난연성 복합적층재의 저속충격특성 (Low velocity Impact Characteristics of Non-flamable Composite Laminates)

  • 김재훈;김후식;조정미;박병준
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 추계학술발표대회 논문집
    • /
    • pp.179-182
    • /
    • 2001
  • Impacter tester was build of to evaluate the characterization of non-flamable Glass/phenol laminate plates under the low velocity impact. The damage of composite laminates are matrix cracking, delamination, and fiber breakage for impact energy. In this study, this is to find impact properties of Glass/phenol in used in a forehead part of lighting subway. To determine impact damage characteristics which is made in a laminate, use the UT C-scan after- macrography. And then evaluated the reduction of strength in a rate of impact energy with CAI(Compression After Impact) test

  • PDF

Glass/phenol 복합적층판의 저속충격 특성 (Low Velocity Impact Characteristics of Glass/phenol Composite Laminates)

  • 김재훈;김후식;박병준;안병욱
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.228-233
    • /
    • 2001
  • It is well known that composite laminates are easily damaged by low velocity impact. The damage of composite laminates subjected to impact loading are occurred matrix cracking, delamination, and fiber breakage. The damage of matrix cracking and delamination are reduced suddenly the compressive strength after impact. This study is to evaluate impact characteristics and the relationship between impact force and inside damage of composite laminates by low velocity impact loading. UT C-scan is used to determine impact damage areas by impact loading.

  • PDF

폴리에틸렌기지 복합재료의 동적탄성계수에 대한 강화재의 효과 (Effect of Reinforcements on Dynamic Elastic Modulus of Polyethylene Matrix Composite Materials)

  • 김경섭;정현규;홍순형
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 1999년도 추계학술발표대회 논문집
    • /
    • pp.1-4
    • /
    • 1999
  • The attenuation coefficients of SiC particle reinforced low-density polyethylene (LDPE) matrix composites were measured by pulse echo method and dynamic elastic measure method with varying the volume fraction of SiC particle ranged from 0% to 40% and the size of SiC particles ranged from 0.8$\mu$m to 48$\mu$m. The SiCp/LDPE composites were fabricated with the melt injection process and the fabricated composites showed almost full density above 99% up to 40vo1% SiCp reinforcements. The attenuation constant of LDPE measured by dynamic elastic constant had same result with that measured by pulse echo method, but the attenuation constant of SiCp/LDPE measured by dynamic elastic constant did not have same result with that measured by pulse echo method.

  • PDF

Development of sulfonated polysulfone composite membranes for ammonium rejection

  • Bastos, Edna T.R.;Barbosa, Celina C.R.;Silva, Jaciara C.;Queiroz, Vanessa B.C.;Vaitsman, Delmo S.
    • Membrane and Water Treatment
    • /
    • 제4권2호
    • /
    • pp.83-93
    • /
    • 2013
  • In the present investigation, were synthesized composite membranes prepared by simultaneous casting of two polymer solutions using the technique of phase inversion by immersion / precipitation. The support layer was prepared using polyethersulfone and polysulfone as base polymer and for the top layer was used sulfonated polysulfone (SPSU) with 50% sulfonation degree. The morphology of the resulting membranes were characterized by scanning electron microscopy (SEM). The final results showed that it is possible to prepare composite membranes by simultaneous casting of two polymer solutions with adherence between the two layers. Regarding the permeation tests, the developed membranes presented values of hydraulic permeability within the range of commercial nanofiltration (NF) membranes. Values rejection of 80% ammonium ions can be increased by using a SPSU with a greater degree of sulfonation.